• Title/Summary/Keyword: Air source

Search Result 2,258, Processing Time 0.027 seconds

Identifying Ambient PM2.5 Sources and Estimating their Contributions by Using PMF : Separation of Gasoline and Diesel Automobile Sources by Analyzing ECs and OCs (PMF 모델을 이용한 미세분진의 오염원 확인과 기여도 추정 : 탄소성분을 이용한 휘발유 및 경유차량 오염원의 분리)

  • Lee, Hyung-Woo;Lee, Tae-Jung;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.1
    • /
    • pp.75-89
    • /
    • 2009
  • The purpose of this study was to identify $PM_{2.5}$ sources and to estimate their contributions to the border of Yongin-Suwon area, based on the analysis of the $PM_{2.5}$ mass concentration and the associated inorganic elements, ions and carbon components. The contribution of $PM_{2.5}$ sources were estimated by using a positive matrix factorization (PMF) model to identify air emission sources. For this study, $PM_{2.5}$ samples were collected from May, 2007 to April, 2008. The inorganic elements were analyzed by an ICP-AES. The ionic components in $PM_{2.5}$ were analyzed by an Ie. The carbon components were also analyzed by DRI/OGC analyzer. After performing PMF modeling, a total of 12 sources were identified and their contributions were quantitatively estimated. The contributions from each emission source were as follows: 11.3% from oil combustion source, 3.4% from bus/highway source, 5.8% from diesel vehicle source, 4.7% from gasoline vehicle source, 8.8% from biomass burning source, 15.1 % from secondary sulfate, 5.2% from secondary nitrate source, 13.4% from industrial related source, 4.1% from Cl-rich source, 19.6% from soil related source, 1.0% from aged sea salt, and 7.4% from coal combustion source, respectively. This study provides basic information on the major sources affecting air quality, and then it will help to effectively control $PM_{2.5}$ in this study area.

Performance of Heat Pump System Using Underground Air as Heat Source (지하공기를 이용하는 농업시설용 난방시스템)

  • Kang, Youn-Ku;Ryou, Young-Sun;Kim, Young-Hwa;Sung, Moon-Seok;Kim, Jong-Koo;Jang, Jae-Kyoung;Lee, Hyoung-Mo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.587-589
    • /
    • 2009
  • The districts of underground geologic structure in Jeju island where underground air is distributed are lava cave, pyroclastic, open joint, and crushing zone. Such districts are identified to secure an enough airflow when air ventilation layer is to secure 25-35m in depth. In Jeju, Ground air is used for heating greenhouse and fertilizing natural $CO_2$ gas by suppling directly into greenhouse. But the heating method by suppling ground air into greenhouse directly bring about several problem. The occurrence of disease of the crops by high humidity is worried because the underground air which becomes discharge from underground air layer has over 90% relative humidity. The underground air is inadequate in heating for crops which need high temperature heating such as mangos, Hallbong and mandarin orange because the temperature of it is $15{\sim}18^{\circ}C$. Also There is worry where the ventilation loss becomes larger because the air pressure inside greenhouse is high by supplying underground air directly. In this study the heat pump system using underground air as heat source was developed and heating performance of the system was analysed. Heating COP of the system was 2.5~5.0 and rejecting heat into greenhouse and extracting heat from underground air were 40,000~27,000 kcal/h, 30,000~18,000 kcal/h respectively.

  • PDF

Modeling and Analysis of Leakage Currents in PWM-VSI-Fed PMSM Drives for Air-Conditioners with High Accuracy and within a Wide Frequency Range

  • Sun, Kai;Lu, Yangjun;Xing, Yan;Huang, Lipei
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.970-981
    • /
    • 2016
  • Leakage currents occur in pulse-width-modulated voltage source inverter (PWM-VSI)-fed permanent magnet synchronous motor (PMSM) drives for air-conditioners, which seriously affect system safety and operation performance. High accuracy modeling and prediction of leakage currents are key issues for the design and implementation of air-conditioning products. In this study, the generation mechanism of leakage currents is discussed. A systematic modeling approach of leakage currents is proposed, including the modeling of leakage current sources and leakage current paths. By using the proposed approach, the complete model of leakage currents in PWM-VSI-fed PMSM drives for air-conditioners has been developed based on the extraction of all parameters. A comparison between the simulated leakage currents based on the developed model and measured leakage currents in the outdoor unit of an air-conditioning product is conducted. The comparison verifies the effectiveness of the proposed modeling approach, and the developed model exhibits high accuracy within a wide frequency range.

Properties and classification of air discharge by Kohonen network (기중방전의 특성분석과 Kohonen network에 의한 방전원의 패턴분류)

  • 강성화;박영국;이광우;김완수;이용희;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.704-707
    • /
    • 1999
  • Partial discharge(PD) in air insulated electric power systems is responsible for considerable power lossesfrom high voltage transmission lines. PD in air often leads to deterioration of insulation by the combined action of the discharge ions bombarding the surface and the action of chemical compounds that are formed by the discharge and may give rise to interference in ommunication systems. PD can indicate incipient failure. Thus understanding and classification of PD in air is very important to discern source of PD. In this paper, we investigated PD in air by using statical method. We classified air discharge with corona, surface discharge and cavity discharge by source of discharge. we used the mean pulse-height phase distribution $H_{qmean}(\psi)$, the max pulse-height phase distribution $H_{qmax}(\psi)$ , the pulse count phase distribution $H_n(\psi)$ and the max pulse height vs. repetition rate $H_{q}(n)$ for analysis PD pattern. We used statistical operators, such as skewness(S+. S-1, kurtosis(K+, K-), mean phase(AP+. AP-), cross-correlation factor(CC) and asymmetry from the distribution.

  • PDF

Chemical Characteristics and Source Apportionment ofPM2.5 in Seoul Metropolitan Area in 2010 (2010년도 서울시 대기 중 PM2.5의 성분특성 및 발생원 추정에 관한 연구)

  • Moon, Kwang-Joo;Park, Seung-Myung;Park, Jong-Sung;Song, In-Ho;Jang, Sung-Ki;Kim, Jong-Chun;Lee, Seok-Jo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.6
    • /
    • pp.711-722
    • /
    • 2011
  • This study is aimed to estimate the $PM_{2.5}$ source apportionment at Seoul intensive monitoring site located in Seoul metropolitan area. Time-resolved chemical compositions of $PM_{2.5}$ are measured in real time using ambient ion monitor, semi-continuous carbon monitor, and on-line XRF at Seoul intensive monitoring site in 2010. The mass concentration of $PM_{2.5}$ was simultaneously monitored with eight ionic species (${SO_4}^{2-}$, $NO_3{^-}$, $Cl^-$, $NH_4{^+}$, $Na^+$, $K^+$, $Mg^{2+}$, $Ca^{2+}$), two carbonaceous species (OC and EC), and fourteen elements (Si, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Zn, As, Se, Pb) in 1-hr interval. The data sets were then analyzed using EPA PMF version 3 to identify sources and contributions to $PM_{2.5}$ mass. EPA PMF modeling identified eight PM2.5 sources, including soil dust, secondary sulfate, secondary nitrate, motor vehicle, coal combustion, oil combustion, biomass burning, and municipal incineration. This study found that the average $PM_{2.5}$ mass was apportioned to anthropogenic sources such as motor vehicle, fuel combustion, and biomass burning (61%) and secondary aerosols, including sulfate and nitrate (38%).

Statistical Analysis for Chemical Characterization of Fall-Out Particles (강하분진의 화학적 특성파악을 위한 통계학적 해석)

  • Kim, Hyeon-Seop;Heo, Jeong-Suk;Kim, Dong-Sul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.6
    • /
    • pp.631-642
    • /
    • 1998
  • Fall-out particles were collected by the modified British deposit gauges at 35 sampling sites in Suwon area from January to November, 1996. Twenty chemical species (Al. Ba, Cd, Cr, K, Pb, Sb, Zn, Cu, Fe, Ni, V, F-, Cl-, NO3-, 5042-, Na+, NH4+, Mg2+, and Ca2+) were analyzed by AAS and If. The purposes of this study were to estimate qualitatively various emission sources of the fell-out particle by applying multivariate statistical techniques such as factor analysis, multiple regression analysis, and discriminant analysis. During the study, outlier sites were determined by a z-score method. Cl-, Na+, Mg2+, and SO42- were highly correlated due to their common marine related source. Wind speed was the most influential factor for the deposition fluxes of the particle itself and all the chemical species as well. When applying the factor analysis, 8 source patterns were qualitatively obtained, such as marine source, soil source, oil burning source, Cr related source, tire source, Cd related source, agriculture source, and F- related source. As a result of the multiple regression analysis, we could suggest that some chemical compounds may possibly exist in the form of CaSO4, NaN03, NaCl, MgC12, (NH4)2SO4, NaF, and CaCl2 in the fall-out particles. Finally, spatial and seasonal classification study performed by a discriminant analysis showed th.at SO42-, Ca2+, Cl-, and Fe were dominant in the group of spatial pattern; however, SO42-, Cl-, Al, and V were in the group of seasonal pattern.

  • PDF

A Numerical Simulation of Air Pollutant Concentration Considering Land and Sea Breeze in Ulsan Area (해륙풍을 고려한 울산지역 대기오염물질농도의 수치모의)

  • 이화운;원경미;정우식;오은주;김민선;도우곤
    • Journal of Environmental Science International
    • /
    • v.11 no.9
    • /
    • pp.933-943
    • /
    • 2002
  • The urban pollution if affected by local environmental, so it is necessary to consider area characteristics such as emission source and meteorological phenomena, in studying urban air pollution. Ulsan is laocated on south-east coast and has many industrial facilities, so many people have concerned about air pollution. This study contain conducting numerical simulation of air pollutant concentration considered land and sea breeze in Ulsan area with the numerical model.

A Numerical Study of the Backdraft Behavior with the Variation of the Ignition Location and Time (점화원 위치 및 점화시간 변화에 따른 백드래프트 거동에 관한 수치적 연구)

  • Ko, Min Wook;Oh, Chang Bo;Han, Yong Shik;Do, Kyu Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.1-8
    • /
    • 2016
  • The behavior of backdraft in the compartment with different ignition locations and times was numerically investigated. The Fire Dynamics Simulator (FDS) v5.5.3 with a model-free simulation option was used in the numerical simulation of backdraft. The ignition source was located near the inside wall, at the compartment center and near the window opening, respectively. The ignition was started at the instance when the fresh air reached the ignition location or when a sufficient time passed compare to the instance of the arriving of the fresh air to the ignition location. As a result, for the ignition source was located near the inside wall, a strong fire ball was observed at once and the result was similar to the previous experimental result. For the ignition source was located at the center of the compartment, a strong fire ball was occurred and two strong fire balls were observed consecutively for the ignition time was delayed. For the ignition source was located near the window opening and longer time was given for the ignition compare the duration of the fresh air arriving to the ignition location, the rapid temperature variation was not observed because there was no flame. However, for the ignition was started at the instance when the fresh air reached the ignition location, the ignition could be initiated and a intensive fire ball was observed. The pressure measured at the upper inside part of the window opening provided a similar trend with the previous experimental result of compartment backdraft.

Noise Source Identification of a Pulse Combustion Burner Using Digital Signal Processing Techniques (디지탈 신호처리 기법을 이용한 맥동연소기의 소음원 규명에 관한 연구)

  • Kim, D.W.;Cho, J.G.;Lee, K.S.;Oh, J.E.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.2
    • /
    • pp.103-113
    • /
    • 1991
  • This paper presents a method for estimating the noise source contribution of a pulse combustion burner in a multiple input system where the input sources may be coherent each other. By coherence function method, it is found that the biggest part of the noise source in the pulse combustion burner is generated by the part of the combustion chamber. This analysis is modeled as three input / single output system because the noise generating mechanism of the pulse combustion burner is very complicated. The coherence function method is proved to be useful tool for the identification of noise source. The overall levels of the radiated source pressure by coherence function method are compared with those measured and calculated by the frequency response function approach. The experimental results have shown a good agreement with the results calculated by the coherence function method when the input sources are coherent strongly each other. The estimation of shield effect by FRF method indicates that significant reduction can be achieved in sound radiation if only transmission path generated by the part of combustion chamber is acoustically shield.

  • PDF

A Discovery System of Malicious Javascript URLs hidden in Web Source Code Files

  • Park, Hweerang;Cho, Sang-Il;Park, Jungkyu;Cho, Youngho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.5
    • /
    • pp.27-33
    • /
    • 2019
  • One of serious security threats is a botnet-based attack. A botnet in general consists of numerous bots, which are computing devices with networking function, such as personal computers, smartphones, or tiny IoT sensor devices compromised by malicious codes or attackers. Such botnets can launch various serious cyber-attacks like DDoS attacks, propagating mal-wares, and spreading spam e-mails over the network. To establish a botnet, attackers usually inject malicious URLs into web source codes stealthily by using data hiding methods like Javascript obfuscation techniques to avoid being discovered by traditional security systems such as Firewall, IPS(Intrusion Prevention System) or IDS(Intrusion Detection System). Meanwhile, it is non-trivial work in practice for software developers to manually find such malicious URLs which are hidden in numerous web source codes stored in web servers. In this paper, we propose a security defense system to discover such suspicious, malicious URLs hidden in web source codes, and present experiment results that show its discovery performance. In particular, based on our experiment results, our proposed system discovered 100% of URLs hidden by Javascript encoding obfuscation within sample web source files.