• Title/Summary/Keyword: Air-conditioning System

Search Result 3,318, Processing Time 0.03 seconds

Design of Direct Load Controller for use of Demand Side (수용가용 직접부하제어장치 설계)

  • Park, J.C.;Kim, H.G.;Jeong, B.H.;Kang, B.H.;Choe, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.149-151
    • /
    • 2005
  • Recently, power supply-demand instability due to the dramatic increase in power usage suchas air-conditioning load at summertime has brought forecasts of decrease in power supply capability. Therefore improving the load factor through systematic load management, in other words, Direct Load Control became necessary. Direct Load Control(DLC) system is kind of a load management program for stabilization of electric power supply-demand. It's purpose is limiting the demand of the demand side selected at peak load or other time periods. The paper presented a Design of Direct Load Controller for control the amount of power demand in demand side. The proposed Controller is cheaper and has ability of storing more power data than pre-existing device.

  • PDF

Technology Development Trend of Domestic and Foreign Electric Vehicle and Technology Development Strategy of Domestic Electric Vehicle Core Parts (국내외 전기자동차 기술 개발 동향 및 국내 전기자동차 핵심 부품 기술 개발 전략)

  • Son, Younh-Wook;Huh, Gun-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.5
    • /
    • pp.373-381
    • /
    • 2017
  • The electric vehicle market has increased rapidly in recent years. Established global automakers have announced that electric cars will be developed and distributed. Furthermore, current electric cars are not merely breezes, instead, they are the mainstream of automobiles. However, high prices, short mileage, and long charge times are the main obstacles to the spread of electric vehicles. To solve these problems, the competition for technology development for the expansion of electric vehicles worldwide intensifies because of the improvements in mileage, price reduction, and expansion of charging infrastructure. In this paper, the trends in the development of key technologies for electric vehicles in overseas markets and the present strategic goals for the development of key technologies for electric vehicles in Korea will be identified.

A study on the heat transfer performance of evaporator for absorption chiller (흡수식 냉온수기용 증발기의 전열성능에 관한 연구)

  • Kwon, Oh-Kyung;Cha, Dong-An;Yun, Jae-Ho;Kim, Hyo-Sang
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.192-197
    • /
    • 2008
  • The objectives of this paper are to measure the heat transfer and pressure drop of the heat transfer tube for an evaporator of absorption system applications. Five types of heat transfer tubes with different shape and heat transfer area are tested in the present experiment. Heat transfer and pressure drop performance of heat transfer tubes are measured in various operating conditions, and compared each other. The results show that the heat transfer rate of thermoexcel notch tube and low fin tube increases about 27.6% and 11.6% at the refrigerant flow rate 250 kg/h compared with that of bare tube, respectively. The thermoexcel notch tube is shown the best performance considering pressure drop and heat transfer coefficient.

  • PDF

A Study on Thermal Conductivity Properties of Ground Heat Exchangers for GSHP systems (지열냉난방시스템 수직형 지중열교환기 그라우트의 열적 특성에 관한 연구)

  • Baek, Sung-Kwon;Jeon, Joong-Kyu;An, Hyung-Jun
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.429-433
    • /
    • 2007
  • Cement mortar and concrete can be used as grouts but problems regarding shrinkage and the discord of coefficients of thermal expansion between grouts and HDPE pipes has to be solved. Thermal conductivities of wet condition two times larger than those of dry condition, except for pure cement mortar. The addition of sand into the cement grouts greatly increases the thermal conductivity. The addition of bentonite into the cement grouts reduces thermal conductivity thus reducing the density. Bentonite grouting must be used only below the groundwater table since bentonite grouts possesses high shrinkage property in dry condition. The addition of sand prevents the shrinkage of bentonite grouts. Bentonite manufactured in Korea can be used since they possess similar thermal conductivities with imported products. The addition of sand into the bentonite grouts greatly increases the thermal conductivity.

  • PDF

Development of a Pre/Post Processor Program for the Analysis of the Passenger Flow based on Discrete Element Method(DEM) (DEM에 기초한 여객유동 해석을 위한 전/후처리 프로그램 개발)

  • Kim, Chi-Gyeom;Won, Chan-Shik;Hur, Nahm-Keon;Nam, Seong-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.475-480
    • /
    • 2008
  • A pre/post processor program based GUI(Graphic User Interface) by using the MFC and OpenGL library in the Windows OS have been developed for the analysis of the passenger flow. Using this program, users are able to generate and modify the meshes of multi-storied subway station, set all the parameters for the solver, and obtain the results of the simulation such as transient passenger motions and passenger streak lines in 3-dimensional graphic view.

  • PDF

A Study on the Assessment of Thermal Performance of Plus50 Eco-building (Plus50 환경공생빌딩의 열성능 평가에 관한 연구)

  • Lee, Hong-Cheol;Hwang, In-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.155-160
    • /
    • 2007
  • This study describes thermal performance of Plus50 eco-building with new technology such as power window system, green wall, structure material, etc. The Plus50 eco-building is house experimental which is constructed by Korea Institute of Construction Technology. In order to estimate thermal performance of the building, TRNSYS program and Prebid, and its sub-modules are used. The results showed that maximum heating and cooling load in the building are calculated at 1st floor and 4th floor, respectively. And also energy saving of the building is calculated as over 30% compared to conventional apartment house.

  • PDF

An Estimation of the Economic Life Expectancy of the Building Service Equipment with LCC Analysis (LCC 분석을 통한 공조설비 내구연한 산정)

  • Kang, Sung-Ju;Kim, Yong-Ki;Lee, Tae-Won
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.316-321
    • /
    • 2007
  • It is difficult for a superintendent or an operator of building service systems and equipment to decide the reasonable time for management of himself due to the shortage of his specialty for repair or replacement of a part of or whole equipment. But The reliable life expectancies for various building service equipment have not been prepared yet. This study shows the difference of optimal economic life and the decrease of running cost and energy consumption according to management level of the building equipment by the LCC analysis. The numerical model for building HVAC system was composed and analyses were performed for several parameters with management.

  • PDF

Experimental Study on Naphthalene Heat Pipe Heat Exchanger for Middle-high Temperature Heat Recovery (중고온 범위 폐열회수용 나프탈렌 히트파이프 열교환기에 대한 실험적 연구)

  • Chung, Won-Bok;Park, Soo-Yong;Hwang, Seon-Hong
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.64-69
    • /
    • 2007
  • This study is to develop heat recovery system using high performance heat pipe heat exchanger for Middle-high temperature range industrial exhaust gas. The naphthalene is used as working fluid of heat pipe in this study. Single naphthalene heat pipe could transport over 2,000 watts with $0.05^{\circ}C/W$. The heat pipe heat exchanger consist of 50 naphthalene heat pipes recovered 62 kW when over $400^{\circ}C$ gas exhausted and the maximum recovered heat rate was 173 kW in this study.

  • PDF

A Study on the Hot Spot Cooling Using Thermoelectric Cooler (열전냉각 모듈을 이용한 국소 냉각에 관한 연구)

  • Kim, Ook-Joong;Lee, Kong-Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.640-645
    • /
    • 2007
  • An experimental apparatus to show the hot spot cooling of an IC chip using a thermoelectric cooler is developed. The spot heating in very small area is achieved by the applying CO$_2$ laser source and temperatures are measured using miniature thermocouples. The active effects of thermoelectric cooler on the hot spot cooling system such as rapid heat spreading in the chip and lowering the peak temperature around the hot spot region are investigated. The experimental results are simulated numerically using the TAS program, which the performance characteristics such as Seebeck coefficient, electrical resistance and thermal conductivity of the thermoelectric cooler are searched by trial and error. Good agreements are obtained between numerical and experimental results if the appropriate performance data of the thermoelectric cooler are given.

  • PDF

Performance examination appraisal of gas driven engine heat pump(GHP) (GHP 성능 진단 평가)

  • Kim, Beom-Chan;Park, Jung-Ha;Kim, Sung-Soo;Kang, Yong-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.376-381
    • /
    • 2007
  • GHP system utilize national gas as a heat source. It reduces electric peak demand in summer and maintains a constant performance in winter by recovering the waste heat from the engine. Although the initial investment cost of GHP is higher than that of EHP, the overall operating cost of GHP is cheaper than of the EHP. In this study, items for dissatisfaction were summarized based on the results of user questionnaire(200 users), and field tests were made for 10 GHP installation places. The measured COP was estimated much lower than the rated COP by the manufacturer mainly due to partial load operation.

  • PDF