• 제목/요약/키워드: Air pollutants concentration

검색결과 617건 처리시간 0.032초

친환경 자동차 도입에 따른 지역별 오존 농도 변화 특성 분석 (Characterizing Regional Ozone Concentration Changes Due to the Adoption of Eco-Friendly Vehicles in South Korea)

  • 양채영;전원배;김동진;박재형;최현식;문정혁
    • 한국환경과학회지
    • /
    • 제32권9호
    • /
    • pp.613-626
    • /
    • 2023
  • This study investigates the impact of increased adoption of eco-friendly vehicles on ozone (O3) concentrations in South Korea, utilizing the community multiscale air quality (CMAQ) model. In the summer of 2017 (June-August), we conducted two experiments: a BASE experiment, representing baseline emissions, and an R_30 experiment, involving a 30% emission reduction due to eco-friendly vehicles. The contrast between these experiments reveals that, while most air pollutants decreased with reduced vehicle emissions, O3 concentrations surprisingly increased (up to 2.1 parts per billion) across South Korea. A further examination of O3 concentration changes was conducted by analyzing daytime and nighttime variations as well as wind direction. During the daytime, O3 concentrations notably rose near metropolitan areas due to reduced O3 titration (O3 + NO → O2 + NO2) resulting from emission reductions. At nighttime, O3 concentrations exhibited a greater increase, attributed to the transport of daytime-generated O3 to rural regions. Notably, the impact of reduced emissions in metropolitan areas on O3 concentrations in downwind areas varied depending on the prevailing wind direction. These findings highlight that the promotion of eco-friendly vehicles, though effective in lowering certain air pollutants, might not directly influence O3 concentrations. This study underscores the need to comprehensively understand the complicated chemistry of O3 to develop effective strategies for air quality management.

연소 배출가스 중 SO2 농도에 따른 응축성먼지 변화에 관한 연구 (A Study on the Change of Condensable Particulate Matter by the SO2 Concentration among Combustion Gases)

  • 유정훈;임슬기;송지한;이도영;유명상;김종호
    • 한국대기환경학회지
    • /
    • 제34권5호
    • /
    • pp.651-658
    • /
    • 2018
  • Particulate matter (PM) emitted from fossil fuel-combustion facilities can be classified as either filterable or condensable PM. The U.S. Environmental Protection Agency (EPA) defined condensable PM as material that is in the phase of vapor at the stack temperature of the sampling location which condenses, reacts upon cooling and dilution in the ambient air to form solid or liquid in a few second after the discharge from the stack. Condensable PM passed through the filter media and it is typically ignored. But condensable PM was defined as a component of primary PM. This study investigates the change of condensable PM according to the variation in the sulfur dioxide of combustion gas. Domestic oil boilers were used as the source of emission ($SO_2$) and the level of $SO_2$ concentration (0, 50, 80, and 120 ppm) was adjusted by diluting general light oil and marine gas oil (MGO) that contains sulfur less than 0.5%. Condensable PM was measured as 2.72, 6.10, 8.38, and $13.34mg/m^3$ when $SO_2$ concentration in combustion gas were 0, 50, 80, and 120 ppm respectively. The condensable PM tended to increase as the concentration of $SO_2$ increased. Some of the gaseous air pollutants emitted from the stack should be considered precursors of condensable PM. The gas phase pollutants which converted into condensable PM should reduced for condensable PM control.

실내환경중의 산소발생기 사용에 대한 인식도 평가 (Assessment of Conscious Coginition Degree and Survey on Oxyen Generators using the Indoor Environment)

  • 손종렬;조윤수;이규현;황상용
    • 환경위생공학
    • /
    • 제18권4호
    • /
    • pp.64-69
    • /
    • 2003
  • Recently, Indoor air quality(IAQ) in workplace, residential environments and office has been concern of people, scientists and related the public. The oxygen in air was very important and essential element in every aspect of life. This study was performed on a questionnaire survey of 400 people about their awareness of indoor air quality, oxygen generators and measured of oxygen concentration in indoor environment. The results obtained were as follows; As respondents are having their 90% of daytime indoors a day, and 80% of them can feel indoor air pollutions degrees directly by particle matters. The control of most important problems of IAQ was the poor ventilation. We know that 22% of the respondents was recognized the oxgen generator. And for the installation of indoor pollution control equipment, 20% of all respondents installed oxygen generators because almost respondents was not satified the trust of ability purified indoor air pollutants. In the experimental results, it was found that the oxygen concentration of sampling sites were in the range of 20~23.5%. Therefore, it was recommended that the government related IAQ was suggested the guideline and control of oxygen generators. Finally, it appeared that the oxygen generators using indoor environment can be applied to new technology for cleaning of indoor air.

고형연료제품 사용시설에 따른 다환방향족탄화수소 (PAHs)의 배출특성 및 유해성 평가 (Emission Characteristics and Hazard Assessment of Polycyclic Aromatic Hydrocarbon (PAHs) from Solid Fuel Facilities)

  • 허선화;임승영;강대일;김대곤;전기준;장기원
    • 한국대기환경학회지
    • /
    • 제33권4호
    • /
    • pp.333-341
    • /
    • 2017
  • Recently, the earth has shown the limit of environmental capacity. It is also experiencing an environmental crisis with rising energy prices and depletion of coal. Therefore, development of renewable energy is very important solution. However, waste fuel solid are renewable fuels, but they cause environmental problems. In this study, the emission characteristics of hazardous air pollutants were analyzed through measurements at the facilities using solid fuels (SRF, BIO-SRF). Analysis method of PAHs are based on the Korea Standard Methods for Examination. The analysis of PAHs showed that the concentration much higher in Naphthalene, and Benzo(a)pyrene showed at a higher concentration incertain sources. As a result of gas phase and particle phase PAHs, most of Benzo(a)pyrene appeared to be particulate. Through the results of this study will provide basic data for atmospheric environmental management.

호남지역의 다중이용시설별 실내공기질 실태 조사 (Indoor Air Quality in Various Type of Public Facilities at Honam Province)

  • 서병량;정만호;전준민
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.387-397
    • /
    • 2006
  • This study was performed to investigate the characteristics of indoor air quality(IAQ) in 91 public facilities from September 2004 to March 2005 in the Honam province(Chonnam, Gwangju). The measured air pollutants are $PM_{10}$, formaldehyde(HCHO), CO, $CO_{2}$ and total suspended bacteria(TSB), the maintenance standard materials of IAQ management law established by ministry of environment in Korea(MOE). We also surveyed establishment and operation of ventilation equipment. It was measured $1.2m{\sim}1.5m$ on the floor between 8 o'clock AM and 7 o'clock PM. As the result, $PM_{10}$ and CO was showed the highest concentration, $188.89{\mu}g/m^{3}$, 8.67 ppm, at the indoor parking. The concentration of HCHO was the highest in large store and steamer room. The concentration was respectively $118.70{\mu}g/m^{3}\;and\;113.21{\mu}g/m^{3}$. The concentration of $CO_{2}$ was the highest at the reading room of the library on the condition of natural ventilation. The concentration of $CO_{2}$ was 1,816 ppm and higher than the IAQ standards established by MOE. The TSB was just measured in the hospital and silver town. It was the highest at the admission room of hospital. The concentration of TSB was $766CFU/m^{3}$. The public facilities of this study were not exceed each maintenance standards except $CO_{2}$ but it was surveyed that the management will be needed about some air pollutant according to target facilities.

울산광역시 아황산가스(SO2)의 최적관측소 평가방법 (Method for Evaluating Optimal Air Monitoring Sites for SO2 in Ulsan)

  • 임정현;윤상후
    • 한국환경과학회지
    • /
    • 제26권9호
    • /
    • pp.1073-1080
    • /
    • 2017
  • Manufacturing and technology industries produce large amounts of air pollutants. Ulsan Metropolitan City, South Korea, is well-known for its large industrial complexes; in particular, the concentration of $SO_2$ here is the highest in the country. We assessed $SO_2$ monitoring sites based on conditional and joint entropy, because this is a common method for determining an optimal air monitoring network. Monthly $SO_2$ concentrations from 12 air monitoring sites were collected, and the distribution of spatial locations was determined by kriging. Mean absolute error, Root Mean Squared Error (RMSE), bias and correlation coefficients were employed to evaluate the considered algorithms. An optimal air monitoring network for Ulsan was suggested based on the improvement of RMSE.

도시철도 객실 공기질 평가모델 개발 (Development of Air Quality Assessment Model for Subway Cabin)

  • 권순박;조영민;박덕신;김세영;박재형;조관현;유건종;김정수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.157-160
    • /
    • 2010
  • Management of indoor air quality of underground subway station is an important issue since the limited natural ventilation, limited sunshine incoming, and highly moistured atmosphere. The improvement in IAQ of platform is expected because most stations were installed with platform screen door currently, however, the poor air quality in tunnel might be affecting subway cabin indoor. In this study, we developed the air quality assessment model based on computational fluid dynamics. The geometry of air ventilation unit, seat, LCD monitors, and passengers were modeled using commercial software (Design Modeler) and fluid pattern and pollutants trajectories were analyzed by using CFX. We predicted the thermal comfort by predicted mean vote (PMV), distribution of CO2 and PM10 concentration. It is expected that this model can be used for the performance test of air cleaners which are under development.

  • PDF

태풍 우사기와 나리 통과 후 부산지역 미세먼지 농도의 급상승에 관한 연구 (Sudden rise of fine particle concentration after Typhoon USAGI and NARI passage in Busan)

  • 전병일
    • 환경영향평가
    • /
    • 제20권4호
    • /
    • pp.557-564
    • /
    • 2011
  • This study was conducted to investigate the sudden rise of fine particle concentration after the passage of typhoon USAGI and NARI in Busan. Nocturnal inversion layer was formed at atmospheric boundary layer and wind direction changed from southerly wind to northeasterly wind after USAGI passed through Busan. Fine particle concentration in Busan rapidly increased by subsidence of air pollutants released from sources and dust transported from in the vicinity of industrial regions. Wind direction changed from northeasterly wind to southeasterly wind, wind velocity increased and lower atmosphere became extremely unstable after NARI passed through Busan. $PM_{10}$ concentration of Busan increased sharply because of surface dust dispersed by strong wind. Fine particle concentration generally decreases by precipitation and wind after typhoon passes through. However, the concentration can also go up not only by subsidence and transportation in nocturnal inversion layer but also by surface dust which temporarily occurs by strong wind.

실내공기질에 따른 재실자의 인식성 공기질 평가 (Perceived Air Quality Assessment of Occupants According to Indoor Air Quality)

  • 우병렬;이현수;안호기;정순원;황문영;박충희;유승도;양원호
    • 한국환경과학회지
    • /
    • 제20권1호
    • /
    • pp.61-69
    • /
    • 2011
  • Perceived air quality (PAQ) is defined as evaluation of indoor air satisfaction and comfortable sensory by occupants. However, there are differences between criteria of indoor pollutants and lowest sensory thresholds. In this study, we compared indoor PAQ by questionnaire with measured benzene, toluene and nitrogen dioxide ($NO_2$) concentrations in home indoors. The $NO_2$ concentration was the highest in Seoul, while benzene and toluene were the highest in Asan. Average PAQ score in winter was higher than that in summer. Significant correlations between PAQs of home indoor air pollution and measured pollutant concentrations were not shown and correlation coefficients (r) ranged between -0.453

Short-term Effects of Ambient Air Pollution on Emergency Department Visits for Asthma: An Assessment of Effect Modification by Prior Allergic Disease History

  • Noh, Juhwan;Sohn, Jungwoo;Cho, Jaelim;Cho, Seong-Kyung;Choi, Yoon Jung;Kim, Changsoo;Shin, Dong Chun
    • Journal of Preventive Medicine and Public Health
    • /
    • 제49권5호
    • /
    • pp.329-341
    • /
    • 2016
  • Objectives: The goal of this study was to investigate the short-term effect of ambient air pollution on emergency department (ED) visits in Seoul for asthma according to patients' prior history of allergic diseases. Methods: Data on ED visits from 2005 to 2009 were obtained from the Health Insurance Review and Assessment Service. To evaluate the risk of ED visits for asthma related to ambient air pollutants (carbon monoxide [CO], nitrogen dioxide [$NO_2$], ozone [$O_3$], sulfur dioxide [$SO_2$], and particulate matter with an aerodynamic diameter <$10{\mu}m$ [$PM_{10}$]), a generalized additive model with a Poisson distribution was used; a single-lag model and a cumulative-effect model (average concentration over the previous 1-7 days) were also explored. The percent increase and 95% confidence interval (CI) were calculated for each interquartile range (IQR) increment in the concentration of each air pollutant. Subgroup analyses were done by age, gender, the presence of allergic disease, and season. Results: A total of 33 751 asthma attack cases were observed during the study period. The strongest association was a 9.6% increase (95% CI, 6.9% to 12.3%) in the risk of ED visits for asthma per IQR increase in $O_3$ concentration. IQR changes in $NO_2$ and $PM_{10}$ concentrations were also significantly associated with ED visits in the cumulative lag 7 model. Among patients with a prior history of allergic rhinitis or atopic dermatitis, the risk of ED visits for asthma per IQR increase in $PM_{10}$ concentration was higher (3.9%; 95% CI, 1.2% to 6.7%) than in patients with no such history. Conclusions: Ambient air pollutants were positively associated with ED visits for asthma, especially among subjects with a prior history of allergic rhinitis or atopic dermatitis.