• Title/Summary/Keyword: Ambient Control

Search Result 611, Processing Time 0.025 seconds

Recognition of Material Temperature Response Using Curve Fitting and Fuzzy Neural Network

  • Ryoo, Young-Jae;Kim, Seong-Hwan;Chang, Young-Hak;Lim, Yong-Cheol;Kim, Eui-Sun;Park, Jin-Kyn
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.3 no.2
    • /
    • pp.133-138
    • /
    • 2001
  • This paper describes a system that can used to recognize an unknown material regardless of the change of ambient tem-perature using temperature response curve fitting and fuzzy neural network(FNN). There are some problems to realize the recogni-tion system using temperature response. It requires too many memories to store the vast temperature response data and it has to be filtered to remove noise which occurs in experiment. And the temperature response is influenced by the change of ambient tempera-ture. So, this paper proposes a practical method using curve fitting the remove above problems of memories and nose. And FNN is propose to overcome the problem caused by the change of ambient temperature. Using the FNN which is learned by temperature responses on fixed ambient temperature and known thermal conductivity, the thermal conductivity of the material can be inferred on various ambient temperature. So the material can be recognized by the thermal conductivity.

  • PDF

Changes in Hematological Responses and Antioxidative Enzyme Activities of Japanese Eel Anguilla japonica Exposed to Elevated Ambient Nitrite (아질산에 노출된 뱀장어(Anguilla japonica)의 혈액학적 반응과 항산화효소의 활성 변화)

  • Jo, Su-Hyun;Kim, Heung-Yun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.47 no.6
    • /
    • pp.860-868
    • /
    • 2014
  • The study was performed to investigate changes in hematological responses and antioxidative enzyme activities (superoxide dismutase, SOD; catalase, CAT) of Japanese eel Anguilla japonica following exposure to 0 (control), 2.33, 4.60, 6,64 and 8.78 mM nitrite-N in fresh water for 48 h. Hematological parameters such as plasma nitrite, electrolytes, cortisol, glucose, glutamate oxaloacetate transaminase (GOT), glutamate pyruvate transaminase (GPT), hemoglobin (Hb), methemoglobin (metHb) and NADH-methemoglobin reductase (NMR) were measured. Plasma nitrite, cortisol, metHb and NMR increased directly with increasing ambient nitrite concentration, while Hb content showed a progressive decline. Levels of plasma potassium, GOT and GPT of the eel exposed to 6.64 mM ambient nitrite were significantly higher than the control fish. The activity of SOD and CAT in plasma, gill and liver of the eel following exposure to nitrite were augmented by increasing ambient nitrite. Levels of plasma nitrite, metHb, NMR, cortisol, glucose and antioxidative enzyme activities of the eel exposed to 2.33 mM ambient nitrite were significantly higher than the control fish. This study suggested that the eel acutely exposed to elevated ambient nitrite causes nitrite-induced stress responses, changes in antioxidative enzyme activities and hematological parameters.

Efficient Method of fixing the Setting(4M standardization) in Melting furnace Operation (용해로 운전에서 Setting고정(4M 표준화)의 효율적 방안)

  • Jang, Do-Soo;Lee, Sae-Jae;Suh, Jung-Yul;Kim, I-Nam;Chung, Chong-Won;Cho, Jin-Hyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.30 no.1
    • /
    • pp.96-104
    • /
    • 2007
  • Glass melting process is influenced by both control and observation factors, where control factors include quantity and mixing ratio of raw material, the amount of fuel and air in-take. Further observation factors include temperature and pressure at each step of process inside glass melting furnace. Ambient Control is an effective means to eliminate complications from excessive variation among raw materials, or external disturbance from wide fluctuation of environment around equipments. Ambient Control uses both control and observation factors mentioned above. This study suggests an effective Proactive Control System that can enable genuine 4M standardization in glass melting furnace by applying Ambient Control.

Drop Size Measurement using Image Processing Method under High Ambient Pressure Condition (고압환경에서 이미지 프로세싱 기법을 이용한 액적크기 측정)

  • Lim Byoungjik;Khil Taeock;Jung Kihoon;Yoon Youngbin
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.111-114
    • /
    • 2003
  • Drop size is one of the most important parameters which are control the performance of the engine using liquid fuel/oxidizer and drop formation is mainly controlled by aerodynamic force caused by ambient gas. Because of this, empirical data and correlation acquired under standard ambient condition are not valid. So experiments under high ambient pressure condition to measure the drop size using image processing method And find the empirical correlation between SMD and chamber pressure(density), injection velocity.

  • PDF

Physiological Responses and Fruit Quality Changes of 'Fuji' Apple under the High Night Temperature (야간 고온에 의한 사과 후지 품종의 생리반응 및 과실품질 변화)

  • Ryu, Suhyun;Kwon, YongHee;Do, Kyeong Ran;Han, Jeom Hwa;Han, Hyun Hee;Lee, Han Chan
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.264-270
    • /
    • 2015
  • Tropical night phenomenon has been increasing due to global warming recently, it is expected that fruit quality of apples will decrease due to elevated night temperature condition. In the present study, fruit quality at maturity, periodic anthocyanin biosynthetic gene expression and sugar contents in leaves and fruit flesh were investigated to establish the physiological responses of 'Fuji' apples under high night temperature. The night temperature were treated with such as ambient (control), ambient $-4^{\circ}C$, and ambient $+4^{\circ}C$. After the treatment, high night temperature didn't affect fruit diameter, weight, and soluble sugar contents. Coloration of ambient $+4^{\circ}C$ was poor than that of control, however there was no significant difference between these genes expression of control and that of ambient $+4^{\circ}C$ treatment in the late coloration season. Increase of sorbitol and glucose contents at ambient $+4^{\circ}C$ in leaves were smaller than those at control, and then sorbitol and sucrose contents in fruit flesh at ambient $+4^{\circ}C$ were smaller than those at control. The cross section of leaves showed that there were no differences with the structure of parenchyma and epidermis tissues between the treatments, but starch granules in the palisade parenchyma cells decreased in high night temperature treatments. Consequently, high night temperature didn't affect the fruit quality, but changed sugar contents in leaves and fruit flesh, and suppressed coloration regardless of anthocyanin biosynthetic gene expression.

Effects of L-arginine on Endothelium Derived Factors and Cyclic Nucleotides in Broilers under Low Ambient Temperature

  • Han, Bo;Yoon, Soonseek;Han, Hongryul;Wang, Xiaolong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.11
    • /
    • pp.1570-1574
    • /
    • 2004
  • A flock of AA breed chickens were reared in peterstme brood-vait chamber and were provided with high energy pelleted feed. At 14 d of age, a total of 350 birds were randomly divided into 3 groups as follows: 100 birds were exposed to normal ambient temperature of 20$^{\circ}C$ for control group; 150 birds were exposed to lower ambient temperature of 11$^{\circ}C$ to induce ascites (treatment I); and another group of 100 birds were exposed to lower ambient temperature of 11$^{\circ}C$ and fed diet containing 1% L-arginine for ascitic prophylactic treatment (treatment II). Samples were collected from blood and abdominal fluid of chicken at 3, 4, 5, 6 and 7 wk of age subsequently, to analysis the contents of plasma endothelin (ET-1), angiotensin II (Ang II), cyclic adenosine monophosphate (cAMP), cyclic guanosine monophosphate (cGMP). The results indicated that the contents of cAMP, cGMP, and Ang II in reatment I and ascitic broilers were higher than the corresponding control group (p<0.01, p<0.05), ET-1 of preascitic broilers were control group (p<0.05), while there was an insignificant difference with later ascitic broilers. The contents of cAMP and cGMP in treatment II were higher than the treatment I and control groups (p<0.01, p<0.05), whereas, the contents of Ang II were gradually decreased compared to the control group (p<0.05), the contents of ET-1 were insignificantly different. On further analysis, the increased plasma Ang II at low ambient temperature condition in broilers made endothelium cell secretion of increased ET-1, cAMP, cGMP and decreased NO. Therefore, low temperature accelerated ascites syndrome in broilers. Supplemently L-arginine can decrease ET-1, and increase cAMP and cGMP. It is concluded that cAMP mediated in broilers pulmonary hypertension syndrome.

Ambient Vibration Tests for Enhanced Bridges Integrity Assessment (교량건전성 평가의 개선을 위한 상시진동시험)

  • Yi, Jin-Hak;Lee, Jong-Jae;Lee, Chang-Geun;Lee, Won-Tae;Yun, Chung-Bang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.611-614
    • /
    • 2004
  • In this study, ambient vibration tests are carried out to replace the current bridge integrity assessment using controlled vehicle test, which requires the traffic control and may induce public complains. Ambient vibration tests and output-only modal identification can be very effective approach to evaluate the bridge integrity because the ambient vibration tests can be performed very easily without trafnc control. The bridges in test road of Jungbu Inland Highway were tested and the results are discussed here.

  • PDF

Effect of Ambient Conditions on the Soot Generation of Decane Fuel Droplet (분위기 조건이 Decane 액적의 Soot 생성에 미치는 영향)

  • Lim, Young Chan;Suh, Hyun Kyu
    • Journal of ILASS-Korea
    • /
    • v.19 no.4
    • /
    • pp.211-215
    • /
    • 2014
  • The main purpose of this study is to provide basic information of droplet soot generation of decane fuel. To achieve this, this paper presents the experimental results on the decane droplet combustion conducted under various ambient pressure($P_{amb}$), and oxygen concentration($O_2$) conditions. At the same time, the experimental study was conducted in terms of soot volume fraction($f_v$) and its maximum value. Also, visualization of single fuel droplet was conducted by high resolution CCD camera and ambient pressure($P_{amb}$) and oxygen concentration($O_2$) was changed by control system. It was revealed that higher ambient pressure($P_{amb}$), and oxygen concentration($O_2$) enhanced the soot generation and improved the maximum soot volume fraction( $f_v$).

A Development of COS Holder to Reduce an Impact Ambient Noise (충격성 소음 감소용 COS 홀더 개발)

  • Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1062-1068
    • /
    • 2007
  • We are using COS to block the excess current and to protect the transformer. But the fuse of COS is melt due to the overload resulting from the excess current flows and it destroys an air severing relations to clear as strong arc happens. Such phenomenon induces an impact ambient noise and it gives the circumstance area resident or pedestrian the fear. Thus, it is necessary that we urgently need to control the ambient noise from the actual circumstances. In this study, we investigate the characteristic of an impact ambient noise associate with the melting state of the COS fuse and suggest the method to reduce the noise.

  • PDF

The Characteristic Study of Capacity Control of an Industrial Cooler Using an Invertor Compressor with Varing the Ambient Temperatures (인버터 압축기를 채용한 산업용 수냉각기의 외기온도 변화에 따른 용량제어 특성)

  • Baek, Seung-Moon;Moon, Choon-Geun;Kim, Eun-Pil;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.238-243
    • /
    • 2011
  • The ambient temperature of the experimental conditions changes by varying the speed of the compressor and the electronic expansion valve opening. The effects of changing valve opening to the entire system has been investigated. The results show that the ambient temperatures of $35^{\circ}C$ and $30^{\circ}C$ controlled at 30Hz must be avoided. The capacity control range of the control compressor with changing speed is about 43~100% at $35^{\circ}C$, 43~100% at $25^{\circ}C$ and 48~100% at $10^{\circ}C$, respectively. The results show the capacity control range decreases with decreasing ambient temperature.