• Title/Summary/Keyword: Air pollutants$PM_{10}$

Search Result 425, Processing Time 0.023 seconds

A Field Survey on the Characteristics of Air Pollutants Emission from Commercial Charcoal Kiln (숯가마에서 발생하는 대기오염물질의 배출특성에 관한 현장조사 연구)

  • Park, Seong-Kyu;Choi, Sang-Jin;Kim, Jin-Yun;Park, Gun-Jin;Hwang, Ui-Hyun;Lee, Jeong-Joo;Kim, Tae-Sik
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.5
    • /
    • pp.601-614
    • /
    • 2013
  • The commercial charcoal kiln was projected the largest source of biomass burning sector in Korea. Commercial charcoal kiln was operated to emit air pollutants into the air without any air pollution prevention equipment. The object of this field survey was to understand characteristics of air pollutants concentration and emission factors and to provide preliminary data for effective processor from oak charcoal manufacturing process. As result of field survey, TSP, $PM_{10}$ and $PM_{2.5}$ concentration from charcoal kiln were 400~37,000 $mg/m^3$. These values were over the 100 $mg/m^3$ in TSP, this value was effluent quality standard of Clean Air Conservation Act. The average concentration of CO, $SO_2$ and TVOC were 2~5%. 0~110 ppm and 820~10,000 ppm respectively. The emission factors were 42.4 g-PM/kg-oak in TSP, 40.3 g-PM/kg-oak in $PM_{10}$, 38.2 g-PM/kg-oak in $PM_{2.5}$, 182.5 g-CO/kg-oak, 1.0 g-NO/kg-oak, $SO_2$ 0.2 g-$SO_2/kg$-oak and 104.4 g-TVOC/kg-oak. The part of commercial charcoal kiln had air pollution prevention equipment but it was difficult to work properly. Much wood tar excreted in exhaust emissions from oak charcoal manufacturing process. This wood tar was cause of many troubles sticking in the air pollutant prevention equipment. For handling particulate matters and gaseous air pollutants from oak charcoal manufacturing process in biomass burning, air pollutant prevention equipment design and management needs preprocessor for removal wood tar.

Characteristics of Air Pollutants Emission from Medium-duty Trucks Equipped EGR and SCR in Korea (국내 EGR과 SCR 장착 중형트럭 대기오염물질 배출 특성)

  • Son, Jihwan;Kim, Jounghwa;Jung, Sungwoon;Yoo, Heungmin;Hong, Heekyung;Mun, Sunhee;Choi, Kwangho;Lee, Jongtae;Kim, Jeongsoo
    • Journal of ILASS-Korea
    • /
    • v.21 no.3
    • /
    • pp.130-136
    • /
    • 2016
  • NOx and PM are important air pollutants as vehicle management policy aspect. Medium-duty truck is the main source of the pollutants although the vehicle market share is only 3.5%. National emission portion of NOx and PM form the mobile sourece are 14% and 16% respectively. In this study it was investigated that characteristics of air pollutants emission on medium duty truck equipped with EGR and SCR system. Vehicle's test reflected driving cycle on the chassis dynamometer, and applied test cycle was WHVC(World Harmonized Vehicle Cycle) mode. The test cycle include three segments, represent urban, rural and motorway driving. Based on the test results NOx, PM, HC were less emitted form SCR vehicle than EGR vehicle. And CO was less emitted form EGR vehicle than SCR vehicle due to CO oxidation reaction on DPF surface. And most air pollutants reduced as average vehicle speed increased. Pollutants were less emitted on motorway section than urban and rural sections. But highly NOx emission on motorway section was verified according to increased EGR ratio on fast vehicle speed. HC and CO additional emission was identified as 68%, 58% respectively during SCR vehicle's cold engine start emission test. NOx additional emission was detected by 24% on SCR vehicle's condition of engine cold start while not detected on vehicle equipped with EGR. SCR vehicle's additional NOx emission was derived from low reaction temperature during engine cold start condition. medium-duty truck emission characteristics were investigated in this study and expected to used to improve air pollutants management policy of medium-duty truck equipped with SCR & EGR.

The Study on Secondary Pollutants of $PM_{10}$ in Pocheon (포천지역에서 측정한 $PM_{10}$중 2차 생성입자에 관한 연구)

  • Park Tae-Sool
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.4 s.58
    • /
    • pp.9-20
    • /
    • 2005
  • The purpose of the study was characteristics of secondary pollutants of $PM_{10}$ collected in pocheon between August 2002 and June 2003. The ambient concentrations of $PM_{10}$ mass, 9 water-soluble anions and cations, and 13 bulk composition trace elements were determined from filter samples collected by $PM_{10}$ high volume air sampler(UV-15H, Graseby-Anderson Co., USA). During this period average $PM_{10}$ mass concentration was $83.8{\mu}g/m^3(49.8{\mu}g/m^3\~111.6{\mu}g/m^3)$ in Pocheon. Mechanism for transformation of secondary pollutants by soluble ion components is divided into two categories; $NaNO_3$ type by the reaction of sea salt and $HNO_3$ in the atmosphere, and nitrate salt or phosphate salt type such as $(NH_4)_2SO_4,\;NH_4NaSO_4,\;and\;(NH_4)_2SO_4(2NH_4O_3)$.

A Spatial Analysis of the Causal Factors Influencing China's Air Pollution

  • Kim, Yoomi;Tanaka, Katsuya;Zhang, Xinxin
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.194-201
    • /
    • 2017
  • This study investigates the factors that affect China's air pollution using city-level panel data and spatial econometric models. We address three air pollutants ($PM_{10}$, $SO_2$, and $NO_2$) present in 30 cities in China between 2004-2012 using global OLS and spatial models. To develop the spatial econometric analysis, we create a spatial weights matrix to define spatial patterns based on two neighborhood criteria - the queen contiguity and k nearest neighbors. The results show that the estimated coefficients are relatively consistent across different spatial weight criteria. The OLS models indicate that the effect of green spaces is statistically significant in decreasing the concentrations of all air pollutants. In the $PM_{10}$ and $SO_2$ analyses, the OLS models find that the number of buses and population density are also positively related to a reduction in the concentration of air pollutants. In addition, an increase in the temperature and the presence of secondary industries increase $SO_2$ and $NO_2$ concentrations, respectively. All spatial models capture a positive and significant effect of green spaces on reducing the concentration of each air pollutant. Our results suggest that green spaces in cities should receive priority consideration in local planning aimed at sustainable development. Furthermore, policymakers need to be able to discern the differences among pollutants when establishing environmental policies.

Assessment of the Indoor Air Quality at Schools in Ulsan (울산지역 학교의 실내공기질 평가)

  • Jung, Jong-Hyeon;Seo, Bo-Sun;Ju, Dong-Jin;Park, Man-Chul;Shon, Byung-Hyun;Phee, Young-Gyu
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.6
    • /
    • pp.472-479
    • /
    • 2010
  • The purpose of this study was to investigate the concentration of indoor air pollutants at 63 elementary schools, 41 middle schools and 51 high schools in Ulsan from the beginning of May to the end of December, 2008. To assess the indoor air quality of the various classrooms, the 8 indoor air pollutants such as $CO_2$, CO, $NO_2$, $O_3$, $PM_{10}$, TVOCs, HCHO and TBC were measured and analyzed. The mean concentrations of $PM_{10}$ and TBC in the elementary schools were significantly higher than those of middle and high schools (p < 0.01). For the HCHO, the multi-use practice rooms showed an average 1.5 times higher than general classrooms. In schools located in urban areas, the concentrations of CO, $O_3$, $PM_{10}$, HCHO and TBC were lower than in the vicinity of industrial complexes. The exceeding rate of the school air quality maintenance limits in the 6 air pollutants by law were 6.7%, 3.5%, 1.7%, 18.2%, 13.0% and 18.4% for $CO_2$, $NO_2$, $O_3$, $PM_{10}$, HCHO and TBC, respectively. Based on these results $PM_{10}$ and TBC have to be in the order of priority of need to improve the classroom air quality in elementary school of Ulsan.

Research on Air Pollution Status and Its Control Technology in China

  • Xia, Sai;Yang, Zhen Yu;Jin, Jie
    • Journal of Urban Science
    • /
    • v.8 no.2
    • /
    • pp.47-52
    • /
    • 2019
  • China's rapid economic growth has also caused serious air pollution, endangering the health of the people and the good operation of the surrounding ecological environment.In this paper, the current situation of air pollution in China is briefly described, and the sources and changing trends of major air pollutants (including PM10, PM2.5, SO2, NO2, CO and O3)are analyzed. Meanwhile, the treatment technologies and measures for atmospheric pollutants under the current situation.

Washout Removal Efficiencies of Major Air Pollutants by Precipitation

  • Kim, Dong-Sool;Lim, Deuk-Yong;Heo, Jeong-Sook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E2
    • /
    • pp.97-106
    • /
    • 2002
  • The purpose of this study was to quantitatively estimate the washout removal efficiencies of criteria air pollutants such as SO$_2$, TSP, PM10, CO, NO$_2$, and O$_3$corresponding to the amounts and durations of precipitation. The removal patters by washout were studied with air pollutants data and the corresponding precipitation data in Seoul, Korea during the periods of 1990 to 1999. In addition, washout patterns were classified into four seasons and four time Bones, i.e., night, morning, afternoon, and evening. In this study, natures of air pollutants by sequential precipitation were also intensively studied by examining the linear relationships between removal efficiencies and the amounts and durations of precipitation for each pollutant. The results of this study showed that SO$_2$, TSP, and O$_3$were rapidly removed by initial precipitation; however, NO$_2$was slowly removed 2-hour after precipitation. Both CO and PM10 were weakly removed by washout and their removal patters showed to be irregular.

The Investigation and Comparison of Characteristics of Air Pollution for Cohort Study in Chungju with Industrial Cities (대조코호트 연구를 위한 충주의 대기오염현황 조사와 산단지역과의 비교)

  • Kim, Jae-Hoon;Wee, Seong-Seung;Nam, Sang-Hoon;An, Jung-Sun;Kim, Dae-Sun
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • The purpose of this study was to investigate air quality in Chungju, Korea, using data obtained with a local air quality monitoring system. We have utilised cohort studies to investigate the relations between environmental pollution and the health of residents near large industrial complexes since 2004. This study analyzes the $O_3,\;NO_2,\;SO_2,\;CO\;and\;PM_{10}$ concentration in Chungju from 2002 to 2006. Air pollutants are closely related to the number of manufacturing facilities and cars, energy utilization and weather conditions. Generally, the diurnal concentration of air pollutants in Chungju reached the highest level in the morning (about$08:00{\sim}$) and early evening (about$19:00{\sim}$). On the other hand, the diurnal concentration of ozone as recorded gives the highest amount in late afternoon (about$16:00{\sim}$) and lowest in early morning (about$08:00{\sim}$). The concentration of air pollutants in Chungju was highest from winter to spring and lowest during the summer season. On the other hand, the monthly variation of ozone concentration was greatest in June and smallest in December. Also the, $PM_{10}$ concentration posted the highest record in April and the lowest during September. In general, this study analyzed air pollution changes in Chungju as well as in large scale industrial complex regions within Korea such as Ulsan, Pohang, Kwangyang, Sihwa Panwol and Gangneung in Korea. We compared the air quality of Chungju with those of these cites and found that air pollutants except for CO in Chungju was generally lower than large industrial complex regions.

Development of Source Profiles and Estimation of Source Contribution for Hazardous Air Pollutants by the Principal Component Analysis in Indoor Air

  • Kim, Yoon-Shin;Hong, Seoung-Cheol;Lee, Cheol-Min;Kim, Jong-Cheol;Jeon, Hyung-Jin;Song, Kyoung-Min;Roh, Young-Man
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.254-258
    • /
    • 2005
  • The purpose of this study is to characterize the indoor-outdoor relationship of airborne pollutants and recognize probable sources in inside and outside individual apartments in Seoul metropolitan. Simultaneous air monitoring in inside and outside of the 16 Korean Apartments classified into 2groups: less than 1 year old and more than 4 years old from October, 2004 to February, 2005were sampled f3r airborne pollutants(volatile organic compounds, formaldehyde, respiratory particles, carbon dioxide and bacteria) using the Korean Indoor Air Quality Official Method. The concentrations of $CO_2$, TVOCs, HCHO, bacteria and PM10 in the less than 1 year old apartments were determined to be $773.6{\pm}422.3ppm$, $4,393.8{\pm}2,758.2{\mu}g/m^3$, $98.0{\pm}56.4{\mu}g/m^3$, $254.0{\pm}186.3CFU/m^3$ and $31.7{\pm}14.8{\mu}g/m^3$, respectively, Also, the concentrations of those in the more than 4 years old apartments were determined to be $798.9{\pm}266.5ppm$, $792.7{\pm}398.3{\mu}g/m^3$, $70.0{\pm}30.7{\mu}g/m^3$, $245.6{\pm}122.0CFU/m^3$, $49.7f28.7{\pm}g/m^3$, respectively. The average ratios of the indoor and outdoor concentrations of $CO_2$, TVOCs, HCHO, bacteria and PM10 were 2.2, 3.6, 3.1, 3.9 and 1.4, respectively. These results of this analysis is suggested that $CO_2$, TVOCs, HCHO, bacteria and PM10 in indoor air are both emitted from source within the apartment environment and partly come from outdoor air. With the above considerations in mind, it is suggested that the research for source contribution of indoor air pollutants should be expanded and the detailed interpretation of the results on these needed further study(using principal component analysis(PCA).

  • PDF

Efficiency of Removal for Indoor air pollutants by Air Cleaners in the Indoor Environments (공기청정기의 일부 실내공기 오염물질 제거효율에 관한 연구)

  • Lee Tae-Hyung;Kim Yoon-Shin;Hong Seung-Cheol;Lee Cheol-Min;Kim Jong-Cheol;Jeon Hyung-Jin;Kim Jung-Ho
    • Journal of Environmental Science International
    • /
    • v.14 no.5
    • /
    • pp.491-497
    • /
    • 2005
  • In this study, we investigated $PM_{10},\;NO_2$, and l-hydroxypyrene(1-OHP) in urine at indoor environments which are 35 houses and 20 hospitals for using air cleaner and non-using air cleaner in Seoul metropolitan area and Kyoung-gi province from April, 2003 to February, 2004. Moreover, we examined effect of improvement for indoor air quality and health effect by concentration of 1-OHP also we investigated removal efficiency by air cleaner for $PM_{10},\;NO_2$, and 1-OHP that were 28.5\%,\;27.4\%,\;and\;42.1\%$ respectively. Concentration of$PM_{10},\;NO_2$, and 1-OHP were $19.02\pm18.14{\mu}g/m^3,\;8.66\pm3.06ppb,\;and\;0.19\pm0.18{\mu}g/g$, creatinine when air cleaner was no worked. The concentration for $PM_{10},\;NO_2$. and 1-OHP were $13.60\pm10.79{\mu}g/m^3,\; 6.29\pm2.71ppb,\;and\;0.11\pm0.10{\mu}g/g$ creatinine, respectively. It was significant statistically. Therefore, it is considered using the air cleaner to remove the partial pollutants in indoor environment and is positive effect for health.