• 제목/요약/키워드: All-ceramic restoration

검색결과 101건 처리시간 0.024초

지르코니아 코아가 전부도재관의 색조에 미치는 영향에 대한 분광측색분석 (SPECTROPHOTOMETRIC ANALYSIS OF THE INFLUENCE OF ZIRCONIA CORE ON THE COLOR OF CERAMIC)

  • 배아란;백진;우이형;김형섭;최대균
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.466-477
    • /
    • 2005
  • Statement of problem : Problem of matching the appearance of porcelain restorations with the patient's natural dentition has always been a concern to dental clinicians. Recently, demands for esthetics, even in restorations requiring strength, has brought a revolution to dentistry and increased use of zirconia. Among the various factors, shade and translucency or the core can significantly affect the overall esthetics of the restoration and should be considered when selecting an all-ceramic system. Purpose : The purpose of this study was to spectrophotometrically evaluate the influence of different zirconia systems and core thickness on the final shade of all-ceramic restorations using the CIEL$^*a^*b^*$ system. Material and Methods: Core specimens (n : 20 per group) of In-Ceram Alumina, In-Ceram Zirconia, Digident CAD/CAM Zirconia, Cercon Zirconia were fabricated 20mm in diameter. 10 specimens of each group were fabricated at core thickness of 0.5mm and 0.7mm. These core specimens were veneered with shade Al & A3 porcelain of the recommended manufacturer. CIEL$^*a^*b^*$ coordinates were recorded for each specimen with a spectrophotometer (Model CM-2600d, Minolta, Japan). Color differences were calculated using the equation ${\Delta}E^*=[({\Delta}L^*)^2+({\Delta}a^*)^2+({\Delta}b^*)^2]^{\frac{1}{2}}$. Results : 1. Specimens of core thickness 0.5mm and 0.7mm did not exhibit clinically perceived color difference. 2. Regarding shade reproducibility, In-Ceram Alumina and In-Ceram Zirconia showed significant difference within each group. 3. Cercon Zirconia group showed the highest $L^*$ value and Digident Zirconia group showed lowest $a^*$ & $b^*$ value. 4. Generally the shade difference between materials was higher in the A3 shade group than in the Al shade group. Conclusion: Within the limitations of this study, there was no color difference after increase in core thickness and every all-ceramic system has color characteristics that clinicians have to consider when selecting materials. Also, manufacturers of different porcelain systems must make every effort to achieve color reproducibility.

Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations

  • Hasanzade, Mahya;Koulivand, Soudabeh;Moslemian, Naeime;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권3호
    • /
    • pp.173-180
    • /
    • 2020
  • PURPOSE. This study compared digital (reference point matching) and replica methods for measuring marginal and internal fit of full coverage restorations. MATERIALS AND METHODS. A maxillary left first molar typodent was fixed on to an aluminum base and prepared to receive all-ceramic full coverage restoration. The model was scanned with an intraoral scanner (CEREC Omnicam, Sirona, York, PA, USA). Twelve crowns were fabricated from lithium disilicate blocks (IPS emax CAD, Ivoclar Vivadent) and then crystalized. Marginal and internal fit of each restoration was measured by two examiners using replica and a new digital three-dimensional technique. Reliability between the two methods and two examiners was assessed by correlation and Cronbach's Alpha coefficient (P<.05). A Bland-Altman assessment for agreement was used to compare the two methods. RESULTS. Bland-Altman assessment showed that the mean of difference for marginal, absolute marginal, and axial gap was respectively -1.04 ㎛, -41.9 ㎛, and -29.53 ㎛ with limit of agreement (LOA) between -37.26 to 35.18 ㎛ for marginal, -105.85 to 22.05 ㎛ for absolute marginal and -80.52 to 22.02 ㎛ for axial gap. Positive correlation for repeatability (P<.05) in determining marginal and internal gaps by the two examiners in both techniques was revealed. Reliability of both techniques in all sites of measurements was at least good (0.8 ≤ α < 0.9). CONCLUSION. Both measuring techniques appeared highly reliable for evaluating fit of fixed dental restorations, while reference point matching provided higher values in axial and absolute marginal gap assessment.

두 종류의 CAD/CAM 지르코니아 전부도재관의 도재 축성 전후의 변연적합도 비교 (Comparison of marginal fit before and after porcelain build-up of two kinds of CAD/CAM zirconia all-ceramic restorations)

  • 신호식;김석규
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.528-534
    • /
    • 2008
  • 연구목적: 변연적합도는 보철수복물의 성공을 좌우하는 중요한 요소 중의 하나이다. McLean과 von Fraunhofer등에 의하면 120 ${\mu}m$ 이하를 임상적으로 허용할 수 있다고 했는데, 이를 넘는 정확하지 않은 변연은 지각과민을 일으키거나 이차 우식을 일으키고, 치태 축적을 용이하게 하여 보철물의 수명을 단축시키게 된다. 이에 최근에 우리나라에 소개되어 임상적으로 사용되고 있는 CAD-CAM 전부도재 수복물 중 $LAVA^{(R)}$ 시스템 (3M ESPE, St. Paul, MN)과 $EVEREST^{(R)}$ 시스템 (KaVo Dental GmbH, Biberach, Germany)으로 제작한 지르코니아 전부 도재관들이 도재전장 금속주조 수복물과 비교해 보아 코핑 상태일 때와 도재축성 후 각각 변연적합도의 차이가 있는지를 살펴보고자 하였다. 재료와 방법: 상악 제1소구치 덴티폼 치아를 high speed diamond bur 로 교합면 2.0 mm, 순설면 1.0 mm, 그리고 변연은 chamfer margin을 6도 측면 경사 절삭 기계로 균일하게 제작해서 이를 인상 채득하여 금속 지대치를 제작하였다. 이를 덴티폼 모형상에 장착한 후 전악인상을 채득하여 $LAVA^{(R)}$ 수복물 코핑, $EVEREST^{(R)}$ 수복물 코핑, 그리고 도재전장 금속주조 수복물 코핑을 각각 8개씩 제작하였다. 이들 코핑을 염색제를 섞은 Fit-checker $II^{(R)}$ (GC Cor., Tokyo, Japan)를 이용하여 금속 지대치에 접합시킨 뒤, $Microhiscope^{(R)}$ system (HIROX KH-1000 ING Plus, Seoul, Korea)을 이용하여 300배율로 관찰하면서 변연 간격을 ${\mu}m$단위로 측정하였다. 도재축성 후에도 마찬가지 방법으로 모든 수복물의 변연간격을 측정하여 통계 처리를 하였다. 결과: 코핑 상태에서의 평균 변연간격 값은 $EVEREST^{(R)}$ 에서 $52.00{\pm}11.94\;{\mu}m$, $LAVA^{(R)}$$ 56.97{\pm}10.00\;{\mu}m$, 그리고 도재 전장 금속 주조 수복물은 $97.38{\pm}18.54\;{\mu}m$를 보였고, 도재축성 후에 평균 변연 간격값은 $EVEREST^{(R)}$$61.69{\pm}19.33\;{\mu}m$, $LAVA^{(R)}$$70.81{\pm}12.99\;{\mu}m$, 그리고 도재 전장 금속 주조 수복물은 $115.25{\pm}23.86\;{\mu}m$를 보였다. 결론: 1. $LAVA^{(R)}$$EVEREST^{(R)}$ 수복물은 도재 전장 금속 주조 수복물과 비교하여 각각 코핑상태일 때와 도재 축성 후 모두 유의성 있는 (P < .05) 차이를 보이는 우수한 변연 적합도를 나타내었다. 2. $LAVA^{(R)}$$EVEREST^{(R)}$ 수복물 간의 평균 변연 간격 비교에서 코핑 상태일 때와 도재 축성 후에 모두 유의성 있는 차이는 없었다 (P > .05). 3. $LAVA^{(R)}$$EVEREST^{(R)}$ 그리고 PFM 은 각각 코어 상태일 때와 비교하여 도재 축성 후 변연 간격에서 약간 증가되었으나 유의성 있는 차이를 보이지는 않았다 (P > .05).

In vitro evaluation of fracture strength of zirconia restoration veneered with various ceramic materials

  • Choi, Yu-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권3호
    • /
    • pp.162-169
    • /
    • 2012
  • PURPOSE. Fracture of the veneering material of zirconia restorations frequently occurs in clinical situations. The purpose of this in vitro study was to compare the fracture strengths of zirconia crowns veneered with various ceramic materials by various techniques. MATERIALS AND METHODS. A 1.2 mm, $360^{\circ}$ chamfer preparation and occlusal reduction of 2 mm were performed on a first mandibular molar, and 45 model dies were fabricated in a titanium alloy by CAD/CAM system. Forty-five zirconia copings were fabricated and divided into three groups. In the first group (LT) zirconia copings were veneered with feldspathic porcelain by the layering technique. In the second group (HT) the glass ceramic was heat-pressed on the zirconia coping, and for the third group (ST) a CAD/CAM-fabricated high-strength anatomically shaped veneering cap was sintered onto the zirconia coping. All crowns were cemented onto their titanium dies with Rely $X^{TM}$ Unicem (3M ESPE) and loaded with a universal testing machine (Instron 5583) until failure. The mean fracture values were compared by an one-way ANOVA and a multiple comparison post-hoc test (${\alpha}$= 0.05). Scanning electron microscope was used to investigate the fractured interface. RESULTS. Mean fracture load and standard deviation was $4263.8{\pm}1110.8$ N for Group LT, $5070.8{\pm}1016.4$ for Group HT and $6242.0{\pm}1759.5$ N for Group ST. The values of Group ST were significantly higher than those of the other groups. CONCLUSION. Zirconia crowns veneered with CAD/CAM generated glass ceramics by the sintering technique are superior to those veneered with feldspathic porcelain by the layering technique or veneered with glass ceramics by the heat-pressing technique in terms of fracture strength.

출력 지지대 두께가 선택적 레이저 용융법으로 제작된 금속 하부구 조물 적합도에 미치는 영향 (Effect of support thickness on the adaptation of Co-Cr alloy copings fabricated using selective laser melting)

  • 김재홍;김세연
    • 대한치과기공학회지
    • /
    • 제45권3호
    • /
    • pp.67-73
    • /
    • 2023
  • Purpose: This in vitro study aimed to evaluate the clinical acceptability of precision of fit of the support thickness of Co-Cr alloy copings fabricated using selective laser melting (SLM). Methods: Thirty dental stone models of maxillary left molar abutments were manufactured, images were taken using a scanner, and a computer-aided design program was used to design the form of a conventional metal ceramic crown coping. Overall, 30 single copings were made from Co-Cr alloy using SLM and divided into three support radius groups (0.1, 0.25, and 0.35 mm) of 10 for each. Digitized data were superimposed with three-dimensional inspection software to quantitatively obtain the machinability of a ceramic crown coping, and visual differences were confirmed using a color map. The root mean square values of the ceramic crown coping group were statistically analyzed using one-way analysis of variance (α=0.05). Results: The precision of fit was superior with 0.25 mm compared with 0.1 mm and 0.35 mm, and the results exhibited significant differences (p<0.05). All specimens showed that various support thicknesses did not exceed the clinically permitted value of 120 ㎛, which mean that more than 0.1 mm and 0.35 mm of support radius for SLM was adequate. Conclusion: The support thickness of Co-Cr alloy restoration fabricated using SLM is shown to affect the adaptation.

CAD/CAM을 이용하여 제작한 All-ceramic core의 변연 적합도 (ON THE MARGINAL FIDELITY OF ALL-CERAMIC CORE USING CAD/CAM SYSTEM)

  • 김동근;조인호;임주환;임헌승
    • 대한치과보철학회지
    • /
    • 제41권1호
    • /
    • pp.20-34
    • /
    • 2003
  • Novel methods producing supplementary and prosthetic material by cutting or discharge processing via computer design have been proposed as alternatives for traditional casting methods and are being utilized for commercial purposes. The CAD/CAM system used in dentistry can be classified into three-dimensional input of target values, restoration design, and material processing. The marginal fidelity in production of In-Ceram core has important clinical implications and is a key consideration issue in CAD/CAM production as well. Through this research, the author arrived at the following conclusion aaer conducting comparison analysis of marginal fidelities between the In-Ceram core produced via CAD/CAM and that produced through the traditional method ; 1. In the cases of mesial, distal, and lingual margins, the core margins via CAD/CAM produced lower values than those via the traditional method, but the differences were found to be statistically insignificant. 2. In the case of labial flange, the core margins via CAD/CAM produced lower values than those via the traditional method and the differences were found to be statistically significant. (p<0.05) 3. In comparision with overall marginal fidelity, the core margins via CAD/CAM produced lower values than those via the traditional method, but the differences were found to be statistically insignificant. 4. Among the core margins produced via the traditional method did not have statistically significant differences but fir those produced via CAD/CAM had statistically significant differences between labial and lingual sides and between labial and mesial sides. (p <0.05).

전부도재관의 변연형태에 따른 변연적합도에 관한 연구 (MARGINAL FIDELITY ACCORDING TO THE MARGIN TYPES OF ALL CERAMIC CROWNS)

  • 구재용;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제35권3호
    • /
    • pp.445-457
    • /
    • 1997
  • Poor marginal fidelity resulting in a large marginal gap increases plaque accumulation, gingival inflammation and dental caries. The purpose of this study was to evaluate the marginal fit of three different cervical finishing methods of prepared teeth. A stereomicroscope was used to measure the space between the margin of restoration and the finishing line of prepared tooth. The results were statistically analyzed using the ANOVA and Multiple Range Test(Tukey's HSD). The results were as follows : 1. There were no significant differences concerning the types of tooth and positon (P>0.05), whereas the differences were statistically significant in case of cervical finishing methods (P<0.05). 2. There were statistically significant differences between before and after cementation (P<0.05). 3. In comparison according to variable margins after cementation, the gap discrepancies were increased in $130^{\circ}$ shoulder margin, chamfer margin and $90^{\circ}$ shoulder margin in ascending order, and there were significant differences between $90^{\circ}$ shoulder margin and chamfer, $130^{\circ}$ shoulder margin 4. In comparison according to variable margins, the gap discrepancies were increased in chamfer margin, $130^{\circ}$ shoulder margin and $90^{\circ}$ shoulder margin in ascending order, and there were significant differences between $90^{\circ}$ shoulder margin and chamfer, $130^{\circ}$ shoulder margin. 5. This study demonstrated a better marginal fit with all-ceramic crowns fabricated on chamfer and $130^{\circ}$ shoulder margin compared with $90^{\circ}$ shoulder margin.

  • PDF

Evaluation of the color reproducibility of all-ceramic restorations fabricated by the digital veneering method

  • Kim, Jae-Hong;Kim, Ki-Baek;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권2호
    • /
    • pp.71-78
    • /
    • 2014
  • PURPOSE. The objective of this study was to evaluate the clinical acceptability of all-ceramic crowns fabricated by the digital veneering method vis-$\grave{a}$-vis the traditional method. MATERIALS AND METHODS. Zirconia specimens manufactures by two different manufacturing method, conventional vs digital veneering, with three different thickness (0.3 mm, 0.5 mm, 0.7 mm) were prepared for analysis. Color measurement was performed using a spectrophotometer for the prepared specimens. The differences in shade in relation to the build-up method were calculated by quantifying ${\Delta}E^*$ (mean color difference), with the use of color difference equations representing the distance from the measured values $L^*$, $a^*$, and $b^*$, to the three-dimensional space of two colors. Two-way analysis of variance (ANOVA) combined with a Tukey multiple-range test was used to analyze the data (${\alpha}$=0.05). RESULTS. In comparing means and standard deviations of $L^*$, $a^*$*, and $b^*$ color values there was no significant difference by the manufacturing method and zirconia core thickness according to a two-way ANOVA. The color differences between two manufacturing methods were in a clinically acceptable range less than or equal to 3.7 in all the specimens. CONCLUSION. Based on the results of this study, a carefully consideration is necessary while selecting upper porcelain materials, even if it is performed on a small scale. However, because the color reproducibility of the digital veneering system was within the clinically acceptable range when comparing with conventional layering system, it was possible to estimate the possibility of successful aesthetic prostheses in the latest technology.

ShadeEye$^{(R)}$ NCC system을 이용한 Vita CAD/CAM Ceramic Block의 크기에 따른 색조 일치성 비교연구 (Comparative Study of Color Correspondence According to Size of Vita CAD/CAM Ceramic Block Using ShadeEye-Ncc$^{(R)}$ System)

  • 김재홍;김혜영;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제33권3호
    • /
    • pp.203-210
    • /
    • 2011
  • Purpose: The purpose of this study was to compare color correspondence of different sizes of Vita Mark II$^{(R)}$ and TriLuxe$^{(R)}$ Feldspar blocks. Methods: The three commercially available shades(1M2, 2M2, 3M2) of Mark II & TriLuxe blocks for the CEREC$^{(R)}$ CAD/CAM system were examined. For each of three colors, three different sizes were tested, 5 blocks each. The measurements were made using a spectrophotometer equipped with an integrating sphere using the CIE $L^*$, $a^*$, $b^*$ colorimetric system. Results: The $L^*$, $a^*$, $b^*$ value of Vita Mark II$^{(R)}$ ceramic block showed significantly higher than TriLuxe$^{(R)}$ ceramic block(p<0.05). In comparing the Vita Mark II$^{(R)}$ specimen of the three different shade, color differences between materials(${\Delta}E^*$) showed the lowest value of 2.09, and the highest was 2.24. ${\Delta}E^*$ values of the materials of Vita Mark II$^{(R)}$ were higher than 2. As the size of ceramic block differed, the color correspondence of Vita Mark II$^{(R)}$ showed statistically significant difference but, this result is clinically acceptable. Conclusion: All the different sizes of the different shades of Vita TriLuxe$^{(R)}$ blocks for the CEREC$^{(R)}$ system showed the high degree of color correspondence necessary in industrially prefabricated CAD/CAM blocks. The results of the present study suggested that it would be necessary to establish the reproducible and constant color specification system for an esthetic restoration.

$Procera^{(R)}$ AllCeram 을 이용한 도재관의 임상적 변연적합도에 관한 연구 (The marginal fidelity of $Procera^{(R)}$ AllCeram alumina copings and crowns of patients)

  • 송영균;조인호;이종혁
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.470-478
    • /
    • 2008
  • 완전도재 수복물은 뛰어난 심미성을 가지고 있어, 환자들의 심미적 욕구를 충족시킬 수 있다. 이러한 도재관을 제작함에 있어 CAD/CAM 시스템을 이용하는 것은 시간과 비용을 절약할 수 있는 장점을 가지고 있으며, 정밀도 또한 점차 높아지고 있다. 특히 변연적합도는 수복물의 성공 여부에 중요한 요소이고, 이 분야에 대한 실험적 연구는 많이 보고되고 있으나 임상적인 연구는 아직 미흡한 실정이다. 본 연구에서는 CAD/CAM 시스템의 하나인 $Procera^{(R)}$ AllCeram 시스템의 변연적합도를 실제 환자의 수복물 상에서 측정함으로써 임상에 사용되는 CAD/CAM 시스템의 변연적합도를 연구하고자 하였다. 단국대학교 치과병원 보철과에 내원한 56명, 101개의 지대치에 대해 코핑 상태와 최종수복물의 변연오차를 입체광학현미경으로 측정하고 비교분석하여 다음과 같은 결과를 얻었다. 실험 결과, 코핑의 변연오차 ($53.84{\pm}38.83\;{\mu}m$)보다 최종 수복물에서의 변연오차 ($45.82{\pm}30.84\;{\mu}m$)가 더 낮은 값을 나타났으며, 이는 통계적으로 유의한 차이가 있었다 (P < .05). 각 측정 지점간 비교에서 역시 모든 변연에서 코핑 의 변연오차가 최종 수복물에서의 변연오차보다 더 높은 값을 나타냈으며, 통계적으로 유의한 차이가 있었다 (P < .05). 구치부의 변연오차는 전치부의 변연오차보다 더 높은 값을 나타냈으나, 통계적으로 유의한 차이는 없었다. 설측 변연의 경우, 근심, 원심, 순측 변연의 오차보다 더 높은 값을 나타냈으며, 통계적으로 유의한 차이가 있었다 (P < .05). 이상의 결과로 보아 $Procera^{(R)}$ 시스템의 Allceram 관의 변연적합도는 임상적 허용 범위 내에 있었으며, 특히 도재 축성후 변연적합도 는 더 우수해지는 것으로 나타났으며, 각 변연 중 설측 변연의 오차가 가장 큰 것은 주모형의 정보 입력시 순측 부위의 특성상 일어나는 오류로 사료된다. $Procera^{(R)}$ 시스템 Allceram 관 수복시 설측 변연에 더욱 주의를 기울이는 것이 좋은 변연적합을 얻는 데 도움이 될 것으로 사료되며, 앞으로 주모형 변연 부위의 변곡 정도에 따른 변연오차에 대한 연구가 필요할 것으로 사료된다.