• Title/Summary/Keyword: Air separation unit

Search Result 62, Processing Time 0.027 seconds

A Study on the Development for a Cryogenic Air Separation Unit (심랭식 공기분리장치 개발 연구)

  • 문흥만
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.132-135
    • /
    • 2001
  • Cryogenic air separation unit(ASU) was developed about 100 year ago in Europe. However, because there is not any ability of process design or manufacturing of ASU in Korea, many ASUs come from advanced countries every year. The purpose of this study is the development of cryogenic air separation unit by our own ability, especially cold box for nitrogen production. On this study, we developed the computer program for physical properties of gases and process simulation. We also did process design and manufactured of cold box, including air separation column, liquid air heat exchanger and condenser. The result of cold box test was successful.

  • PDF

The Effect of the Integration Methods of Gas Turbine and Air Separation Unit on IGCC Plant Performance (가스터빈과 산소분리공정의 연계 방법에 따른 IGCC 플랜트 성능영향 분석)

  • 서석빈;김종진;조상기;이윤경;안달홍
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.533-539
    • /
    • 1999
  • Integration methods of a Gas Turbine and a Air Separation Unit have a potential to improve plant performance and cost of IFCC. Several studies on those integrations schemes were carried out. Then some of the methods were accually in commercial plants. Thus paper reviewed the integration schemes of a Gas Turbine and a Air Separation Unit. In order to compare the plant performance of IGCC with each scheme, simulation model was developed for IGCC power cycle with Texaco Quench gasification process. The simulation results showed that the thermal efficiency of the plant was appeared to be the best when all of the air consumption required for Air Separation Unit was supplied from the Gas Turbine and the net plant power output was maximized when 75% of the total ASU an requirement was supplied from Gas Turbine.

  • PDF

Thermodynamic Performance Evaluation of an Integration Design between the Combined-cycle and Air Separation Unit in an IGCC Power Plant (IGCC 발전 플랜트에서 복합발전공정-공기분리장치의 연계에 관한 열역학적 성능 평가)

  • Won, On Nu-ri;Kim, Hyun-jeong;Park, Sung-koo;Na, Jong-moon;Choi, Gyung-min;Kim, Duck-jool
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.49-51
    • /
    • 2012
  • In this paper, the integration issue, such as an air-side integration design between the gas turbine and air separation unit, is described and analyzed by the exergy and energy balance of the combined-cycle power block in an IGCC power plant. The results showed that the net power of the system was almost same, but that of the gas turbine was decreased as the integration degree increased. The highest exergy loss was occurred in the combustor of gas turbine, which was affected by the chemical reaction, heat conduction, mass diffusion, and viscous dissipation.

  • PDF

Overall Performance characteristic for 300MW Taean IGCC Plant (300MW 태안 IGCC 플랜트 종합성능 특성)

  • Kim, Hakyong;Kim, Jaehwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.129.2-129.2
    • /
    • 2010
  • As a part of the government renewable energy policy, KOWEPO is constructing 300MW IGCC plant in Taean. IGCC plant consists of gasification block, air separation unit and power block, which performance test is separately conducted. Overall performance test for IGCC plant is peformed to comply with ASME PTC 46. Major factors affected on the overall efficiency for IGCC plant are external conditions, each block performance(gasification, ASU, power block), water/steam integration and air integration. Performance parameters of IGCC plant are cold gas efficiency, oxygen consumption, sensible heat recovery of syngas cooler for gasification block and purity of oxygen, flow amount of oxygen and nitrogen, power consumption for air separation unit and steam/water integration among the each block. The gas turbine capacity applied to the IGCC plant is 20 percent higher than NGCC gas turbine due to the low caloric heating value of syngas, therefor it is possible to utilize air integration between gas turbine and air separation unit to improve overall efficiency of the IGCC plant and there is a little impact on the ambient condition. It is very important to optimize the air integration design with consideration to the optimized integration ratio and the reliable operation. Optimized steam/water integration between power block and gasification block can improve overall efficiency of IGCC plant where the optimized heat recovery from gasification block should be considered. Finally, It is possibile to achieve the target efficiency above 42 percent(HHV, Net) for 300MW Taean IGCC plant by optimized design and integration.

  • PDF

A Study on the Utilization of the LNG Cold Heat for the Reduction of the Power Consumption in Main Air Compressors in Cryogenic Air Separation (심냉 공기분리공정의 공기압축공정에서 전력비 절감을 위한 액화천연가스 냉열 활용에 대한 연구)

  • CHO, DUHEE;CHO, JUNGHO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.3
    • /
    • pp.322-327
    • /
    • 2020
  • In this work, a study for the reduction of the electric power consumption has been estimated in main air compressors in the air separation unit through cryogenic distillation columns with PRO/II with PROVISION V10.2 at AVEVA company. Both required LNG mass flow rate and cold heat contained in 1 ton of LNG were also predicted using Peng-Robinson equation of state with Twu's new alpha function. Through this work, we concluded that 32.33-48.69% of electric power could be saved by using LNG cold heat.

A Study on the Development of a Cryogenic Air Separation Unit to Produce High Purity Nitrogen (고순도 질소생산용 초저온 공기분리장치 개발 연구)

  • 용평순;문흥만;이성철
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.69-73
    • /
    • 2001
  • For developing the cryogenic air separation unit, it requires some technology such as basic process design. equipment design and manufacturing based on the cryogenic physical properties and separation theory. In this study, we developed a process and equipment for producing high purity nitrogen which has the production capacity of 1600N㎥/h under 1 ppm $O_2$ and $H_2O$. Also we found that the number of theoretical plate(NTP) of distillation column was 44 and maximum nitrogen recovery ration of this process was 42% from the process simulation. The performance test was also carried out for the nitrogen recovery ratio and equipment efficiency. The results showed that the optimum nitrogen recovery was 41% and the maximum equipment efficiency was attained.

  • PDF

Simulation and Sensitivity Analysis of the Air Separation Unit for SNG Production Relative to Air Boosting Ratios (SNG 생산용 공기분리공정의 공기 재 압축비에 따른 민감도 분석)

  • Kim, Mi-yeong;Joo, Yong-Jin;Seo, Dong Kyun;Shin, Jugon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.3
    • /
    • pp.173-179
    • /
    • 2019
  • Cryogenic air separation unit produces various gases such as $N_2$, $O_2$, and Ar by liquefying air. The process also varies with diverse production conditions. The one for SNG production among them has lower efficiency compared to other air separation unit because it requires ultrapure $O_2$ with purity not lower than 99.5%. Among factors that reduce the efficiency of air separation unit, power consumption due to compress air and heat duty of double column were representatives. In this study, simulation of the air separation unit for SNG production was carry out by using ASEPN PLUS. In the results of the simulation, 18.21 kg/s of at least 99.5% pure $O_2$ was produced and 33.26 MW of power was consumed. To improve the energy efficiency of air separation unit for SNG production, the sensitivity analysis for power consumption, purities and flow rate of $N_2$, $O_2$ production in the air separation unit was performed by change of air boosting ratios. The simulated model has three types of air with different pressure levels and two air boosting ratio. The air boosting ratio means flow rate ratio of air by recompressing in the process. As increasing the first air boosting ratio, $N_2$ flow rate which has purity of 99.9 mol% over increase and $O_2$ flow rate and purity decrease. As increasing the second air boosting ratio, $N_2$ flow rate which has purity of 99.9 mol% over decreases and $O_2$ flow rate increases but the purity of $O_2$ decreases. In addition, power consumption of compressing to increase in the two cases but results of heat duty in double column were different. The heat duty in double column decreases as increasing the first air boosting ratio but increases as increasing the second air boosting ratio. According to the results of the sensitivity analysis, the optimum air boosting ratios were 0.48 and 0.50 respectively and after adjusting the air boosting ratios, power consumption decreased by approximately 7% from $0.51kWh/O_2kg$ to $0.47kWh/O_2kg$.

Pneumatic Separation on Separating Unit of a Combine Harvester (콤바인 선별실(選別室)의 기류선별(氣流選別)에 관한 연구(硏究))

  • Chung, C.J.;Nam, S.I.;Joo, B.C.
    • Journal of Biosystems Engineering
    • /
    • v.13 no.3
    • /
    • pp.32-43
    • /
    • 1988
  • This study was attempted to investigate the pneumatic separation on separating unit of a combine harvester. The aerodynamic characteristics of threshed materials were analyzed by experiments. The air velocity distribution within the separation chamber was measured for various speeds of the winnower and suction fans to find out the operational and design conditions of the separating unit which would serve for reducing the grain loss from chaff outlet. The results of study arc summarized as follows: 1. Based on the separation curve of threshed materials analyzed, it was shown that three different kind. of materials-kernels, straw chaff, and leaf chaff were as a whole able to be separated pneumatically, regardless of varieties. However, a small amount of the separation grain loss may be expected to occur if the complete separation between kernels and straw chaff would be undertaken because some portion of their separation curve were overlapping. 2. The analysis of air velocity distribution showed that the separation chamber may be divided into two regions, the discharging and separating. The air velocity of the discharging region was 5-15 m/s and that of the separating region 2-5 m/s. 3. The air movement of the separation chamber may be a turbulence flow, being its speed became greater as it moves from the left to the right section of the separation chamber. The equi-speed line. of air flow had a steep gradient in between the discharging and the separation regions. The air velocity in the discharging region was much higher than the terminal velocity of kernels, because of which those kernels appearing in the region could be possibly exhausted as the grain loss from the chaff outlet. 4. The motion trajectory of threshed material in the separating region was dominantly affected by the winnower fan, on the other hand, its motion in the discharging region was affected by suction fan. 5. The grain loss from the chaff outlet was affected greatly by the winnower fan and the trace of kernel movement. It was observed that the optimum working speed to give minimum grain loss from chaff outlet for the combine tested should be maintained at 950~1,150 rpm for the winnower fan and 1,850 rpm for the suction fan. 6. It was shown that a large portion of grain loss from chaff outlet may occur when the kernels may bump against a portion of separation chamber wall and those kernels thus scattered into the discharging region were sucked by the suction fan. It was accordingly recommended that a new design of the wall of separation chamber so as to bump down kernels may be necessary to reduce grain loss from the chaff outlet.

  • PDF

Process Analysis and Simulation for System of Air Liquefaction Separation Using LNG Cold Energy (LNG 냉열을 이용한 공기액화분리시스템의 시뮬레이션 및 공정 해석)

  • HAN, DANBEE;BAEK, YOUNGSOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.3
    • /
    • pp.276-281
    • /
    • 2019
  • The process of separating oxygen and nitrogen from the air is mainly performed by electric liquefaction, which consumes a lot of electricity, resulting in higher operating costs. On the other hand, when used for cold energy of LNG, electric power can be reduced compared to the electric Linde cycle. Currently, LNG cold energy is used in the cold refrigeration warehouse, separation of air-liquefaction, and LNG cold energy generation in Japan. In this study, the system using LNG cold energy and the Linde cycle process system were simulated by PRO/II simulators, respectively, to cool the elevated air temperature from the compressor to about $-183^{\circ}C$ in the air liquefaction separation process. The required amount of electricity was compared with the latent heat utilization fraction of LNG, the LNG supply pressure, and the LNG cold energy usage. At the air flow rate of $17,600m^3/h$, the power source unit of the Linde cycle system was $0.77kWh/m^3$, compared with $0.3kWh/m^3$.

Flotation Characteristics of Activated Sludge by Micro-bubbles (미세 기포에 의한 활성슬러지의 부상특성)

  • Kim, Seong-Jin;Kang, Byoung-Jun;Park, Sang-Wook;Lee, Jae-Wook;Jung, Heung-Joe;Kwak, Dong-Heui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.4
    • /
    • pp.501-507
    • /
    • 2006
  • Dissolved air flotation (DAF) has been well known for the gravity separation process. The solids to be separated are transferred from the water body to the water surface using micro-air bubbles. DAF has also been used for enhancing solids-liquid separation of industrial and municipal wastewater by adding a its unit parallel to a sedimentation unit to reduce the hydraulic loading in the sedimentation clarifier. This study was to investigate flotation characteristics of activated sludge by the recent DAF technique without chemical agents. In addition, the effect on temperature in flotation of activated sludge and the thickening degree of activated sludge were studied.