• Title/Summary/Keyword: Air pressure variation

Search Result 375, Processing Time 0.027 seconds

The Influence of Long-range Transport on Springtime Nocturnal Ozone Enhancement in Seoul (봄철 서울지역 야간 오존농도 상승에 미치는 장거리 수송의 영향)

  • 오인보;김유근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.4
    • /
    • pp.503-514
    • /
    • 2004
  • In Seoul metropolitan area, nocturnal variation of surface ozone concentrations observed at 27 monitoring sites from 1998 to 2002 showed that high ozone levels occurred frequently during the spring. Frequency distributions for nighttime ozone indicated that elevated concentrations in spring were influenced by advection of different air mass compared to other seasons. Surface wind analysis during the spring revealed that relatively strong southwesterly winds were associated with nocturnal ozone enhancement, which can be attributed to the regional transport of ozone. In order to identify the origin of nocturnal ozone enhancement in spring, 3-day backward trajectories were calculated by HYSPLIT 4 for the episode days and then classified. The results showed that NW, W, and SW flows, indicating influence of polluted air masses from the China continent, have 51% in a]1 the episode days, which suggest that the nocturnal ozone enhancement can occur under the effect of long-range transport of ozone-laden air mass on a regional scale. Case study of nocturnal ozone maxima associated with long-range transport was discussed in more detail in the light of meteorological conditions. Southwesterly synoptic flow along the outer edge of moving high-pressure system was found to be the important cause of nocturnal ozone maxima in Seoul. This flow could lead to be long-range transport of ozone that had effectively accumulated in the stagnating portion of the system located eastern coast of China. Low atmosphere soundings, backward trajectories, and elevated ozone and CO levels at the back-ground tiles gave evidence for regional effects on nocturnal ozone enhancement In Seoul.

Flow Measurements at the Exit of a Throttle Valve in Gasoline Engines (가솔린 엔진의 스로틀 밸브 출구에서 유동측정)

  • Kim, Sung-Cho;Kim, Cheol;Choi, Jong-Geon;Wee, Hwa-Bok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.2
    • /
    • pp.1-8
    • /
    • 2002
  • The flow and combustion patterns have been investigated inside the gasoline engine cylinder with the swirl or tumble flow, whereas the air flow characteristics, which are generated in the part of intake system before entering into the intake manifold, have not been known completely. It is necessary to analyze the flow field in the intake system consisting of air rater, throttle valve and intake manifold. The throttle valve, used to control the intake air flow rate, is important because it makes various mass flow rate and flow patterns. Three-dimen-sional How characteristics such as velocities, turbulent intensities and Reynolds shear stresses are measured by the hot wire anemometer at the exit of the throttle valve with the variation in the valve opening angle($15^{\circ}$, $45^{\circ}$, $75^{\circ}$ and $90^{\circ}$) and the Reynolds numbers (45000, 70000 and 140000). There are a lot of changes in flow characteristics at $75^{\circ}$ due to the large recirculation flow comparing with those of the other cases, and the streamwise velocity is especially enforced strongly below the valve shaft. The other component velocities are relatively large near the centerline parallel to the valve shaft. The effects of the Reynolds number on the flow field are not severe.

Analysis of Flow and Heat Transfer in Swirl Chamber for Cooling in Hot Section (고온부 냉각을 위한 스월챔버내의 유동 및 열전달 해석)

  • Lee Kang-Yeop;Kim Hyung-Mo;Han Yeoung-Min;Lee Soo-Yong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.05a
    • /
    • pp.71-78
    • /
    • 2002
  • All modem, aerospace gas turbines must operate with hot stage gas temperature several hundreds of degrees hotter than the melting temperatures of the materials used in their construction. Complicated cooling schemes need to be employed in the combustor walls and In the high pressure turbine stages. Internal passages are cast or machined into the hot sections of aero-gas turbine engines and air from the compressor is used for cooling. In many cases, the cooling system is engineered to utilize jets of high velocity air, which impinge on the internal surfaces of the components. They are divided by Impinging cooling method and Vortex cooling method. Specially, Research of new cooling system(Vortex cooling method) that overcome inefficiency of film cooling and limitation of space. The focus of new cooling system that improve greatly cooling efficiency using quantity's cooling air which is less is set in surface heat transfer elevation. Therefore, In this study, the numerical analysis have been performed for characteristic of flow and thermal in the swirl chamber and compared with the flow field measurement by LDV. especially, for understanding of high heat transfer efficiency in vicinity of wall. we considered flow structure and mechanism of vortex and heat transfer characteristic in variation of Reynolds number.

  • PDF

Characteristics of Pd-MIS devices on hydrogen gas sensing (Pd-MIS 소자의 수소가스 검지 특성)

  • Yi, Cheal W.;Cha, Won I.;Shin, Chee B.;Yun, Kyung S.;Ju, Jeh B.
    • Journal of Hydrogen and New Energy
    • /
    • v.3 no.2
    • /
    • pp.17-24
    • /
    • 1992
  • Hydrogen gas sensors were fabricated after the form of metal/insulator/semiconductor(MIS) structure on a p-type silicon wafer and a insulating layer (silicon dioxide) thickness was changed from $500{\AA}$ to $5000{\AA}$. Their electrical properties were investigated with the variation of the hydrogen gas concentration at room temperature. At the applied forward bias of lV to both ends of Pd-MIS sensors the current was decreased logarithmically with the increase of hydrogen concentration in air. In the case of a thin $SiO_2$ layered ($500{\AA}$) sensor the current ratio was decreased to 25 % at 1 % of hydrogen concentration in air and 50% for a thick $SiO_2$ layered ($5000{\AA}$) sensor. And the response time of the thick insulating layered sensor to 1% hydrogen containing air was about 50 seconds and regeneration time was 2.5 minutes. When a 0.5mA current was appied to the thick insulating layered sensor the maximun voltage shift was calculated to 0.8V in the case of ${\theta}$ = 1 and the Pd surface coverage of hydrogen was increased logarithmically with hydrogen partial pressure.

  • PDF

A Study on the Drying Performance of the Flux Adhered to Photovoltaic Ribbon (플럭스가 점착된 솔라 리본 건조 연구)

  • Cho, Nam-Cheol;Jeon, Young-Han;Han, Sang-Pil;Kim, Dong-Choon;Lee, Chae-Moon;Jeon, Taeg-Jong
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • The photovoltaic ribbon attached the flux reduces the solar module manufacturing process and the pollution. This paper presents an analytical method for solving the continuous flux drying system of photovoltaic ribbon. Also, some experiments of the drying of photovoltaic ribbon are carried out in order to design the drying system. Numerical results indicate the air temperature, the air velocity, the air pressure and the timewise temperature variation of ribbon during drying process. In case of the drier process length is short, 400mm, the photovoltaic ribbon is wet. Thus, another study of drying system is necessary to improve the drying ability. As a result, multi-stage drier system is proposed and shown to be good drying ability.

Decadal Changes in the Relationship between Arctic Oscillation and Surface Air Temperature over Korea (북극진동과 한반도 지표기온 관계의 장기변동성)

  • Jun, Ye-Jun;Song, Kanghyun;Son, Seok-Woo
    • Atmosphere
    • /
    • v.31 no.1
    • /
    • pp.61-71
    • /
    • 2021
  • The relationship between the Arctic Oscillation (AO) and surface air temperature (SAT) over Korea is re-examined using the long-term observation and reanalysis datasets for the period of December 1958 to February 2020. Over the entire period, Korean SAT is positively correlated with the AO index with a statistically significant correlation coefficient, greater than 0.4, only in the boreal winter. It is found that this correlation is not static but changes on the decadal time scale. While the 15-year moving correlations are as high as 0.6 in 1980s and 1990s, they are smaller than 0.3 in the other decades. It is revealed that this decadal variation is partly due to the AO structure change over the North Pacific. In the period of 1980s-1990s, the AO-related sea level pressure fluctuation is strong and well defined over the western North Pacific and the related temperature advection effectively changes the winter SAT over Korea. In the other periods, the AO-related circulation anomaly is either weak or mostly confined within the central North Pacific. This result suggests that Korean SAT-AO index relationship, which becomes insignificant in recent decades is highly dependent on mean flow change in the North Pacific.

Development of Design Technology of Korean Style Air-Inflated Double-Layer Plastic Greenhouse (한국형 공기주입 이중피복 플라스틱온실의 설계기술 개발)

  • Lee, Hyun-Woo;Sim, Sang-Youn;Nam, Hyo-Seok;Nam, Sang-Woon;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.185-191
    • /
    • 2009
  • The construction of experimental greenhouses, operating test, and analysis on variation of different environment factors were conducted to provide fundamental data for design of Korean style air-inflated double-layer plastic greenhouse. The development of technology of attaching plastic to the structure and fasteners to be able to keep airtight was required in order to maintain proper static pressure in air space of double layer coverings. The insulation effect of air inflated greenhouse was better than conventional type. The temperature of arch type roof was greater about $2^{\circ}C$ than peach type roof in air inflated greenhouse. It was recommended that the plastic should be attached at the edges without clearance length in order to ease installation and raise airtightness of double layer coverings. The transmittance of arch type roof was greater than peach type in air inflated one span greenhouse. The transmittance of air inflated greenhouse was greater than conventional type due to frame ratio and distance between double layers in three span greenhouse. The condensation occurred on conventional type greenhouse was more than air inflated type. It was required to examine for a long time in order to analyze it quantitatively.

Effects of Variation in Process Parameters on Cavity Pressure and Mechanical Strength of Molded Parts in LSR Injection Molding (LSR 사출성형의 공정조건 변화가 캐비티 압력 및 성형품의 기계적 강도에 미치는 영향)

  • Park, Hyung Pil;Cha, Baeg Soon;Lee, Jeong Won;Ko, Young Bae;Kim, Sang Gweon;Jung, Tae Sung;Kim, Dong Han;Rhee, Byung Ohk
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.2
    • /
    • pp.206-212
    • /
    • 2014
  • Liquid silicone rubber (LSR) has been widely used in automotive, electrical, and medical components. Thus, research on the use of LSR in the injection molding process is required to obtain high-quality and high-performance products. In this study, a mold was fabricated to examine the effects of the process parameters on the molding and mechanical properties of LSR parts. A computer-aided engineering analysis was used to optimize the air vent depth and curing temperature to decrease the flash at the air vents caused by the low viscosity of LSR. Temperature and pressure sensors were mounted in the mold to determine the effects of the process parameters on the temperature and pressure in the cavity. The tensile strength of the LSR parts was also examined in relation to the process parameters.

Experimental Study on Characteristics of Evaporation Heat Transfer and Oil Effect of $CO_2$ in Mini-channels (미세채널 내 이산화탄소의 증발 열전달 특성 및 오일의 영향에 관한 실험적 연구)

  • Lee, Sang-Jae;Kim, Dae-Hoon;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.16-22
    • /
    • 2009
  • In order to investigate $CO_2$ heat transfer coefficient and pressure drop by PAG oil concentration during $CO_2$ evaporation, the experiment on evaporation heat transfer characteristics in a mini-channels were performed. The experimental apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes($300{\sim}800kg/m^{2}s$), heat fluxes($10{\sim}40kW/m^2$) saturation temperatures($-5{\sim}5^{\circ}C$), and PAG oil concentration(0, 3, 5wt%). The variation of the heat transfer coefficient was different according to the oil concentration. With the increase of the oil concentration, the evaporation heat transfer coefficient decreased and the delay of dryout by oil addition was found. Pressure drop increased with the increase of the oil concentration and heat flux, and the decrease of saturation temperature.

The Effect of Fuel Injection Timing on Combustion and Power Characteristics in a DI CNG Engine (직분식 CNG 엔진에서 연료 분사시기의 변화가 연소 및 출력 특성에 미치는 영향)

  • Kang, Jeong-Ho;Yoon, Soo-Han;Lee, Joong-Soon;Park, Jong-Sang;Ha, Jong-Yul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.1
    • /
    • pp.193-200
    • /
    • 2007
  • Natural gas is one of the most promising alternatives to gasoline and diesel fuels because of its lower harmful emissions, including $CO_2$, and high thermal efficiency. In particular, natural gas is seen as an alternative fuel for heavy-duty Diesel Engines because of the lower resulting emissions of PM, $CO_2$ and $NO_x$. Almost all CNG vehicles use the PFI-type Engine. However, PFI-type CNG Engines have a lower brake horse power, because of reduced volumetric efficiency and lower burning speed. This is a result of gaseous charge and the time losses increase as compared with the DI-type. This study was conducted to investigate the effect of injection conditions (early injection mode, late injection mode) on the combustion phenomena and performances in the or CNG Engine. A DI Diesel Engine with the same specifications used in a previous study was modified to a DI CNG Engine, and injection pressure was constantly kept at 60bar by a two-stage pressure-reducing type regulator. In this study, excess air ratios were varied from 1.0 to the lean limit, at the load conditions 50% throttle open rate and 1700rpm. The combustion characteristics of the or CNG Engine - such as in-cylinder pressure, indicated thermal efficiency, cycle-by-cycle variation, combustion duration and emissions - were investigated. Through this method, it was possible to verify that the combustion duration, the lean limit and the emissions were improved by control of injection timing and the stratified mixture conditions. And combustion duration is affected by not only excess air ratio, injection timing and position of piston but gas flow condition.