• Title/Summary/Keyword: Air-temperature variation

Search Result 925, Processing Time 0.034 seconds

On the Characteristics of Globe Temperature Variation Observed at Downtown in Summer Season (하계에 도심지에서 관측된 흑구온도의 특성 분석)

  • Park, Jong-Kil;Jung, Woo-Sik;Kim, Seok-Cheol;Park, Gil-Un
    • Journal of Environmental Science International
    • /
    • v.17 no.8
    • /
    • pp.907-918
    • /
    • 2008
  • In order to monitor the impact of high temperature which is seen frequently with climate change, we investigated the monthly change in globe temperature, air temperature, mean radiant temperature and effective radiant heat flow, because the four well reflect thermal radiation from bio-meteorological aspect. Both globe temperature and air temperature showed an increasing trend every month. Compared to air temperature, globe temperature had a wider range of temperature change and was more influenced by meteorological element such as precipitation. Diurnal trends of air temperature, globe temperature and the difference between their temperature had the lowest value before the sunrise and the highest around $1300{\sim}1500$ LST, showing the typical diurnal trends. Globe temperature and the difference between their temperature had a sharp increase around $1000{\sim}1100$ LST, maintained high value until 1700 LST and then reclined, though varied by month. The difference between globe temperature and air temperature was highly dependent on the amount of precipitation and clouds. The duration in which globe temperature was higher than air temperature was the lowest in July. Therefore the amount of precipitation was the most affecting, followed by the amount of clouds and wind. In order to find out the diurnal trends of temperature in city center and city outskirts, we assumed the roof of a concrete build ing as a city center, and the grass-covered observatory of the Gimhae International Airport as city outskirts. The diurnal trends of temperature in the two sites showed a strong correlation. The highest and lowest temperature also had the same trend.

A Study on the Characteristics of Heat Transfer in Quadrangle Duct with Solar Absorber Plate (태양열 집열면이 있는 4각 덕트 내의 열전달 특성에 관한 연구)

  • 고동국;조대진;윤석주;박상규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1014-1022
    • /
    • 2002
  • This paper analyzed the characteristics of heat transfer in quadangle duct with absorber plate by solar radiation. Effects o( Reynolds number on increasing temperature at outlet for variation of absorber plate temperature were analyzed by using numerical analysis technique. And also the effects of turbulent intensity of inlet flow on increasing temperature at outlet for various duct height and effects of inlet aspect ratio of quadrangle duct and position of heating surface on the outlet temperature were analysed. As the results, Outlet temperature was greatly influenced in low Reynolds number. And the highest outlet temperature distribution appeared on the inlet aspect ratio 2 because of the buoyancy effect.

Numerical Quadrature for the Prandtl Meyer Function at High Temperature with Application for Air

  • Zebbiche, Toufik
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.9 no.2
    • /
    • pp.9-17
    • /
    • 2008
  • When the stagnation temperature of the combustion chamber or ambient air increases, the specific heats and their ratio do not remain constant any more, and start to vary with this temperature. The gas remains perfect, except, it will be calorically imperfect and thermally perfect. A new generalized form of the Prandtl Meyer function is developed, by adding the effect of variation of this temperature, lower than the threshold of dissociation. The new relation is presented in the form of integral of a complex analytical function, having an infinite derivative at the critical temperature. A robust numerical integration quadrature is presented in this context. The classical form of the Prandtl Meyer function of a perfect gas becomes a particular case of the developed form. The comparison is made with the perfect gas model for aim to present a limit of its application. The application is for air.

A study on cooling characteristics of clathrate compound for cold storage applications (저온축열용 포접화합물에 냉각특성에 관한 실험적 연구)

  • 한영옥;김진흥
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.205-214
    • /
    • 1999
  • The objective of this paper is to investigate the thermal properties of TMA clathrate compound applicable to cold storage system for building air-conditioning. Especially, the test tube experiments are performed by comparing and analyzing the temperature of phase change, specific heat and subcooling characteristic according to the variation of density, temperature of heat source and charging quantity in TMA clathrate compound. The results are summarized as follows:1) $-15^{\circ}C$ is not proper as the temperature of heat source because the temperature of subcooling is above $8.3^{\circ}C$ 2) temperature of phase change is dropped as the temperature of heat source is lower, 3) the effect of subcooling suppression with about 8$^{\circ}C$ is confirmed when the temperature of heat source is $-10^{\circ}C$ in case of 26, 27, and 30wt%, while the temperature of subcooling is about $0^{\circ}C$ when the temperature of heat source is $-15^{\circ}C$ in case of 25, 26 and 30wt%. Thus, the effect of subcooling suppression is greater as the temperature of heat source is lower. Additionally, the concentrative study is needed on mass concentration causing the phase change without subcooling phenomenon when the temperature of heat source is $-15^{\circ}C$. Thus, it is concluded that TMA clathrate compound has enough thermal properties as the cold storage medium for building air-conditioning.

  • PDF

Variation Analysis of CO2 Concentrations at Sunset before and after of Summer Season at the Foreshore (갯벌에서 여름철 일몰 전후 이산화탄소 농도 변동 분석)

  • Kang, Dong Hwan;Kwon, Byung Hyuk;Kim, Park Sa
    • Journal of Environmental Science International
    • /
    • v.23 no.3
    • /
    • pp.399-407
    • /
    • 2014
  • In this study, before and after sunset carbon dioxide concentration and air temperature were observed in two points of atmosphere (lower observation point of the GL + 0.1 m, the upper observation point of GL + 1.0 m) on the foreshore at located in Suncheon Bay and their variations were analyzed. Observation was performed on the foreshore on 2~4 August 2010. Instrument (VAISALA, GMP343) was set two hours before sunset and then observation was made continuously for six hours. In three days, observed carbon dioxide concentration was 375~419 ppm, and the air temperature was in the range of $28.7{\sim}32.5^{\circ}C$. The average concentration of carbon dioxide was 388~399 ppm in the upper observation point and 386~396 ppm in the lower observation point. It was higher in the upper observation point and its fluctuations were similar in two observation points. Correlation coefficients between carbon dioxide concentration and air temperature in the upper observation point were in the range of -0.64~-0.88, and were calculated -0.65 to -0.90 in the lower observation point. For the carbon dioxide concentration, correlation coefficients between the upper part and the lower part were very high as 0.98 in three times. For the air temperature, correlation coefficients between the upper part and the lower part were very high as 0.97 and 0.99. In the same observation time, the slope of the linear regression function as carbon dioxide concentration in the lower observation point for the upper observation point was in the range of 0.97~1.01. Carbon dioxide concentration was slightly higher in the upper observation point. Because carbon dioxide in the lower observation point was closer on the surface of the foreshore and absorbed from atmosphere to the foreshore. In this study, it was showed that the vertical variation of carbon dioxide concentration was insignificant in the several meter scale of atmosphere on the surface of the foreshore.

A Study on the Characteristics of Environmental Factors of Granite Dome Models with Different Material during Winter Season

  • Kong, Sung-Hoon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.1
    • /
    • pp.71-76
    • /
    • 2001
  • Factors governing the rate of heat exchange comprise temperature, air velocity, relative humidity, and relation indoors. Recently, there are many researches on the transient analysis of indoor environmental factors such as dry bulb temperature, relative humidity and air velocity in miniature models. The purpose of this study is to measure the environmental factors and to analyze and evaluate the characteristics of indoor environment in different envelop structures using granite dome models. The interior relative humidity is constant regardless of exterior humidity although a little range of variation is shown in comparison to the cement model.

  • PDF

Cool Island Intensity in a Large Urban Green in Downtown Daegu: Seasonal Variation and Relationship to Atmospheric Condition (대구 도심에 위치한 대규모 녹지공간의 냉섬 강도: 계절변화와 기상조건에의 관련성)

  • Park, Myong-Hee;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.19 no.1
    • /
    • pp.81-87
    • /
    • 2010
  • Cool island intensity urban green space was investigated based in Dalsung Park, that is one of the largest parks in Daegu. Cool island intensity(CII), which is defined as the temperature difference between the green space and its surrounding built-up areas, shows time variations. A through-year measurement(2008-2009) of ground level air temperature revealed seasonal variation and relationship to the atmospheric condition of CII. The temperature variation in the park and the reference downtown Daegu was as same order as CII. The noontime CII is larger in summer than that in winter due to the leaf fall of the park trees. On the other hand, seasonal variation of nighttime CII is not so clear. The nighttime CII was larger under the stable atmosphere.

Evaluation of Temperature and Precipitation on Integrated Climate and Air Quality Modeling System (ICAMS) for Air Quality Prediction (대기질 예측을 위한 기후·대기환경 통합모델링시스템 (ICAMS)의 기온 및 강수량 예측 능력 평가)

  • Choi, Jin-Young;Kim, Seung-Yeon;Hong, Sung-Chul;Lee, Jae-Bum;Song, Chang-Keun;Lee, Hyun-Ju;Lee, Suk-Jo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.6
    • /
    • pp.615-631
    • /
    • 2012
  • This study provides an evaluation for capability of Integrated Climate and Air quality Modeling System (ICAMS) on future regional scale climate projection. Temperature and precipitation are compared between ground-level observation data and results of regional models (MM5) for the past 30 years over the Korean peninsula. The ICAMS successfully simulates the local-scale spatial/seasonal variation of the temperature and precipitation. The probability distribution of simulated daily mean and minimum temperature agree well with the observed patterns and trends, although mean temperature shows a little cold bias about $1^{\circ}C$ compared to observations. It seems that a systematic cold bias is mostly due to an underestimation of maximum temperature. In the case of precipitation, the rainfall in winter and light rainfall are remarkably simulated well, but summer precipitation is underestimated in the heavy rainfall phenomena of exceeding 20 mm/day. The ICAMS shows a tendency to overestimate the number of washout days about 7%. Those results of this study indicate that the performance of ICAMS is reasonable regarding to air quality predication over the Korean peninsula.

The Stream and Exhaust Gas Characteristics for Variation of Exhaust Gas Temperature of Marine Incinerator Ejector (선박용 소각로 이젝터의 배출온도 변화에 따른 유동과 배기특성)

  • 김태한
    • Journal of Ocean Engineering and Technology
    • /
    • v.14 no.2
    • /
    • pp.60-64
    • /
    • 2000
  • An experimental study was performed to investigate the optimal ejector and operating condition of vessel incinerator. Exhaust gas temperature and secondary air which makes vacuum pressure at ejector throat regions were considered as an important factor. According to the measurement of pressure temperature and nitrogen oxides between non combustion and combustion we found the stream and exhaust gas characteristics of incinerator. This results can give us the exhaust gas temperature control system air pollutant reduction method and the optimum ejector design.

  • PDF

Generation characteristics of transparent BIPV module according to temperature change (건물일체형 투명 모듈의 온도 변화에 따른 발전 특성)

  • Park, Kyung-Eun;Kang, Gi-Hwan;Kim, Hyun-Il;Yu, Gwon-Jong;Jang, Dae-Ho;Lee, Moon-Hee;Kim, Jun-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.210-211
    • /
    • 2007
  • Amid booming PV(photovoltaic) industry, BIPV(Building Integrated PV) is one of the best fascinating PV application technologies. To apply PV in building, variable factors should be reflected such as installation position, shading, temperature effect and so on. Especially a temperature should be considered, for it affects both electrical efficiency of PV module and heating and cooling load in building. Transparent PV modules were designed as finished material for spandrels are presented in this paper. The temperature variation of the modules with and without air gap and insulation were compared and analyzed. The results showed that the module with air gap and insulation has a much larger temperature variation than another transparent module. The temperature of the module reached by 55degree C under vertical irradiance of lower 500$W/m^2$. And the temperature difference between these modules was about 15degree C. To analyze the output performance of module according to temperature variation, separate module was manufactured and measured by sun-simulator. The results showed that 1 degree temperature rise reduced about 0.45% of output power.

  • PDF