• Title/Summary/Keyword: Ambient ionization

Search Result 24, Processing Time 0.026 seconds

Optical Long-slit Spectroscopy of Parsec-scale Jets

  • Oh, Heeyoung;Pyo, Tae-Soo;Yuk, In-Soo;Kim, Kang-Min;Lee, Sungho;Park, Byeong-Gon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.55.2-55.2
    • /
    • 2013
  • We present the observational study of parsec-scale jets from YSOs reaching lengths of several arc-minutes. The medium-resolution spectroscopic data were obtained between 6000 - $7000{\AA}$ with BOAO long-slit spectrograph. By performing multi-position observation, we investigated the physical variation of the jets and the ambient gas along the whole path of the jets. The flux, electron density, ionization fraction, and electron temperature are discussed with the estimated line ratios between from [OI], [NII], $H{\alpha}$ and [SII] emission lines. This study carried out with more than 8 jets of YSOs including low- to intermediate-mass stars. We also briefly discuss the kinematics of the outflows using spatial and spectroscopic data.

  • PDF

Assessment of correlation between markers of ambient monitoring and biological monitoring of dimethylformamide for workers in synthetic leather manufacturing factories in Korea (국내 합성피혁제조업 근로자에 대한 디메틸포름아미드의 공기중 농도와 생물학적 노출지표간의 상관성 평가)

  • Hwang, Yang In;Lee, Mi-Young;Chung, Yun Kyung;Kim, Eun A
    • Analytical Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.315-325
    • /
    • 2013
  • The possibility of acute hepatotoxicity caused by dimethylformamide (DMF) requires regular monitoring of the workers who are using DMF to prevent the occupational disease. The authors performed ambient and biological monitoring of workers involved in synthetic leather manufacturing processes using DMF to assess the correlation between the markers of ambient and biological monitoring of DMF. The authors monitored 142 workers occupationally exposed to DMF from 19 workshops in the synthetic leather and ink manufacturing industries located in northern region of Gyeonggi-do. The subjects answered questionnaire on work procedure and use of personal protective equipment to be classified by exposure type. DMF in air samples collected using personal air samplers, diffusive and active sampler, was analysed using gas chromatograph-flame ionization detector (GC-FID) with DB-FFAP column (length 30 m, i.d. 0.25 mm, film thickness 0.25 ${\mu}m$). Urinary N-methylformamide (NMF) was analysed using gas chromatograph-mass selective detector (GC-MSD) at selected ion monitoring (SIM) mode with DB-624 column (length 60 m, i.d. 0.25 mm, film thickness 1.40 ${\mu}m$). Geometric mean (GM) and geometric standard deviation (GSD) of the ambient DMF was $6.85{\pm}3.43$ ppm, and GM and GSD of urinary NMF was $42.3{\pm}2.7$ mg/L. The ratio of subjects with DMF level over 10 ppm was 44%, and those with urinary NMF over 15 mg/L was 87%. NMF in urine adjusted by DMF in air was $4.61{\pm}2.57$ mg/L/ppm and $9.50{\pm}2.41$ mg/L/ppm, respectively, with or without respirator. There was seasonal differences of NMF in urine adjusted by DMF in air, $7.63{\pm}2.74$ mg/L/ppm in summer and $4.53{\pm}2.29$ mg/L/ppm in winter. The urinary NMF concentration which corresponds to 10 ppm of ambient DMF was 52.7 mg/L (r=0.650, n=128). Considering the difference of the route of exposure which resulted from the compliance of wearing personal protective equipment, the estimated contribution of respiratory and dermal exposure route for DMF was 48.5% vs. 51.5%.

Direct Analysis in Real Time Mass Spectrometry: a Powerful Tool for Fast Analysis

  • Li, Xianjiang;Wang, Xin;Li, Linnan;Bai, Yu;Liu, Huwei
    • Mass Spectrometry Letters
    • /
    • v.6 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Direct analysis in real time mass spectrometry (DART-MS) is one of the variants of ambient mass spectrometry. The ionization process of DART-MS is in open environment and only takes few seconds, so it is suitable for fast analysis. Actually, since its introduction in 2005, more and more attentions have been drawn to its various applications due to its excellent properties, e.g., fast analysis, and no or less sample preparation, high salt tolerance and so on. This review summarized the promising features of DART-MS, including its ionization mechanism, equipment modification, wide applications, coupling techniques and extraction strategies before analysis.

Development of Real-time and Simultaneous Quantification of Volatile Organic Compounds in Ambient with SIFT-MS (Selected Ion Flow Tube-Mass Spectrometry) (선택적다중이온질량분석기를 이용한 대기 중 휘발성유기화합물 실시간 동시분석법 개발 및 적용)

  • Son, Hyun Dong;An, Joon Geon;Ha, Sung Yong;Kim, Gi Beum;Yim, Un Hyuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.3
    • /
    • pp.393-405
    • /
    • 2018
  • Volatile organic compounds (VOCs) are representative air pollutants due to their detrimental effects on human health and their role in formation of secondary organic aerosols. Assessments and monitoring programs of VOCs using periodic grab sampling like Tedlar bags, canisters, and sorbent traps provide limited information, often with delay times of days or weeks. Selected ion flow tube mass spectrometry (SIFT-MS) is an emerging analytical technique for the real-time quantification of VOCs in air. It relies on chemical ionization of the VOCs molecules in air introduced into helium carrier gas using $H_3O^+$, $NO^+$, and $O_2{^+}$ precursor ions. Real-time monitoring method of 60 VOCs in the ambient air was developed using TO-15 standard gas mixture. Calibration curves, method detection limit, and quantitation reproducibility of the target compounds were tested. Dynamic dilution system was used to dilute standard gas from 0.174 ppbv to 100 ppbv, where calibration curves showed good linearity with $r^2$> 0.95 in all target analytes. Limit of detection (LOD) all compounds were sub ppbv, and some halogenated compounds showed pptv levels. Seven consecutive analyses of target compounds showed good repeatability with relative standard deviation of less than 10%. One day monitoring of VOCs in ambient air was conducted in Geoje. Average concentration of target VOCs in Geoje were relatively lower than other regions, among which formaldehyde showed the highest concentration ($15.4{\pm}5.78ppbv$). SIFT-MS provided good temporal resolution data (1 data per 3.2 minute), which can be used for identifying ephemeral short-term event. It is expected that SIFT-MS will be a versatile monitoring platform for VOCs in ambient air.

Analysis of a.c. Characteristics in $ZnO-Bi_2O_3-Cr_2O_3$ Varistor Using Dielectric Functions (유전함수를 이용한 $ZnO-Bi_2O_3-Cr_2O_3$ 바리스터의 a.c. 특성 분석)

  • Hong, Youn-Woo;Shin, Hyo-Soon;Yeo, Dong-Hun;Kim, Jong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.14-14
    • /
    • 2009
  • In this study, we investigated the effects of Cr dopant on the bulk trap level and grain boundary characteristics of $Bi_2O_3$-based ZnO (ZB) using dielectric functions such as $Z^*$, $Y^*$, $M^*$, ${\varepsilon}^*$, and $tan{\delta}$. More than two bulk traps of $Zn_i$ and $V_o$ probably in different ionization states could be identified in ZBCr($ZnO-Bi_2O_3-Cr_2O_3$). The grain boundaries of ZBCr could be electrochemically divided into two types: sensitive to ambient oxygen and thus electrically active one and oxygen-insensitive and thus electrically inactive one.

  • PDF

Environment Effects on the Stability of the CQUEAN CCD

  • Choi, Nahyun;Pak, Soojong;Choi, Changsu;Park, Won-Kee;Im, Myungshin;Jeon, Yiseul;Baek, Giseon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.222.2-222.2
    • /
    • 2012
  • Camera for QUasars in EArly uNiverse (CQUEAN) is an optical CCD camera attached to the 2.1m Otto Struve telescope at the McDonald Observatory, USA. CCD output signal contains the electrons generated by photoionization of incident light and thermal ionization. Therefore reliable photometric result can be obtained only under the stable condition of CCD thermal properties. We investigated the temperature dependency of the various characteristics of CQUEAN CCD chip, including bias level, dark level, gain, and quantum efficiency (QE), with the CQUEAN observation and calibration data obtained during 2012 May run. We discuss the environmental effects, i.e., ambient temperature, as well as CCD temperature on the stability of its characteristics.

  • PDF

Development of Ambient Ionization Mass Spectrometry Imaging for Live Cells and Tissues

  • Kim, Jae-Yeong;Seo, Eun-Seok;Lee, Seon-Yeong;Jeong, Gang-Won;Mun, Dae-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.229.1-229.1
    • /
    • 2015
  • 생체 시료인 세포나 조직을 분석을 위해 임의로 파괴하거나 훼손하지 않은 본래의 상태에서 세포에 존재하는 다양한 생체분자 물질의 질량과 조성을 분석하고 영상화할 수 있는 대기압 표면 질량분석 이미징 기술을 개발했다. 생체 시료의 표면을 질량 분석을 하기 위해서는 대기압 분위기에서 시료에 열적 손상이 없는 조건으로 시편의 이온화 및 탈착 과정이 이루어지게 하기 위해 저온 대기압 탈착/이온화원으로 저온대기압 플라즈마 젯과 펨토초 적외선 레이저를 결합하여 대기압 이온화원을 제작하였다. 기존에 잘 알려진 저온 대기압 플라즈마 젯 소자는 유리관에 방전기체를 흘려주고 전극에 고전압을 인가하는 방식으로 제작했으며, 또 다른 대기압 이온화원으로서 근적외선 대역의 고출력 펨토초 레이저 빔을 현미경용 대물렌즈로 집속하여 생체시료에 조사시켰다. 수백 나노미터에서 수 마이크로미터 수준으로 빔을 집속할 수 있는 펨토초 레이저는 금나노로드의 도움으로 생체 시료를 매우 작은 수준으로 탈착하는 데 주로 사용하며, 수십 마이크로미터에서 수 밀리미터 정도의 크기를 가지는 저온 대기압 플라즈마 젯은 탈착된 물질을 이온화시키는데 사용하여, 이 두 가지 이온화원을 결합하여 이온화원으로 사용한다. 시료에서 발생한 이온을 질량분석기 입구까지 잘 끌고 갈 수 있도록 이온 전달관을 설계하고 보조펌프를 장착 사용한다. 이렇게 자체 개발한 대기압 이온화원을 상용 질량분석기기와 결합하여 대기압 분위기에서 시료의 표면을 질량분석할 수 있는 시스템과 측정 기술을 개발했다. 현미경 스테이지에 정밀 2-D 자동 스캐닝 스테이지를 장착하여 질량분석 정보에 공간 정보를 더할 수 있는 질량분석 이미징 기술 방법을 개발하여 생체 시편의 질량분석 이미징을 얻었다. 수분을 포함하는 생채시료로부터 단백질, 지질, 대사물질을 직접 분리하여 분석하는 이 새로운 질량분석법은 기존의 분석법에 비해 훨씬 더 많은 생체분자 정보를 얻을 수 있으며 공간정보를 더해 영상화할 수 있는 큰 장점이 있다. 대기압 표면 질량분석 기술은 생체시료를 파괴해서 용액화할 필요도 없으며, 진공 챔버에 넣기 위해 필요한 복잡한 전처리 과정 단계를 간략화 할 수 있으며 최종적으로는 살아있는 세포나 생체 조직도 정량 분석이 가능하여 생명과학 및 의료진단 분야에서 응용할 수 있는 분야는 무궁무진할 것이다.

  • PDF

Estimation of Quantitative Source Contribution of VOCs in Seoul Area (서울지역에서의 VOCs 오염원 기여도 추정에 관한 연구)

  • 봉춘근;윤중섭;황인조;김창녕;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.4
    • /
    • pp.387-396
    • /
    • 2003
  • A field study was conducted during the summer time of 2002 to determine compositions of volatile organic compounds (VOCs) emitted from vehicles and to develop source emission profiles that is applied to CMB model to estimate the source contribution of certain area. Source emission profile is widely used for the estimation of source contribution by the chemical mass balance model and have to be developed applicable for the target area of estimation. This study was aimed to develop source emission profile and estimation of source contribution of VOCs after application of the chemical mass balance (CMB) receptor model. After considering the emission inventory and other research results for the VOCs in Seoul, Korea, the sources like vehicle emission (tunnel), gas station (gasoline, diesel), solvent usage (painting operation, dry cleaning, graphic art), and gas fuels were selected for the major VOCs sources. Furthermore, ambient air samples were simultaneously collected from 09:00 to 11:00 for four days at eight different official air quality monitoring sites as receptors in Seoul during summer of 2001. Source samples were collected by canisters, and then about seventy volatile organic compounds were analyzed by gas chromatography with flame ionization detector (GC/FID). Based on both the developed source profiles and the database of the receptors, CMB model was intensively applied to estimate mass contribution of VOCs sources. Examining the source profile from the vehicle, the portion of alkanes of VOCs was highest, and then the portion of aromatics such toluene, m/p-xylene were followed. In case of gas fuel. they have their own components; the content of butane, propane, ethane was higher than any other component according to the fuel usage. The average of the source apportionment on VOCs for 8 sites showed that the major sources were vehicle emission and gas fuels. The vehicle emission source was revealed as having the highest contribution with an average of 49.6%, and followed by solvent with 21.3%, gas fuel with 16.1%, gasoline with 13.1%.

Measurements of Indoor and Outdoor Volatile Organic Compounds(VOCs) Concentrations in Ambient Air (실내외 공기중 휘발성 유기화학물질(VOCs)의 농도조사에 관한 연구)

  • 신혜수;김윤신;허귀석
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.4
    • /
    • pp.310-319
    • /
    • 1993
  • A pilot study was conducted in order to investigate the concentrations of indoor and outdoor VOCs (Volatile Organic Compounds) at ten homes and four building offices in Seoul during March-April, 1993. The five components of VOCs(Benzene, Toluene, Ethylbenzene, o-Xylene, m/p-Xylene) were collected using charcoal tube and were analysed using Gas Chromatography(GC) with a Flame Ionization Detector(FID). The mean concentations of indoor VOCs were shown as Benzene of 38.9 .mu.g/m$^{3}$. Toluene of 165.0 .mu.g/m$^{3}$, Ethylbenzene of 21.7 .mu.g/m$^{3}$, o-Xylene of 11.6 .mu.g/m$^{3}$ and m/p-Xylene of 29.3 .mu.g/m$^{3}$, but those corresponding that indoor levels of VOCs were higher than corresponding outdoor levels. The ratio of indoor and outdoor VOCs were higher than corresponding outdoor levels. The ratio of indoor and outdoor VOCs concentrations was 0.99 for Benzene, 1.23 for Toluene, 5.86 for Ethylbenzene, 5.23 for o-Xylene, 2.41 for m/p-Xylene in homes, while 2.02 for Benzene, 1.15 for Toulene, 0.96 for Ethylbenzene, 1.41 for o-Xylene, 1.38 for m/p-Xylene in offices, respectively. The mean concentrations of VOCs in homes were higher than those levels in offices, while the mean concentration of VOCs during active hour of occupants in a day were higher 1-3 times than the levels during non-active hour. Comparing VOCs levels by building's age, the mean concentrations of Benzene, o-Xylene and m/p-Xylene were higher in new building than old building, but the mean concentrations of Toluene and Etylbenzene in new building were lower than old building. The mean concentrations in all components of VOCs in smoking area were higher than non-smoking area. These results suggested that the VOC levels were affected by various indoor characteristics and behavioral activity of occupants.

  • PDF

Analysis of a.c. Characteristics in ZnO-Bi2O3Cr2O3 Varistor using Dielectric Functions (유전함수를 이용한 ZnO-Bi2O3Cr2O3 바리스터의 a.c. 특성 분석)

  • Hong, Youn-Woo;Shin, Hyo-Soon;Yeo, Dong-Hun;Kim, Jin-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.5
    • /
    • pp.368-373
    • /
    • 2010
  • In this study, we have investigated the effects of Cr dopant on the bulk trap levels and grain boundary characteristics of $Bi_2O_3$-based ZnO (ZB) varistor using admittance spectroscopy and dielectric functions (such as $Z^*,\;Y^*,\;M^*,\;{\varepsilon}^*$, and $tan{\delta}$). Admittance spectra show more than two bulk traps of $Zn_i$ and $V_o$ probably in different ionization states in ZnO-$Bi_2O_3-Cr_2O_3$ (ZBCr) system. Three kinds of temperature-dependant activation energies ($E_{bt}'s$) were calculated as 0.11~0.14 eV of attractive coulombic center, 0.16~0.17 eV of $Zn_{\ddot{i}}$, and 0.33 eV of $V_o^{\cdot}$ as dominant bulk defects. The grain boundaries of ZBCr could be electrochemically divided into two types as a sensitive to ambient oxygen i.e. electrically active one and an oxygen-insensitive i.e. electrically inactive one. The grain boundaries were electrically single type under 460 K (equivalent circuit as parallel $R_{gb1}C_{gb1}$) but separated as double one ($R_{gb1}C_{gb1}-R_{gb2}C_{gb2}$) over 480 K. It is revealed that the dielectric functions are very useful tool to separate the overlapped bulk defect levels and to characterize the electrical properties of grain boundaries.