• 제목/요약/키워드: Air induction

검색결과 372건 처리시간 0.04초

Contribution of Maxwell Stress in Air on the Deformations of Induction Machines

  • Fonteyn, K.A.;Belahcen, A.;Rasilo, P.;Kouhia, R.;Arkkio, A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.336-341
    • /
    • 2012
  • Deformations in a cage-induction machine are investigated with simulations. The contribution of the Maxwell stress in the air gap and coil regions of the machine on the deformation is studied by comparing results obtained with and without inclusion of the stress into the calculation. The work attests the acceptability of an energy-based magneto-mechanical model for a 2D mesh of two different rotating electrical machines.

자기부상열차용 편측식 선형 유도전동기의 설계특성 검토 (Investigation of Design Parameters of Single Sided Linear Induction Motor for MAGLEV)

  • 박영호;최열준;김정철;최종묵
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.49-54
    • /
    • 2005
  • Linear metro with single sided linear induction motor is applied to the urban transit system because of non adhesion drive. But linear induction motor is required to reduce the energy consumption to maximize efficiency of LIM. In this paper, design requirements such as pole pitch, motor length, air gap, overhang length and the material of secondary sheet are investigated as major parameter of SLIM. It is effective for increasing the efficiency to adopt the copper reaction plate and decrease the mechanical air gap as small as possible.

  • PDF

Tapped winding을 이용한 선형유도전동기의 자속검출에 관한 연구 (A Study on Flux Sensing of Linear Induction Motor Using Tapped Winding)

  • 임달호;권병일;김창업;임형빈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.948-950
    • /
    • 1993
  • A method of flux sensing using tapped winding is described for measuring air gap flux in linear induction motor. This method which utilizes coils of motor itself is neither affected by temperature nor resistive voltage drop due to stator current in the motor coils. So it can measure air gap flux in reliable manner. The tapped wilding method has been implemented in experiment and the result shows that this method can be sufficiently used in direct vector control of linear induction motor.

  • PDF

자속 센서를 이용한 농형 유도전동기의 진동검출 기법 (A Method for Vibration Detection of Squirrel Cage Induction Motors Using the Flux Sensor)

  • 황돈하;이상화;한상보;선종호;강동식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1057-1058
    • /
    • 2007
  • This paper proposes an alternative vibration detection method in a squirrel-cage induction motor using flux sensors. The air-gap flux will be changed when mechanical vibration occurs by bearing fault as well as broken rotor bar and air-gap eccentricity. For detecting those flux variations due to vibration, search coils are installed at stator slots. The induction motor with 380 [V], 7.5 [kW], 4 [Poles], 1,760 [rpm] ratings is used. Magnitudes and distortion of the induced voltage from flux sensors are used to discriminate faulted types. As a result, the flux sensor has been proven to be useful for vibration detection. It is compared to the result with vibration sensor as well.

  • PDF

Fluid Heating System using High-Frequency Inverter Based on Electromagnetic Indirect Induction Heating

  • Kim Yong-Ju;Shin Dae Cheul;Kim Kee Hwan;Uchihori Y.;Kawamura Y.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.69-74
    • /
    • 2001
  • In this Paper are described the indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20kHz to 50kHz. A specially designed induction heater, which is composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates, is inserted into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF

Novel Electromagnetic Induction Eddy Current DPH based Continuous Pipeline Fluid Heating using Soft Switching PWM High Frequency Inverter

  • Nam, Jing-Rak
    • Journal of information and communication convergence engineering
    • /
    • 제6권3호
    • /
    • pp.305-309
    • /
    • 2008
  • This paper presents an innovative prototype of a new conceptual electromagnetic induction eddy current based fluid heating appliance using voltage-fed quasi resonant zero voltage soft switching PWM high-frequency inverter using IGBTs, which can operate at a constant frequency variable power regulation scheme. The promising simple high efficient low noise inverter type electromagnetic induction eddy current based pipeline fluid heating appliance is proposed for saturated steam generator, superheated steam generator, hot water and hot air producer, metal catalyst heating for exhaust gas cleaning in engine. Under these technological backgrounds, a novel electromagnetic induction eddy current Dual Packs Heater(DPH) based pipeline fluid heating incorporates thin metal layer type package for continuous fluid heating appliances applying two types of voltage-fed quasi load resonant ZVS-PWM high frequency inverter. The unique features of a novel electromagnetic induction eddy current DPH based continuous pipeline fluid heating appliance is illustrated on the basis of simulation and discussed for the steady state operating characteristics and experimental results.

외측 회전자형 심구형 유도전동기의 특성 (The characteristics of deep slot outside rotor type IM)

  • 김현수;안병원;김성환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권1호
    • /
    • pp.30-36
    • /
    • 2002
  • This paper presents a developed deep slot squirrel cage induction motor fur the fan. Nearly all of the induction motors consist of two parts, rotor and stator, and the position of rotor is generally inside of stator. However, the rotor of the developed induction motor is located outside of stator. It is believed that the outside rotor type induction motor is suitable for the fan due to its large inertia, that is, it is considered that the change of air flow rate resulting from input power or load fluctuation is reduced. It is considered that the results of this paper can be used for the development of the outside rotor type induction motor.

유도전동기 온라인 감시진단 시스템 개발 (Development of Online Monitoring System for Induction Motors)

  • 김기범;윤영우;황돈하;선종호;정태욱
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.23-30
    • /
    • 2014
  • This paper presents an on-line diagnosis system for identifying health and faulted conditions in squirrel-cage induction motors using stator current, temperature, and partial discharge signals. The proposed diagnosis system can diagnose induction motor faults such as broken rotor bars, air-gap eccentricities, stator winding insulations, and bearing faults. Experimental results obtained from induction motors show that the proposed system is capable of detecting induction motor faults.

칠드빔 유니트의 최적설계 및 성능평가 연구 (Study on Optimal Design and Performance Test of Chilled Beam Unit)

  • 김정엽;신현준;주상현;김지석
    • 한국유체기계학회 논문집
    • /
    • 제17권5호
    • /
    • pp.11-18
    • /
    • 2014
  • Chilled Beam system is the kind of water-air system which reduces the conveyance energy for air conditioning as well as allows efficient installation and comfortable indoor environment, and has been increasingly popular mainly in Europe. To effectively install such Chilled Beam system domestically, it is necessary to develop the product considering domestic climatic condition and the requirements for air conditioning system, and particularly the way to deal with condensation during operation of cooling system in summer shall be provided. In this study, the optimal design on induction structure of Chilled Beam unit was carried out through a numerical method, and the performance test for the prototype of unit was conducted in a real-scale experiment facilities of Chilled Beam unit. While the flowrate of 1st air is 101.3 CMH, the pressure in pressure chamber is 158.7 Pa and the cooling capacities of 1st air side and 2nd air side are 498.1 W and 709.5 W respectively.

IGBT 인버터구동 유도전동기의 회전자 편심 특성 해석 (Analysis of IGBT Inverter controlled Squirrel Cage Induction Motor during Eccentricity Rotor Motion)

  • 김미정;김병국;문지우;조윤현;황돈하;강동식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1055-1056
    • /
    • 2007
  • Asymmetric electro-magnetic force caused by the frictional worn bearing, rotor misalignment and unbalanced rotor etc. generates an asymmetrical operation, vibration and electro-magnetic noise. The need for detection of these rotor eccentricities has pushed the development of monitoring methods with increasing sensitivity and noise immunity. This paper is proposed the analysis method of the squirrel-cage induction motor driven by IGBT inverter using finite element method (FEM) and subroutine. The effect of the unbalanced magnetic pull in the inverter-fed induction motor which is in asymmetrical whirling motion is presented. The analysis results of rotor eccentricity could compare with motors which have been made normal air-gap motor and irregular air-gap motor and verify reliability. The simulation and experiment results can be useful for on-line faults detection monitoring system of induction motors.

  • PDF