• 제목/요약/키워드: Air- Permeability

검색결과 591건 처리시간 0.027초

콘크리트 내부 공극 분석을 위한 화상분석기법의 개발 (Development of Image Analysis Techniques for Measuring Air Void System in Hardened Concrete)

  • 전인구;이봉학;윤경구;정원경
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.810-813
    • /
    • 2004
  • Air void systems in hardened concrete has an important influence on concrete durability such as freeze-thaw resistance, water permeability, surface scaling resistance, and etc. Linear traverse method and point count method described at ASTM have been widely used to estimate the air void system in hardened concrete. These methods, however, are rarely used at present, because they require many efforts, are time consuming works, depend on each person's decision, and are not repeatable. Thus, new image analysis method using microscope and computer processes has been approached for analyzing air void system in hardened concrete. However, it is just in initial step. The purposes of this study were to develope an effective and reliable image analysis technique for estimating air void system in hardened concrete. The developed technique was proved to be accurate, reasonable and repeatable.

  • PDF

콘크리트 공극 분석을 위한 평면간격계수의 제안 (Proposal of Plane Spacing Factor for Analyzing Air Void System in Concrete)

  • 정원경;최성용;김성환;윤경구
    • 산업기술연구
    • /
    • 제25권A호
    • /
    • pp.39-47
    • /
    • 2005
  • Air void systems in hardened concrete has an important influence on concrete durability such as freeze-thaw resistance, water permeability, surface scaling resistance. Linear traverse method and point count method described at ASTM are the routine analysis of the air void system that have been widely used to estimate the spacing factor in hardened concrete. Recently, many concretes often have a spacing factor higher than the generally accepted $200-250{\mu}m$ limit for the usual range of air contents. This study is proposed to estimate the plane spacing factor by calculation of simplicity. The plane spacing factor need two parameters that are air content and numbers of air voids in the hardened concrete. Those obtained from the standard air-void system analysis of the ASTM C 457. The equation is valid for all values of paste-to-air ratio because the estimation of paste content is unnecessary at the using ASTM C 457. The plane spacing factor yields a similar estimate of the standard spacing factor.

  • PDF

서열환경하에서의 전투복착용이 체온조절에 미치는 영향 (The Influence of Wearing Army Combat Uniform on the Thermal Responses in Heat Environment)

  • 김태규;조호현
    • 한국의류산업학회지
    • /
    • 제16권1호
    • /
    • pp.167-174
    • /
    • 2014
  • The physical properties of textile materials and thermal physiological responses of the human subjects were evaluated with 4 different types of the army combat uniforms including US, German, Korean and general uniforms for this study. 8 male adults were used as the human subjects and the tests were done in the environmental chamber that was $25{\pm}0.1^{\circ}C$ of temperature, $65{\pm}5%$ of relative humidity and below 0.3 m/sec of air velocity. The test protocol consisted the rest period for 20 min., the exercise period for 20 min., the rest period for 20 min., the exercise period under wind condition for 20 min., and the recovery period for 20 min. The human subjects walked with 4.5 km/hr for 10 min., ran 7.5 km/hr for 10 min. during the first exercise period and walked and ran with the same speeds under 3.5 m/sec of the air velocity that simulated outdoor condition during the second exercise period. The test results of the study were as follows; The wind condition affected the skin and microclimate temperature of the human subjects lower compared to without wind condition, but had insignificant effect on the humidity control. The low air permeability of Korean uniform caused blocking the elimination of the humidity from the body and the regulation of body temperature. However, Korean uniforms could be the excellent one with the designs considering the ventilation of the uniforms and the textile fabrics with better air permeability.

확률적 최적화를 활용한 연속적인 공극비 기울기를 갖는 시멘트 풀 가상 시편 제작 및 투기율 분석 (Evaluation of Air Permeability of Virtual Cement Paste Specimen with Linear Void Ratio Gradient Constructed using Stochastic Optimization)

  • 김세윤;한동석
    • 한국전산구조공학회논문집
    • /
    • 제29권5호
    • /
    • pp.463-469
    • /
    • 2016
  • 본 논문에서는 저차원 확률 함수를 사용하여 연속적인 선형 공극비 기울기를 갖는 기능경사재료 형태의 가상 시편을 제작하였다. 실제 물 시멘트 비가 다른 두 종류 시멘트 풀 시편의 X-선 CT 단면 이미지를 통해 3차원 공극 분포 모델을 제작하여 이를 기반으로 가상 시편을 제작하였다. 가상 시편이 두 실제 시편 사이에 위치하도록 공극 분포 특성을 저차원 확률 함수와 공극비 기울기로 구성하였다. 공극 분포의 기울기는 연속적인 형태의 수직 방향의 선형 공극비 기울기로 구현하며, 이를 위해 확률적 최적화의 목적 함수로 저차원 확률 함수와 공극비 기울기에 관한 함수를 사용하였다. 가상 시편 내 공극 분포 특성 확인을 위해 본 연구에서는 투기율 분석을 유한요소해석을 통해 수행하였다. 공극 분포 특성과 투기율 해석 결과를 비교하여 가상 시편이 갖는 공극 분포 특성이 투기율에 미치는 영향을 확인하고, 투기율의 실제 실험 결과와 해석 결과의 비교를 통해 해석 결과의 타당성을 입증하였다.

FeZrBAg 자성막을 이용한 박막 인덕터의 임피던스 특성 (Characteristics of Thin-Film Inductors Using EeZrBAg Magnetic Thin Films)

  • 송재성;민복기;허정섭;김현식
    • 한국자기학회지
    • /
    • 제10권5호
    • /
    • pp.250-255
    • /
    • 2000
  • 본 연구에서는 double rectangular spiral형 공심 인덕터를 유사 LIGA공정으로, F $e_{86.7}$Z $r_{3.3}$ $B_{4}$A $g_{6}$ 자성막을 dc magnetron sputtering법으로 각각 제조한 후 인덕터의 구조를 변화시켜, 인덕터의 임피던스 특성에 미치는 자성막의 특성 인자에 대해 연구하였다. 공심 인덕터의 전류 방향과 자성 박막의 자화 용이축이 수직일 경우 인덕터의 인덕턴스가 향상되었고, 공심 인덕터와 F $e_{86.7}$Z $r_{3.3}$ $B_{4}$A $g_{6}$ 자성막 사이 절연막이 없는 경우 자성막의 자속 집속효과가 증가하여 절연막이 있는 경우보다 인덕턴스는 높고, 저항의 증가율이 높았으며, F $e_{86.7}$Z $r_{3.3}$ $B_{4}$A $g_{6}$ 자성막의 투자율이 높을수록 인덕터의 인덕턴스에 기여하는 부분이 증가하므로 인턱턴스는 향상되었다. 또한 인덕터의 주파수 특성은 공심 인덕터의 특성에 지배적인 영향을 받으므로 인덕터의 주파수 특성을 향상시키기 위해서는 자성막의 특성보다 공심 인덕터의 특성을 향상시키는 것이 바람직하다.키는 것이 바람직하다.

  • PDF

한지와 레이온 복합사 편성물의 물성 (The Physical Properties of Knitted Fabric with Hanji/Rayon)

  • 김수미;송화순
    • 한국의류학회지
    • /
    • 제37권2호
    • /
    • pp.151-158
    • /
    • 2013
  • This study presents basic knitted fabric data on the use of ply yarn with rayon yarn and eco-friendly/high-valued Hanji yarn. Physical properties (gauge, thickness, burst strength, air permeability, stiffness, Qmax, dimensional stability and surface image) of Hanji 100%, rayon 100% and Hanji/rayon 50:50 knitted fabrics are investigated. The results are as follows. Course direction of gauge decrease in the following order: rayon 100% > Hanji/rayon 50/50 > Hanji 100%. In addition wale direction of gauge decrease in the following order: Hanji 100% > Hanji/rayon 50/50 > rayon 50/50. Thickness and air permeability decrease in the following order: Hanji 100% > Hanji/rayon 50/50 > rayon 100%. Burst strength decrease in the following order: rayon 100% > Hanji 100% > Hanji/rayon 50/50. Stiffness and Qmax decrease in the following order: rayon 100% > Hanji/rayon 50/50 > Hanji 100%. Laundry for dimensional stability is knitted fabric with Hanji/rayon 50/50 than rayon 100% and Hanji 100% improved using neutral detergent and stable at $20^{\circ}C$. From surface image observation, the cracks of Hanji 100% and fibrils of rayon 100% decrease when using knitted fabric with Hanji/rayon 50/50.

혼화재를 사용한 콘크리트의 염소이온 확산 특성 (The Chloride Diffusion Properties of Concrete with Mineral Admixtures)

  • 박정준;고경택;김도겸;김성욱
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.239-246
    • /
    • 2004
  • 콘크리트의 구조물의 내구성을 향상시키기 위해서는 W/C의 감소, 피복두께의 증가, 혼화재의 사용 등을 예로 들 수 있다. 특히, 혼화재를 사용한 경우 콘크리트의 수밀성이 향상되고 구조체의 내구성이 향상되는 것으로 보고되고 있으나 염소이온 확산에 대해서는 보다 체계적인 연구를 수행할 필요가 있다. 또한 혼화재를 사용한 콘크리트의 경우, 혼화재 종류에 따라 포졸란반응 및 잠재수경성 등에 의해 콘크리트 내부조직의 변화가 발생하므로 콘크리트의 염소이온 확산에 대한 보다 정확한 평가를 위해서는 콘크리트 내부의 조직을 평가할 수 있는 요소들을 고려해야 한다. 이에 본 연구에서는 혼화재를 사용한 콘크리트의 내구수명을 평가하기 위한 연구의 일환으로 콘크리트의 압축강도, 공극률, 투기성을 물리적 특성으로 설정하고 이들과 염소이온 확산계수와의 관계를 분석하였다.

감량가공기계에 따른 폴리에스터 직물의 감량특성에 관한 연구 (A Study on the Alkali Hydrolyzed Properties of Polyester Fabric by Various Denier Reduction Range)

  • 허만우;서말용;박성우;한선주;김삼수;이재웅;황종호
    • 한국염색가공학회지
    • /
    • 제12권2호
    • /
    • pp.111-120
    • /
    • 2000
  • In order to make a silk-like polyester fabric, polyester fabrics were treated with a several weight reduction machines such as tank type, liquor flow type and C.D.R at the field condition. The results were as followings : The weft density of treated polyester fabric showed different tendency according to the used the weight reduction machine and the rate of weight loss. Namely, at 6.5% weight loss, the weft density of fabric treated with tank and liquor flow type increased by 1 pick/inch and 2 picks/inch, respectively, and decreased by 4 picks/inch in case of treated with C.D.R type. With the increase in the rate of weight loss, the air permeability of treated fabric increased, and the K/S value of dyed fabric decreased. The overall tendency of the air permeability and the K/S value of treated polyester fabric increased in the order of the tank type, liquor-flow type and C.D.R type. The tensile strength of polyester fabric treated with C.D.R had lower value than that of the other type. It is assumed that this result is attributed the decreasing of the cross point of the warp and weft direction.

  • PDF

견(絹)과 PET 직물(織物)의 오배자(五倍子) 염색(染色) 시(時) chitosan 처리(處理)와 매염(媒染)이 공기투과도(空氣透過度) 및 견뢰도(堅牢度)에 미치는 영향(影響) (Effect of Chitosan and Mordant Treatments on the Air-permeability and Fastness of Silk and PET fabrics Dyed using Rhusjara ica)

  • 홍신지;전동원;김종준;전지혜
    • 패션비즈니스
    • /
    • 제9권1호
    • /
    • pp.113-119
    • /
    • 2005
  • In our previous study, the color development characteristics in the dyeing of silk fibers and PET fibers using Rhusjara ica and related properties were meticulously reviewed. At the same time, the fabric specimens were endowed with chitosan treatment prior to the dyeing procedure in order to investigate the effect of chitosan on the dyeing behavior. The analysis of the colors only, however, would not give us complete elucidation of the effect of fiber characteristics and the mordanting characteristics. In this study, the effect of chitosan and metal mordant treatment in dyeing of silk and PET fabrics using Rhusjara ica has been studied. The change of air-permeability, wash fastness, and light fastness were also investigated.

부직포 접착심지 부착 전후의 접착포의 열적 쾌적성과 공기투과성에 관한 연구 (A Study on the Thermal Comfort and Air Permeability of Adhesive Fabrics Before and After Adhesion of Nonwoven Adhesive Interlining)

  • 김경희;김승진
    • 한국의류학회지
    • /
    • 제22권7호
    • /
    • pp.807-815
    • /
    • 1998
  • Functions of interlinings to the shell fabric are to improve the garment formability for a beautiful silhouette and elastic potential to the deformed fabric during wearing, and also are to enhance appearance and wearing properties of garment. The objective of this study is to analyse the thermal properties of nonwoven fusible interlining to the thin worsted fabric with various fabric structural parameters. For the purpose fo this study, eight specimens with various weft yarn twists and weft densities of thin worsted fabrics are prepared. Three nonwoven fusible interlinings with different structure which were made by Nylon/Polyester were used for adhering to the thin worsted fabrics. Thermal properties of these 24 adhesive fabrics fused with 3 nonwoven interlinings are measured by KES-F7 System for analysing the thermal suitability of nonwoven fusible interlinings to the thin worsted fabrics with various fabric structural parameters. And air permeability, which was measured by KES-F8-API, of 24 nonwoven adhesive interlining fabrics was also analysed and discussed with the various kinds of nonwoven interlinings and fabric structural parameters.

  • PDF