• 제목/요약/키워드: Air-leakage rate

검색결과 144건 처리시간 0.024초

공기압 서보밸브 특성해석 및 실험 (Characteristic Analysis and Experiment of Pneumatic Servo Valve)

  • 김동수;이원희;최병오
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.967-973
    • /
    • 2004
  • Electro-pneumatic servo valve is an electro-mechanical device which converts electric signals into a proper pneumatic flow rate or pressure. In order to improve the overall performance of pneumatic servo systems, electro-pneumatic servo valves are required, which have fast dynamic characteristics, no air leakage at a null point, and can be fabricated at a low-cost. The first objective of this research is to design and to fabricate a new electro-pneumatic servo valve which satisfies the above-mentioned requirements. In order to design the mechanism of the servo valve optimally, the flow inside the valve depending upon the position of spool was analyzed variously, and on the basis of such analysis results, the valve mechanism, which was formed by combination of the spool and the sleeve, was designed and manufactured. And a tester for conducting an overall performance test was designed and manufactured, and as a result of conducting the flow rate test, the pressure test and the frequency test on the developed pneumatic servo valve.

  • PDF

노인성 자연 기흉의 치료방법 및 그 결과;50세 이상환자 60례 대상 (Treatment of Spontaneous Pneumothorax; in Patients 50 Years of Age or Older)

  • 조선환
    • Journal of Chest Surgery
    • /
    • 제26권7호
    • /
    • pp.532-537
    • /
    • 1993
  • To assess the therapy of spontaneous pneumothorax in the aged patients, the treatment methods and results in 60 patients 50 years of age or older were retrospectively reviewed. Most of the patients were male [56 of 60 patients] and the major underlying lung diseases associated with spontaneous pneumothorax were tuberculosis [32 patients] and chronic obstructive lung disease [20 patients]. The recurrence rate of thoracostomy tube drainage with or without chemical pleurodesis using tetracycline was 39.6% [21 of 53 patients], but there was no recurrence in the patients treated with open thoracotomy, pleural abrasion, and chemical pleurodesis using talcum powder[Asbestosis free]. In the patients treated with open thoracotomy, the bullous or bleb lesions were placed in the various sites of both lungs. We concluded that even though thoracostomy tube drainage is the first choice of therapy for spontaneous pneumothorax in the aged patients, the recurrence rate is high, especially in the patients with persistent air leakage for more than 2 days, and the open thoracotomy with pleural abrasion and chemical pleurodesis using talcum powder can prevent the recurrence in the selected patients.

  • PDF

Air Tightness Performance of Residential Timber Frame Buildings

  • Kim, Hyun-Bae;Park, Joo-Saeng;Hong, Jung-Pyo;Oh, Jung-Kwon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권2호
    • /
    • pp.89-100
    • /
    • 2014
  • Energy consumption statistics in 2005 from the Korea Energy Management Corporation show that building energy usage was about 24.2% of total domestic energy consumption, and 64% of total building energy usage was consumed by residential buildings. Thus, about 10% of total domestic energy consumption is due to the heating of residential buildings. Building energy can be calculated by the configuration of the building envelope and the rate of infiltration (the volume of the infiltration of outdoor air and the leakage of indoor air), and by doing so, the annual energy usage for heating and cooling. Therefore, air-tightness is an important factor in building energy conservation. This investigate air infiltration and various factors that decrease it in timber frame buildings and suggest ways to improve air-tightness for several structural types. Timber frame buildings can be classified into light frame, post and beam, and log house. Post and beam includes Han-ok (a Korean traditional building). Six light frame buildings, three post and beam buildings, one Korean traditional Han-ok and a log house were selected as specimens. Blower door tests were performed following ASTM E779-03. The light frame buildings showed the highest air-tightness, followed by post and beam structures, and last, log houses.

ZnO 나노파우더로 제조된 Bi계 바리스터의 가속열화 특성 (The Characteristics on the Accelerated Degradation of Bi-based Varistor fabricated with ZnO Nano-powder)

  • 왕민성;왕증매;이동규;박춘배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.203-204
    • /
    • 2006
  • Nano-Varistors fabricated with ZnO 30nm and 80nm powders were studied about the electrical characteristics with AC accelerated degradation in this paper Especially, ZnO nano-powder varistors were sintered m air at $1050^{\circ}C$ and analyzed the phenomenons of before and after AC degradation test. The stress conditions of AC degradation test were $1.0V_{1mA}$ $115{\pm}2^{\circ}C$ for 24h. 80nm-varistor was exhibited better performance than 30nm-varistor m the electrical stabilities. And then 80nm-varistor resulted m the degradation characteristics that the variation rate of operating voltage, nonlinear coefficient and leakage current was -0 3%, -0 4% and -3 3%, respectively.

  • PDF

Design and Fabrication of a Micro PZT Cantilever Array Actuator for Applications in Fluidic Systems

  • Kim Hyonse;In Chihyun;Yoon Gilho;Kim Jongwon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권8호
    • /
    • pp.1544-1553
    • /
    • 2005
  • In this article, a micro cantilever array actuated by PZT films is designed and fabricated for micro fluidic systems. The design features for maximizing tip deflections and minimizing fluid leakage are described. The governing equation of the composite PZT cantilever is derived and the actuating behavior predicted. The calculated value of the tip deflection was 15 ${\mu}m$ at 5 V. The fabrication process from SIMOX (Separation by oxygen ion implantation) wafer is presented in detail with the PZT film deposition process. The PZT films are characterized by investigating the ferroelectric properties, dielectric constant, and dielectric loss. Tip deflections of 12 ${\mu}m$ at 5 V are measured, which agreed well with the predicted value. The 18 ${\mu}l/s$ leakage rate of air was observed at a pressure difference of 1000 Pa. Micro cooler is introduced, and its possible application to micro compressor is discussed.

오일 용해도를 고려한 $CO_2$ 트윈 로타리 압축기 성능해석 (Solubility Consideration in Performance Analysis of a $CO_2$ Twin Rotary Compressor)

  • 김우영;안종민;김현진;조성욱
    • 설비공학논문집
    • /
    • 제19권12호
    • /
    • pp.842-849
    • /
    • 2007
  • For a $CO_2$ two-stage twin rotary compressor used for heat pump water heater system, changes of $CO_2$ solubility in PAG oil were investigated along the gas passages from the first stage suction to final discharge. Only slight changes in solubility took place in suction chambers for both of the first and second stages, but for compression chambers, solubility variation ranged from 0.115 to 0.136, and from 0.133 to 0.182, respectively for the first and second stages. Calculation of gas flashing in parts of leakage oil flows and of oil contained in control volumes due to solubility changes was conducted and included in gas pressure calculation. For the second stage, gas flashing amounts to around $5%\sim6%$ for most leakage flows. Cooling capacity, compressor input, and COP obtained by calculation were well compared to the experimental results. Effects of operation speed on the compressor performance was also studied: as the shaft speed increased, adiabatic efficiency decreased rapidly due to increased over-compression loss.

에어 포일 스러스트 베어링의 탑포일 경사면 형상이 유동특성에 미치는 영향에 대한 수치해석 연구 (The Effects of Inclined Foil Shape on Flow Characteristics in Air Foil Thrust Bearing Using CFD)

  • 백건웅;주원구;문형욱;황성현;정성윤;박정구
    • Tribology and Lubricants
    • /
    • 제37권4호
    • /
    • pp.117-124
    • /
    • 2021
  • In this study, we perform a 3D CFD conjugate analysis according to the shape of the foil ramp of the air foil thrust bearing, analyze the flow characteristics inside the bearing, and compare the results corresponding to the two shapes. Air has a lower viscosity than lubricating oil. Therefore, the thrust runner of the bearing must rotate at high speed to support the load. The gap between thrust runner and foil is significantly smaller than that of the oil bearing. Hence, it is crucial to analyze the complex flow characteristics inside the bearing to predict the complex flow inside the bearing and performance of the bearing. In addition, flow characteristics may appear differently depending on the ramp shape of the bearing foil, which may affect bearing performance. In this study, we numerically analyze the main flow path of air flowing into the bearing and the secondary flow path used for cooling the bearing using the commercial CFD software ANSYS CFX and compare the flow characteristics for straight and curved foil ramp shapes. Notably, there is a difference in the speed of the flowing air according to the shape of the ramp, which affects the bearing performance.

수소연료전지선박의 탱크 내 누출시나리오에 따른 영향분석 (The Impact Analysis of the Leakage Scenario in the Tank of Hydrogen Fuel Cell Vessel)

  • 임상진;이윤호
    • 한국가스학회지
    • /
    • 제27권1호
    • /
    • pp.13-22
    • /
    • 2023
  • 현재 통용되고 있는 화석연료로부터 발생되는 환경오염에 대한 대안으로써 대기오염이 발생하지 않는 수소를 사용하기 위한 연구가 활발히 이루어지고 있다. 하지만, 최근까지도 수소 누출에 의한 화재 및 폭발사고가 발생함에 따라 특수한 환경인 선박에서 수소를 상용화하기 위해 안전에 관한 연구가 더욱 필요하다. 따라서 본 연구에서는 수소저장탱크가 설비된 수소연료전지 추진선박이 울산 장생포항을 운항하던 중 누출사고가 발생할 경우의 계절별 대안 시나리오와 최악의 시나리오를 가정하였다. 또한, 환경변수를 고려하기 위하여 기상청 2021년도 연평균 기상자료와 통계청 지리정보 자료를 토대로 ALOHA와 프로빗 분석을 통해 피해 영향 범위를 도출하였다. 복사열이 대안 시나리오와 최악의 시나리오 모두에서 과압과 화염의 피해 영향범위 보다 넓은 피해범위가 나타났고 프로빗 분석 결과 가정한 모든 구역에서 99%의 사망률을 확인하였다.

전동차 출입문 전자변 누기고장의 신뢰도 함수와 임무 신뢰도를 고려한 정비 주기 결정 (Determination of Maintenance Period Considering Reliability Function and Mission Reliability of Electromagnetic Valves of EMU Doors Considering Air Leakage Failure)

  • 박희섭;구정서;김길동
    • 한국철도학회논문집
    • /
    • 제20권5호
    • /
    • pp.569-576
    • /
    • 2017
  • 전동차의 공기 작동식 출입문을 작동하기 위한 공기를 공급 또는 차단의 역할을 하는 전자변은 고장발생시 승객의 안전은 물론 정상운행을 불가능하게 하는 중요한 부품이므로 높은 신뢰도가 요구되지만 누기로 인한 고장 비율이 높은 편이다. 국내 도시철도 운영기관들은 고정주기와 임의 여유기간을 적용한 전동차 중정비 주기로 전자변을 정비한다. 현행 중정비 주기 방식의 대안으로 고장 신뢰도를 고려한 정비주기를 제시하고자 지하철 6호선 전동차 전자변 고장 통계자료에 상용 통계프로그램(MINITAB)을 적용하여 신뢰도 함수(Reliability Function)와 임무신뢰도(Mission Reliability)를 계산하고 적정 정비주기를 도출하였다. 도출된 정비 주기는 현 4년 주기의 정비의 부품신뢰도를 68%에서 95%로 향상시키는 것이므로 전자변의 신뢰도를 획기적으로 향상시킬 수 있을 것이다.

1,000 MW 석탄화력발전소 대기환경오염물질 제거효율 향상을 위한 탈황설비 성능개선 (Enhancement of Desulfurization System Efficiency in 1,000 MW Coal-Fired Power Plants)

  • 이영수;문승재
    • 플랜트 저널
    • /
    • 제17권2호
    • /
    • pp.32-41
    • /
    • 2021
  • 최근 미세먼지 등 대기환경 문제가 국가적 이슈로 급부상 하고있는 추세이며 특히 석탄화력발전소에 대한 강도높은 환경규제치가 적용되고 있는 실정이다. 본 연구는 석탄화력발전소 주요 대기오염 배출물질인 황산화물과 먼지 제거를 위한 탈황설비 성능개선 사례에 대해 소개하고 있으며 현재 운영중인 1,000 MW 발전소의 성능개선을 위한 네가지 Case Study를 수행하고 공사를 하였다. 탈황설비 흡수탑 개조를 통해 액기비를 증대시켰으며 산화공기 유량을 증대시켜 기액 반응을 촉진하였다. 또한 가스가스히터 누설률을 개선하여 최종 탈황설비 효율을 향상시켰다. 기존 설비와 조화를 고려한 성능개선 공사를 통해 2023년부터 적용될 규제치(황산화물 25ppm, 먼지 5mg/Sm3)를 만족할 것으로 예상되며 타 화력발전소에 검토 및 적용하는데 참고될 수 있다고 기대된다.