• 제목/요약/키워드: Air change rate

검색결과 766건 처리시간 0.029초

${\cdot}$출구 위치 변화에 따른 압전 구동방식 마이크로 펌프의 성능특성에 관한 수치해석적 연구 (A Numerical Study on the Performance Characteristics of a Piezoelectric Micropump for Different Inlet and Outlet Positions)

  • 김동희;정진;김창녕
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.33-38
    • /
    • 2005
  • This study has been conducted to investigate flow characteristics of a micropump with piezoelectric materials. In this study, the change of flow rates has been investigated for different positions of the inlet and outlet and for different distances between them. The FSI(Fluid Structure Interaction) method has been employed for numerical analysis of the piezoelectric diffuser/nozzle based micropump. It has been found that time averaged flow rate is greater in the case that distance between the inlet and outlet is longer. For the cases where the positions of the inlet are different with the position of the fixed outlet at the center, the flow rate is increased as the inlet is located farther from the center. This study may supply fundamental understandings for the design and analysis of the prototypes of piezoelectric micropumps.

Capacity Modulation of an Inverter Driven Heat Pump with Expansion Devices

  • Lee, Yong-Taek;Kim, Yong-Chan;Park, Youn-Cheol;Kim, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.60-68
    • /
    • 2000
  • An experimental study was peformed to investigate characteristics of an inverter driven heat pump system with a variation of compressor frequency and expansion device. The compressor frequency varied from 30Hz to 75Hz, and the performance of the system ap-plying three different expansion devices such as capillary tube, thermostatic expansion valve(TXV), and electronic expansion valve (EEV) was measured. The load conditions were altered by varying the temperatures of the secondary fluid entering condenser and evaporator with a constant flow rate. When the test condition was deviated from the standard value(rated value), TXV and EEV showed better performance than capillary tube due to optimal control of mass flow rate and superheat. In the present study, it was observed that the variable area expansion device had better performance than constant area expansion device in the inverter heat pump system due to active control of flow area with a change of com-pressor frequency and load conditions.

  • PDF

실내·외 블라인드의 Slat 반사율에 따라 창호 일사투과량 및 그에 따른 벽체 대류열획득량 분석 (A Study on Change in Window Transmitted Solar and the Resultant Wall Surface Convective Heat Gain with Regard to Slat Reflectance of External and Internal Blinds)

  • 현인탁;이재호;윤여범;이광호
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.565-571
    • /
    • 2014
  • Nowadays, to make buildings light weight and aesthetically pleasing, curtain wall structure are commonly used. Therefore, window to wall ratio is increasing, which has caused cooling and heating load in crease in buildings as well. This phenomenon has negative impact from energy point of view. This paper analyzes window and wall convective heat gain when the slat reflectance of external and internal blinds are changed for the better understanding of the fundamentals behind the phenomena. It was observed that, if slat reflectance is increased, window transmitted solar increases and convection heat rate is clearly affected. Among six surfaces including four walls, ceiling and floor, maximum convection heat rate occurs on the south wall in summer. On the other hand, ceiling and floor showed the lowest convection heat gain, since they are shared by adjacent floors.

3단압축 드라이아이스 제조사이클의 압축동력과 엑서지 해석 (Compression Power and Exergy Analysis in a Dry Ice Production Cycle with 3-stage Compression)

  • 이근식
    • 설비공학논문집
    • /
    • 제12권6호
    • /
    • pp.550-560
    • /
    • 2000
  • In order to minimize compression power and analyze the cause of exergy loss for a dry ice production cycle with 3-stage compression, the variation of compression power was investigated and the exergy analysis was peformed for the cycle. In this cycle, $CO_2$, is used both as a refrigerant and as a raw material for dry ice. The behavior of compression power and irreversibility in the cycle were examined as a function of intermediate pressure. From this result, the conditions for the minimum compression power were obtained in terms of the first stage or the third stage pressure. In addition, the irreversibilities for the cycle were investigated with respect to the efficiency of compressor. Result shows that the optimum pressure is not consistent with the conventional pressure obtained from the equal-pressure-ratio assumption. This is mainly due to the change in mass flow rate of the intermediate stage compressor by the flash gas evaporation from the flash drums. Most important is that the present exergy analysis enabled us to find bad performance components for the cycle and informed us of methods to improve the cycle performance.

  • PDF

승용차 공조계용 블로우어의 음향출력 평가에 관한 연구 (A Study on the Acoustic Power Estimation in the Blower for a Vehicle Air-handling System)

  • 김석현;유성우
    • 산업기술연구
    • /
    • 제17권
    • /
    • pp.87-93
    • /
    • 1997
  • A Special purpose program, based on the dimensional analysis, was developed to estimate the wide band turbulent noise in the blower of vehicle airhandling system. Acoustic power level was measured at 4 rating points around the operating condition. The experiment was performed on the reference blower model using international standard chamber, which could measure acoustic power according to the air-handling performance. Analytical model of the blower noise was determined by the measured data. Using the analytical acoustic model, it was possible to estimated the effect by the change of the operating condition, such as flow rate, static pressure and wheel rotating speed, furthermore, the diameter and the width of blower.

  • PDF

표고버섯의 건조 특성 및 주요성분의 변화 1. 건조특성 및 건조모델 (Drying Characteristics and Content Change of Major Components of Shiitake Mushroom (Lentinus erodes) 1. Drying Characteristics and Drying Model)

  • 최병민;서재신;최주호
    • 한국식품저장유통학회지
    • /
    • 제4권3호
    • /
    • pp.271-278
    • /
    • 1997
  • Drying of Shiitake mushroom was investigated to see the effect of temperature, relative humidity of drying air and diameter of the pileus on its rates. The drying rate was increased with the increase of the air temperature and the decrease of the relative humidity. The external color was dark brown at higher drying temperature and higher relative humidity. Exponential and Thompson nodel were found to describe well the raying process of the Shiitake mushroom.

  • PDF

Web기반을 활용한 자재 조달 시스템 개선방안 (A Study on the system Applied Air-Vent to Complex Lay Poly-Urethane Waterproofing Material and Air-Permeability Buffer Sheet of Disconnection Type)

  • 이임배;김홍현;윤수원;민경석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.141-145
    • /
    • 2008
  • Because of world financial crisis, The Korea domestic construction industry has been damaged hugely on material supplying work. A current domestic material supply system can't react properly on a great rise of foreign exchange rate and raw material price, so the system has a problem which is not properly supplying material. To solve this problem, a more innovative material supply work system is seriously needed than ever. So this study wants to improve material supply system for supplying material right time, right place through applying a web-based system. Applying this, overall process of material-supply-work can be done on a web-based system for immediately understanding change of ordering and warehousing by material-supply-schedule to a domestic construction field.

  • PDF

T.M.C.P. 강의 부식피로거동에 미치는 염분의 영향에 관한 연구 (The Study on the Influence of the Concentration NaCl Solution on Corrosion Fatigue Behavior of T.M.C.P. Steel)

  • 이상호;한정섭
    • 한국해양공학회지
    • /
    • 제7권2호
    • /
    • pp.131-140
    • /
    • 1993
  • To study the corrosion fatigue begavior of T.M.C.P. steel, the rotary bending fatigue test with the change of concentration of NaCl solution was carried out. Fatigue life in the corrosion environment is decreased markedly in comparision with that in the air. Fatigue limit in the air was about 225 MPa. In case of 3.5% NaCl solution fatigue life could be expressed as .sigma./sub f/=10,392 * (N/sub f/)/sup -o.2923 . According to the paris's rule, crack growth rates could be expressed as da/dN=2.62.*10/sup -7/ .DELTA. K/sup 1.09/(3.5% NaCl solution), da/dN=1.95 *10/sup -7 .DELTA. K/sup 1.05/(1% NaCl solution), da/dN=2.62 * 10/sup -7/.DELTA./sup 0.72/(0.01% NaCl solution) with da/dN expressed in mm/cycle and .DELTA.K in MPa.GAMMA.m. The crack growth rate in the corrosion environment was highest under 3.5% NaCl solution.

  • PDF

면섬유 및 한지섬유의 자연염색 및 기능성광물처리에 의한 쾌적성의 변화 (The Change of Comfort Properties of Cotton and Hanjee Fabrics with Natural Dyeing and Functional Mineral Treatment)

  • 김성희
    • 한국의류산업학회지
    • /
    • 제12권2호
    • /
    • pp.219-223
    • /
    • 2010
  • In this study, the comfort properties of cotton and Hanjee fabrics dyed with Inonotus obliquus and treated with illite were evaluated and compared. Results were as follows; 1) W/T values and WC/W values of cotton and Hanjee fabrics were decreased when they were dyed with Inonotus obliquus and treated with illite. 2) Although air permeability of cotton fabrics was higher than that of Hanjee fabrics, air permeability of cotton and Hanjee fabrics dyed with Inonotus obliquus and treated with illite was decreased. 3) Thermal conductivity of cotton and Hanjee fabrics dyed with Inonotus obliquus was increased whereas thermal retain property was decreased. 4) Water absorption of Hanjee fabrics was higher than that of cotton fabrics. Water absorption of cotton and Hanjee fabrics dyed with Inonotus obliquus and treated with illite was increased. 5) Deodorization rate of Hanjee fabrics was greater than that of cotton fabrics.

기포 캐비테이션의 거동 해석 및 수중익 캐비테이션의 소음 제어 (Analysis of bubble cavitation and control of cavitation noise of hydrofoils)

  • 강관형;안종우;송인행;김기섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.335-341
    • /
    • 2001
  • The bubble cavitation and cloud cavitation are the major sources of cavitation-induced sound and vibration. A numerical method which predicts the trajectory and volume change of a cavity is developed, to predict the cavitation noise of a body. It is shown, by using the numerical method, that the cavitation inception and events rate is strongly dependent on the screening effect caused by the pressure gradient around a body, which is confirmed experimentally. Additionally, the effectiveness of a cavitation control method utilizing air injection is investigated experimentally. It is demonstrated that the noise level of the cloud cavitation can be significantly reduced by the air-injection method.

  • PDF