• Title/Summary/Keyword: Alveolar Bone

Search Result 1,306, Processing Time 0.025 seconds

Insertion and removal torques according to orthodontic mini-screw design (교정용 미니스크류의 디자인에 따른 식립 및 제거 토오크)

  • Cha, Jung-Yul;Yoon, Tae-Min;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.38 no.1
    • /
    • pp.5-12
    • /
    • 2008
  • Objective: This study was designed to analyze the primary and secondary stability characteristics of orthodontic mini-screws of tapered design when compared with the cylinder mini-screw. Methods: A total of 48 mini-screws were placed into the buccal alveolar bone of the mandible in 6 male beagle dogs. Comparison was made between tapered and cylinder type mini-screws (Biomaterials Korea, Seoul, Korea). Maximum insertion torque (MIT) was measured using a torque sensor (Mark-10, MGT 50, USA) during installation, and maximum removal torque (MRT) was recorded after 3 and 12 weeks of loading. Results: Taper mini-screws showed a higher MIT value of 22.3 Ncm compared with cylinder mini-screw showing 13.6 Ncm (p < 0.001). The MRT of the taper mini-screw showed a significantly higher value of 9.1 Ncm than those of cylinder mini-screw of 5.7 Ncm at 3-weeks after installation (p < 0.05). However, there was no difference in the MRT value between the taper and cylinder mini-screws at 12 weeks of loading. Conclusions: These results showed that the high insertion torque of the taper mini-screw design increases initial stability until 3 weeks of loading, but does not have any effect on the secondary stability at 12 weeks of loading.

Study of the relationship between the indication rod of stent on implant CT and the real path of implant fixture insertion considering residual ridge (임플란트 CT에서 방향 표시자의 방향과 잔존골을 고려한 임플란트 식립 방향의 관계에 관한 연구)

  • Kim Do-Hoon;Heo Min-Suk;Lee Sam-Sun;Oh Sung-Ook;Choi Hang-Moon;Jeon In-Seong;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.33 no.2
    • /
    • pp.79-83
    • /
    • 2003
  • Purpose : To assess the relationship between the direction of the indicating rod of the radiographic stent for ideal prosthetic design and the actual possible path of implant fixture placement when residual ridge resorption is considered. Materials and Methods: The study materials consisted of 326 implant sites (male 214 cases and female 112 cases) from a total of 106 patients (male 65 patients and female 41 patients) who desired implant prostheses. Computed tomography of patients were taken and reformatted using ToothPix/sup (R)/ software. Bony defects, bony sclerosis, the change of the direction of indicating rod, and root proximity of the adjacent teeth were examined on the CT-derived images. Results: The rate of the irregular crestal cortex was relatively high on premolar and molar area of maxilla. Mandibular molar area showed relatively high rate of focal sclerosis on the area of implant fixture insertion. The position of the indicating rods were relatively acceptable on the molar areas of both jaws. However, the position of the indicating rods should be shifted to buccal side with lingual rotation of the apical end on maxillary anterior teeth and premolar area. Conclusion: Clinically determined rod direction and position of the indicating rod for implant placement was not always acceptable for insertion according to the reformatted CT images. The pre-operative treatment plan for implant should be determined carefully, considering the state of the alveolar bone using the reformatted CT images.

  • PDF

Full mouth rehabilitation of the patient with severe tooth erosion using collarless porcelain fused to gold restorations: a case report (Collarless 금속 도재 보철물을 이용한 심한 erosion 환자의 전악수복 증례)

  • Song, Hee-Jin;Lim, Young-Jun;Kwon, Ho-Beom;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.324-329
    • /
    • 2012
  • Excessive tooth wear causes loss of tooth structure, disharmony of occlusal plane, functional and esthetic problems. Although the decrease of occlusal vertical dimension may be compensated by growth of alveolar bone, if the length of tooth is not enough for the retention of restoration, minimum increase of occlusal vertical dimension is required without discomfort of the patient. In this case, 33-year-old woman drinks more than 1 liter of soft drinks a day and has bruxism in night time, visited in Seoul National University Dental Hospital with chief complaint of generalized tooth wear and related esthetic and functional problems. It was considered as a loss of occlusal vertical dimension based on the accelerated tooth wear caused by erosion and bruxism and facial appearance, phonetic, esthetic, functional evaluations. It was planned to raise occlusal vertical dimension by provisional restoration two times for patient's adaptation, 3 mm and 2 mm each, total 5 mm. Confirming no discomfort and clinical symptom during total 16 weeks after restoration with provisional fixed restoration, it was restored with porcelain fused to gold crown and bridge. Because the patient was young woman, anterior teeth were restored with collarless porcelain fused to gold crown. This case presents that satisfactory esthetic and functional result by full mouth rehabilitation with increase of occlusal vertical dimension.

A STRAIN GAUGE ANALYSIS OF IMPLANT-SUPPORTED CANTILEVERED FIXED PROSTHESIS UNDER DISTAL STATIC LOAD

  • Sohn, Byoung-Sup;Heo, Seong-Joo;Chang, Ik-Tae;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.717-723
    • /
    • 2007
  • Statement of problem. Unreasonable distal cantilevered implant-supported prosthesis can mask functional problems of reconstruction temporarily, but it can cause serious strain and stress around its supported implant and surrounding alveolar bone. Purpose. The purpose of this study was to evaluate strain of implants supporting distal cantilevered fixed prosthesis with two different cantilevered length under distal cantilevered static load. Material and methods. A partially edentulous mandibular test model was fabricated with auto-polymerizing resin (POLYUROCK; Metalor technologies, Stuttgart, Swiss) and artificial denture teeth (Endura; Shofu inc., Kyoto, Japan). Two implants-supported 5-unit screw-retained cantilevered fixed prosthesis was made using standard methods with Type III gold alloy (Harmony C&B55; Ivoclar-vivadent, Liechtenstein, Germany) for superstructure and reinforced hard resin (Tescera; Ivoclar-vivadent, Liechtenstein, Germany) for occlusal material. Two strain gauges (KFG-1-120-C1-11L1M2R; KYOWA electronic instruments, Tokyo, Japan) were then attached to the mesial and the distal surface of each standard abutment with adhesive (M-bond 200; Tokuyama, Tokyo, Japan). Total four strain gauges were attached to test model and connected to dynamic signal conditioning strain amplifier (CTA1000; Curiotech inc., Paju, Korea). The stepped $20{\sim}100$ N in 25 N increments, cantilevered static load 8mm apart (Group I) or 16mm apart (Group II), were applied using digital push-pull gauge (Push-Pull Scale & Digital Force Gauge, Axis inc., Seoul, Korea). Each step was performed ten times and every strain signal was monitored and recorded. Results. In case of Group I, the strain values were surveyed by $80.7{\sim}353.8{\mu}m$ in Ch1, $7.5{\sim}47.9{\mu}m/m$ in Ch2, $45.7{\sim}278.6{\mu}m/m$ in Ch3 and $-212.2{\sim}718.7{\mu}m/m$ in Ch4 depending on increasing cantilevered static load. On the other hand, the strain values of Group II were surveyed by $149.9{\sim}612.8{\mu}m/m$ in Ch1, $26.0{\sim}168.5{\mu}m/m$ in Ch2, $114.3{\sim}632.3{\mu}m/m$ in Ch3, and $-323.2{\sim}-894.7{\mu}m/m$ in Ch4. Conclusion. A comparative statistical analysis using paired sample t-test about Group I Vs Group II under distal cantilevered load shows that there are statistical significant differences for all 4 channels (P<0.05).

THE STUDY ON THE DEVELOPMENT OF RELATIVE VALUE IN MEDICAL TREATMENT OF THE ORAL AND MAXILLOFACIAL SURGERY (구강악안면외과 의료행위 상대가치 개발에 대한 조사연구)

  • Song, Gin-Ah;Baek, Kyung-Won;Hwang, Jong-Min;Yu, Soon-Yong;Choi, Jin-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.4
    • /
    • pp.334-347
    • /
    • 2006
  • The aim of this study is to evaluate the reasonableness of the medical fee on oral and maxillofacial surgery field according to surgeon's opinions and actual conditions. The medical fee has significant influence on hospital income, the supply and distribution of medical manpower, quality and facilities of medical services. Questionnaire survey was sent to 86 oral and maxillofacial surgeons who worked more than 3 years in general hospital. Among them, 25 doctors replied the 109 answers survey and the average of treatment time and physician work relative value on each category was calculated. And the health insurance cost (that has been applied since 2003) was compared with the questionnaire results. And finally we investigated items that health insurance system did not include in oral and maxillofacial field but actually performed in oral and maxillofacial surgery clinic. The result was that the medical fee did not properly reflect physician work relative value of actual treatments. In case of complicated extraction, work relative value needed 3.5 times enhancement of present value. For simple impacted tooth extraction 1.8 times, for impacted tooth extraction including odontomy 1.7 times, and for fully impacted tooth more than 2/3 of it located into the alveolar bone, 1.8 times enhancement needed. In respect of the present physician work relative value, hemimandibulectomy with neck lymph node dissection for the malignancy is appropriated as 3.3 times of open reduction and internal fixation for the mandibular fracture, but the questionnaire result showed 25 times discrepancy. In conclusion, this research shows the need for intervention that health insurance included items and legal relative medical value must act in union with treatment in clinic to reduce the imbalance between them.

INCIDENCE OF SINUS SEPTA AND ACCURACY OF PANORAMIC RADIOGRAPH (상악동 중격의 발생율과 파노라마 방사선 사진의 정확도)

  • Shin, Chang-Hoon;Kim, Hyung-Jin;Hong, Jong-Rak;Yang, Seung-Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.504-510
    • /
    • 2007
  • Purpose: The purpose of this study was to determine the incidence of antral septa and the accuracy of panoramic radiograph in identifying maxillary sinus septa. In addition, when panoramic radiograph led to a false diagnosis of more than majority, we analyzed findings of the panoramic radiograph. Patients and methods: This study included 180 patients who were radiographically examined before the surgery was done using both panoramic and computerized tomographic radiographs(CT scan), Samsung Medical Center from April 2003 to March 2006, and examined the incidence of antral septa, the false diagnosis rate of panoramic radiograph, and radiographic characters in case of false diagnosis. Only those bone lamellae were considered as septa that showed a height of at least 3.0mm. It was thus possible to exclude the alveolar recess. One oral and maxillofacial surgeon(OMFS) determined the presence or absence of sinus septa in CT scan, and five OMFS determined the presence or absence of sinus septa in panoramic radiograph. Results: The septa were observed in 81 of 360 sinuses(22.5%). All septa were oriented in a buccopalatal plane. More or less greater prevalence was observed in the second molar region(38.2%) but no predominant location was found. Panoramic radiograph led to false diagnosed septa in 361 of 1800 cases(20.1%). In case of false diagnosis of more than majority, superimposed image on zygomatic process was 44.1%, faint image in the region not related to sinus lifting 26.5%, faint image in the region related to sinus lifting 17.6%, and misconception for superimposed image 11.8% Conclusion: In this study we could get clinico-anatomical information of septum in the maxillary sinus. Compared to CT scan, panoramic radiograph can not clearly differentiate the sinus septa, but we consider that panoramic radiograph may improve its usefulness if we take additional modified panoramic radiograph and clinical exam.

Fabrication of suction denture by using the individual tray duplicated an existing denture through scan and milling process: A case report (스캔 및 밀링을 통해 기존 의치를 복제한 개인트레이를 이용한 흡착식 의치 제작 증례)

  • Park, Minhyuk;Kee, Wonjin;Yang, Hongso;Park, Sang-Won;Yun, Kwi-Dug;Park, Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.221-227
    • /
    • 2020
  • In the case of complete edentulous patients, as the mandibular alveolar bone absorption progresses, the maintenance and stability of the existing dentures, which had satisfactory functions in the past, are deteriorated. Despite of the need to fabricate new dentures, they often hesitate due to physical burdens on the duration and intensity of future treatment progress due to the effects of aging and systemic diseases. In the case of these completely edentulous patients, it is necessary to consider the treatment goals that can reduce the number of visits and the adaptation period for new dentures before starting the treatment. This case is a case of producing complete dentures of elderly patients with deteriorated physical ability. In addition to producing suction dentures through preliminary and definitive closed mouth functional impression suggested by Sato, CAD / CAM technique was used to transfer occlusal functional information of existing dentures to facilitate adaptation to new dentures.

Orthodontic protraction of the third molars to the posterior teeth missing area (구치 결손 환자에서 제3대구치의 교정적 활용)

  • Lee, Kang-gyu;Park, Je-Hyeok;Jeon, Jin;Kang, Jae-yoen;Kim, Jong Ghee;Jeon, Young-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.4
    • /
    • pp.260-269
    • /
    • 2019
  • The prolonged neglect of the posterior teeth missing area may cause mesial drift, extrusion, unexpected movement of the adjacent teeth and alveolar bone loss with occlusion collapse. Therefore it is recommended to treat that area by the prosthesis as soon as possible after tooth missing. However, if orthodontic treatment is applied to move the remained teeth, it can create improved biomechanical dentoalveolar environment. The use of the third molars in teeth missing area provides advantages as optimizing of prosthesis size. However, crown shape, location, soundness of the third molar and possible of eruption failure should be considered. In this case report, two patients closed a second teeth missing site and reduced the size of the first and second teeth missing area for an implant by protraction of impacted third molars. This case reports the considerations for closing or reducing the posterior teeth space with protracting the third molars by comparing two patients.

Strategic surgical-combined orthodontic treatment planning of patient with missing incisors on maxilla: a case report (상악 전치부 결손 환자의 수술을 동반한 전략적 교정치료 증례)

  • Park, Je-Hyeok;Jeon, Jin;Zhao, Sen;Jeon, Young-Mi;Kim, Jong Ghee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.4
    • /
    • pp.244-252
    • /
    • 2019
  • Proper positioning of maxillary incisors is key to success of surgery combined treatment. Establishing surgery plan would be a difficult job if maxillary incisors are lost. Patient who lost all of her maxillary incisors due to accident came for orthodontic treatment. Through careful modification of maxillary archform, pre-surgical orthodontic treatment was conducted with four prosthetic space consolidation. Position of incisors was decided by help of 3D prosthetic set-up, and 1-jaw surgery was planned. After relative short treatment period of 28 months, final prosthesis was done. When alveolar bone loss happens, harmonious prosthesis of upper incisors is difficult. Utilizing mandibular set-back surgery and incisor positioning using 3D set-up could make a better environment for treatment outcome. Strategic pre-surgical orthodontic treatment can allow shorter time and less number of prosthetics.

Treatment of crown-root fracture with a modified crown fragment reattachment technique (변형된 치관부 파절편 재부착술식을 이용한 치관치근파절의 치료)

  • Song, Chang-Won;Song, Min-Ju;Shin, Su-Jung;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.395-400
    • /
    • 2010
  • The development of adhesive dentistry has allowed that the crown fragment reattachment can be another option in the treatment of crown fracture. However, additional crown lengthening procedure or extrusion of the tooth may be necessary in the treatment of crown root fracture because subgingival fracture line in close proximity to the alveolar bone leads to challenges for restorative procedure and the violation of the biologic width. This case report presents a modified crown fragment reattachment technique of crown root fracture with pulp exposure, which was done without additional crown lengthening procedures. After the endodontic treatment, the patient was treated using a post insertion and the fragment reattachment technique, which made it possible to preserve the space for the biologic width and maintain a dry surgical field for adequate adhesion through the modification of the fractured coronal fragment. Since a coronal fracture was occurred and reattached afterward, it was observed that the coronal fragment was well maintained without the additional loss of periodontal attachment through 2-year follow up.