• Title/Summary/Keyword: Alignment Measurement

Search Result 338, Processing Time 0.032 seconds

Study of Properties of High-K Strontium Oxide Alignment Layer Using Solution Process for Low Power Mobile Information Device (저전력 휴대용 통신단말을 위한 Solution Process를 이용한 고 유전율 Strontium Oxide 배향막의 특성 연구)

  • Han, Jeong-Min;Kim, Won-Bae
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.2
    • /
    • pp.90-94
    • /
    • 2015
  • We stuidied liauid crystal alignment treatment using solution process for making thin oxide layer in liquid crystal display. It is the one of very effient and popular process in making thin oxide layer in electronical industrial fields. Particularly, this process has highly potential value in liquid crystal display industrial fields because it cause automatically induced alignment process without tranditional alignment process in liquid crystal alignment process. We made several different kinds of mol density solutions using strontium oxide solution. And those solutions were treated for solidification layers using annealing process for 2 hours. And we stuided pretilt angle properties of these alignment layers of strontium oxide for clarifying the relationship of liquid crystal molecules and thin strontium oxide layer. And we also tested the existence of strontium oxide thin layer on substrate using XPS measurement. We expected the hig gain of electro-optical properties in liquid crystal display using strontium oxide thin layer because it has high K property material than the other metal-based oxide layers. In this results, we measured 1.447 to 1.613 thresholds volts as 0.1 mol to 0.4 mol density in 0.1 mol density steps. This is significant better characteristics than conventional liquid crystal display as higher than 1.85 thresholds volts. And it make possible to making next-generation liquid crystal display which present low-power consumption and wide gray scale in liquid crystal display.

Precise Measurement of Ultra Small Retardation of Rubbed Polyimide Alignment Layer Using an Improved Transmission Ellipsometer (개선된 투과형 타원계를 사용한 러빙된 Polyimide 배향막의 초미세 위상지연 정밀 측정)

  • Lyum, Kyoung Hun;Park, Sang Uk;Yang, Seong Mo;Yoon, Hee Kyu;Kim, Sang Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.2
    • /
    • pp.77-85
    • /
    • 2013
  • The precision of retardation measurement has been improved upto $3{\sigma}$ <0.005 nm after improvements are made to the conventional transmission ellipsometer. Improvements are made such that, i) the polarizer module instead of the sample stage is rotated, ii) the light source is replaced, iii) the starting points of two rotating modules are accurately synchronized, and iv) the fine background retardation is compensated. Together with the newly introduced RVD (Retardation Vector Difference) method, the improved instrument is successfully applied to characterize the ultra small optical birefringence of the rubbed polyimide alignment layer, after the residual retardation due to glass substrate whose magnitude is about 1.0 nm is properly subtracted. It is verified that the net retardation of the alignment layer ranges from 0.05 nm to 0.15 nm.

Reference X-ray Irradiation System for Personal Dosimeter Testing and Calibration of Radiation Detector

  • Lee, Seung Kyu;Chang, Insu;Kim, Sang In;Lee, Jungil;Kim, Hyoungtaek;Kim, Jang-Lyul;Kim, Min Chae
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.72-78
    • /
    • 2019
  • Background: In the calibration and testing laboratory of Korea Atomic Energy Research Institute, the old X-ray generator used for the production of reference X-ray fields was replaced with a new one. For this newly installed X-ray irradiation system, beam alignment as well as the verification of beam qualities was conducted. Materials and Methods: The existing X-ray generator, Phillips MG325, was replaced with YXLON Y.TU 320-D03 in order to generate reference X-ray fields. Theoretical calculations and Monte Carlo simulations were used to determine initial filter thickness. Beam alignment was performed in three steps to deliver a homogeneous radiation dosage to the target at different distances. Finally, the half-value layers were measured for different X-ray fields to verify beam qualities by using an ion chamber. Results and Discussion: Beam alignment was performed in three steps, and collimators and other components were arranged to maintain the uniformity of the mean air kerma rate within ${\pm}2.5%$ at the effective beam diameter of 28 cm. The beam quality was verified by using half-value layer measurement methods specified by American National Standard Institute (ANSI) N13.11-2009 and International Organization for Standardization (ISO)-4037. For each of the nine beams than can be generated by the new X-ray irradiation system, air kerma rates for X-ray fields of different beam qualifies were measured. The results showed that each air kerma rate and homogeneity coefficient of the first and second half-value layers were within ${\pm}5%$ of the recommended values in the standard documents. Conclusion: The results showed that the new X-ray irradiation system provides beam qualities that are as high as moderate beam qualities offered by National Institute of Standards and Technology in ANSI N13.11-2009 and those for narrow-spectrum series of ISO-4037.

Manufacture of Daily Check Device and Efficiency Evaluation for Daily Q.A (일일 정도관리를 위한 Daily Check Device의 제작 및 효율성 평가)

  • Kim Chan-Yong;Jae Young-Wan;Park Heung-Deuk;Lee Jae-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.105-111
    • /
    • 2005
  • Purpose : Daily Q.A is the important step which must be preceded in a radiation treatment. Specially, radiation output measurement and laser alignment, SSD indicator related to a patient set-up recurrence must be confirmed for a reasonable radiation treatment. Daily Q.A proceeds correctness and a prompt way, and needs an objective measurement basis. Manufacture of the device which can facilitate confirmation of output measurement and appliances check at one time was requested. Materials and Methods : Produced the phantom formal daily check device which can confirm a lot of appliances check (output measurement and laser alignment. field size, SSD indicator) with one time of set up at a time, and measurement observed a linear accelerator (4 machine) for four months and evaluated efficiency. Results : We were able to confirm an laser alignment, field size, SSD indicator check at the same time, and out put measurement was possible with the same set up, so daily Q.A time was reduced, and we were able to confirm an objective basis about each item measurement. As a result of having measured for four months, output measurement within ${\pm}2%$, and measured laser alignment, field size, SSD indicator in range within ${\pm}1mm$. Conclusion : We can enforce output measurement and appliances check conveniently, and time was reduced and was able to raise efficiency of business. We were able to bring a cost reduction by substitution expensive commercialized equipment. Further It is necessary to makes a product as strong and slight materials, and improve convenience of use.

  • PDF

Characteristics of the Running behavior for Tilting train due to Alignment based on Numerical analysis (틸팅열차의 주행거동과 방향틀림에 대한 수치해석적 고찰)

  • Lim, Yun-Sik;Choi, Il-Yoon
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3187-3194
    • /
    • 2011
  • Vehicle dynamic behavior should be investigated to establish the track irregularity criteria because they have an impact on vehicle dynamic behavior. The tilting train which have been developed in Korea will be operated on the conventional line. Therefore, it should be checked that the track irregularity criteria of conventional line is still available for the new vehicle. In this paper, the influence of alignment on running behavior and safety for tilting train was instigated by numerical analysis. The wavelength and amplitude of alignment were considered in scenario of this numerical analysis. This research is based on just numerical analysis and the final result which include measurement will be published in the future.

  • PDF

A Technique for Alignment to True North Using Image Processing (영상 선호 처리를 이용한 풍향센서의 진북맞추기)

  • Lee, Jeong-Wan;Nam, Yoon-Su;Yoo, Neung-Soo
    • Journal of Industrial Technology
    • /
    • v.22 no.A
    • /
    • pp.67-72
    • /
    • 2002
  • A technique for alignment to true north is presented, based on synchronized measurements of vision image by a camera and output voltage of wind direction sensor. The true wind direction is evaluated by means of image processing techniques with least square sense, and then evaluated true value is compared with measured output voltage of the sensor. The proposed technique is applied to real meteorological tower m Daekwanryung test site. In addition, some uncertainty analysis of this method is presented.

  • PDF

Precision Measurement for Aircraft Alignment using Industrial Photogrammetry (산업사진측량을 이용한 항공기 얼라인먼트 정밀측정)

  • Jung, Sung-Heuk;Lee, Jae-Kee
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.6
    • /
    • pp.57-63
    • /
    • 2005
  • According to increasing of demand for high accurate and quick measuring technology, they became to interest in industrial photogrammetry that can satisfy with this needs. This study is examined O-2A aircraft to check the application of Industrial Photogrammetry technology. To measure the aircraft alignment, the check points marked on it were used without exact aircraft design data. And to check any deformation of its external original feature, Pro-spot system has been used.

Electro-optical Characteristics in the Vortical-Alignment 1/4$\pi$ Cell by photoalignment Method (광배향법을 이용한 VA-l/4$\pi$셀의 전기 광학 특성)

  • 이윤건;황정연;서대식;김재형
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.369-372
    • /
    • 2001
  • We studied the electro-optical (EO) performance in the vertical-alignment (VA) - l/4$\pi$ cell photoaligned with polarized UV exposure on a homeotropic photopolymer surfaces. Excellent voltage-transmittance curve in the VA - l/4$\pi$ cell photoaligned with polarized UV exposure for 3 min on the photopolymer containing cholesterol group of 8% can be achieved. The V-T characteristics in the VA-l/4$\pi$ cell photoaligned on the photopolymer surface can be improved by increasing cholesteryl group. For response time measurement, the transmittance characteristics of the VA-l/4$\pi$ cell photoaligned on the photopolymer surface was better than that of the VA-l/4$\pi$ cell rubbingaligned on a polyimide(Pl) surface.

  • PDF

EO Characteristics in the Vertical-Alignment (VA)-In Plane Swiching (IPS) Cell on a Homeotropic Photopolymer Surface (수직 광폴리머 표면을 이용한 VA-IPS 셀의 전기 광학 특성)

  • Pieh, Sung-Hoon;Hwang, Jeoung-Yeon;Kim, Jae-Hyung;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.945-948
    • /
    • 2002
  • We studied electro-optical (EO) performances of a vertical-alignment (VA)-in plane switching (IPS) cell on a photopolymer surfaces. The VA-IPS cell, dark in voltage-off state, reveals bright uniformity in all directions due to the dual domainlike dierector configuration in the voltage-on state. For voltage-transmittance (V-T) measurement, the transmittance characteristics of the VA-IPS cell on the photopolymer surface was better than that of the VA-IPS cell on a polyimide(PI) surface.

  • PDF