• 제목/요약/키워드: Alignment method

검색결과 1,269건 처리시간 0.027초

정적 자세에서 하지정렬 측정방법에 관한 고찰 (Measurement Methods of Lower Extremity Alignment in Static Posture)

  • 공희경;조현래;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2003
  • We need to study about lower extremity alignment because the structure dictates the function of lower extremity. Through lower extremity alignment assessment in static posture, we recognize abnormal structural conditions which could affect dynamic motion such as gait. To evaluate of lower extremity alignment provide so many useful information, but method of measurement is so limited. Therefore, this review will assist understanding for measurement of lower extremity alignment in static posture. From now on study about the objective measurement method must be achieved much more in physical therapy.

  • PDF

상상연습을 병행한 발목 운동이 자세정렬에 미치는 영향 (Effects of Ankle Exercise combined with Mental Practice on Postural Alignment)

  • 양회송;강효정;허재원
    • 대한통합의학회지
    • /
    • 제6권2호
    • /
    • pp.99-106
    • /
    • 2018
  • Purpose : Various studies effects of mental practice. However, there is a lack of research on the effects of practice on postural alignment. Therefore this study to the effect of ankle exercise combined with mental practice on postural alignment of legs. Method : Subjects were randomly assigned to mental practice group (experimental group n=15) and general exercise group (control group n=15). Postural alignment was the hip, knee, and ankle joints. When viewed from the side, an arbitrary point in front of the malleolus makes a straight line with the plumb line. Exercise was performed a week for weeks. Exercise programs included muscle strengthening, relaxation, and proprioception exercise. The experimental group mental practice. Result : Both groups showed significant differences in postural alignment ankle joint, knee joint, and hip joint. In particular, the experimental group showed a larger change than the control group. However, significant difference in postural alignment change only the knee joint (p<0.05), and there was no significant difference the hip joint (experimental group=$0.77{\pm}0.81$, control group=$0.87{\pm}1.13$) and ankle joint (experimental group=$0.52{\pm}0.63$, control group=$0.48{\pm}0.41$). Conclusion : This study suggests that mental practice is effective as an exercise method postural alignment. Mental practice also expected to be musculoskeletal disorders. Therefore, additional studies should be conducted to verify the effect of mental practice on the alignment of various parts.

UV 배향된 액정셀에서의 전기광학 특성 (Electro-Optical Characteristics of the UV Aligned LCD Cell)

  • 이병순;이호영
    • 전기학회논문지P
    • /
    • 제62권4호
    • /
    • pp.223-226
    • /
    • 2013
  • In this study, we investigated the electro-optical(EO) characteristic of fringe-field switching(FFS) mode cell by the two kinds of ultraviolet(UV) alignment method on the organic thin film(polyimide: PI). The suitable organic layersfor FFS cell and the aligning capabilities of nematic liquid crystal(NLC) using the in-situ photoalignment method were studied Disclination is observed after conventional photoalignment method for 1h, and in-situ photoalignment method for 1h. Monodomain alignment of the NLC can be observed via in-situ photoalignment method for 2h and 3h. It is considered that NLC alignment is due to photo-depolymerization of the polymer with oblique non-polarized UV irradiation on PI surface. An unstable V-T curve of UV-aligned FFS-LCD with conventional photoalignment method can be achieved. However, a stable V-T curve of UV-aligned FFS-LCD with in-situ photoalignment method(1h), and V-T curve of UV-aligned FFS-LCD with in-situphotoalignment method was much stable comparing with that of other UV-aligned FFS-LCD's. As a result, more stable EO performanceof UV-aligned FFS-LCD with in-situphotoalignment method for 3h is obtained than that of the other UV-aligned FFS-LCD's.

이온빔 조사 각도와 에너지강도에 의한 수직 배향막의 특성 분석 (Characteristic Analysis of Vertical Alignment by Ion-beam Irradiation Angle and Energy Density)

  • 강동훈;오병윤;김병용;한진우;김영환;옥철호;한정민;이상극;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.398-398
    • /
    • 2007
  • The Liquid Crystal (LC) alignment uniformity is very important in LC devices. The alignment mechanism of LC molecules on a rubbed polyimide (PI) surface is very important for both LC fundamental research and application. So, Generally a rubbing method to align LC has been widely used to mass-produce LCD panels. But because rubbing method is contact method between rubbing fabric and indium-tin-oxide glass or flexible substrate, rubbing method has some defects, such as the electrode charges and the creation of contaminating particles. Thus we strongly recommend a non-contact alignment technique for getting rid of some defects of rubbing method. Most recently, the LC aligning capabilities achieved by ion-beam exposure on the organic and nonorganic thin film surface have been reported successfully. In this research, we studied the tilt angle generation and electro-optical performances for a NLC on homeotropic polyimide surfaces with ion-beam exposure. The LC aligning capabilities of a nematic liquid crystal (NLC) on a homeotropic PI surface using a new ion-beam method were studied. On the homeotropic PI surface, the tilt angle of the NLC by exposure ion-beam had a tendency to decrease as increased ion-beam energy density. And, on the homeotropic PI surface, the alignment character of the NLC with respect to ion-beam energy was good. And we achieved satisfactory result for EO character.

  • PDF

지역 일치를 이용한 지문 정합 방법 (Fingerprint Minutia Matching Using Local Alignment)

  • 이동재;이상준;김재희
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(4)
    • /
    • pp.195-198
    • /
    • 2001
  • We proposes a new fingerprint minutia matching algorithm which matches the fingerprint minutiae by using local alignment. In general, fingerprint is deformed by Pressure and orientation when a user presses his fingerprint to the sensor. These nonlinear deformations change the position and the orientation of minutiae which decrease reliability of minutiae. Matching by using global alignment uses one alignment point. But, the problem with this method is that, due to the deformation, matching reliability of a minutia decreases as the distance from the alignment minutia increases. Matching by using local alignment overcomes this problem by considering minutiae which are located in a short distance boundary. Experimental results show that the performance of the proposed algorithm is superior to that of using global alignment.

  • PDF

컴퓨터를 이용한 지구관측 카메라의 광학정렬 (Computer-Aided Alignment of an Earth Observation Camera)

  • 김도형;최영완;강명석;김이을;양호순
    • 한국항공우주학회지
    • /
    • 제32권10호
    • /
    • pp.142-146
    • /
    • 2004
  • 인공위성용 지구관측 카메라나 천문관측 망원경에는 무게와 부피의 제약 때문에 Cassegrain 방식 망원경이 많이 쓰인다. 이와 같은 위성용 광학계의 성공적인 임무 수행을 위해서는 광학계의 정밀 정렬이 필수적이다. 본 논문에서는 인공위생용 지구관측 카메라인 MAC (Medium-sized Aperture Camera)의 조립 과정에 적용된 컴퓨터를 이용한 광학정렬 방법의 모사와 정렬실험 결과를 정리한다.

Symmetric-viewing liquid crystal display with alternating alignment layers in an inverse-twisted-nematic configuration

  • Na, Jun-Hee;Li, Hongmei;Park, Seung-Chul;Lee, Sin-Doo
    • Journal of Information Display
    • /
    • 제12권4호
    • /
    • pp.191-194
    • /
    • 2011
  • A symmetric-viewing inverse-twisted-nematic (ITN) liquid crystal display (LCD) with alternating alignment layers was developed using a stamping-assisted rubbing (SAR) technique. A patterned layer of a fluorinated acrylate polymer was transferred onto the first rubbed vertical-alignment layer prepared on a substrate by stamping. The fluorinated acrylate polymer provided a protective layer covering the first rubbed alignment layer during the second rubbing process, which promoted the vertical alignment of the LC molecules. The LC cell in the ITN geometry with two orthogonally rubbed alignment layers showed symmetric-viewing characteristics with fourfold symmetry. The SAR technique was shown to be a mask-free alignment method of producing multidomains for symmetric-viewing LCDs.

고차 다항식 변환 기반 카메라 캘리브레이션을 이용한 웨이퍼 Pre-Alignment 시스템 (A Wafer Pre-Alignment System Using a High-Order Polynomial Transformation Based Camera Calibration)

  • 이남희;조태훈
    • 반도체디스플레이기술학회지
    • /
    • 제9권1호
    • /
    • pp.11-16
    • /
    • 2010
  • Wafer Pre-Alignment is to find the center and the orientation of a wafer and to move the wafer to the desired position and orientation. In this paper, an area camera based pre-aligning method is presented that captures 8 wafer images regularly during 360 degrees rotation. From the images, wafer edge positions are extracted and used to estimate the wafer's center and orientation using least squares circle fitting. These data are utilized for the proper alignment of the wafer. For accurate alignments, camera calibration methods using high order polynomials are used for converting pixel coordinates into real-world coordinates. A complete pre-alignment system was constructed using mechanical and optical components and tested. Experimental results show that alignment of wafer center and orientation can be done with the standard deviation of 0.002 mm and 0.028 degree, respectively.

Stamping-assisted Fabrication Technique of the Bidirectional Alignment Layer for Wide-Viewing Twisted-Nematic Liquid Crystal Displays

  • Koo, Kyung-Mo;Na, Jun-Hee;Kim, Yeun-Tae;Li, Hongmei;Lee, Sin-Doo
    • Journal of Information Display
    • /
    • 제10권4호
    • /
    • pp.180-183
    • /
    • 2009
  • A stamping-assisted rubbing technique for generating bidirectional alignment in the fabrication of wide-viewing twistednematic (TN) liquid crystal displays (LCDs) was developed. A patterned layer of a fluorinated acrylate polymer was transferred onto the first rubbed alignment layer prepared on a substrate by stamping. The fluorinated acrylate polymer provides a protective layer that covers the first alignment layer during the second rubbing process to facilitate the bidirectional alignment of the LC molecules. The LC cell in the twisted geometry with two bidirectional-alignment layers showed stable electro-optic properties and wide-viewing characteristics. The stamping-assisted rubbing technique serves as a mask-free alignment method of producing multidomains for wide-viewing LCDs.

마이크로 패터닝 가공을 위한 공구 정렬에 관한 연구 (Sharp Edge Tool Alignment for Micro Pattern Machining)

  • 박순섭;원종호
    • 한국기계가공학회지
    • /
    • 제8권3호
    • /
    • pp.1-6
    • /
    • 2009
  • This paper presents a geometrical error compensation of tool alignment for sharp edge bite on B axis controlled machine. In precision micro patterning, bite alignment is crucial parameter for machined surface. To decrease bite alignment error, plus tilted bite from B axis center is touched to reference work piece(pin gauge) and checked the deviation from original position. Same process is repeated for maximum touch deviation value. From this touched position value, wheel alignment error in X axis and Z axis can be calculated on B axis center. Experimental results show that this compensation method is efficient to correct sharp edge bite alignment.

  • PDF