• Title/Summary/Keyword: Air pollutants concentration

Search Result 613, Processing Time 0.026 seconds

Trends of Several Air Pollutants and the Effects of Ozone on the Plant Antioxidant system in Platanus occidentalis in Korea

  • Woo, Su-Young
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.2
    • /
    • pp.183-187
    • /
    • 2006
  • This study investigated concentrations of the several air pollutants and compared antioxidative enzyme activities on Platanus occidentalis because this tree species is one of the widespread street trees in Korea. This species has been emerging the ambient air pollutants during its growing periods. The purpose of this study was to identify the relationship between air pollution on the tree species and antioxidant enzyme activities on the trees. $O_3$, $NO_2$, CO and $SO_2$ concentrations of several cities in Korea were compared for last decades. Among the air pollutants, $O_3$ and $NO_2$ concentrations in six big cities in Korea showed similar increasing trends during this period. In contrast, $SO_2$ and CO concentrations in the same cities dramatically decreased between 1994 and 2005. Platanus occidentalis trees were controlled to investigate, ascorbate peroxidase (APX) and glutathione reductase (GR) activity. Ozone exposure generally increased APX and GR activities of tree seedlings. It is a typical compensatory strategy of stressed trees.

Mathematical Modelling of Biofilter for Waste Air Biotreatment (폐가스 처리에 대한 바이오필터의 수학적 모델링)

  • Im, Gwang-Hui
    • KSBB Journal
    • /
    • v.14 no.5
    • /
    • pp.550-560
    • /
    • 1999
  • There have been many research efforts on biofilter modeling including Ottengraf et al. who derived a model equation for the concentration profile of pollutants(e.g., VOCs) in the biolayer and solved their outlet concentration of the waste gas stream through biofilter. However, for most of research works done so far, the effects to explain the effect of adsorption of organic particles to medium(i.e., adsorbent) have been ignored. In this work biofilter modeling accompanying process lumping has been proposed and the theoretical effect of adsorption property of the medium, on the biofilter performance of eliminating organic components in waste gas stream, is intensively discussed.

  • PDF

Efficiency of Removal for PM10 and $NO_2$ by Air Cleaner in Residential Indoor Environment with Monte-Carlo Simulation (확률론적 모의실험을 이용한 공기청정기의 실내공기중 PM10과 $NO_2$ 제거효율에 관한 연구)

  • Lee , Cheol-MIn;Kim , Yoon-Shin;Lee , Tae-Hyung;Kim , Jong-Cheol;Kim , Jung-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.221-229
    • /
    • 2004
  • We estimated decreasing rate of indoor air pollutants which are PM10 and $NO_2$ by the air cleaner in indoor environment. This study respectively examined concentration of PM10 and $NO_2$ two times in 34 sites located in Seoul and Kyung-gi Do from April to September in 2003. Sectional period was respectively divided for operating the air cleaner and non-operating the air cleaner. Moreover, questionnaire was executed to grasp physical characteristic of objective building and residential characteristic of residents by using method of self-entry. There was a trend that concentration of PM10 and $NO_2$ separated number of residents during operating period respectively decreased among indoor air. According to the existence of smoker in indoor, both concentration of PM10 and $NO_2$ during operating period decreased in each case, and according to existence of pets, both cases decreased concentration of pollutants by operating the air cleaner. We used Monte-Calro simulation to remove uncertainty and identify efficiency of eliminated pollutants such as PM10 and $NO_2$ by the air cleaner. Average efficiency of removal for PM10 and $NO_2$ were 61.84${\pm}$23.04% and 48.67${\pm}$18.03% respectively.

A Study on the Distribution of Air Pollutant Concentration According to Micrometeorological Characteristics (미기상 특성에 따른 대기오염 농도분포에 관한 연구)

  • Kim, Yoo-Keun;Hong, Jung-Hae;Jeon, Byung-Il
    • Journal of Environmental Science International
    • /
    • v.3 no.1
    • /
    • pp.31-38
    • /
    • 1994
  • The diffusion of the pollutants released into atmosphere is dependent on its chemical reaction, topography and micrometeorological characteristics. The purpose of the study is to investigate how much micrometeorological characteristics such as stability, wind speed and mixing height affect the diffusion of the air pollutants. For this purpose, this paper let 1) the basic theory be K-theory, 2) eddy diffusivity and wind speed be dependent on mixing height and stability, and 3) Grout method be used for numeric calculation. The result was 1) the more unstable condition, the higher mixing height and the higher wind speed we, the lower pollutants concentration appears, 2) the most intensive effect on the distribution of the pollutant concentration is the atmospheric stability.

  • PDF

The Prediction and Evaluation Air Pollutants Concentration around Industrial Complex by using Atmospheric Dispersion Models -Based on ISCST3, FDM, AERMOD- (대기확산모델을 사용한 공단주변지역의 대기오염물질농도 예측 및 평가 -ISCST3, FDM, AERMOD를 중심으로-)

  • 이화운;원경미;배성정
    • Journal of Environmental Science International
    • /
    • v.8 no.4
    • /
    • pp.485-490
    • /
    • 1999
  • We will calculate concentration of air pollutants using ISCST3, FDM and AERMOD of models recommended in U. S. EPA which are able to predict concentration of short term for point source, complex like industrial complex, power plant and burn-up institution. Before executing model, as analyzing computational result of many cases according to selecting of input data, we will increasing predictable ability of model in limit range of model. Especially, we analyzed three cases-case of considering various emission rate according to time scale and not, case considering effect of atmospheric pollution materials removed by physical process. In our study, after comparing and analyzing results of three model, we choose the atmospheric dispersion model reflected well the characteristic of the area. And we will investigate how large the complex pollutant sources such as industrial complex contribute to atmospheric environment and air quality of the surrounding the area as predicting and estimating chosen model.

  • PDF

Measurement of Classroom Air Quality in large cities in autumn (가을철 도심지역 학교교사의 실내환경 측정연구)

  • Kim, Yun-Deok;Seo, Dong-Yeon
    • KIEAE Journal
    • /
    • v.10 no.3
    • /
    • pp.37-42
    • /
    • 2010
  • Together with the concern about the indoor air quality as sick house syndrome, the Ministry of Environment announced "Indoor Air Quality Control Law for the Multi Purpose Facility," which made the interests to be focused in the urgent understanding of current condition and preparation of measures about the indoor air pollution. The law was revised to obligatorily notify the amount of Formaldehyde and Volatile Organic Compounds in the case of newly constructed apartments with more than 100 houses. School also have its own indoor air quality guideline. Indoor air quality in school is very important because, children who very weak to indoor pollutants reside long time in there. The purpose of this paper is to to survey indoor air quality in school by field measurement. Field measurements were performed in 11 schools which were selected from 3 major cities(Incheon, Dae-jeon, chuncheon) in korea, Totally concentration of indoor pollutants were determined in 32 classroom. Target air pollutants were TVOC, formaldehyde, dust, CO, CO2. For the result of this investigation, Indoor air quality in classroom was very poor and it was found that some pollutants(TVOC, float bacteria) exceed the guideline.

Nocturnal Inversion Layer observed by Tethersonde and AWS System and its Relation to Air Pollution at Ulsan (Tethersonde와 기상탑 관측 자료를 이용한 울산지역 야간 역전에 따른 대기오염도 변화와의 관계)

  • Lim Yun-Kyu;Kim Yoo-Keun;Oh In-Bo;Song Sang-Keun
    • Journal of Environmental Science International
    • /
    • v.14 no.6
    • /
    • pp.555-563
    • /
    • 2005
  • This study presents the characteristics of nocturnal inversion layer and their effect on the concentration variations of surface air pollutants using tethersonde and automatic weather station (AWS, 2 layer tower) system in Ulsan during 2003, The method for the distinction of inversion intensity was decided based on the sum of nocturnal temperature gradient. As the results, there was a close correlation (correlation coefficient of 0,76) between the maximum inversion height obtained from tethersonde and the sum of nocturnal temperature gradient. The air pollutant concentration was also directly proportional to the inversion intensity. When the inversion intensity was strong in the nighttime, ozone $(O_3)$ concentration was lower, while nitrogen dioxide $(NO_2)$ concentration was higher. The carbon monoxide (CO) concentration was gradually higher according to the nocturnal inversion intensity, whereas sulfur dioxide $(SO_2)$ concentration was relatively constant. In addition, we found that there was no correlation between the inversion intensity and TSP concentration.

Measurement of Classroom Air Quality in large cities in summer (여름철 대도심 학교교실의 실내공기환경 측정연구)

  • Kim, Yun-Deok
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.63-74
    • /
    • 2007
  • Together with the concern about the indoor all quality as sick house syndrome, the Ministry of Environment announced "Indoor Air Quality Control Law for the Multi Purpose Facility," which made the interests to be focused in the urgent understanding of current condition and preparation of measures about the indoor air pollution. In Dec 2005, the law was revised to obligatorily notify the amount of Formaldehyde and Volatile Organic Compounds in the case of newly constructed apartments with more than 100 houses. School also have its own indoor air quality guideline, Indoor air quality in school is very important because, children who very weak to indoor pollutants reside long time in there. The purpose of this paper is to survey indoor air qualify in school by field measurement. Field measurements were performed in 11 schools which were selected from 3 major cities(Incheon, Dae-jeon, chuncheon) in korea, during July, 2004. Totally concentration of Indoor pollutants were determined in 27 classroom. Target air pollutants were TVOC, formaldehyde, dust, CO, CO2 and NO2. For the result of this investigation, Indoor air quality in classroom was very poor and it was found that some pollutants (TVOC, float bacteria) exceed the guideline.

Characteristics of the Distribution of High Ambient Air Pollutants with Sources and Weather Condition in Ulsan (오염원 및 기상 조건에 따른 울산지역의 고농도 대기오염 분포 특성)

  • Choi, Bong-Wook;Jung, Jong-Hyeon;Choi, Won-Joon;Shon, Byung-Hyun;Oh, Kwang-Joong
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.4 s.91
    • /
    • pp.324-335
    • /
    • 2006
  • Five sampling sites were selected to investigate the distribution characteristics of air pollutants with pollution sources and weather conditions in Ulsan. $SO_2,\;NO_2,\;O_3,\;CO,\;PM_{10}$ concentrations and weather conditions with time were analyzed by using several statistical methods. Also, the distribution characteristics of ambient air quality were estimated by pollution-rose and multi-regression analysis. As a result of the analysis, $NO_2,\;CO\;and\;PM_{10}$ concentrations were high in winter season, whereas $SO_2\;and\;O_3$ concentrations were high in summer season. This concentration distribution was caused by the unfavorable geographical location, which the residential area was located at the downwind direction to industrial area. From the pollution-rose, we confirmed that each pollutant influenced the downwind residential areas because of seasonal wind direction. $SO_2$ concentration has shown positive correlation of $0.2{\simm}0.3$ for $NO_2,\;PM_{10}$ and temperature, while $O_3$ concentration has shown negative correlation. Also, $NO_2$ and CO concentrations, pollutants generated by combustion, have shown positive correlation, while $O_3$ concentration and temperature have shown negative correlation. Therefore, it could be suggested that a seasonal air quality policy and a new guideline of air quality was necessary in each season with wind directions to reduce the air pollution level in Ulsan.

A Study on the Analysis of $CO_2$ Concentration Variation According to the Indoor Space Condition Changes (다양한 실내 환경에서의 $CO_2$ 농도 변화 분석 연구)

  • Ahn, Gwang-Hoon;Kwon, Jong-Won;Kim, Gyu-Sik;Kim, Hie-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.347-349
    • /
    • 2009
  • Air quality of indoor space environment is affected by various pollutants like as particles and chemical stuffs. The indoor air pollution affects directly the human respiration organs to cause consequently unpleasant mental status. The $CO_2$ concentration level is one of the harmful components of air pollutants. Major factor to increase the $CO_2$ concentration level is the people's breath amount in indoor. The car exhaust gas diffused from the around road also has strong affect on $CO_2$ concentration. There are some other reasons to affect the $CO_2$ concentration change, such as, real-time change of the population movement, closeness to the indoor air flow inlet window and changes in road car traffic amount. A remote monitoring system to measure environmental indoor air pollution concerning on the $CO_2$ concentration was studied and installed realized set-up model. Zigbee network configuration was applied for this system and the $CO_2$ concentration data were collected through USN network. A software program was developed to assure systematic analysis and to display real-time data on web pages. For the experimental test various condition was set up, like as, window opening, stopping air condition operation and adjusting fan heater work, etc. The analysis result showed the relation of various environmental conditions to $CO_2$ concentration changes. The causes to increase $CO_2$ concentration were experimentally defined as windows closing, the stopping air condition system, fan heater operation. To keep the $CO_2$ concentration under the legally required ppm level in public access indoor space, the developed remote measurement system will be usefully applied.

  • PDF