• Title/Summary/Keyword: Air volume fraction

Search Result 173, Processing Time 0.027 seconds

Preliminary Study on the Elemental Quantification of in Ambient Liquid Samples of Microliter Volume Using the In-air Micro-PIXE Technique

  • Ma, Chang-Jin;Lim, Cheol-Soo;Sakai, Takuro
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.54-60
    • /
    • 2017
  • Quantifying the trace elements in infinitesimal ambient liquid samples (e.g., single raindrop, cloud/fog water, and the soluble fraction extracted from the particles collected for a short time) is an important task for understanding formation processes, heating/cooling rates, and their health hazards. The purpose of this study is to employ an in-air micro PIXE system for quantitative analysis of the trace elements in a thimbleful of reference liquid sample. The bag type liquid sample holder originally designed with $10{\mu}m$ thick $Mylar^{(R)}$ film retained the original shape without any film perforation and apparent peaks of film blank by the end of the analysis. As one of tasks to be solved, the homogeneity of the elemental distribution in liquid reference species was verified by the X-ray line profiles for several references. It was possible to resolve the significant peaks for whole target elements corresponding to the channel number of micro-PIXE spectrum. The calibration curves for the six target elements (Si, S, Cl, Fe, Ni, and Zn) in standard solutions were successfully plotted by concentration (ppm) and ROI of interest net counts/dose (nC).

The simulation on the characteristics of ventilation in the subway platform (지하철 승가장내의 환기 특성에 관한 해석적 연구)

  • Park, B.S.;Kim, H.Y.;Kim, Y.G.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.139-145
    • /
    • 2001
  • The purpose of present study is to find design parameters and operating conditions of the HVAC system in a subway platform. The simulation was carried out for the flow, heat and mass transfer for heating, ventilating and air-conditioning(HVAC) environments in the subway platform. The steady-state. incompressible flow assumption and standard $k-{\varepsilon}$ turbulence model are adopted. The location of HVAC air inlet above platform and the volume flow rate of curtain air released from inlet B are chosen as main parameters in this study. The results of present study are following: In the case of existence of train, the heat and contaminant released under the train have no effect on the average temperature and mass fraction of contaminant in the platform, but heat released on the train has influence on the average temperature in the platform. Train acts as an obstacle to exhaust the contaminant in the platform, but has good effect on the average temperature in the platform.

  • PDF

Three-Dimensional Numerical Analysis on Recirculation Generated by Obstacles Around a Cooling Tower (냉각탑 주위 장애물에 의한 재순환 현상에 관한 3차원 수치해석)

  • Choi, Young-Ki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.4
    • /
    • pp.225-234
    • /
    • 2009
  • The present study has been preformed to investigate the effect of obstacles around a cooling tower with air-guide to prevent recirculation. The external region as well as the cooling tower are included in the computational domain to analyze the flow phenomena around a cooling tower accurately. Three-dimensional analysis is performed using the finite volume method with non-orthogonal and unstructured grid system. The standard turbulence model is used to consider the turbulence effect. In order to investigate the recirculation phenomena, flow and temperature fields are calculated with the distance between cooling tower and obstacle, the allocated geometrical type and the air-guide. The moisture fraction rates decrease with increment of the distance between cooling tower and obstacle. The effect of air-guide to reduce the mean recirculation rate is obviously observed.

Drawing of Twenty Kinds of State and Process on Psychrometric Chart (습공기선도 상에 20 종류의 상태 및 과정 값의 작도)

  • Kim, Deok-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1201-1206
    • /
    • 2008
  • Psychrometric chart displays graphically the thermophysical properties of moist air, so it is very conveniently used in air-conditioning and refrigeration. On general psychrometric chart, there are dry bulb temperature, web bulb temperature, absolute humidity ratio, relative humidity, specific enthalpy, specific volume, sensible heat factor, and enthalpy-humidity difference ratio. However, various state and process values besides aboves can be plotted on psychrometric chart. In this study, we developed the software drawing twenty kinds of lines, that is vapor pressure, mole fraction ratio of vapor, dew point temperature, degree of saturation, density, specific entropy, specific exergy, contact or bypass factor, uncomfort index, discomposition index, predicted mean vote index, predicted percent dissatisfied, and so on. We wish to this software is a help to design, analysis and education.

  • PDF

Evaluation of Void Content in Carbon Fiber/Epoxy Composites Manufactured by Different Manufacturing Process (제작공법을 달리한 탄소섬유/에폭시 복합재의 기공함유율 평가 기법)

  • Yoona, Sungho;Jang, Jungkeun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.2
    • /
    • pp.32-40
    • /
    • 2017
  • In this study, the procedures for quantitative measurement of void contents of carbon fiber/epoxy composites were suggested. Two types of the composites were considered: autoclave cured composite and filament wound composite. Void contents of the composites were evaluated by the density of the composites and their constituents, which was determined from weights in the air and water, and the weight fraction and volume fraction of the constituents obtained from the digestion method and combustion method. The surfaces of filtered carbon fibers were examined by FE-SEM in order to investigate the validity of resin removal from the composites. According to the results, the resin in the composites could be fully removed by the digestion method and combustion method. Therefore, the weight fraction and volume fraction of the constituents, and void content of the composites could be quantitatively obtained by the suggested procedures.

The Formation and Transition of 2212 and 2223 Phase in BPSCCO System (BPSCCO System에서 2212 및 2223 phase의 생성.전이)

  • Park, Y.P.;Wang, J.B.;Kim, H.C.;Kim, W.G.;Lee, J.U.
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.311-315
    • /
    • 1991
  • The formation and transition of 2212 and 2223 phase have been studied in BPSCCO system. The 2212 phase formed in early sintering state reacts on $Ca_2PbO_4,\;Ca_2CuO_3$ and CuO during sintering process and thus produces the 2223 phase. A long sintering period is need to fabricate the superconductor with large volume fraction of 2223 phase. Also, the thin plate-like grains composed of Bi, Sr, Ca and Cu contribute to 2223 phase formation. Though the sample has lower volume fraction of 2223 phase, the critical temperature is measured highly in case of the grain grown to plate-like shape. In this work, the critical temperature of the sample sintered for 264 hr in air was measured 108 K. Microstructure of the sample was varied with condition of heat treatment after sintering process and the sample annealed with $500^{\circ}C$ for 5 hr showed excellent charateristics of 2223 phase formation.

  • PDF

Squeeze Casting of SiC Whisker Reinforced Magnesium Composites (용탕단조를 이용한 SiC 휘스카 강화 마그네슘복합재료의 제조)

  • Chang, Si-Young;Shin, Dong-Hyuk;Hong, Sung-Kil;Choi, Jung-Chul
    • Journal of Korea Foundry Society
    • /
    • v.20 no.3
    • /
    • pp.167-172
    • /
    • 2000
  • Squeeze casting was performed to fabricate the SiC whisker reinforced magnesium matrix composites, and the suitability of the squeeze casting for the production of the sound composites was determined by micro/macro-structures observations and tensile test. The two-directional infiltration of the melt and the removal of air during infiltration using the devised mold were necessary to produce the composites. The pressure of 100 MPa was effective for the production of composites with the SiC whisker volume fraction of 30%, but the pressure should be lower than 50 MPa in case of below 20% in the volume fraction. The SiC whiskers in the squeeze cast composites were randomly and densely aligned, and the SiC whiskers/magnesium interfaces were continuously well-bonded. The elastic modulus, 0.2% proof stress and tensile strength in the composite were about 2.5times, l0times and 4times as large as those of magnesium, respectively, indicating that the squeeze casting sufficiently provides the high strength magnesium composites reinforced with SiC whiskers.

  • PDF

Oxygen Transfer and Hydraulic Characteristics in Bubble Column Bioreactor Applied Fine Bubble Air Diffusing System (미세기포 산기장치를 적용한 타워형 생물반응기의 산소전달 및 수력학적 특성)

  • Lee, Seung-Jin;Ko, Kyeong-Han;Ko, Myeong-Han;Yang, Jae-Kyeong;Kim, Yong-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.11
    • /
    • pp.772-779
    • /
    • 2012
  • For improving performance of conical air diffuser generating fine bubble, both experimental and numerical simulation method were used. After adapting diffusers inner real scale bubble column, suitable for various diffuser submergence, the effect of diffuser submergence on oxygen transfer performance such as Oxygen Transfer Coefficient ($K_{L}a_{20}$) and Standard Oxygen Transfer Efficiency (SOTE) was investigated empirically. As flow patterns for various diffuser number and submergence were revealed throughout hydrodynamic simulation for 2-phase fluid flow of air-water, the cause of the change for oxygen transfer performance was cleared up. As results of experimental performance, $K_{L}a_{20}$ was increased slightly by 7% and SOTE was increased drastically by 39~72%, 5.6% per meter. As results of numerical analysis, air volume fraction, air and water velocity in bioreactor were increased with analogous flow tendency by increasing diffuser number. As diffuser submergence increased, air volume fraction, air and water velocity were decreased slightly. Because circulative co-flow is determinant factor for bubble diffusion and rising velocity, excessive circulation intensity can result to worsen oxygen transfer by shortening bubble retention time and amount.

OH Radical Distribution and Sooting Characteristics in Co-Flow Diffusion Flames (동축류 확산화염의 OH 라다칼 분포 및 매연 특성)

  • Lee, Won-Nam;Song, Young-Hoon;Cha, Min-Suk
    • 한국연소학회:학술대회논문집
    • /
    • 1997.06a
    • /
    • pp.1-11
    • /
    • 1997
  • The soot and OH radical distributions have been experimentally studied in ethylene and propane laminar diffusion flames. The integrated soot volume fraction was measured along the centerline of a flame using a laser light extinction method. Planar laser light scattering and PLIF techniques are employed for the soot and OH radical distribution measurements utilizing Nd:YAG laser and OPO, FDO system. The concentration of OH radical is rapidly decreased at the edge of sooting region, which implies the importance of OH radical species on the soot oxidation process. For ethylene flames, the addition of air in fuel moves the OH radical distribution towards the center line of a flame at the soot oxidation region, while the concentration of OH radical remains relatively high at the soot formation region. The interaction between soot particles and OH radicals becomes more active with fuel-air at the soot oxidation region. For propane flames, however, any indication of the increased interaction between soot particles and OH radicals with fuel-air was not noticed.

  • PDF

Soot Formation in a Double-Concentric Diffusion Flame (동축 이중 확산화염의 매연 생성 특성)

  • Jurng, Jongsoo;Lee, Gyo-Woo;Ko, Bum-Seung;Kang, Kyung-tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1355-1362
    • /
    • 1999
  • An experimental study on a double-concentric diffusion flame(DDF) has been carried on in order to Investigate the characteristics of soot formation compared to a normal coflow diffusion flame(NDF). Laser extinction technique has been used for an ethylene($C_2H_4$) and air flame with various flow rates. Soot formation In the double-concentric diffusion flame was enhanced by the inner inverse diffusion flame due to the increase in flame temperature and also suppressed due to the nitrogen-dilution from the inner air. Soot concentration at the flame axis of DDF was higher than that of the NDF, mainly because of the increase of temperature by inner flame. However, the maximum soot volume fraction of DDF was lower than NDF at the outer side of the flame, mainly due to the effect of nitrogen-dilution from the inner air.