• Title/Summary/Keyword: Alloy composition

Search Result 747, Processing Time 0.026 seconds

Optimized Thermoelectric Properties in Zn-doped Zintl Phase Magnesium-Antimonide

  • Rahman, Md. Mahmudur;Ur, Soon-Chul
    • Korean Journal of Materials Research
    • /
    • v.32 no.6
    • /
    • pp.287-292
    • /
    • 2022
  • Magnesium-antimonide is a well-known zintl phase thermoelectric material with low band gap energy, earth-abundance and characteristic electron-crystal phonon-glass properties. The nominal composition Mg3.8-xZnxSb2 (0.00 ≤ x ≤ 0.02) was synthesized by controlled melting and subsequent vacuum hot pressing method. To investigate phase development and surface morphology during the process, X-ray diffraction (XRD) and scanning electron microscopy (SEM) were carried out. It should be noted that an additional 16 at. % Mg must be added to the system to compensate for Mg loss during the melting process. This study evaluated the thermoelectric properties of the material in terms of Seebeck coefficient, electrical conductivity and thermal conductivity from the low to high temperature regime. The results demonstrated that substituting Zn at Mg sites increased electrical conductivity without significantly affecting the Seebeck coefficient. The maximal dimensionless figure of merit achieved was 0.30 for x = 0.01 at 855 K which is 30% greater than the intrinsic value. Electronic flow properties were also evaluated and discussed to explain the carrier transport mechanism involved in the thermoelectric properties of this alloy system.

MICROSTRUCTURAL STUDY OF $Fe_{1-x}Ti_x$ ALLOYS FORMED BY ION BEAM MIXING

  • Jeon, Y.;Lee, Y.S.;Choi, B.S.;Woo, J.J.;Whang, C.N.
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.127-132
    • /
    • 1997
  • Microstructure of the Fe-Ti system by ion beam mixing of multilayers at 300 K and 77 K has been studied in a wide composition range. The ion bombardment was carried out using $Ar^+$ ions at 80 keV. Using grazing angle x-ray diffraction we find that the lattice parameters of these bcc solid solutions are very close to that of $\alpha$-Fe. Extended x-ray absorption fine-structure spectroscopy have been performed to investgate the short-range order in the ion-beam-mixed state. The structure parameters, such as the interatomic distance and the coordination number are estmated from the Fe K-edge Fourier filtered EXAFS spectra. The interatomic distance is independent of the alloy concentration and it is almost constant. The study of x-ray absorption near-edge structure gives information on the individual $\rho$components of the partial densityof states of the conduction band of the Fe and Ti We also find that a charge transfer from Ti to Fe atoms takes place.

  • PDF

Microstructural Evolution and Mechanical Properties of Ti-6Al-4V Alloy through Selective Laser Melting: Comprehensive Study on the Effect of Hot Isostatic Pressing (HIP)

  • Gargi Roy;Raj Narayan Hajra;Woo Hyeok Kim;Jongwon Lee;Sangwoo Kim;Jeoung Han Kim
    • Journal of Powder Materials
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • This study explores the profound impact of varying oxygen content on microstructural and mechanical properties in specimens HO and LO. The higher oxygen concentration in specimen HO is found to significantly influence alpha lath sizes, resulting in a size of 0.5-1 ㎛, contrasting with the 1-1.5 ㎛ size observed in specimen LO. Pore fraction, governed by oxygen concentration, is high in specimen HO, registering a value of 0.11%, whereas specimen LO exhibits a lower pore fraction (0.02%). Varied pore types in each specimen further underscore the role of oxygen concentration in shaping microstructural morphology. Despite these microstructural variations, the average hardness remains consistent at ~370 HV. This study emphasizes the pivotal role of oxygen content in influencing microstructural features, contributing to a comprehensive understanding of the intricate interplay between elemental composition and material properties.

Nano-engineering of Hybrid Titanium Oxide Structure (TiO2) using Pore-widening Concentration for Enhanced Superhydrophilicity

  • Yeji Choi;Chanyoung Jeong
    • Corrosion Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.41-53
    • /
    • 2024
  • Titanium alloy is gaining attention in the medical industry due to its excellent biocompatibility and osteoconductivity. However, the natural oxide film on the titanium surface is insoluble, resulting in inadequate bone adhesion. Therefore, it is necessary to optimize the contact between biological tissues and implant surfaces, and alter the chemical composition and morphological characteristics of the implant surface. In this study, the anodization method was applied to titanium surface treatment to form a uniform and robust oxide film. Subsequently, a chemical process, pore-widening, was employed to change the morphological characteristics of the oxide film. The concentration of the pore-widening solution was varied at 2, 4, 6, and 8 wt% and the process time was set at 30 and 60 minutes. As the concentration of the pore-widening solution increased the pore diameter of the oxide film increased. Notably, at 6 wt% for 60 minutes, the oxide film exhibited a coexistence of pillars and pores. Based on this, it was determined that surface roughness increased with higher concentration and longer process time. Additionally, the presence of pillars and pores structures maximized hydrophilicity. This study provides insights into enhancing the surface properties of titanium for improved performance in medical implants.

Preparation of TiCoxFe1-x(x=0.50~1.00) System Metal Membrane for Hydrogen Separation (수소분리용 TiCoxFe1-x(x=0.50~1.00)계 금속막 제조)

  • Jang, Kyu-young;Kang, Tae Beom
    • Membrane Journal
    • /
    • v.25 no.2
    • /
    • pp.191-201
    • /
    • 2015
  • We have studied on the preparation of $TiCo_xFe_{1-x}$(x=0.50~1.00) system alloy, the characteristics of $TiCo_xFe_{1-x}$(x=0.50~1.00) system alloy by X-ray diffractometer (XRD), pressure composition temperature (PCT) curve, scanning electron microscopy (SEM) and the $H_2-N_2$ gas mixture separation of $TiCo_xFe_{1-x}$(x=0.50~1.00)- stainless steel (SS) composite membranes. The formation of $TiCo_xFe_{1-x}$(x=0.50~1.00) system alloys with cubic crystal same as TiCo was confirmed by X-ray diffractometer. $TiCo_xFe_{1-x}$(x=0.50~1.00) system alloys showed the hysteresis at $120^{\circ}C$. As the Fe content of $TiCo_xFe_{1-x}$(x=0.50~1.00) system alloys increased, the hysteresis was increased both range x=0.90~1.00 and x=0.55~0.60, and the range x=0.55~0.90 gave decreased hysteresis. $TiCo_{0.55}Fe_{0.45}$ alloy was the one showed the lowest hysteresis among them. The lowest value of hydrogen permeation pressure of $TiCo_xFe_{1-x}$(x=0.50~1.00)-SS composite membrane was $TiCo_{0.55}Fe_{0.45}$-SS composite membrane with the value of 2.5 atm at $120^{\circ}C$; otherwise, $TiCo_{0.90}Fe_{0.10}$-SS composite had the highest pressure value among the membranes with the value of 10 atm. $TiCo_{0.55}Fe_{0.45}$-SS composite membrane was the best to separate the $H_2-N_2$ gas mixture excellently among the $TiCo_xFe_{1-x}$(x=0.50~1.00)-SS composite membranes since $TiCo_{0.55}Fe_{0.45}$ had the least hysteresis, and hydrogen permeation pressure was the lowest with value of 2.5 atm.

Morphology of RF-sputtered Mn-Coatings for Ti-29Nb-xHf Alloys after Micro-Pore Form by PEO

  • Park, Min-Gyu;Park, Seon-Yeong;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.197-197
    • /
    • 2016
  • Commercially pure titanium (CP Ti) and Ti-6Al-4V alloys have been widely used for biomedical applications. However, the use of the Ti-6Al-4V alloy in biomaterial is then a subject of controversy because aluminum ions and vanadium oxide have potential detrimental influence on the human body due to vanadium and aluminum. Hence, recent works showed that the synthesis of new Ti-based alloys for implant application involves more biocompatible metallic alloying element, such as, Nb, Hf, Zr and Mo. In particular, Nb and Hf are one of the most effective Ti ${\beta}-stabilizer$ and reducing the elastic modulus. Plasma electrolyte oxidation (PEO) is known as excellent method in the biocompatibility of biomaterial due to quickly coating time and controlled coating condition. The anodized oxide layer and diameter modulation of Ti alloys can be obtained function of improvement of cell adhesion. Manganese(Mn) plays very important roles in essential for normal growth and metabolism of skeletal tissue in vertebrates and can be detected as minor constituents in teeth and bone. Radio frequency(RF) magnetron sputtering in the various PVD methods has high deposition rates, high-purity films, extremely high adhesion of films, and excellent uniform layers for depositing a wide range of materials, including metals, alloys and ceramics like a hydroxyapatite. The aim of this study is to research the Mn coatings on the micro-pore formed Ti-29Nb-xHf alloys by RF-magnetron sputtering for dental applications. Ti-29Nb-xHf (x= 0, 3, 7 and 15wt%, mass fraction) alloys were prepared Ti-29Nb-xHf alloys of containing Hf up from 0 wt% to 15 wt% were melted by using a vacuum furnace. Ti-29Nb-xHf alloys were homogenized for 2 hr at $1050^{\circ}C$. Each alloy was anodized in solution containing typically 0.15 M calcium acetate monohydrate + 0.02 M calcium glycerophosphate at room temperature. A direct current power source was used for the process of anodization. Anodized alloys was prepared using 270V~300V anodization voltage at room. Mn coatings was produced by RF-magnetron sputtering system. RF power of 100W was applied to the target for 1h at room temperature. The microstructure, phase and composition of Mn coated oxide surface of Ti-29Nb-xHf alloys were examined by FE-SEM, EDS, and XRD.

  • PDF

Effect of HA Crystals Precipitated by Hydrothermal-Treatment on the Bioactivity of Ti-6Al-7Nb Alloy (열수처리에 의해 석출된 HA 결정이 Ti-6Al-7Nb 합금의 생체활성에 미치는 영향)

  • Kwon O. S.;Choi S. K.;Moon J. W.;Lee M. H.;Bae T. S.;Lee O. Y.
    • Korean Journal of Materials Research
    • /
    • v.14 no.9
    • /
    • pp.607-613
    • /
    • 2004
  • This study was to investigate the surface properties of electrochemically oxidized Ti-6Al-7Nb alloy by anodic spark discharge technique. Anodizing was performed at current density 30 $mA/cm^2$ up to 300 V in electrolyte solutions containing $DL-{\alpha}$-glycerophosphate disodium salt hydrate($DL-{\alpha}$-GP) and calcium acetate (CA). Hydrothermal treatment was done at $300^{\circ}C$ for 2 hrs to produce a thin outermost layer of hydroxyapatite (HA). The bioactivity was evaluated from HA formation on the surfaces in a Hanks' solution with pH 7.4 at $36.5^{\circ}C$ for 30 days. The size of micropores and the thickness of oxide film increased and complicated multilayer by increasing the spark forming voltage. Needle-like HA crystals were observed on anodic oxide film after the hydrothermal treatment at $300^{\circ}C$ for 2 hrs. When increasing $DL-{\alpha}$-GP in electrolyte composition, the precipitated HA crystals showed the shape of thick and shorter rod. However, when increasing CA, the more fine needle shape HA crystals were appeared. The bioactivity in Hanks' solution was accelerated when the oxide films composed with strong anatase peak with presence of rutile peak. The increase of amount of Ca and P was observed in groups having bioactivity in Hanks' solution. The Ca/P ratio of the precipitated HA layer was equivalent to that of HA crystal and it was closer to 1.67 as increasing the immersion time in Hanks' solution.

Relationship Between Microstructure and Electrical Resistivity of Sb-InSb-and Sn-Bi Eutectic Alloys (Sb-InSb및 Sn-Bi공정합금의 미세조직과 전기비저항)

  • Seok, Myeong-Jin;Choe, Gil-Hyeon;Lee, Dong-Cheol;Mun, In-Hyeong
    • Korean Journal of Materials Research
    • /
    • v.4 no.1
    • /
    • pp.97-106
    • /
    • 1994
  • The dependence of the electrical resistivity on the eutectic composition and growth rates was investigated in the unidirectionally solidified Sb-InSb and Sn-Bi eutectic alloy systems, which were generally classified into the groups of f-f and nf-f eutectic system. Sb-InSb alloys containing 26-34wt.% In and Sn-Bi alloys containing 53-65wt.%Bi were prepared in vacuum sealed in a silica tube, and then these were unidirectionally solidified. Electrical resistivity of the specimens prepared by cutting the crystal section in parallel with the transverse direction and by cutting in longitudinal direction was measured. As the growth rate increased, the Sb-InSb and Sn-Bi eutectic alloys showed that the resistivity of longitudinal to the growth direction was increased but that of transverse to the growth direction was decreased. In the case of Sb-InSb eutectic alloy, increas~ng the phase boundary area and decreasing the fiber directionallity caused to increase the $p \; \parallel$ , while increasing the phase boundary area increased the $p \; \\perp$ As expected, the eutectic microstructure could be analysed well in terms of electrical resistivity.

  • PDF

Evaluation of Bioactivity of Titanium Implant Treated with H2O2/HCl Solution (H2O2/HCl 처리한 Ti 임플란트의 생체활성 평가)

  • Yue J. S.;Kwon O. S.;Lee O. Y.;Lee M. H.;Song K. H.
    • Korean Journal of Materials Research
    • /
    • v.15 no.5
    • /
    • pp.353-360
    • /
    • 2005
  • Surface treatment play an important role in nucleating calcium phosphate deposition on surgical Ti implant. Therefore, the purpose of this study is to examine whether the precipitation of apatite on cp-Ti and Ti alloys are affected by surface modification in HCl and $H_2O_2$ solution. Specimens were then chemically treated with a solution containing 0.1 M HCl and 8.8M $H_2O_2$ at $80^{\circ}C$ for 30 mins, and subsequently heat-treated at $400^{\circ}C$ for 1 hour. All specimens were immersed in the HBSS with pH 7.4 at $36.5^{\circ}C$ for 15 days, and the surface was examined with XRD, SEM, EDX ana XPS. Also, pure Ti, Ti-6Al-4V and Ti-6Al-7Nb alloy specimens with and without surface treatment were implanted in the abdominal connective tissue of mice for 4 weeks. All specimens chemically treated with HCl and $H_2O_2$ solution have the ability to form a apatite layer in the HBSS which has inorganic ion composition similar to human blood plasma. The average thickness of the fibrous capsule surrounding the specimens implanted in the connective tissue was $38.57\;{\mu}m,\;62.27\;{\mu}m\;and\;45.64\;{\mu}m$ in the cp-Ti, Ti-6Al-4V ana Ti-6Al-7Nb alloy specimens with the chemical treatment respectively, and $52.20\;{\mu}m,\;75.62\;{\mu}m\;and\;66.56\;{\mu}m$ in the commercial specimens of cp-Ti, Ti-6Al-4V and Ti-6Al-7Nb without any treatment respectively. The results of this evaluation indicate that the chemically treated cp-Ti, Ti-6Al-4V ana Ti-6Al-7Nb alloys have better bioactivity and biocompatibility compared to the other metals tested.

Direct Determination of Molybdenum in Simulated Nuclear Spent Fuels by Inductively Coupled Plasma Atomic Emission Spectrometry (유도결합플라스마 원자방출분광법을 이용한 모의 사용후핵연료 중 몰리브덴 분석)

  • Choi, Kwang Soon;Lee, Chang Heon;Park, Soon Dal;Park, Yang Soon;Joe, Kih Soo
    • Analytical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.291-296
    • /
    • 2000
  • The SIMFUEL which composition is similar to PWR nuclear spent fuels was dissolved with a acid digestion bomb. An analytical conditions of ICP-AES for the direct determination of molybdenum in the uranium matrices without separation process were investigated. Based on the effect of uranium on molybdenum intensity. the most optimum wavelengths of molybdenum were found to be 202.030 and 203.844 nm. However, the method of standard additions is applied to overcome the effects of changing background caused by analyzing the sample solutions containing high concentration of uranium and the standard calibration solutions. The relative error of two methods, direct and indirect measurements with cation exchange resin separation procedures, was less than 5%. Therefore it was possible for this procedure to directly measure molybdenum in uranium matrices without separation. And this method was also applied to the determination of several percent of molybdenum in a U-Mo alloy.

  • PDF