• Title/Summary/Keyword: Air volume

Search Result 2,288, Processing Time 0.033 seconds

Comparison of the Performance of the VAV Dampers for the Circular Duct (원형 덕트용 VAV 댐퍼의 성능 비교)

  • Kwon, Young-Pil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.9
    • /
    • pp.699-703
    • /
    • 2012
  • The performance of the typical VAV dampers; blade type, venturi type and blade-orifice type, for the circular duct, is obtained by measuring the volume flow rate as a function of the opening degree. The performance features are discussed by comparing the volume flow rate of each damper. It is shown that the blade-orifice type damper, recently developed, is excellent in its linearity of the performance and that it is worse than the blade type but much better than the venturi type in its flow resistance.

Numerical study on Comparison of Self-Pressurization Behavior of Liquid Nitrogen Cryostat for Umbilical Cord Blood Storage System Design

  • Mahfud, M.I.;Phil, K.E.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.409-414
    • /
    • 2009
  • Since cryogens are stored at very low temperatures, the cryogenic storage systems are quite sensitive to heat leaks. Even though the vessel operated under sealed condition with vacuum insulation and reflective coatings are used, the heat leakage into the vessel is still unavoidable. Therefore, this paper concerns with numerical study of self-pressurization used to analysis the optimum design with the variation volume fraction, effect of heat flux and storage pressure of liquid nitrogen. The result shows that as the volume fraction increases, the pressure rise reduces and the relatively at atmosphere pressure is better than the higher one. In addition, higher heat flux leads the pressure rise increases faster than low one. The additional of heat pipe system to reduce the pressure rise rate also has been done. By this comparison, the optimum design for storage umbilical cord blood can be selected.

  • PDF

Flame Propagation Characteristics of Propane-Air Premixed Mixtures (프로판-공기 예혼합기의 화염전파 과정에 관한 연구)

  • Bae, Choong-Sik
    • Journal of the Korean Society of Combustion
    • /
    • v.1 no.2
    • /
    • pp.21-29
    • /
    • 1996
  • Flame propagation characteristics of propane-air mixtures were experimentally investigated in constant-volume combustion chambers. Flame propagation process was observed as a function of mixture strength, initial mixture temperature and initial mixture pressure in quiescent mixtures. A cylindrical combustion chamber and a spherical combustion chamber contain a pair of parallel windows through which optical access into the chamber can be provided. Laser two beam deflection method was adopted to measure the local flame propagation, which gave information on the flame size and flame propagation speed. Pressure development was also measured by a piezoelectric pressure transducer to characterize combustion in quiescent mixtures. Burning velocity was calculated from flame propagation and pressure measurements. The effect of flow on flame propagation was also investigated under flowing mixture conditions. Laser two beam method was found to be feasible in measuring flame propagation of quiescent mixtures. Flame was observed to propagate faster with higher initial mixture temperature and lower initial pressure. Combustion duration was shortened in the highly turbulent flowing mixtures.

  • PDF

Development of Freeze Drying Analysis Program using Fixed Grid (고정격자를 이용한 동결건조 해석프로그램의 개발)

  • Nam Jin Hyun;Song Chi Sung;Kim Charn-Jung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.923-931
    • /
    • 2004
  • A multi-dimensional freeze drying analysis program, which took simultaneous heat and mass transfer, sublimation of ice and motion of sublimation front into full account, was developed using finite volume method with fixed grid. The effect due to the motion of sublimation interface was modeled by an enthalpy formulation streamlined for the freeze drying problems. The efficiency and accuracy of the program was validated by solving one- and two-dimensional freeze drying problems frequently encountered in industrial processes. Finally, the freeze drying processes of cylinder and slab objects with permeable side surfaces were simulated, which demonstrated the capability of the present analysis program in solving multi-dimensional freeze drying problems with complex sublimation interface configurations.

The Analysis of Optimum Design Parameters for a Solar Space Heating System through Computer Simulation (시뮬레이션에 의한 태양열 난방의 최적설계에 관한 연구)

  • Seoh, Jeong-Il;Lee, Young-Soo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.3
    • /
    • pp.175-186
    • /
    • 1985
  • This paper presents a method for estimating the useful output of solar space heating system and estimates their performance with variance of collector size, storage volume, collector tilt and other factors . The analysis is performed by the computer simulation and by 'running' conceptual systems against solar intensities and ambient temperature for a model year stored in a computer. System performance is analyzed on monthly and yearly basis respectively and at the same time, the economics of various systems are evaluated . And also, this paper shows how an optimized design can be selected for any locality for which solar data, economic parameters and system performance are provided. It is shown that storage volume of 75 liter per $m^2$ of solar collector lead to the best design.

  • PDF

An Analysis of the Air Void Volume Image Analysis of Porous Cement Mortar Composites (Image analysis를 통한 다공성 시멘트 모르타르 복합체 내 공극량 산출)

  • Son, Dasom;Yi, Chong ku
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.211-212
    • /
    • 2021
  • This study was conducted to derive quantitative air void volume calculation techniques in various complexes with porosity. Calculation of voids in a complex is an essential factor in improving mechanical properties, and quantitative measurement techniques are needed because the environment is not constant to apply the currently used ASTM criteria. Using the analysis technique obtained through 2D image analysis, it is believed that meaningful results can be derived through Micro CT analysis results and cross-check later.

  • PDF

Experimental Study on the Effect of the Amount of Acrylic Viscosity Agent on the Physical Properties of High-Fluidity Concrete using Low-Binder (아크릴계 증점제 사용량이 저분체 고유동 콘크리트의 물리적 특성에 미치는 영향에 관한 실험적 연구)

  • Ko, Hye-Bin;Kong, Tae-Woong;Cho, In-Sung;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.72-73
    • /
    • 2021
  • For the development of high-fluidity concrete using low-binder, The effect of the use of the developed acrylic viscosity agent on the physical properties of concrete evaluated. The amount acrylic viscosity agent used was 1.5%, 1.7%, and 2.0% based on the binder amount of 400kg/m3, and slump flow test, slump flow 500mm arrival time measurement, air volume measurement, and U-Box passing test were conducted to determine the effect of the physical properties of concrete. it was judged that 1.5% of the acrylic viscosity agent used in high-fluidity concrete using low-binder was most suitable.

  • PDF

Experimental Study on the Effect of the Amount of Cellulose type Viscosity Agent on the Physical Properties of High-Fluidity Concrete Using Low-Binder (셀룰로스계 증점제의 첨가량이 고유동 저분체 콘크리트의 물리적 특성에 미치는 영향에 관한 실험적 연구)

  • Ko, Hye-Bin;Cho, In-Sung;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.129-130
    • /
    • 2021
  • For the development of high-fluidity concrete using low-binder, The effect of the use of the developed acrylic viscosity agent on the physical properties of concrete evaluated. The amount acrylic viscosity agent used was 0.28%, 0.29% and 0.30% based on the binder amount of 350kg/m3, and slump flow test, air volume measurement, U-Box passing test and strength compressive were conducted to determine the effect of the physical properties of concrete. it was judged that 0.29% of the cellulose type viscosity agent used in high-fluidity concrete using low-binder was most suitable.

  • PDF

Transport Spillover Effect on Airport Networks and Its Impact on Regional Economy (운송 파급효과가 항공네트워크와 지역경제에 미치는 영향)

  • Xinchen Wang;Po-Lin Lai
    • Korea Trade Review
    • /
    • v.47 no.4
    • /
    • pp.35-52
    • /
    • 2022
  • Air transport is at the core of global economic growth. There is a close relationship between the flow of regional elements and the growth of the regional economy. It is easy to misestimate the impact of airports on the regional economy without considering spatial spillover effects. This study attempted to establish an asymmetric economic geographical weight matrix by applying the Spatial Durbin Model with cargo volume and passenger numbers as indicators. The influence of spillover effects on the regional economy, including direct spillover effects and indirect spillover effects are studied. The results revealed that passenger numbers and cargo volume have significant positive spillover effects on the regional economy. The driving effect of the airport on the regional economy was considered from a wider space scope. This study contributes to the scientific evaluation of the aviation economy.

A Study on Fine Dust Prediction Based on Internal Factors Using Machine Learning (머신러닝을 활용한 내부 발생 요인 기반의 미세먼지 예측에 관한 연구)

  • Yong-Joon KIM;Min-Soo KANG
    • Journal of Korea Artificial Intelligence Association
    • /
    • v.1 no.2
    • /
    • pp.15-20
    • /
    • 2023
  • This study aims to enhance the accuracy of fine dust predictions by analyzing various factors within the local environment, in addition to atmospheric conditions. In the atmospheric environment, meteorological and air pollution data were utilized, and additional factors contributing to fine dust generation within the region, such as traffic volume and electricity transaction data, were sequentially incorporated for analysis. XGBoost, Random Forest, and ANN (Artificial Neural Network) were employed for the analysis. As variables were added, all algorithms demonstrated improved performance. Particularly noteworthy was the Artificial Neural Network, which, when using atmospheric conditions as a variable, resulted in an MAE of 6.25. Upon the addition of traffic volume, the MAE decreased to 5.49, and further inclusion of power transaction data led to a notable improvement, resulting in an MAE of 4.61. This research provides valuable insights for proactive measures against air pollution by predicting future fine dust levels.