References
- Denissen HW, van der Zel JM, van Waas MAJ. Measurement of the margins of partial-coverage tooth preparation for CAD/CAlM. Int J Prosthodont 1999;12:395-400
- May KB, Russell MM, Razzoog ME, Lang BR. Precision of fit : The procera allceram crown. J Prosthet Dent 1998;80:394-404 https://doi.org/10.1016/S0022-3913(98)70002-2
- Mormann WH, Schug J. Grinding precision and accuracy of fit of CEREC2 CAD-CIM inlays. JADA 1997;128:47-53
- LaBarre EE, Belser UC, Meyer JM, Watanabe L. Computer-aided design and transverse strength of screw-retained attachment. Int J Prosthodont 1994;7:323-328
- Liu PR, Isenberg BP, Leinfelder KF. Evaluating CAD-CAM generated ceramic veneers. JADA 1993;124:59-63
- Andersson M, Carlsson L, Persson M, Bergman B. Accuracy of machine milling and spark erosion with a CAD/CAM system. J Prosthet Dent 1996;76:187-193 https://doi.org/10.1016/S0022-3913(96)90305-4
- Schmitt SM, Chance DA, Cronin RJ. Refining cast implant-retained restorations by electrical discharge machining. J Prosthet Dent 1995;73:280-283 https://doi.org/10.1016/S0022-3913(05)80206-9
- Evans DB. Correcting the fit of implant-retained restorations by electric discharge machining. J Prosthet Dent 1997;77:212-215 https://doi.org/10.1016/S0022-3913(97)70238-5
- Maeda Y, Minoura M, Tsutsumi S, Okada M, Nokubi T. A CAD/CAM System for Removable Denture. Part I: Fabrication of Complete Dentures. Int J Prosthodont 1994;7:17-21
- Rinke S, Huls A, Jahn L. Marginal Accuracy and Fracture Strength of Conventional and Copy-Milled All-Ceramic Crowns. Int J Prosthodont 1995;8:303-310
- Andersson M, Razzoog ME, Od n A, Hegenbarth EA, Lang BR. Procera : A new way to achieve an all-ceramic crown. Quintessence Int 1998;29:285-296
- Persson M, Andersson M, Bergman B.The accuracy of a high-precision digitizer for CAD/CAM of crowns. J Prosthet Dent 1995;74:223-229 https://doi.org/10.1016/S0022-3913(05)80127-1
- Kawata N, Ono H, Nishi Y, Hamano T, Nagaoka E. Trial of duplication procedure for complete denture by CAD/CAM. J Oral Rehabil 1997;24:540-548 https://doi.org/10.1046/j.1365-2842.1997.00522.x
- Sohmura T, Takahashi J. Use of CAD/CAM system to fabricate dental prostheses. part 1: CAD for a clinical crown restoration. Int J Prosthodont 1995;8:252-258
- Besimo C, Jeger C, Guggenheim R. Marginal adaptation of titanium frameworks produced by CAD/CAM techniques. Int J Prosthodont 1997;10:541-546
- Dastane A, Vaidyanathan TK. Vaidyanathan J, Mehra R, Hesby R. Development and evaluation of a new 3-D digitization and computer graphic system to study the anatomic tissue and restoration surface. J Oral Rehabil 1996;23:25-34 https://doi.org/10.1111/j.1365-2842.1996.tb00808.x
- Sturdevant JR, Bayne SC, Heymann HO. Margin gap size of ceramic inlays using second-generation CAD/CAM equipment. J Esthet Dent 1999;11:206-214 https://doi.org/10.1111/j.1708-8240.1999.tb00400.x
- Kim IS, Kim BO, Yoo KH, Kang DW. Design and fabrication of inner kcuus crown using three dimensional computer graphics. J Kor Academy of Pros. 2002;38:544-551
- Ha JK. Machining methods of CNC. II Jin Sa. 1997; p.74-75
- McLean JW. Von Fraunhofer JA. The estimation of cement film thickness by an invivo technique. Br Dent J Aug 3;1971;131:107-111
- Mclean JW. polycarboxylate cements. : Five years' experience in general practice. Br Dent J 1972;132:9-15 https://doi.org/10.1038/sj.bdj.4802795
- Van Roekel NB. Electrical Discharge machining in Dentistry. Int J Prosthodont 1992;5:114-121
- Chan DCN, Blackman R, Kaiser DA, Chung K. The effect of sprue design on the marginal accuracy of titanium castings. J Oral Rehabil 1998;25:424-429 https://doi.org/10.1046/j.1365-2842.1998.00268.x
- Jenkins CBG. Phillips RW. An evaluation of five inlay investing techniques employed with different types of wax patterns. J Prosthet Dent 1971;25:211-220 https://doi.org/10.1016/0022-3913(71)90110-7
- Mitchem JC, Wagner PC, Ferracane JL. Marginal adaptation of the Concept inlay system. Am J Dent 1994;7:232-234
- Small BW. Product review: All-ceramic system. General Dent 1998;446-448
- Felton DA, Kanoy BE, Bayne SC, Wirthman GP. Effect of in vivo crown margin discrepancies on periodontal health. J Prosthet Dent 1991;65:357-364 https://doi.org/10.1016/0022-3913(91)90225-L
- Willer J, Rossbach A, Weber HP. Computer assisted milling of dental restoration using a new CAD/CAM data acquisition system. J Prosthet Dent 1998;80:326-353
- The editorial committee of great dictionary of mechanical engineering. The great dictionary of mechanical engineering. Jib Moon Sa 1995;p.826-827
- Sorensen JA. A standardized method for determination of crown margin. J Prosthet Dent 1990;64:18-24 https://doi.org/10.1016/0022-3913(90)90147-5
- Kay GM, Jablonski DA, Dogon IL. Factors affecting the seating and fit of complete crowns : A computer simulation study. J Prosthet Dent 1986;55:13-18 https://doi.org/10.1016/0022-3913(86)90062-4
- Jorgensen KD. Factors affecting the film thickness of zinc phosphate cements. Acta Odontol Scan 1960;18:479-490 https://doi.org/10.3109/00016356009043879
- Cooper TM, Christensen GJ, Laswell HR, Baxter R. Effect of venting on cast gold full crowns. J Prosthet Dent 1971;26:621-626 https://doi.org/10.1016/0022-3913(71)90086-2
- Eames WB, O'Nell SJ, Montiero J, Miller G, Roan JD, Kohen KS. Technique to improve seating of casting. JADA 1978;96:432-437
- Fusayama T, Ide K, Hosoda H. Cement thickness between cast restoration walls. J Prosthet Dent 1963;13:354-364 https://doi.org/10.1016/0022-3913(63)90181-1
- Kydd WL, Nicholls JI, Harrington G, Freeman M. Marginal leakage of cast gold crowns luted with zinc phosphate cement: an in vivo study. J Prosthet Dent 1996;75:9-13 https://doi.org/10.1016/S0022-3913(96)90411-4
- Christensen GJ. Marginal fit of gold inlay asting. J Prosthet Dent 1966;16:297-305 https://doi.org/10.1016/0022-3913(66)90082-5
- Belser DC, Mecentee MI, Richter WA. Fit of three porcelain-fused-to-metal marginal designs in vivo : A scanning electron microscope study. J Prosthet Dent 1985;53:24-29 https://doi.org/10.1016/0022-3913(85)90058-7
- Byrne G, Goodacre CJ, Dykema RW, Moore BK. Comparative casting accuracy of high-palladium alloys. J Prosthet Dent 1986;55:297-301 https://doi.org/10.1016/0022-3913(86)90106-X
- West AJ, Goodacre CJ, Moore BK, Dykema RW. A comparison of four techniques for fabricating collarless metal ceramic crowns. J Prosthet Dent 1985;54:636-642 https://doi.org/10.1016/0022-3913(85)90238-0
- Pera P, Bassi F, Carossa S. In vitro margin aladaptation of alumina porcelain ceramic crown. J Prosthet Dent 1994;72:585-590 https://doi.org/10.1016/0022-3913(94)90289-5
- Rinke S, Margraf G, Jahn L, Huls A. Qualitatsbeurteilung von Kopiergefrasten Voll-Keramischen Kronengesusten(Celay/In-Ceram). Schweiz Monatsschr Zahnmed 1994;104:1495-1499
- Koo JY, Lim JH, Cho IH. Marginal fidelity according to the margin types of all ceramic crowns. J Kor Academy of Pros. 1997;35:445-457
- Tinschert J, Natt G, Mautsch W, Spiekermann H, Anusavice KJ. Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system. Oper Dent 2001;26(4):367-374
- Chen Y, Zhao Y, Wang H. Marginal fit of CAD/CAM ceramic inlays. Hua Xi Kou Qiang Yi Xue Za Zhi 1997;15:317-318
- Sulaiman F, Chai J, Jameson LM, Wozniak WT. A comparison of marginal fit of In-ceram, IPS Empress, and Procera Crowns. Int J Prosthodont 1997;10:478-484
- Denissen H, Dozi, A, van der Zel J, van Waas M. Marginal fit and short-term clinical performance of porcelain-veneered CICERO, CEREC, and Procera onlays. J Prosthet Dent 2000;84:506-513 https://doi.org/10.1067/mpr.2000.110258
- Valderrama S, Van Roekel N, Andersson M, Goodacre CJ, Munoz CA. A comparison of the marginal and internal adaptation of titanium and gold-platinum-palladium metal ceramic crowns. Int J Prosthodont 1995;8:29-37
- Palomo F, Peden J. Periodontal consideration of restorative procedure. J Prosthet Dent 1976;36:387-394 https://doi.org/10.1016/0022-3913(76)90159-1
- Bjorn AL, Bjorn H, Grkovic B. Marginal fit of restoration and its relation to periodontal bone level. Part I. Metal Fillings, Odontol Revy 1969;20:311-321
- Molin MK, Karlsson SL, Kristiansen MS. Influence of film thickness on joint bend strength of ceramic/resin composite joint. Dental Material 1996;12:245-249 https://doi.org/10.1016/S0109-5641(96)80030-3