• 제목/요약/키워드: Alternating type

검색결과 160건 처리시간 0.022초

ON THE STRUCTURE OF THE GRADE THREE PERFECT IDEALS OF TYPE THREE

  • Choi, Eun-Jeong;Kang, Oh-Jin;Ko, Hyoung-June
    • 대한수학회논문집
    • /
    • 제23권4호
    • /
    • pp.487-497
    • /
    • 2008
  • Buchsbaum and Eisenbud showed that every Gorenstein ideal of grade 3 is generated by the submaximal order pfaffians of an alternating matrix. In this paper, we describe a method for constructing a class of type 3, grade 3, perfect ideals which are not Gorenstein. We also prove that they are algebraically linked to an even type grade 3 almost complete intersection.

MATHIEU-TYPE SERIES BUILT BY (p, q)-EXTENDED GAUSSIAN HYPERGEOMETRIC FUNCTION

  • Choi, Junesang;Parmar, Rakesh Kumar;Pogany, Tibor K.
    • 대한수학회보
    • /
    • 제54권3호
    • /
    • pp.789-797
    • /
    • 2017
  • The main purpose of this paper is to present closed integral form expressions for the Mathieu-type a-series and its associated alternating version whose terms contain a (p, q)-extended Gauss' hypergeometric function. Certain upper bounds for the two series are also given.

Electrical properties of ABS resin reinforced with recycled CFRP

  • Nishikawa, Takashi;Ogi, Keiji;Tanaka, Toshiro;Okano, Yasutaka;Taketa, Ichiro
    • Advanced Composite Materials
    • /
    • 제16권1호
    • /
    • pp.1-10
    • /
    • 2007
  • Composite materials consisting of crushed carbon fiber reinforced plastics (CFRP) pieces and acrylonitrile-butadiene-styrene (ABS) resin were prepared by an injection mold method to solve the problem of recycling of CFRP. The electrical properties, such as electrical resistivity, alternating current impedance and electromagnetic interference (EMI) shielding effect, were measured for the composites. The electrical resistivity of the composites showed a percolation type of conduction behavior and no difference between parallel and perpendicular to the injection direction was observed for CFRP content higher than the critical value. Measurement of alternating current impedance revealed that the conduction mechanism is attributed to the direct conductive paths generated by distributed carbon fibers; however, strong frequency dependence of the impedance was observed for the CFRP content near the critical one. The frequency dependence of the impedance is caused by the inter-fiber connection and can be expressed as a simple equivalent circuit. The absorption component of shielding effect (SE) was smaller than the expected value estimated from its resistivity. The decline of SE is thought to be caused by the decrease in effective thickness due to fiber orientation.

교류 전압 구동에 의한 유기 발광 소자의 발광 특성 연구 (Light-Emission Characteristics of Organic Light-Emitting Diodes Driven by Alternating Current)

  • 권오태;김태완
    • 한국전기전자재료학회논문지
    • /
    • 제29권10호
    • /
    • pp.625-629
    • /
    • 2016
  • Electrical and optical properties of the AC voltage driven organic light-emitting diodes were investigated by measuring the electroluminescence of the device. Device structure of ITO(170 nm)/TPD(40 nm)/Alq3(60 nm)/LiF(0.5 nm)/Al(100 nm) was manufactured using a thermal evaporation. Sinusoidal and square-type AC voltage was applied to the device using a function generator. Amplitude of the applied voltage was 9.0 V, and a frequency was varied from 50 Hz to 50 kHz. Electroluminescence out of the device was measured in a Si photodetector simultaneously with the applied voltage together. An intensity and a delayed residual luminescence from the device were depended on the frequency of the sinusoidal voltage. It is thought to be due to a contribution of the capacitive nature in the equivalent circuit of the device. An electron mobility was estimated using a time constant obtained from the luminescence of the device driven by the square-type AC voltage.

Three-Dimensional Metal Complex Host with Alternating Arrangement of the Occupied and Vacant Channels. The Crystal Structure of Cd(NH₂CH(CH₃)CH₂NH₂)Ni(CN)₄· 0.25G (G=$CH_3C_6H_5, p-(CH_3)_2C_6H_4$)

  • 박기민;이욱;Toschitake Iwamoto
    • Bulletin of the Korean Chemical Society
    • /
    • 제17권10호
    • /
    • pp.919-924
    • /
    • 1996
  • Crystal structure of two inclusion compounds Cd(pn)Ni(CN)4·0.25G (G=toluene and p-xylene, pn=1,2-diaminopropane) have been determined from single-crystal X-ray diffraction data; toluene clathrate: monoclinic P21/n, a=13.838(6), b=26.893(5), c= 7.543(5) Å, γ=90.92(3)°, Z=4, R=0.0616; p-xylene clathrate: monoclinic P21/n, a=13.895(2), b=26.900(3), c=7.613(1) Å, γ=91.06(1)°, Z=4, R=0.0486. The host structures determined for toluene- and pxylene-guest clathrates are substantially identical to the U-type structures observed for the straight chain aliphatic-guest clathrates. However, the alternating arrangement of occupied channels with the guest molecules and vacant channels appears in the host structure. The non-centrosymmetric toluene molecules are distributed about the inversion center to give an image like p-xylene molecule. The guests, toluene and p-xylene, prefer the U-type channel, favoring the interaction between the π-electrons of the aromatic ring and the pn-amino groups to hold the aromatic ring vertical to the cyanometallate meshes.

영구자석형 모터의 고정자 철심에서 자계의 거동 및 철손 분석 (Analysis of Magnetic Field Behavior and Iron Loss in Stator Core of Permanent Magnet Type Motor)

  • 하경호;차상윤;김재관;홍정표
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권2호
    • /
    • pp.76-82
    • /
    • 2006
  • This paper investigates the magnetic field behavior and its iron losses in the stator core using electrical steels. The analysis model is a brushless motor with the permanent magnet. The elliptical rotating and alternating flux distributions with non-sinusoidal waveform are obtained by Finite Element Method and then their harmonic components are extracted. Based on these results, the local iron losses in the stator core caused by the harmonic flux are calculated. And then this paper explains the relation between flux waveform and iron loss produced in each part of the stator core. Furthermore, the iron loss at no load condition is measured and compared with the analysis results.

AN ASYMPTOTIC EXPANSION FOR THE FIRST DERIVATIVE OF THE HURWITZ-TYPE EULER ZETA FUNCTION

  • MIN-SOO KIM
    • Journal of applied mathematics & informatics
    • /
    • 제41권6호
    • /
    • pp.1409-1418
    • /
    • 2023
  • The Hurwitz-type Euler zeta function ζE(z, q) is defined by the series ${\zeta}_E(z,\,q)\,=\,\sum\limits_{n=0}^{\infty}{\frac{(-1)^n}{(n\,+\,q)^z}},$ for Re(z) > 0 and q ≠ 0, -1, -2, . . . , and it can be analytic continued to the whole complex plane. An asymptotic expansion for ζ'E(-m, q) has been proved based on the calculation of Hermite's integral representation for ζE(z, q).

Comparison of Three Magnet Array-type Rotors in Surface Permanent Magnet-type Vernier Motor

  • Kataoka, Yasuhiro;Takayama, Masakazu;Matsushima, Yoshitarou;Anazawa, Yoshihisa
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권1호
    • /
    • pp.1-8
    • /
    • 2013
  • Surface permanent magnet-type vernier motors with three magnet array-type rotors (parallel magnetized type, repulsion type, and Halbach type) are compared based on the pull-out torque. It was clarified that increasing the rotor radius increases the pull-out torque at a fixed three-phase alternating voltage. The mechanism for the pull-out torque increase on each magnet array type was different, when the effects of the increase were analyzed based on an induced electromotive force and a synchronous reactance. As a result, the design of the Halbach-type rotor was found to be especially effective for achieving high pull-out torque, because this array type achieves a large induced electromotive force $E_0$ and a small synchronous reactance $x_s$.

비복근 위축 토끼 모델에서 직류 및 교류 미세전류의 근육 재생 효과 비교 (Comparison of Regeneration Effects of Direct and Alternating Microcurrent Therapy on Atrophied Calf Muscle in a Rabbit)

  • 김동한;권동락;문용석
    • Clinical Pain
    • /
    • 제19권2호
    • /
    • pp.80-89
    • /
    • 2020
  • Objective: We compared the regenerative effects of microcurrent therapy (MT) according to the type of electric current, which were direct current microcurrent therapy (DCMT) and alternating current microcurrent therapy (ACMT) on atrophied calf muscle in cast-immobilized rabbit. Method: Rabbits were allocated into control group (sham MT), ACMT group, and DCMT group. Before starting treatment, right gastrocnemius (GCM) muscle was immobilized by cast for 2 weeks. Compound muscle action potential of tibial nerve in nerve conduction study, circumference of calf muscle using a ruler, and thickness of medial and lateral GCM muscle measured by ultrasound, cross sectional area (CSA), and proliferating cell nuclear antigen (PCNA) ratios (%) of muscle fibers were measured on the immunohistochemical analysis. Results: The mean atrophic changes (%) in right medial and lateral GCM muscle thickness, right calf circumference, and amplitude of CMAP of the right tibial nerve in ACMT group and DCMT group were significantly lower than those in control group, respectively (p<0.05). The mean CSA (μm2) of type I and type II and PCNA ratios (%) of medial and lateral GCM muscle fibers in ACMT group and DCMT group were significantly greater than those in control group, respectively (p<0.05). There were no significant differences between the ACMT group and DCMT group at all parameters. Conclusion: This study demonstrated that ACMT and DCMT showed better regeneration effect than sham MT. Microcurrent may be effective in regeneration of atrophied muscle regardless of the type of current.

APR+ 대체교류발전기의 가스터빈 적용에 대한 민감도분석 (Sensitivity Analysis for Using Gas Turbine Generator to Provide Alternate Alternating Current in APR+)

  • 문호림;박범락;박영섭
    • 대한기계학회논문집A
    • /
    • 제36권1호
    • /
    • pp.97-102
    • /
    • 2012
  • 원자력발전소의 대체교류발전기는 소내정전에 대처하기 위하여 설치되고 있다. 국내 원자력발전소에서 사용되고 있는 대체교류발전기의 구동형식은 대부분 디젤발전기이다. 가스터빈은 디젤발전기보다 구조가 간단하고 유지정비주기가 길다는 장점이 있지만 국내 원자력발전소에 적용사례가 없다는 단점이 있다. 본 논문의 목적은 APR+ 대체교류발전기의 구동형식을 선정하기 위하여 디젤발전기와 가스터빈의 민감도 분석을 하는 데 있다. 이를 위하여 디젤발전기와 가스터빈의 물리적 특성과 국내의 대체교류발전기 적용현황, 그리고 US-APWR의 비상발전기 및 대체교류발전기의 가스터빈 적용사례를 조사하였다. 마지막으로 신뢰도 데이터에 대한 민감도 분석과 신형 노형인 APR+에 가스터빈 대체교류발전기를 적용하여 노심손상빈도의 민감도를 분석하였다.