Efficiency of Removal for PM10 and $NO_2$ by Air Cleaner in Residential Indoor Environment with Monte-Carlo Simulation

확률론적 모의실험을 이용한 공기청정기의 실내공기중 PM10과 $NO_2$ 제거효율에 관한 연구

  • Lee , Cheol-MIn (Institute of Environmental and Industrial Medicine, Hanyang University) ;
  • Kim , Yoon-Shin (Institute of Environmental and Industrial Medicine, Hanyang University) ;
  • Lee , Tae-Hyung (Institute of Environmental and Industrial Medicine, Hanyang University) ;
  • Kim , Jong-Cheol (Institute of Environmental and Industrial Medicine, Hanyang University) ;
  • Kim , Jung-Ho (SAMSUNG ELECTRONICS Co., LTD)
  • 이철민 (한양대학교 환경 및 산업의학연구소) ;
  • 김윤신 (한양대학교 환경 및 산업의학연구소) ;
  • 이태형 (한양대학교 환경 및 산업의학연구소) ;
  • 김종철 (한양대학교 환경 및 산업의학연구소) ;
  • 김중호 (삼성전자(주) 시스템가전사업부)
  • Published : 2004.09.01

Abstract

We estimated decreasing rate of indoor air pollutants which are PM10 and $NO_2$ by the air cleaner in indoor environment. This study respectively examined concentration of PM10 and $NO_2$ two times in 34 sites located in Seoul and Kyung-gi Do from April to September in 2003. Sectional period was respectively divided for operating the air cleaner and non-operating the air cleaner. Moreover, questionnaire was executed to grasp physical characteristic of objective building and residential characteristic of residents by using method of self-entry. There was a trend that concentration of PM10 and $NO_2$ separated number of residents during operating period respectively decreased among indoor air. According to the existence of smoker in indoor, both concentration of PM10 and $NO_2$ during operating period decreased in each case, and according to existence of pets, both cases decreased concentration of pollutants by operating the air cleaner. We used Monte-Calro simulation to remove uncertainty and identify efficiency of eliminated pollutants such as PM10 and $NO_2$ by the air cleaner. Average efficiency of removal for PM10 and $NO_2$ were 61.84${\pm}$23.04% and 48.67${\pm}$18.03% respectively.

Keywords

References

  1. Vincent, D., Annesi, I., Festy, B. and Lambrozo, J. : Ventilation system, indoor air quality, and health out-comes in parisian modern office workers. Environ-mental Research, 75, 100-112, 1997 https://doi.org/10.1006/enrs.1997.3764
  2. 김신도 : 건축자재에서의 VOCs 방출량 측정. 2000년 실내 VOCs 토론회, pp.4, 2000
  3. 국립환경연구원 환경기술진흥센터 : 환경기술연구개발. 행정간행물, 제21호, pp.13, 2001
  4. 환경부 : 환경백서 2000, pp.125-127, 2001
  5. ASHRAE : Air Cleaners for Particulate Contaminants, ASHRAE Handbook, Ch, 1996
  6. Japan Standard Association: JIS C 9615, Air Cleaners, 1995
  7. 한국산업규격 :KS C 9314, 공기청정기, 1994
  8. Lee, K., Yanagisawa, Y., Spengler, J. D. and Billick, I. H. : Wind velocity effects of sampling rate of $NO_2$ badge. J. Expos. Anal. Environ. Epi., 2, 207-219, 2001
  9. 박민하, 김용표, 강창희 : 황사/비황사의 입자 조성 변화 : 1992-1996 봄철 고산 측정자료. 한국대기환경학회지, 17. 487-492, 2001
  10. 유경훈 : 공기청정기 시험법의 특성과 동향. 공기청정기술, 11(2), 40-49, 1998
  11. Copeland, T. L., Paustenbach, D. J., Harris, M. A. and Otani, J. : Comparing the results of a monte carlo analysis with EPA's reasonable maximum exposed individual(RMEI); A case study of a former wood treatment site. Regul. Toxicol. Pharmacol. ,18, 275-312, 1993 https://doi.org/10.1006/rtph.1993.1059