• 제목/요약/키워드: Air ventilation

검색결과 1,570건 처리시간 0.033초

도시형 한옥의 안마당 사용실태에 관한 기초적 조사 -서울 북촌마을을 중심으로- (A Study on a Application of the Inner Court in Urban Traditional Housing - Focused on the Bukchon Village, Seoul -)

  • 박현옥;김현아;백혜선;이상미
    • 한국디지털건축인테리어학회논문집
    • /
    • 제6권2호
    • /
    • pp.39-46
    • /
    • 2006
  • "Urban traditional housing" means a type of urban housing which retains characteristics of traditional Korean houses for ordinary people. It is a form of housing created in the process in which traditional Korean ways of life are applied to swift modernization. In Korea's traditional housing, the "court" functioned as a living space that promoted family bonding. The space of the court still remains in the urban traditional housing. However, rapid popularization of the westernized housing form, i.e., apartments, resulted in standardization and westernization of our housing and living patterns, and as a result, the court in urban traditional housing came to lose its original meaning. The objects of this study are residents of urban traditional housing. By studying them, this research aims, firstly, to understand the meaning of the inner court, secondly to analyze correlation between the residents' consciousness of the inner court and their use of the space, and ultimately to find various possible forms of our future housing. For this research, twenty six houses in the Gahoe-dong area in which urban traditional houses are densely built up were investigated. According to the result of this research, the inner court in current urban traditional housing is a space existing inside a house but directly exposed to outer air at the same time. It is a private but shared space. It contributes to forming a pleasant atmosphere by facilitating ventilation and providing sunlight. In addition, it is a living space that actively reflects the Korean living style that values family life.

  • PDF

주거복지지표 개발에 관한 연구 II - 수요자 측면의 주거복지체감지표와 지수를 중심으로 - (Development of the Sentiment Indicators of Housing Welfare)

  • 지은영;은난순;홍형옥
    • 한국주거학회논문집
    • /
    • 제19권5호
    • /
    • pp.85-92
    • /
    • 2008
  • The aim of this research is to develop the sentiment indicators of housing welfare for evaluating housing welfare policies conducted by the Korean government. The methods of this research are used by analysis of related documents, FGI (Focus Group Interview), and survey. The survey was made by experts and consumers. To analyze the survey, this research also uses confirmatory factor analysis by SPSS (Statistical Package for the Social Science) program, AHP (Analytical Hierarchy Process) by Expert Choice program, frequency, average, percentages, Factor analysis etc. As a result of this research, selected housing welfare indicators are settled as follows: In the housing welfare aspect, 11 indicators in the department of 'Housing Satisfaction' and 11 indicators in the department of 'Community Satisfaction' (22 in total) are suggested. The indicators are 1) Water Supply and Distribution Equipment 2) Heating equipment 3) the size of the exclusive residential area 4) the number of rooms 5) Ventilation and Lighting 6) Sound Insulation (Indoor Noise) 7) Air Pollution/Odor 8) House Deposit 9) Rent Paid 10) Maintenance (Dwelling) Cost 11) The length of Occupation 12) Proximity to Welfare Facilities 13) Educational Environment 14) Convenience of Facilities (shops, hospitals etc.) 15) Convenience of Transportation and Commuting 16) Distance from Workplace 17) Landscape and Green Space (Tree, Flowers, Grass etc.) 18) Vandalism (Destruction Behavior, graffiti etc.) 19) Privacy 20) Noise in Public Places (Drinking, Loudly Talking etc.) 21) Safety from Crime 22) Safety from a Disaster. As of 2007, the housing welfare sentiment index is measured by the survey of 1,000 inhabitants in the public housing, which shows 3.51.

감염 예방을 위한 인공신장실 의료 환경에 대한 고찰 - 근거 기반의 디자인 중심으로 (A Review of Renal Dialysis Unit Environment for Infection Prevention - Focused on Evidence Based Design)

  • 한수하;윤형진
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제24권3호
    • /
    • pp.49-57
    • /
    • 2018
  • Purpose: The increase in patients requiring hemodialysis has resulted in an increase dialysis-associated infections risk. but there are no Renal Dialysis unit design standard meet specified safety and quality standards. Therefore, appropriate Establish standards and legal regulation is important for the provision of initial certification and maintenance of facility, equipment, and human resource quality. Methods: Literature survey on the design guideline and standards of Renal Dialysis unit design in Korea, U.S, Germany, Singapore, Hongkong, Dubai. Results: There are no established standards for facilities in dialysis units in Korea. To prevent infections in dialysis patients, necessary establish standards. Considering the domestic and overseas Health-care facilities standards, the major factors to be considered in the medical environment for Renal Dialysis Unit are as follows. First, planning to separate Clean areas(treatment area) from contaminated areas(medical waste storage area). Second, ensure sufficient space and minimum separation distance. Although there may be differences depending on the circumstances of individual institutions, renal dialysis unit consider the space to prevent droplet transmission. Third, secure infrastructure of infection prevention such as sufficient amount of hand hygiene sinks. Hand washing facilities for staff within the Unit should be readily available. Hand hygiene sinks should be located to prevent water from splashing into the treatment area. Fourth, Heating, ventilation and air conditioning (HVAC) system for Renal Dialysis Unit is all about providing a safer environment for patients and staff. Implications: The results of this paper can be the basic data for the design of the Renal Dialysis Units and relevant regulations.

화재안전성을 위한 도시철도 차량의 구조개선 (A Study on the Structural Reform of Urban Transit Vehicle Considering Elevation of Fire Safety)

  • 이근오;김규중
    • 한국안전학회지
    • /
    • 제21권5호
    • /
    • pp.22-27
    • /
    • 2006
  • Even though the interior of urban transit vehicle has been changed as a preventing measure against fire to make it inflammable, there remains a possibility of fire breaking out in case of gasoline etc being brought in the subway. However, there is also the possibility that in case if fire toxic gas is generated and hot air spreads in carriage it will prove very dangerous for people sitting inside. This is a comparative study where we compare simulation results with model examining the time and direction the fire spreads when it breaks out. Also there is vertical distribution of temperature in carriage where the fire spreads out. This study is about demonstrating how to establish smokeless system in urban vehicle, about its necessity, and about vehicle system restructuring. This study also makes an effort to find more advanced method for efficient fire safety in trains. In existing vehicles, in case of fire, the smoke can't go out when doors are closed and hence it spreads in whole train. Even though the method of using ventilation or exhaust established inside the carriage to throw smoke out is much better than the way of opening end doors in each carriage, this study is trying to do research on second way. Through simulation we see that in second case, even though not as good as the first one, smoke can exit through gates. Even though the first method is better, the second can also be uses to let fire out. We can know that in the first case as the smoke can exit out faster, it provides more safety for people. So this system provides better fire safety condition.

서울지역 라돈농도의 분포예측을 위한 공간분석법 연구 (Studies on the Spatial Analysis for Distribution Estimation of Radon Concentration at the Seoul Area)

  • 백승아;이태정;김신도;김동술
    • 한국대기환경학회지
    • /
    • 제24권5호
    • /
    • pp.538-550
    • /
    • 2008
  • Radon is an invisible, odorless, and radioactive gas. It is formed by the disintegration of radium, which is a decay product of uranium. Some amounts of radon gas and its products are present ubiquitously in the soil, water, and air. Particularly high radon levels occur in regions of high uranium content. Although radon is permeable into indoor environment not only through geological features (bed rock and permeability) but also through the construction materials and underground water, the radiation from the geological features is generally main exposure factor. So there can be a problem in a certain space such as the underground and/or relatively poor ventilation condition. In this study, a GIS technique was used in order to investigate spatial distribution of radon measured from sub- way stations of 1 thru 8 in Seoul, Korea in 1991, 1998, 2001, and 2006. Spatial analysis was applied to reproduce the radon distribution. We utilized spatial analysis techniques such as inverse distance weighted averaging (IDW) and kriging techniques which are widely used to relate between different spatial points. To validate the results from the analyses, the jackknife technique for an uncertainty test was performed. When the number of measuring sites was less than 100 and also when the number of omitted sites increased, the kriging technique was better than IDW. On the other hand, when the number of sites was over 100, IDW technique was better than kriging technique. Thus the selection of analytical tool was affected sensitives by the analysis based on the number of measuring sites.

전문가와 거주자 인식 관점에서 본 한옥의 특성과 적용 (The Characteristics and Applications of Han-Ok in the Perception of their Residents and Experts)

  • 이민아
    • 한국생활과학회지
    • /
    • 제20권2호
    • /
    • pp.487-503
    • /
    • 2011
  • The purpose of this study was to investigate residents' perceptions and attitudes towards Han-Ok based on a study of the characteristics and elements of Han-Ok that experts perceived. For the study, in-depth interviews were conducted and the data of 7 experts and 24 Han-Ok residents were analyzed. The results of the study were as follows. First, the characteristics of spatial arrangements are primarily emphasized and provide emotional stability for the residents. Placement on the ground, a suitable scale, appropriate openings and closures, hierarchical spatial system and a spatial relationship provide a feeling of comfort and protection. Second, the spaces and the materials of Han-Ok are considered the representative elements providing functionality and health. The close relationship between the inside and outside area makes the air naturally circulate and natural materials such as wood, soil, and paper have the function as natural ventilation, heat storage, and in the prevention of various illnesses. Third, residents in modern society put more of a value on experiences of natural environments that are usually impossible in the city. The simple and incomplete characteristics in using color, materials, and form, provide a culture of story telling and a leisurely lifestyle. Fourth, the cold and spatial inconvenience of Han-Ok are solved by partially using modernized equipment and material. The functionality of spatial systems in Han-Ok needs to be promoted in order to change the residents' perceptions of cold in Han-Ok.

흉추 추간판 탈출증에서 흉강경하 흉추간판 절제술 (Thoracoscopic Discectomy of the Herniated Thoracic Discs)

  • 이상호;임상락;이호연;전상협;한영미;정병주
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권12호
    • /
    • pp.1577-1583
    • /
    • 2000
  • Objectives : Among the various types of minimally invasive spine surgeries, thoracoscopic surgery is becoming more widely accepted and increasingly utilized. This report delineates our clinical experience using thoracoscopy to resect herniated thoracic discs in 16 patients who suffered from myelopathy or intolerable radiculopathy. Patients and Methods : Between Mar. 1997 and Sep. 1999, 16 consecutive patients underwent thoracoscopic discectomy for treatment of herniated thoracic discs. There were 12 men and 4 women(mean age 43.5 years ; range 18-61 years). Eleven patients presented with myelopathic signs and symptoms from spinal cord compression and 5 patients had incapacitating thoracic radicular pain without myelopathy. The surgical level was varied between T3 and T12. The pathology of specimen were 11 hard discs and 5 soft discs herniations. Thoracoscopic techniques were performed with long narrow spine instruments and high speed drill through 3 or 4 ports under one lung ventilated general anesthesia. During the operation three patients were converted to open thoracotomy due to intolerable one lung ventilation, excessive bleeding and inadequate operation field. The mean operation time was 264min.(range : 100-420min.), and postoperative mean admission period was 11 days. Results : Clinical and neurological outcomes were good in all patients(mean follow-up period 20 months). Among the eleven myelopathic patients, 8 improved neurologically, and 3 stabilized. Among the five radiculopathic patients, 4 recovered completely and no patient had worsened. Postoperative complications were pleural effusion in one case, intercostal neuralgia in one, delayed hemopneumothorax in one, prolonged air leakage in one and pneumonia in one case. Conclusions : Thoracoscopic discectomy needs a steep learning curve to be familiar to anatomical space and handling of endoscopic instruments. However, it is technically feasible and can be effectively performed with acceptable results.

  • PDF

빌딩 에너지 절감 밸브용 제어 및 감시 보드 개발 (Development of control and monitoring board for building energy saving valve)

  • 오진석;강영민;장재희
    • 한국정보통신학회논문지
    • /
    • 제22권6호
    • /
    • pp.895-902
    • /
    • 2018
  • 건물에 의한 에너지 소비량은 미국 및 일본 등 선진국에서는 전체 국가 에너지 소비량의 40%에 육박하고 있으며, 우리나라에서도 전체 에너지 소비량의 24%를 차지하고 있는 것으로 보고되고 있다. 빌딩에서 HVAC (Heating, Ventilation, and Air conditioning)은 필요 열량에 따라 냉각 유량을 자유롭게 제어할 수 없기 때문에 에너지가 효율적으로 사용되지 않고 있다. 따라서 에너지 절감 밸브를 사용함으로써 유량을 필요한 열량만큼 제어하여 에너지를 절감할 수 있다. 본 논문에서는 에너지 절감 밸브를 개발하기 위한 기본적인 상태를 정의하고 저전력, 고 가성비의 PIC 프로세서 기반의 빌딩 에너지 절감 밸브용 제어 및 감시 보드를 개발한다. 설계된 보드는 온도차 측정을 위한 2개의 온도 값과 유량 값 및 계산된 열량에 관한 정보를 실시간으로 디스플레이 및 전송한다. 개발된 제어 감시 보드는 향후 밸브의 상태를 실시간으로 파악하거나 해상용 밸브 등을 개발하는 데 유용하게 사용될 것이다.

풍동장치를 이용한 열선풍소계의 보정 및 실태 평가 (Calibration and Performance Test of Hot-wire Anemometers by Using a Calibration Wind Tunnel)

  • 하현철;김태형;김은아;김종철;오정룡;정호근
    • 한국산업보건학회지
    • /
    • 제9권2호
    • /
    • pp.110-122
    • /
    • 1999
  • Hot-wire anemometers are most commonly used in measuring hood capture velocities due to their accuracy and convenience. But it was questionable that the anemometers being used in the field are accurate enough for the purpose of measurements. To answer this ques tion, a calibration wind tunnel was newly devised and tested. Subsequently, 53 hot-wire anemometers being currently used in the field were tested to evaluate the accuracy of anemometers. The average error was 16.93% while the average errors in the low (0.5~5m/s) and high (5~20m/s) velocity range were 17.40% and 16.45%, respectively. Most of anemometers underestimated the true velocities. It might be due to the contamination of hot-wire, resulting in the slow heat transfer between the sensor and air flow. Astonishingly, 16 of 53 anemometers were out of order due to the malfunctioning of zero adjustment control, power supply, display panel and sensor. It is desirable to calibrate periodically and clean the sensor after using in the dirty environment.

  • PDF

소형 직화식 커피 로스터 이용 시 발생하는 미세먼지 특성 연구 (Characteristics of Particulate Matter Generated during the Operation of a Small Directly Fired Coffee Roaster)

  • 유다은;김승원
    • 한국산업보건학회지
    • /
    • 제30권2호
    • /
    • pp.236-248
    • /
    • 2020
  • Objectives: The purpose of this study was to evaluate the concentrations of particulate matter generated during coffee roasting and to study various factors affecting the concentrations. Methods: Differences in concentration levels were investigated based on various factors to understand the emission rates of particulate matter over time and to compare the mass and number concentrations according to their size. Sampling was performed in closed laboratories without the operation of air conditioning or ventilation. Optical Particle Sizer(OPS) was used as a measuring device. An OPS measures using a light-scattering method. Sampling was performed for sixty minutes at one-minute intervals. The background concentration was measured for about 30 minutes before starting of coffee roasting. The concentrations of particulate matter generated during coffee roasting were monitored until roasted coffee beans were removed from the roaster and cooled down. Several factors affecting the concentrations of particulate matter were investigated, which includes the origins of green beans, the roasting level, and the input amount of green beans. Results: The results of this study may be summarized as follows: 1) There was no difference in particulate matter concentration levels by the origin of the green beans, but a statistically significant difference in concentration levels by roasting level and the input amount of green beans; The higher the roasting level, the higher was the particulate matter concentration. The more green beans we put in the roaster, the higher were the concentrations; 2) The PM10 mass concentrations increased over time. The average concentration after roasting was higher than the average concentration during roasting; 3) In the distribution of mass and number concentration by particle diameter, the majority of particles was below 2.5 ㎛. Conclusions: Persons who work in roastery cafes can be exposed to high concentrations of particulate matter. Therefore, personal exposure and risk assessment should be conducted for roastery cafe workers.