• Title/Summary/Keyword: Air source

Search Result 2,261, Processing Time 0.034 seconds

A Discovery System of Malicious Javascript URLs hidden in Web Source Code Files

  • Park, Hweerang;Cho, Sang-Il;Park, Jungkyu;Cho, Youngho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.5
    • /
    • pp.27-33
    • /
    • 2019
  • One of serious security threats is a botnet-based attack. A botnet in general consists of numerous bots, which are computing devices with networking function, such as personal computers, smartphones, or tiny IoT sensor devices compromised by malicious codes or attackers. Such botnets can launch various serious cyber-attacks like DDoS attacks, propagating mal-wares, and spreading spam e-mails over the network. To establish a botnet, attackers usually inject malicious URLs into web source codes stealthily by using data hiding methods like Javascript obfuscation techniques to avoid being discovered by traditional security systems such as Firewall, IPS(Intrusion Prevention System) or IDS(Intrusion Detection System). Meanwhile, it is non-trivial work in practice for software developers to manually find such malicious URLs which are hidden in numerous web source codes stored in web servers. In this paper, we propose a security defense system to discover such suspicious, malicious URLs hidden in web source codes, and present experiment results that show its discovery performance. In particular, based on our experiment results, our proposed system discovered 100% of URLs hidden by Javascript encoding obfuscation within sample web source files.

The Development of Air-kerma Strength Calculation Algorithm in Terms of the Absorbed Dose to Water for HDR Ir-192 Source (기준점에서의 물 흡수선량을 이용한 Ir-192 선원의 공기커마 세기 계산을 위한 알고리즘 개발)

  • Huh, Hyun-Do;Kim, Woo-Chul;Loh, John-Jk;Lee, Suk;Lee, Sang-Hoon;Cho, Sam-Ju;Shin, Dong-Oh;Choi, Jin-Ho;Kwon, Soo-Il;Kim, Seong-Hoon
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.232-237
    • /
    • 2006
  • The aim of this study was to develop the calculation algorithm of source strength of Ir-192 source In terms of the absorbed dose to water instead of an apparent activity (Ci). For this work the Multi Purpose Brachytherapy Phantom(MPBP) was developed, which was designed to locate the source and the chamber precisely at a specific position Inside the water phantom. The reference point of measurement was set at the 5 cm distance along the transverse axis of the source. For a brachytherapy source calibration, the absorbed dose to water calibration factor ($N_{D.W.Q}$) of an lonization chamber were determined and then apply standard protocols of absorbed dose to water. The calibration factor ($N_{D.W.Q}$) of the ion chamber (TM30013, PTW, Germany) was determined using the EGSnrcCPP Monte Carlo Code. The calculated calibration factor ($N_{D.W.Q}$) was 5.28 cGy/nC. The calculated factor was then used to determine the absorbed dose to water from which the air kerma strength for an Ir-192 source can be easily derived at the reference point (5 cm). The calculated air kerma strength showed discrepancies of -0.6% to +1.8% relative to the air kerma strength provided by the vendor, In this work we demonstrated that the air kerma strength ($S_k$) could be determined from the absorbed dose to water calibration factor for Ir-192 source. In audition, this source calibration method could be applied directly to the dose Calculation formalism of AAPM report TG-43.

  • PDF

Identification of Potential Source Locations of PM2.5 in Seoul using Hybrid-receptor Models (하이브리드 수용모델을 이용한 서울시 PM2.5 오염원의 위치 추적)

  • Kang, Byung-Wook;Kang, Choong-Min;Lee, Hak-Sung;SunWoo, Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.6
    • /
    • pp.662-673
    • /
    • 2008
  • Two hybrid receptor models, potential source contribution function (PSCF) and concentration weighted tracjectory (CWT), were compared for locating $PM_{2.5}$ sources contributing to the atmospheric $PM_{2.5}$ concentrations in Seoul. The source contribution estimates by chemical receptor model (CMB) receptor model were used to identify better source areas, Among the sources, soil, agricultural burning, marine aerosol, coal-fired power plant and Chinese aerosol were only considered for the study because these sources were more likely to be associated with the long-range transport of air pollutant. Both methods are based on combining chemical data with calculated air parcel backward trajectories. However, the PSCF analyses were performed with trajectories above the $75^{th}$ percentile criterion values, while the CWT analyses used all trajectories. This difference resulted in locating of different sources, which might be helpful to interpret locating of $PM_{2.5}$ sources, High possible source areas in source contribution of soil and agricultural burning contributing to the Seoul $PM_{2.5}$ were inland areas of Heibei and Shandong provinces (highest density areas of agricultural production and population) in China. The "Chinese aerosol" was used as a representative source for the $PM_{2.5}$ originated from urban area in China. High possible source areas for the aerosol were the cities in China where are relatively close to the receptor. This result suggests that Chinese aerosol is likely to be a useful tool in studies on source apportionment and identification in Korea.

Measurement of VOCs Concentrations at Jeonju Industrial Area and Emission Characteristics (전주공단지역의 주요VOCs 배출농도 측정 및 배출원별 특성 분석)

  • Kim, Deug-Soo;Yang, Go-Soo;Park, Bi-O
    • Journal of Environmental Science International
    • /
    • v.16 no.3
    • /
    • pp.299-310
    • /
    • 2007
  • It will be necessary to make proper management plans to preserve the air quality in good level for the public. In order to make these plans, source information and detail emission inventories of the city and near industrial areas should be given. However, lack of the source measurements data makes us more difficult to complete the source inventory. VOC source Inventory could be utilized for the feasibility study to estimate the contribution of VOC sources presenting to the receptor such as residential area. It may give policy maker an idea how to control the air quality, and improve their social environment in the area. This study shows data that measured VOCs concentrations from the local industrial areas in Jeonju during from May 2005 to January 2006. The samples were collected from the near sources in 7 major factories in the industrial park as well as 5 general sources in near city Jeonju area to elucidate the abundances of speciated VOCs and their spacial and temporal distributions depending on source bases. Industrial sources are as follows; chemical, food, paper, wood, metal, non-metal (glass), and painting (coating) industries. The 5 general sources are sampled from tunnel, gasoline gas station, dry cleaning shop, printing (copy) shop, and road pavement working place in urban area. To understand the near source effect at receptor, samples from the 2 receptor sites (one is at center of the industrial complex and the other site is at distance residential area downwind from the center) were collected and analyzed for the comparison to source concentration. The mass contributions of the speciated VOC to total mass of VOCs measured from the different sources and ambient (2 receptors) were presented and discussed.

A Study on Hybrid Heating System with Anti-Superheating Devices (과열방지장치가 설치된 복합열원 난방시스템에 관한 연구)

  • Park, Youn-Cheol;Ko, Gwang-Soo;Han, Yu-Ry
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.19-27
    • /
    • 2007
  • The previous study was conducted to develop an air source multi heat pump system that could be operated with the solar collector and air source heat exchangers as heat source of the system. There is a winter-sowing problems in air source multi heat pump system when the outdoor temperature goes down under freezing point. The winter-sowing problem was solved by adapting R-22 refrigerant as working fluid in the previous study. However, when the system operated at high temperature, another problems are come out such as overheating of the solar collector outlet which lead to the superheat of the compressor inlet of the heat pump system. The condition could deteriorates a compressor in some case. In this study, we installed the anti-superheating devices on the previously developed system. As results of system performance test, COP of the system with anti-superheating technique is 2.4. It is a little improved COP compare to previous study's 2.23. In the results of multi heat source heating system, during operating solar collector, COP is relatively high between $200\;W/m^2$ and $400\;W/m^2$ solar intensity. It is recommended to extend the study on performance optimization with balancing the solar collect and capacity of compressor at higher solar irradiation conditions.

Dose Characteristics by the Co-60 Source Oscillations in High Dose Rate After Loading Irradiations (고선량율 원격강내조사의 코발트-60 이동선원에 의한 선량특성)

  • 최태진;김옥배;노홍균
    • Progress in Medical Physics
    • /
    • v.1 no.1
    • /
    • pp.51-60
    • /
    • 1990
  • Dose distributions around Co- 60 moving source in high dose rate remote afterloading unit, Buchler 3K unit, were experimented with X-omat V films and calculations. In our experiments, film dosimetries have achieved to evaluated the axial dose distributions for source oscillations were 0, 3.5, 5.0 and 6.0 cm in periodically, In results, the dose distributions in axial of source movement showed apparently higher than in transverse direction caused by source locations, dwelling time and air gap in the applicator. In the calculations, the dose rate was derived by using the inverse square law, filteration corrections and Meisberger constant for scatter corrections as source movings. In our experiments and calculations, the average dose uncertainties were showed -2.1$\pm$1.9% in fixed sourdce, -2.9$\pm$1.8%, -7.4$\pm$6.1% and -6.7$\pm$4.6% at 3.5 cm, 5.0 cm and 6.0 cm source oscillations, but the calculations have showed very close to experimental dose rate within 4 cm distance from source.

  • PDF

Determination of Source Contribution Based on Aerosol Number and Mass Concentration in the Seoul Subway Stations (분진의 개수농도 및 질량농도에 입각한 서울시 지하철 역사 내 오염원의 기여도 결정)

  • 최형욱;황인조;김신도;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.1
    • /
    • pp.17-31
    • /
    • 2004
  • The subway play an important part in serious traffic problems. However, because subway system is a closed environment, many serious air pollution problems occurred in subway stations and injured passenger's health. Therefor, it is a necessary to identify sources and to estimate pollutant sources in order to protect passenger's health and to keep clean subway environment. The purpose of this study was to analyze a air quality in the subway stations and to apply a new receptor methodology for quantitatively estimate of PM10 sources. In this study, the size distributions of particulate matters has been measured by using Aerosizer LD (U.S.A., API, Inc.). It's real time measurement capability of time-of-flight technique offers a significant advantage of user convenience and air pollution management. Also, the mass concentrations of PM 10 has been measured by using mini-vol portable sampler (U.S.A., Airmetrics Co.). The sampling performed in Seoul subway stations during the period of February 2000 and April 2000. The number distribution data used in this study consisted of 26 raw data sets in the Jongno-sam-ga station. Correlation Analysis can be used in subway stations for source separation and identification. Then, number contribution from each source is determined by the particle number balance (PNB). The mass concentration data used in this study consisted of 31 raw data in the 8 different stations. The mass contributions of PM10 sources in the concourse by using PMF/CMB model.

Application study of heat storage type GSHP system in Apartment building with central cooling and heating facilities using life cycle cost analysis (LCC 분석을 이용한 중앙공급식 공동주택의 수축열식 지열원 히트펌프시스템의 적용연구)

  • Lee, Sang-Hoon;Park, Jong-Woo;Cho, Sung-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1497-1502
    • /
    • 2009
  • The present study has been conducted economic analysis of heat storage type ground source heat pump system(HSGSHP) and normal ground source heat pump (GSHP) and central boiler system with individual air conditioning facility which are installed at the same building in the shared an apartment house. Cost items, such as initial construction cost, annual energy cost and maintenance cost of each system are considered to analyze life cycle cost (LCC) and simple payback period (SPP) with initial cost different are compared. The initial cost is a rule to the Government basic unit cost of production. LCC applied present value method is used to assess economical profit of both of them. Variables used to LCC analysis are prices escalation rate and interest rate mean values of during latest 10 years. The LCC result shows that HSGSHP (1,351,000,000won) is more profitable than central boiler system with individual air conditioning facility by 86.7% initial cost. And SPP appeared 8.0 year overcome the different initial cost by different annual energy cost.

  • PDF

A study on power source characteristic of a dust collector for power factor compensating (역률보상형 전기집진기 전원장치 특성연구)

  • Lee, Dong-Gil;Hong, Ji-Tae;Kim, Ho-Sung;Son, Min-Kyu;Lee, Kyoung-Jun;Kim, Jong-Rak;Kim, Hee-Jea
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1326-1327
    • /
    • 2008
  • Recently, the air pollution is supposed is to be the most serious environmental problem. Therefore, a small air cleaner is asked to make comfortable indoor environment for the moderns who have frequent indoor activity. In this study, without generating of the second pollution source, dust in the air and harmful microorganisms can be removed by the electric dust collecting technology which has high reliability and efficiency to be able to remove the impurities even though it is just 0.01${\mu}m$. Accordingly, power sources of the dust collector use, it is not inefficiency and offering to dust collector unstable. In order to overcome the point at issue, a this study, for power factor compensating use the PFC circuit, for removing the noise use EMI filter and for generating the hight voltage use the Cockcroft Walton Circuit. And we study power source on characteristic and improvement.

  • PDF

Distribution and emission source of PAHs in ambient air of Seoul (서울지역 대기 중의 PAHs 분포 특성 및 발생원)

  • Park, Jin-Soo;Yoon, Seong-Kyu;Bae, Woo-Keun
    • Analytical Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.269-277
    • /
    • 2010
  • Air samples were collected and analyzed to investigate regional level of PAHs and its emission sources. The average concentrations of PAHs in the suburban (Gwanak) and in the urban (Seodaemun) area were $16.52\;ng/m^3$ and $59.1\;ng/m^3$, respectively. Phenanthrene, fluoranthene, pyrene, and fluorene were predominant PAHs species, as their sum contributed to 55.6% and 60.8% of the total PAHs, respectively. The possible major source of PAHs was suspect to be the combustion of diesel fueled vehicles in both areas, particularly for Seodaemun.