• Title/Summary/Keyword: Air conditioner control

Search Result 182, Processing Time 0.026 seconds

Numerical Analysis of Thermal Environment Control in High-Density Data Center (고밀도 데이터센터의 열환경제어를 위한 수치해석)

  • Kwon, Oh-Kyung;Kim, Hyeon-Joong;Cha, Dong-An
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.821-828
    • /
    • 2012
  • Increasing heat generation in CPUs can hamper effective recirculation and by-pass because of the large temperature difference between the exhaust and the intake air through a server room. This increases the overall temperature inside a data center and decreases the efficiency of the data center's cooling system. The purpose of the data center's cooling system is to separate the intake and exhaust air by controlling the computer room air-conditioner(CRAC). In this study, ICEPAK is used to conduct a numerical analysis of a data center's cooling system. The temperature distribution and the entire room are analyzed for different volumetric flow rates. The optimized volumetric flow rate is found for each CPU power. The heat removal and temperature distribution for CPU powers of 100, 120, and 140 W are found to be the best for a volumetric flow rate of $0.15m^3/s$. The numerical analysis is verified through RTI indicators, and the results appear to be the most reliable when the RTI value is 81.

Design of particulate matter reduction algorithm by learning failure patterns of PHM-based air conditioning facilites

  • Park, Jeong In;Kang, Un Gu
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.7
    • /
    • pp.83-92
    • /
    • 2022
  • In this paper, we designed an algorithm that can control the state of PM by learning the chain failure pattern of PHM based air conditioning facility. It is an inevitable spread of PM due to the downtime caused by the failure of the air conditioning facility. The algorithm developed by us is to establish a PM management system through PHM, and it is an algorithm that maintains a constant stabilization state through learning the stop/operation pattern of the air conditioner and manages PM based on this. As a result of the simulating at a subway station for the performance qualification of the algorithm, it was verified that the concentration of PM reduces by 30% on average. In the case of stations with many passengers using the subway, the concentration of PM exceeded the Ministry of Environment Standards(100 ㎍/m3), but it was verified that the concentration of PM was improved at all stations where the simulation was conducted. In the future research is to expand the system to comprehensively manage not only PM but also pollutants such as CO2, CO, and NO2 in subway stations.

A Study of Dynamic Performance Improvement of Linear Compressors Using Phase Control Loop (리니어 컴프레서의 위상제어를 통한 동특성 향상에 관한 연구)

  • Nam, Jae-Woo;Oh, Joon-Tae;Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.3
    • /
    • pp.156-163
    • /
    • 2014
  • In this paper, a phase control system has been implemented to improve the dynamic performance of the stroke response for linear compressors. In order to control the cooling capability of a refrigerator or an air conditioner in which liner compressors are applied, the piston speed should be controlled. The piston speed control can be obtained by adjusting the frequency or the stroke of linear motors. The dynamic performance of linear compressors depends on how accurately the stroke or the piston amplitude is estimated. A phase control system is added to the stroke control loop and the superior performance of the phase control system is verified via some simulation studies.

Effect of Some Soil Conditioners on Soil Physical Properties and Tobacco Growth (토양개량제 시용이 토양물리성과 담배생육에 미치는 영향)

  • 이철환;진정의;한철수
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.6
    • /
    • pp.685-691
    • /
    • 1996
  • This experiment was conducted to investigate the effect of some soil conditioners, such as polyvinylalcohol(PVA), zeolite and perlite, on the changes of soil physical properties and on tobacco growth in paddy-upland rotated field. Soil conditioners were treated at the rates of 120kg in PVA, 500kg in zeolite and perlite per l0a, respectively. Ratio of soil aggregates formed from the treated plots tended to. be higher than those from the control in the order of PVA > perlite > zeolite. The wet aggregate stability, mean weight diameter, moisture retention and air permeability from the treated plots tended to be higher than those from the control. Amounts of water-stable aggregates of PV A-treated soil increased with higher soil moisture showing a peak at 50% of moisture content. But with respect to particle of size aggregate formed for crop growth and workability in field, it was presumed that 40% of soil moisture content would be most desirable. Visual characters of soil surface throughout the experiment clearly showed that treated soils were maintaining better surface roughness and porosity than control, but difference in water stable aggregates among treated plots tended to be narrowed. The growths of tobacco, espacially its root zone were better in conditioner treated plots than in non-treated plot showing best in PVA-treated soil.

  • PDF

Estimation of Domestic Greenhouse Gas Emission of Refrigeration and Air Conditioning Sector adapting 2006 IPCC GL Tier 2b Method (국내 냉동 및 냉방부문 온실가스 배출량 산정 - 2006 IPCC GL Tier 2b 적용 -)

  • Shin, Myung-Hwan;Lyu, Young-Sook;Seo, Kyoung-Ae;Lee, Sue-Been;Lim, Cheolsoo;Lee, Sukjo
    • Journal of Climate Change Research
    • /
    • v.3 no.2
    • /
    • pp.117-128
    • /
    • 2012
  • The Government of South Korea has continued its effort to fixate virtuous circle of economic growth and climate change response to cope with international demands and pressure to commitment for greenhouse gas reduction effectively. Nationally, Korean Government has established "Enforcement of the Framework Act on Low carbon, Green Growth"(2010. 4. 13) to implement national mid-term GHG mitigation goal(30% reduction by 2020 compare to BAU), which established the foundation for phased GHG mitigation by setting up the sectoral and industrial goal, adopting GHG and Energy Target Management System. Also, follow-up measures are taken such as planning and control of mid-term and short-term mitigation target by detailed analysis of potential mitigation of sector and industry, building up the infrastructure for periodic and systematic analysis of target management. Likewise, it is required to establish more accurate, reliable and detailed sectoral GHG inventory for successfully establishment and implement the frame act. In comparison to the $CO_2$ emission, Especially fluorinated greenhouse gases (HFCs, PFCs, $SF_6$) are lacking research to build the greenhouse gas inventories to identify emissions sources and collection of the applicable collection activities data. In this study, with the refrigeration and air conditioning sector being used to fluorine refrigerant(HFCs) as the center, greenhouse gas emission estimation methodology for evaluating the feasibility of using this methodology look over and mobile air conditioning, fixed air conditioning, household refrigeration equipment, commercial refrigeration equipment for the greenhouse gas emissions were calculated. First look at in terms of methodology, refrigeration and air conditioning sector GHG emissions in developing country-specific emission factors and activity data of the industrial sector the construction of the DB is not enough, it's 2006 IPCC Guidelines Tier 2a (emission factor approach) rather than the Tier 2b (mass balance approach) deems appropriate, and each detail by process, sectoral activity data more accurate, if DB is built Tier 2a (emission factor approach) can be applied will also be judged. Refrigeration and air conditioning sector in 2009 due to the use of refrigerant greenhouse gas emissions ($CO_2eq.$) assessment results, portable air conditioner 1,974,646 ton to year, fixed-mount air conditioner 1,011,754 ton to year, household refrigeration unit 4,396 ton to year, commercial refrigeration equipment 1,263 ton to year was estimated to total 2,992,037 tons.

Analysis of the Mechanical Behavior of Bellows for Electromagnetic Control Valve (전자기 제어 밸브를 위한 벨로우즈의 기계적 거동에 관한 연구)

  • Son, In-Seo;Hwang, Seon;Shin, Dong-Kil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.432-437
    • /
    • 2016
  • The behavior of a bellows for an electromagnetic control valve was investigated. The bellows consists of an outer metal bellows, inner spring, and metal caps. The bellows needs to have sensitive and precise motion against external loads and pressure loads in order to control the position of the valve accurately. The spring constant of the inner spring and load-displacement curve of the bellows set were measured using a test machine. The inner spring showed a linear relation between load and displacement. The bellows set showed small stiffness at small displacement, and then the stiffness slightly increased upon subsequent displacement. Based on the measured data, finite element analysis was performed. Axisymmetric conditions were applied, and shell elements were used. The effective material properties of the outer bellows material were extracted. Additional analysis was performed, and the behavior of the bellows was analyzed using the finite element model.

Recent Progress in Solar Energy Research - A review of Papers Published in the Korean Journal of Solar Energy between 2000 and 2002 - (태양에너지 분야의 최근 연구동향- 2000년$\sim$2002년 학회지 논문에 대한 종합적 고찰 -)

  • Yoo, Ho-Chun;Jang, Moon-Seok
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.107-119
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Solar Energy between 2000 and 2002 has been done. Focus has been put on current status of research in the aspect of Insolation. Solar Collector and Storage System, Solar Heating and Cooling System, Solar Cell and Lighting System, Active and Passive Solar Building, Heat Transfer in Solar Energy and Natural Energy. The conclusions are as follows. 1) Many studies on Insolation were conducted to optimize the usage of Solar Energy. 2) A review of the recent studies on solar thermal shows that there were many papers on solar collector and storage system. However, studies on the HVAC system using solar energy were relatively insufficient. 3) To produce high efficient solar cell. various experimental and numerical papers were published. However studies on control system, solar cell and lighting were seemed to be insufficient. 4) Studies on using solar energy in passive solar buildings were widely carried out, however, studies based on synthetic analysis of buildings and BIPV were insufficient. 5) Studies on heat transfer were mainly about heat exchanger, performance of heat pipe and multi air conditioner. 6) Studies on energy resources except for solar energy, such as hydraulic power and wind power etc. were very few.

Utilizing Under Voltage Load Shedding Strategy to Prevent Delayed Voltage Recovery Problem in Korean Power System

  • Lee, Yun-Hwan;Oh, Seung-Chan;Lee, Hwan-Ik;Park, Sang-Geon;Lee, Byong-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.60-67
    • /
    • 2018
  • The presence of induction motor loads in a power system may cause the phenomenon of delayed voltage recovery after the occurrence of a severe fault. A high proportion of induction motor loads in the power system can be a significant influence on the voltage stability of the system. This problem referred to as FIDVR(Fault Induced Delayed Voltage Recovery) is commonly caused by stall of small HVAC unit(Heating, Ventilation, and Air Conditioner) after transmission or distribution system failure. This delayed voltage recovery arises from the dynamic characteristics associated with the kinetic energy of the induction motor load. This paper proposes the UVLS (Under Voltage Load Shedding) control strategy for dealing with FIDVR. UVLS based schemes prevent voltage instability by shedding the load and can help avoid major economic losses due to wide-ranging cascading outages. This paper review recent topic about under voltage load shedding and compare decentralized load shedding scheme with conventional load shedding scheme. The load shedding strategy is applied to an actual system in order to verify the proposed FIDVR mitigation solution. Simulations demonstrate the effectiveness of the proposed method in resolving the problem of delayed voltage recovery in the Korean Power System.

Design and Implementation of Real-Time Information Appliance Control Simulator Based on TMO Scheme (TMO 스키마 기반의 실시간 정보가전 제어 시뮬레이터의 설계 및 구현)

  • Jung, Eun-Jae;Shin, Chang-Sun;Joo, Su-Chong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.05a
    • /
    • pp.149-152
    • /
    • 2003
  • 본 논문에서는 분산 실시간 서비스를 지원하는 TMO(Time-triggered Message-triggered Object) 객체를 기반으로 정보가전 기기들을 관리하기 위한 실시간 정보가전 제어 시뮬레이터를 설계 및 구현한다. TMO객체는 기존 객체를 확장한 실시간 특성을 자체적으로 가지는 객체를 UCI의 DREAM연구소에서 제안한 분산 실시간 객체이다. 이러한 TMO 객체를 기반으로 TMOSM(TMO Support Middelware) 상에서 실시간 정보가전 제어를 위한 TMO 객체들의 상호 동작과 실시간 속성을 설계하여 보장된 실시간 서비스를 지원하도록 한다. 본 시뮬레이션 모델은 온도제어, 조도제어, 방법제어 서비스를 지원하는 컴포넌트들로 구성된다. 온도제어 서비스를 위해 Fan_TMO와 Air_Conditioner_TMO, Heater_TMO가 상호 작용하여 적정 실내 온도를 유지하도록 하며, 조도제어 서비스를 위해 Light_TMO가 조도의 변화에 따라 동작하여 일상생활에 적당한 조명 환경을 제공한다. 또한 방범제어서비스를 위해 Camera_TMO가 정해진 시간을 주기적으로 동작하여 방범 활동을 수행한다. 그리고, 각각의 TMO 정보가전 객체들의 동작을 관리하고 서비스 수행 결과를 모니터링 하는 Home_Server_TMO가 존재한다. 마지막으로 설계된 시뮬레이션 환경을 구현하여 본 모델의 실시간 정보가전 제어 서비스를 정확하게 지원하는지를 검증한다. 제안한 시뮬레이션 환경은 일반 정보가전기기를 추가 작업 없이 실시간 서비스 지원 객체로 적용할 수 있는 모델이다.

  • PDF

A Study on Noise Identification of Compressor Based on Two Dimensional Complex Sound Intensity (Two Dimensional Complex Sound Intensity를 이용한 압축기 소음원 규명에 관한 연구)

  • 안병하;김영수
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.1
    • /
    • pp.83-92
    • /
    • 2000
  • Sound intensity method is well known as a visualization technique of sound field or sound propagation in noise control. Sound intensity or energy flux is a vector quantity which describes the amount and the direction of net flow of acoustic energy at a given position. Especially two dimensional sound intensity method is very useful in evaluating periodic characteristics and acoustic propagation mode of noise source. In this paper, we have studied the noise source Identification, acoustic sound field analysis, and characteristics of noise source of rotary compressor and scroll compressor for air conditioner using complex sound intensity method. Also we proposed a now method of time domain analysis which is used in evaluating of position of noise source in rotary and scroll compressor in this paper This paper presents the advantage, simplicity and economical efficiency of this method by analysing the characteristics of noise source with two dimensional complex sound intensity simultaneously.

  • PDF