• 제목/요약/키워드: Alumina Ceramic

검색결과 877건 처리시간 0.027초

Nucleation of CVD Diamond on Various Substrate Materials

  • Fukunaga, O.;Qiao, Xin;Ma, Yuefei;Shinoda, N.;Yui, K.;Hirai, H.;Tsurumi, T.;Ohashi, N.
    • The Korean Journal of Ceramics
    • /
    • 제2권4호
    • /
    • pp.184-187
    • /
    • 1996
  • Diamod nucleation by mw assisted CVD was examined various conditions namely, (1) diamond nucleation on variour substrate materials, such as Si, cubic BN, pyrolytic BN and AIN, (2) AST(Activated species transport) method which promote nucleation of diamond on single crystal and polycrystalline alumina substrate was developed. (3) Effect of bias enhancement of nucleation on single crystalline Si was examined, and finally (4) DST (Double step treatment) method was developed to enhance diamond nucleation on Ni. In this method, we separated carbon diffusing process into Ni, carbon precipitating process from the inside of Ni and diamond precipitation process.

  • PDF

세라믹스 가공용 다이아몬드 공구 마모에 관한 연구 (A Study on the Wearing Behavior of Diamond Tool used to Machining of Ceramics)

  • 박상희;김광민;최성대;홍영배
    • 한국기계가공학회지
    • /
    • 제10권1호
    • /
    • pp.73-79
    • /
    • 2011
  • In this study, coring with diamond core drill on the sintered $Al_2O_3$ ceramic plate were carried out with different coring conditions such as various cutting speed and feed rate to evaluate their effectiveness on the wearing behavior of diamond tool and coring quality. The wearing rate of diamond core drill were getting better with increasing cutting speed and feed rate but the quality of cored hole were getting worse as increasing cutting speed and feed rate.

Design of Implantable CPW Fed Monopole Antenna for ISM Band Applications

  • Kumar, S. Ashok;Shanmuganantham, T.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권2호
    • /
    • pp.55-59
    • /
    • 2014
  • An implantable CPW fed monopole antenna embedded into human tissue is proposed for ISM band biomedical applications. The proposed antenna is made compatible for implantation by embedding it in an alumina ceramic substrate (${\Box}_r=9.8$ and thickness=0.65 mm). The proposed antenna covers the ISM band of 2.45 GHz. The radiation parameters, such as return loss, E-Plane, H-Plane, are measured and analyzed, using the method of moments. The proposed antenna has substantial merits over other implanted antennas, like low profile, miniaturization, lower return loss, and better impedance matching and high gain.

세라믹 기판을 이용한 반도체 보호용 휴즈 엘리먼트에 관한 연구 (A Study on the fuse elements for the protection of a semiconductor using a ceramic substrate)

  • 이세현;한상옥;김종석;이신현;성기선;권영훈;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.762-764
    • /
    • 1992
  • This Paper presents some experimental result of current limiting and short circuit interruption behavior of thin copper film, 12${\mu}m$, 25${\mu}m$, 40${\mu}m$, 50${\mu}m$ on alumina substrate. and a fuse-link having elements of copper film provided with high-precision small hols with electrolytical process. Construction, fabrication, as well as the test circuitry built especially for the develoment of this fuse-links are explained below.

  • PDF

Design and Performances of Implantable CPW Fed Apollian Shaped Antenna at 2.45 GHz ISM Band for Biomedical Applications

  • Kumar, S. Ashok;Sankar, J. Navin;Dileepan, D.;Shanmuganantham, T.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권5호
    • /
    • pp.250-253
    • /
    • 2015
  • A novel implantable CPW fed Apollian shaped antenna embedded into human tissue is proposed for ISM band biomedical applications. The proposed antenna is made compatible for implantation by embedding it in an alumina ceramic substrate(εr=9.8 and thickness= 0.65 mm). The proposed antenna covers the ISM band of 2.45 GHz. The radiation parameters such as return loss, xy-plane, xz-plane, and yz-plane etc., are measured and analyzed using the agilent vector network analyzer. The proposed antenna has substantial advantages, including low profile, miniaturization ability, lower return loss, better impedance matching, and high gain over conventional implanted antennas.

산소 분리를 위한 무공성 세라믹- 금속 복합 무기막 (Dense Ceramic-metal Composite Inorganic Membranes for Oxygen Separation)

  • 김진수
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2002년도 춘계 총회 및 학술발표회
    • /
    • pp.35-41
    • /
    • 2002
  • Dense oxygen ionic conducting materials can be used for oxygen separation membranes at high temperatures. However, they show relatively low permeation flux because of their large resistances. To reduce resistances and improve the oxygen permeation flux, thin dense yttria-stabilized-zirconia (YSZ)/Pd composite dual-phase membranes were fabricated by a new approach that combines the reservoir method and chemical vapor deposition (CVD). A thin porous YSZ layer was coated on a porous alumina support by dip-coating the YSZ suspension. A continuous Pd phase was formed inside pores of the YSZ layer by the reservoir method. The residual pores of the YSZ/Pd layer were plugged with yttria/zirconia by CVD to ensure the gas tightness of the membranes. The oxygen permeation fluxes through these composite membrane were 2.0$\times$10$^{-8}$ mol/cm$^2$.s and 4.8$\times$10$^{-8}$ mol/cm$^2$.s at 105$0^{\circ}C$ when air and oxygen were used as the permeate gases, respectively. These oxygen permeation values are about 1 order of magnitude higher than those of pure YSZ membranes prepared under similar conditions.

  • PDF

Application of Mechanoluminescence for the Dynamic Visualization of an Alumina Fracture

  • Kim, Ji-Sik
    • Journal of Information Display
    • /
    • 제11권1호
    • /
    • pp.33-38
    • /
    • 2010
  • The propagation of cracks was quantitatively analyzed in $Al_2O_3$ ceramic using the mechanoluminescence (ML) of $SrAl_2O_4$:Eu,Dy. The bridging zones behind the crack tip were clearly detected in the crack path of $Al_2O_3$ within a realistic time frame. The magnitudes and shapes of the bridging stress distributions changed with the advancing cracks. They continued to change with the change in the applied load even after the cessation of crack propagation. Effective toughening then commenced, and the applied stress intensity factors dramatically increased up to ~50 MPa $\sqrt{m}$. The expected $K_{Tip}$ values based on the instantaneous bridging stress distributions obtained from the ML observations deviated greatly from those obtained from the measurement using the conventional crack tip lengths; rather, they support the results obtained when bridging tips were used in the quasidynamic crack propagations.

펨토초 레이저 어블레이션을 이용한 알루미나 세라믹 기판의 정밀 마이크로 드릴링 (Precision microdrilling of alumina ceramic substrates by femtosecond laser ablation)

  • 김성훈;손익부;노영철;이종민;정성호
    • 한국레이저가공학회지
    • /
    • 제11권1호
    • /
    • pp.25-31
    • /
    • 2008
  • The characteristics of femtosecond laser ablation of $Al_2O_3$ for prescision microfabrication are studied experimentally. Specifically, the process time during femtosecond laser drilling of microholes with $sub-100{\mu}m$ diameter are investigated for varying laser fluence, scan speed and beam path designs like trepanning with continuously changed start points. The accumulation of sub-micrometer size particles within the hole and the deterioration of edge clarity and roundness for decreasing hole diameter are examined and through process optimization the microdrilling with good hole quality is achieved using a femtosecond laser system (repetitionrate 1 kHz, wavelength 785 nm, pulse duration 185 fs)

  • PDF

HC 센서를 이용한 자동차 배기가스 감지 연구 (Development of HC Sensor & System for Vehicles Exhaust Gas Check)

  • 전영갑;조국희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1011-1014
    • /
    • 1999
  • An on-board monitoring system for an automobile emission gas has a test chamber remote from the automobile's engine exhaust gas stream: apparatus for supplying the chamber with sampled exhaust gases. A single hydrocarbon sensor exposed to the exhaust gas in the chamber to render a signal responsive to the hydrocarbon. The conductive ions in emission gas was checked by the HC sensor in test chamber. A preferred application includes hydrocarbons in an automotive exhaust gas stream by exposing a transition porous alumina($Al_{2}O_{3}$) ceramic based sensor to the same exhaust gas stream. By combining the electrical signal, a measure of hydrocarbons can be provided.

  • PDF

콜로이달 실리카로 결합된 알루미나 세라믹 쉘 몰드의 강도에 미치는 요인 (Factors Influencing the Strength of Alumina Ceramic shell Molds Bound with Colloidal Silica)

  • 강종봉;문종수;조범래;최승주;김학믹
    • 한국재료학회지
    • /
    • 제6권12호
    • /
    • pp.1179-1185
    • /
    • 1996
  • 고온용 세라믹 쉘 몰드를 용융 알루미나와 콜로이달 실리카를 사용하여 제조한 후, 세라믹 쉘 몰드의 강도에 영향을 주는 요인을 분석하였다. 세라믹 쉘 몰드의 강도는 바인더의 실리카 입자의 크기가 작을수록 크며 또한 실리카 농도에 비례하여 증가함을 보이며 저온에서의 강도 발현은 콜로이달 실리카의 필름 형성에 의한 입자들의 결합임을 알 수 있었다. 세라믹 쉘 몰드의 소성 강도는 부착 스타코의 크기가 작을수록 크며 소성 온도에 비례하여 증가함을 보였다. 고온에서의 강도 발현은 알루미나 입자와 콜로이달 실리카 바인더의 결합뿐만 아니라 알루미나 입자사이의 결합도 영향을 줌을 알 수 있었다. 쉘 몰드의 결정상은 130$0^{\circ}C$이하에서 소성한 경우 $\alpha$-알루미나만 존재함을 보여 실리카는 비정질로 계속 남아 있음을 알 수 있고 140$0^{\circ}C$ 이상에서 소성한 경우 뮬라이트가 생성됨을 보였다.

  • PDF