• 제목/요약/키워드: Ambient Air

검색결과 1,456건 처리시간 0.027초

김해시 공업지역의 대기 중 Methylethylketone 측정과 활성산소종 생성에 관한 연구 (Detection of Methylethylketone in the Ambient Air of Industrial Area in Gimhae City and Its Effect on the Generation of Reactive Oxygen Species)

  • 박흥재;정성욱;김종명;안원근
    • 한국환경과학회지
    • /
    • 제16권8호
    • /
    • pp.995-999
    • /
    • 2007
  • This study assessed the characteristics of emission and cell toxicology of Methylethylketone(MEK) in ambient air of industrial area. MEK is produced by the oxidation of sec-butyl alcohol and used as the solvent for making ink, printing, coating of film, bonding material and drug extraction. The MEK concentrations in the ambient-air of industrial area in Gimhae City was detected in the range of $25.4{\sim}1,580{\mu}g/m^3$ with an average $297.4{\mu}g/m^3$. The concentration of MEK showed a descending tendency from April to August followed by its increased tendency since then. The effects of MEK on the human lung cancer A549 cells was examined by the generation of Reactive Oxygen Species(ROS) and cytotoxicity. The range of MEK concentration detected in the area induced ROS generation affecting the oxidation state with a little effects on the viability of the cells.

온도보상을 고려한 열선형 공기유량 측정시스템에 관한 실험적 연구 (Experimental study on hot-wire type air flow rate measurement system considering ambient temperature compensations)

  • 이민형;유정열;김사랑;고상근;윤준원;김동성
    • 오토저널
    • /
    • 제13권4호
    • /
    • pp.62-75
    • /
    • 1991
  • The purpose of this study is to perform modelings and experiments to measure air flow rate using hot-wires and a CTA(Constant Temperature Anemometer). The flow rate can be obtained by measuring the heat loss of the hot-wire due to the variations of flow velocity when the hot-wire is maintained at uniform temperature. But the defect of this method is that the output signal changes not only by the flow rate but also by the ambient temperature. Thus, in the present study, a method which compensates the variations of the ambient temperature has been introduced to measure exact flow rate. To be more specific, the bridge circuit of the usual hot-wire anemometer system has been modified in such a way that a temperature resistance sensor and a variable resistance are placed in one of the legs to compensate the different temperature coefficients of both the hot-wire and the temperature compensating resistance for flow velocity or for flow mass up to the flow temperature of 50 .deg.C. Comparing the modeling and experimental results, it has been shown that the compensating point differs as the flow rate varies. Therefore, optimum compensation points are sought to construct the circuit. The present modeling and experimental results may be applied to the design of actual air flow meters for automobiles.

  • PDF

분위기 조건이 직접분사식 인젝터의 미립화에 미치는 영향 (Effects of Ambient Conditions on the Atomization of Direct Injection Injector)

  • 이중순
    • 한국분무공학회지
    • /
    • 제6권1호
    • /
    • pp.25-34
    • /
    • 2001
  • Several efforts to meet the exhaust gas regulation have been undertaken by many researchers in recent years. Main researches are on development of design techniques of intake port and combustion chamber, atomisation of fuel and precise control of air-fuel ratio, post-treatment of exhaust gas and so on. Engine technology is changed from PFI to GDI to correspond with exhaust gas regulation. GDI technique makes it possible to preserve lean air-fuel ratio and control accurate air-fuel ratio. Nevertheless, It is not cleared that information of spray characteristics and atomization process are very dependent on fluctuation of pressure and change of temperature in intake stroke. In this study, a constant volume combustion chamber is manufactured to investigate various fluctuations of in-cylinder pressure for injection duration. It is taken photographs of injection process of conventional GDI injector using PMAS. Then, it was verified experimently that ambient conditions as temperature and pressure of combustion chamber have effects on process of spray growth and atomization of fuel.

  • PDF

일본 요코하마 대기 중 PCBs의 가스-입자 분배 (Gas-Particle Partitioning of PCBs in Ambient Air, Yokohama Japan)

  • 김경수
    • 한국대기환경학회지
    • /
    • 제21권3호
    • /
    • pp.285-293
    • /
    • 2005
  • This study was aimed at estimation of gas-particle partitioning of polychlorinated biphenyls (PCBs) in ambient air. The samples were collected at urban site in Japan from March 2002 to January 2003. The concentration of total PCBs (from 4 CB to 10 CB) and TEQ (Toxic equivalent) ranged from 62 to $247\;pg/m^3$ and from 2 to $14\;fgTEQ/m^3 $, respectively. The average contribution $(\%)$ of gas phase to total PCBs concentration was above $80\%$, which suggests that in the atmosphere PCBs predominantly existed in the gas phase. The weak correlations between total PCBs concentration and temperature was found. However this result was due to a typhoon during summer and raining during sampling period. The gas-particle partition coefficient (Kp) was obtained as a function of temperature. The partition ratio of gaseous and particulate phase PCBs can be estimated for an arbitrary temperature. The plot of gas/particle partition coefficient (log Kp) vs. sub-cooled liquid vapor pressure $(log\;P_L)$ had reasonable correlations for individual samples but the slope varied among the samples (coefficients of determination for log Kp versus log $P_L$ plot were> 0.76 $(p<0.0001)$, except for 3 samples). As a result, the variations in the slope among the sampling period may be due to change of temperature, raining during sampling period and wind in this study.

도시 생활폐기물 매립지에서 발생되는 악취물질의 조성에 대한 연구 (The Composition of Odor Compounds Emitted from Municipal Solid Waste Landfill)

  • 손윤석;김조천;김기형;임보아;박강남;이우근
    • 한국대기환경학회지
    • /
    • 제23권6호
    • /
    • pp.666-674
    • /
    • 2007
  • In this study, sampling and analysis was carried out for 13 compounds, in order to investigate the odorous compound emissions from landfill stacks and surrounding ambient air. These results revealed that concentration of hydrogen sulfide was $0.13{\sim}0.66\;ppb$ in the ambient air. Also, concentrations of hydrogen sulfide ($151{\sim}358\;ppm$) were the highest value in odorous sulfur compounds from landfill stacks. In case of VOC, toluene was obtained the highest out of volatile organic compounds. It was found that the concentrations of hydrogen sulfide near the landfill was higher than that inside city such as Seoul although it was located in a rural area. The result was due to the effect of hydrogen sulfide emitted from landfill stacks.

대형 용해로의 외부 환경변수를 통제하기 위한 주변 환경관리의 활용 (Using Ambient Control to Prevent External Disturbances in Large-scale Furnace)

  • 조진형;장성호;이세재;장도수;서정열;오현승
    • 산업경영시스템학회지
    • /
    • 제29권2호
    • /
    • pp.92-96
    • /
    • 2006
  • Large glass furnaces to produce glass for CRT are housed in huge chambers. It is costly to maintain such a chamber in constant temperature, humidity, and(air) pressure. In this study, first, we show that the process of such a huge furnace, which requires the steady maintenance of high temperature, is badly affected by the ambient temperature of surrounding air. Second, an alternative process which not only maintains the relatively constant temperature dispersion around the furnace, but is also economical will be proposed. We calculate the necessary volume of air inflow in the appendix.

Development of primary reference gas mixtures of 18 volatile organic compounds in hazardous air pollutants (5 nmol/mol level) and their analytical methods

  • Kang, Ji Hwan;Kim, Yong Doo;Lee, Jinhong;Lee, Sangil
    • 분석과학
    • /
    • 제34권5호
    • /
    • pp.202-211
    • /
    • 2021
  • Volatile organic compounds (VOCs) in hazardous air pollutants (HAPs) have been regulated by the Air Pollution Control Act (1978) and their atmospheric concentrations have been monitored in 39 monitor sites in Korea. However, measurement standards of volatile organic compounds (VOCs) in HAPs at ambient levels have not been established in Korea. Primary reference gas mixtures (measurement standards) at ambient levels are required for accurately monitoring atmospheric VOCs in HAPs and managing their emissions. In this study, primary reference gas mixtures (PRMs) at 5 nmol/mol were developed in order to establish primary national standards of VOCs in HAPs at ambient levels. Primary reference gas mixtures (PRMs) were prepared in pressurized aluminum cylinders with special internal surface treatment using gravimetric method. Analytical methods using gas chromatography-flame ionization detector (GC-FID) coupled with a cryogenic preconcentrator were also developed to verify the consistency of gravimetrically prepared HAP VOCs PRMs. Three different columns installed in the GC-FID were evaluated and compared for the retention times and separation of eighteen target components in a chromatogram. Results show that the HAP VOCs PRMs at 5 nmol/mol were consistent within a relative expanded uncertainty (k=2) of less than 3 % except acrylonitrile (less than 6 %) and the 18 VOCs were stable for 1 year within their associated uncertainties.

액화가스용 대기식 기화기의 외측 열전달 특성에 관한 연구 (A Study on Heat Transfer Characteristics of the Outside Surface of Ambient Vaporizer)

  • 강승모;서동민;고동국;최준호;박외철;임익태
    • 반도체디스플레이기술학회지
    • /
    • 제16권4호
    • /
    • pp.5-10
    • /
    • 2017
  • This paper analyzed the heat transfer characteristics on the outer surface of the ambient air vaporizer which received the heat from the air through natural convection by using numerical and experimental methods. The working fluid was a liquid nitrogen. The experimental variables were the length (2,000 mm, 1,800 mm, 1,600 mm) and width of the vaporizer fin and the fluid flow ($6.7m^3/h$, $7.1m^3/h$, $7.5m^3/h$). Based on the temperature data from the experiments, the heat transfer coefficient was calculated. Numerical analyses were also conducted in order to find the heat transfer coefficient for the range of Nusselt number which was difficult to get the data from experiments. The correlation equation between Nusselt number and Rayleigh number were suggested using both the experimental and numerical data.

  • PDF

Fin and Temperature Effect of Frost in Ambient Air Vaporizer

  • Lee, Seong-Woo;Choi, Sung-Woong
    • 한국해양공학회지
    • /
    • 제36권4호
    • /
    • pp.211-216
    • /
    • 2022
  • Since liquefied natural gas (LNG) is imported in a liquid state of about -162℃ to increase transportation efficiency in Korea, it must be vaporized in a gaseous state to supply it to consumers. Among them, ambient air vaporizer (AAV) has caught attention due to eco-friendly and low costs characteristics. However, there is a disadvantage that the performance of the heat exchanger is deteriorated due to frost due to mist and icing when used for a long time. In this paper, frost generation model in AAV vaporizer was investigated with numerically to examine utilizing the vaporizer performance with the frost generation behavior. The frost generation behavior of AAV vaporizers was examined with humidity, fin characteristic, and temperature effects. As for the LNG discharge temperature, the 12 fin vaporizer showed the highest discharge temperature when the atmospheric temperature was 25℃, and the 8 fin vaporizer had the lowest LNG discharge temperature when the atmospheric temperature was 0℃. In the case of frost formation, in the case of the 12 fin vaporizer, it was formed the most at the atmospheric temperature of 25℃, and the least was formed in the vaporizer at the 0℃ condition of the atmospheric temperature of 8 fins.

열펌프 성능향상을 위한 공기 열교환기 부착효과 (Attachment of the Air Heat Exchanger for COP Improvement in the Heat Pump)

  • 노정근;송현갑;박용규
    • Journal of Biosystems Engineering
    • /
    • 제27권3호
    • /
    • pp.235-240
    • /
    • 2002
  • Performance of the heat pump with attaching an air heat exchanger was investigated in the heating condition when the air heat exchanger was worked in the ambient air temperature of -5 to 11$\^{C}$ and air flow rate of 542 to 747 ㎡/h. Performance tests for heating condition were conducted in an experimental room equipped with heat pump. The performance tests were performed in a ambient temperature of -4 ∼ 11$\^{C}$, and room temperature of 4∼22$\^{C}$ respectively. Measured data(temperature, capacity of heat transfer and consumption of electronic power) were analyzed to the efficiency of HEEVA(Heat Exchanger fur the Evaporator), overall heat transfer coefficient and COP of heat pump. The results of inlet temperature for evaporator increased that the temperature was 2 ∼6$\^{C}$, and inlet temperature for condenser decreased that the temperature was 3 ∼ 8$\^{C}$. The results of comparing efficiency of HEEVA for the ratio of heat exchange between hot air and cold air showed that efficiency were considered to 91% because of the ratio of 83∼98%. The results of comparing of COP for the heat pump increased that improvement COP was approximately 0.3∼7.5 than HEEVA had not been operated.