• Title/Summary/Keyword: Aluminium Filter

Search Result 28, Processing Time 0.023 seconds

A Study on Filter Effect on Improvement of Chest Radiography (Filter effect를 이용(利用)한 Chest Radiography)

  • Hayaahi, Taro;Ishida, Yuzi
    • Journal of radiological science and technology
    • /
    • v.7 no.1
    • /
    • pp.23-33
    • /
    • 1984
  • In the present study, we determined reduction value of radiation on chest film by film method and made a reduction curves. The reduction radio in exposure to radiation was induced by comparative investigation of characteristic curves and reduction one. Basing on these result, we could reduce a radiation dose on body surface in 50% at the time of chest radiography, if 17.8mm aluminium or 0.87mm copper filter were used in addition to conventional filter at 140KV tube voltage. The present study further revealed that the additional use of the aluminium or copper filter at the time of high voltage radiography in chest facilitates to identify an image of some pathologic focus overlapping wist clavicle and ribs.

  • PDF

Used the Computer Vision System Develop of Algorithm for Aluminium Mill Strip Defect Inspection (컴퓨터 비젼 시스템을 이용한 알루미늄표면 검사 알고리즘 개발)

  • 이용중
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.115-120
    • /
    • 2000
  • This study is on the application the image processing algorithm for inspection of the aluminium mill strip surface defect. The image of surface defect data was obtained using the CCD camera with the digital signal board. The edge was found from the difference of pixel intensity between the normal image and defect image. Two step were taken to find the edge in the image processing algorithm. First, noise was removed by using the median filter in the image. Second, the edge was sharpened in detail by using the sharpening convolution filter in the image. Canny algorithm was used to defect the exact edge. The defect section was separated from the original image is to find the coordination point p1 and p2 which include the defect image

  • PDF

A Study on the Effect of Rare Earth Screen Filter (희토류 증감지를 이용한 여과판의 효과)

  • Huh, Joon;Kim, Chang-Kyun;Lee, In-Ja;Shin, Wha-Soo;Park, Jun-Chul;Kang, Hong-Seok;Ahn, Bong-Seon
    • Journal of radiological science and technology
    • /
    • v.11 no.1
    • /
    • pp.17-23
    • /
    • 1988
  • As the reutilizing method of exhausted screen, authors used it as a filter and compared with the aluminium filtration. The results are as followed; 1. One sheet of gadolinium front screen has the same radiation absorption as $2.8{\sim}3.3\;mm$ Al equivalent and regular tungsten screen $2.3{\sim}2.7mm$ Al. 2. HVL after Gd-screen filtration was less than the values after aluminium and tungsten-screen filtration. And, image definition with Gd-screen filtration was better than other two cases. Ana surface dose to produce a same film density was more than other two cases. It will be very useful to apply, Gd-screen filter in clinics as it has no deficiency of image quality.

  • PDF

The corrosion of aluminium alloy and release of intermetallic particles in nuclear reactor emergency core coolant: Implications for clogging of sump strainers

  • Huang, Junlin;Lister, Derek;Uchida, Shunsuke;Liu, Lihui
    • Nuclear Engineering and Technology
    • /
    • v.51 no.5
    • /
    • pp.1345-1354
    • /
    • 2019
  • Clogging of sump strainers that filter the recirculation water in containment after a loss-of-coolant accident (LOCA) seriously impedes the continued cooling of nuclear reactor cores. In experiments examining the corrosion of aluminium alloy 6061, a common material in containment equipment, in borated solutions simulating the water chemistry of sump water after a LOCA, we found that Fe-bearing intermetallic particles, which were initially buried in the Al matrix, were progressively exposed as corrosion continued. Their cathodic nature $vis-{\grave{a}}-vis$ the Al matrix provoked continuous trenching around them until they were finally released into the test solution. Such particles released from Al alloy components in a reactor containment after a LOCA will be transported to the sump entrance with the recirculation flow and trapped by the debris bed that typically forms on the strainer surface, potentially aggravating strainer clogging. These Fe-bearing intermetallic particles, many of which had a rod or thin strip-like geometry, were identified to be mainly the cubic phase ${\alpha}_c-Al(Fe,Mn)Si$ with an average size of about $2.15{\mu}m$; 11.5 g of particles with a volume of about $3.2cm^3$ would be released with the dissolution of every 1 kg 6061 aluminium alloy.

Analysis of Effectiveness of Spectrum of Energy and Image Quality Evaluation by Aluminium Filter in the added Compound Filtration (에너지 스펙트럼과 화질평가를 통한 복합부가여과에서 알루미늄 여과판의 효율성 분석)

  • Kim, Sang-Hyun;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.187-197
    • /
    • 2015
  • This study analysed the effectiveness of aluminium(Al) filter in the added compound filtration for the removal of characteristic radiation by energy spectrum and image evaluation. 0.1, 0.2, 0.3 mm copper with and without 1 mm Al were evaluated. The energy spectrum was measured using the GATE and evaluated separately by each energy. Image quality was evaluated by PSNR, MAE, MSE, CNR, SNR and qualitative analysis was performed by seven items for resolution and contrast from chest x-ray criteria of National Cancer Screening and Cardiovascular evaluation table. In the analysis of the quality of the energy per photon spectrum with the exception of a low energy region, without Al were superior in all area. PSNR MAE, MSE, CNR, SNR and qualitative analysis were the same or slightly better. PSNR was over 30 dB and all significant and the p>0.05 in the T-test of qualitative analysis. The energy spectrum and image quality have little difference between before and after use of Al filter. Therefore, it is effective to use the Al filter for the radiation dose management with the compensation capability of DR system.

A Analysis of Effectiveness of Aluminium Filter in the added Compound Filtration by Detective Quantum Efficiency and Image Quality Evaluation (복합부가여과에서 알루미늄 여과판 사용 시 양자검출효율과 화질평가를 통한 효율성 분석)

  • Kim, Sang-Hyeon;Kim, Yun-Min;Kwon, Kyoung-Tae;Ma, Sang-Chull;Han, Dong-Gyoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.10
    • /
    • pp.362-373
    • /
    • 2015
  • This study analysed the effectiveness of aluminium(Al) filter in the added compound filtration for the removal of characteristic radiation from high atomic number material by DQE and image evaluation. 1mm Al was applied to each 0.1, 0.2, 0.3 mm copper and befere and after use were evaluated. Beam quality and DQE were tested by IEC regulations and image quality was evaluated by PSNR, MAE, MSE, CNR, SNR and qualitative analysis was performed by 7 items for resolution and contrast from chest x-ray criteria of national cancer checkup. MTF 10 and 50% were the same by 4.6, 2.54 cycle/mm and NPS, DQE, PSNR MAE, MSE, CNR, SNR and qualitative analysis were all the same or slightly better when Al was not used. PSNR is over 30dB and all significant and at the qualitative analysis, the p-value of t-test was over 0.05. The DQE and image quality evaluation have little difference between before and after use of Al filter and it is effective to use the Al filter for the reduction of skin dose by removal of characteristic radiation.

Effects of mold temperature on the part dimension and surface quality of the injection molded cavity filter (금형온도가 Cavity Filter 성형품의 치수 및 외관품질에 미치는 영향에 관한 연구)

  • 김동학;김태완
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.164-167
    • /
    • 2003
  • In this study, we developed the mold for the plastic cavity filter which is a kind of a wireless communication device. Since the cavity filter is made of aluminium, the cost of fabrication is high and the production rate is low. But we can produce plastic cavity filter part by injection molding process with the mold which was designed by our team. The dimension and surface quality of plastic cavity filter was investigated by varying the molding method (conventional and MmSH process) and two different types of resin(PC/ABS and ABS). In case of ABS part, the shrinkage of the inner partition walls was decreased when we adopted MmSH method. The weight of both ABS and PC/ABS parts increased and the surface roughness decreased with MmSH process.

  • PDF

Removal Efficiency Study of Aromatic Hydrocarbons Using a High-Temperature Fiber Filter on a Laboratory Scale (실험실 규모에서 고온 섬유 여과재를 이용한 방향족 유기화합물 제거 특성 조사)

  • Lee, hak-Sung;Kang, Byung-Wook;Lee, Sang-Kwun;Han, Young-Wook;Han, Bum
    • Journal of Environmental Science International
    • /
    • v.8 no.4
    • /
    • pp.473-477
    • /
    • 1999
  • The purpose of this study was to investigate the characteristics of removal efficiency for aromatic hydrocarbons using a high-temperature fiber filter on a laboratory scale. The main elemental compositions of a high-temperaure fiber filter are aluminium and silica, which can act as the catalysts. Benzene, toluene and o-xylene among aromatic hydrocarbons were used in this experiment. For 3cm thickness of fiber filter, these compounds were removed more than 90% at the face velocities of 3cm/sec and 5cm/sec above 45$0^{\circ}C$. For 4cm thickness of it, the removal efficiencies of these compounds were almost 90% from 40$0^{\circ}C$ at the same face velocities, suggesting that it may be due to increasing the contact time between the fiber filter and aromatic hydrocarbons. The pressure droop ranged from 22 to 48mmH2O for 3cm thickness of fiber filter. However, for 4cm thickness of it, it was about two times(41~89mm$H_2O$) higher than that for 3cm fiber thickness.

  • PDF

Film Bulk Acoustic Resonator(FBAR) using Bragg Reflector for IMT-2000 Bandpass Filter (Bragg 반사층을 이용한 IMT-2000 대역통과필터용 체적 탄성파 공진기)

  • 김상희;김종헌;박희대;이시형;이전국
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.377-382
    • /
    • 2000
  • Film bulk acoustic resonator (FBAR) using AIN reactively sputtered at room temperature was fabricated. The FBAR is composed of a piezoelectric aluminium nitride thin film, top electrode of Al and bottom electrode of Au connected by a short (200${\mu}{\textrm}{m}$) transmission line on both sides and reflector layers of SiO$_2$- W Pair. The active areas of Al and Au were patterned using 150${\mu}{\textrm}{m}$ diameter shadow mask. The series resonance frequency (fs) and the parallel resonance frequency (fp) were measured at 1.976 GHz and 2.005 GHz, respectively. The minimum insertion loss and return loss were 6.1 dB and 37.19 dB, and the quality factor (Q) was 4261.

  • PDF

Development of Filter Replacement Type Mask by Natural Dyeing of Gallnut (오배자 천연염색을 적용한 필터교체형 면마스크 개발)

  • Kim, Minseo;Song, Hyunjoo;Lee, Sohee
    • Textile Coloration and Finishing
    • /
    • v.32 no.4
    • /
    • pp.199-207
    • /
    • 2020
  • Recently, as the demand for masks increases, the use of filter-replaceable cotton masks is increasing. A filter-replaceable cotton mask is one of the ways to solve the environmental problems of a disposable nonwoven mask because only the filter can be replaced after washing. Cotton fiber products are known to be environmentally friendly, but cotton products dyed with general synthetic dyes are not safe for humans. In this study, to prepare of cotton mask applied with natural dyeing, the optimal dyeing conditions are set when dyeing with gallnut extract. A polychromatic natural dye that changes color by mordant, and the functionalities of gallnut dyeing fabrics are evaluated. The experimental method is dyed the gallnut by temperature and time by concentration to set the optimal conditions. The color fastness rating grade of aluminium potassium sulfate dodecahydrate, copper(ll) sulfate pentahydrate, and iron(ll) chloride tetrahydrate were evaluated after the pre/post mordanting.