• Title/Summary/Keyword: Air Trap

Search Result 90, Processing Time 0.033 seconds

Development of Mosquito Trap with Effect of Air Cleaning by Using Theory of lnventive Problem Solving (TRIZ) (창의적 문제 해결이론 (TRIZ, 트리즈)를 이용한 공기 정화 기능의 모기 유인 퇴치기 개발)

  • Lee, Kyeong-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.6
    • /
    • pp.155-159
    • /
    • 2002
  • This paper describes the development process of mosquito trap with the effect of air cleaning by using the substance-field analysis and evolution pattern of systems in the theory of inventive problem solving (TRIZ). We g(It the concept of the mosquito trap with mosquito attractants instead of mosquito reluctants such as mosquito stick coil and skin medicine with bad and toxic smell. The number of mosquitos traped by one trap near cattle shed per one night in summer, was over 10 thousands with some effects of air cleaning

Development of Mosquito Trap with Effect of Air Cleaning by Using Theory of Inventive Problem Solving (TRIZ) (창의적 문제 해결이론 (TRIZ, 트리즈)를 이용한 공기 정화 기능의 모기 유인 퇴치기 개발)

  • 이경원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.556-559
    • /
    • 1997
  • This paper describes the development process of mosquito trap with the effect of air cleaning by using the substance-field analysis and evolution pattern of systems in the theory of inventive problem solving (TRIZ). By the concept of standard solution about introducing S3 substance, modification of S1 (human) and S2 (mosquito) between first substance SI and second substance S2 with harmful effect, we got the concept of the mosquito trap with mosquito attractants instead of mosquito reluctants such as mosquito stick coil and skin medicine w~th bad and toxic smell. The number of mosquitos traped by one trap near cattle shed per one n~ght in summer, was over 10 thousands with some effects of air cleaning.

  • PDF

Thermal Structural Analysis of Steam Trap Bimetal Valve (스팀 트랩 바이메탈 밸브의 열 구조해석)

  • Kim, Dong Hwan;Kim, Dong Hyun;Ryu, Gyeong Joong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.11
    • /
    • pp.799-805
    • /
    • 2012
  • In this study, structural thermal analyses for steam trap valve considering contact boundary condition have been conducted for high temperature and pressure conditions using nonlinear finite element method. Full steam trap model also including regulator and housing structures is considered in order to accurately simulate the complex valve mechanism and investigate thermal stress levels, and structural behaviors of core structural parts. It is typically shown that the present computational approach can give very useful results for design engineers so that the operating performance and structural safety of the steam trap valve can be verified in the design process.

A Study on the Comparison of Measuring Methods and Development of Emssion Factor on Mercury from Large-Scale Emission Sources (대형배출원에서의 수은 측정방법 비교 및 배출계수 개발에 관한 연구)

  • Kim, Hyung-Chun;Kim, Rhok-Ho;Kim, Jong-Hyeon;Lim, Seung-young;Kang, Dae-Il;Hong, Ji-Hyung;Jang, Kee-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.2
    • /
    • pp.184-192
    • /
    • 2016
  • Recently, studies on reducing mercury have been actively conducted worldwide, which include the current status of mercury emissions and mercury control technology. Among the control technology, Sorbent Trap measurement method has been aggressively developed due to its reliability, easiness in measurement and analysis. The purpose of this study is to evaluate the applicability of the new international measurement method; Sorbent Trap. For this, the study compared the Sorbent trap method (US EPA Method 30B) and the Korean Standard Method for Examination of Air (ES 01408.1) to evaluate their reliability, and developed mercury emission factors. As the result, the relative standard deviations (% RSD) of the two methods were 3.5~13.4% at Coal-fired Power Plants (CPP), 4.0~18.4% at Cement Kilns (CK), and 3.0~11.3% at Medical Waste Incinerators (MWI). The emissions factors were developed as 14.50 kg/ton at CPP, 45.10 kg/ton at CK, and 1,290.2 kg/ton at MWI.

Effect of Air Exposure on ZnO Thin Film for Electron Transport Layer of Quantum Dot Light-Emitting Diode (ZnO 박막 전자수송층의 공기 노출에 의한 양자점 발광다이오드의 특성 변화)

  • Eunyong Seo;Kyungjae Lee;Jeong Ha Hwang;Dong Hyun Kim;Jaehoon Lim;Donggu Lee
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.455-461
    • /
    • 2023
  • We investigated the electrical characteristics of ZnO nanoparticles (NPs) with air exposure that is a widely used electron transport layer for quantum dot light-emitting diodes (QLEDs). Upon air exposure, we observed changes in the density of states (DOS) of the trap levels of ZnO NPs. In particular, with air exposure, the concentration of deep trap energy levels in ZnO NPs decreased and electron mobility significantly improved. Consequently, the air-exposed ZnO reduced leakage current by approximately one order of magnitude and enhanced the external quantum efficiency at the low driving voltage region of the QLED. In addition, based on the excellent conductivity properties, high-brightness QLEDs could be achieved.

A Study on Combustion Characteristics of Pre-mixed $CH_4$-air by Flame Trap (플레임트랩에 의한 메탄-공기 예혼합기의 연소특성에 관한 연구)

  • Kim, Deok-Ho;Lee, Jai-Hyo;Choi, Su-Jin;Cho, Gyu-Back;Jeong, Dong-Soo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.2
    • /
    • pp.22-28
    • /
    • 2005
  • Exhaust gas emissions from internal combustion engines are one of the major sources of air pollution. And, it is extremely difficult to increase gasoline engine efficiency and to reduce $NO_X$ and PM(particulate matter) simultaneously in diesel combustion. This paper offers some basic concepts to overcome the above problems. To solve the problems, a recommended technique is CAI(controlled auto-ignition) combustion. In this paper, a flame trap was used to simulate internal EGR(exhaust gas recirculation) effect. An experimental study was carried out to find combustion characteristics using homogeneous premixed gas mixture in the constant volume combustion chamber(CVCC). Flame propagation photos and pressure signals were acquired to verify the flame trap effect. The flame trap creates high speed burned gas jet. It achieves higher flame propagation speed and more stable combustion due to the effect of geometry and burned gas jet.

Efficiency Evaluation of Nozawa-Style Black Light Trap for Control of Anopheline Mosquitoes

  • Lee, Hee-Il;Seo, Bo-Youl;Shin, E-Hyun;Burkett, Douglas A.;Lee, Jong-Koo;Shin, Young-Hack
    • Parasites, Hosts and Diseases
    • /
    • v.47 no.2
    • /
    • pp.159-165
    • /
    • 2009
  • House-residual spraying and insecticide-treated bed nets have achieved some success in controlling anthropophilic and endophagic vectors. However, these methods have relatively low efficacy in Korea because Anopheles sinensis, the primary malaria vector, is highly zoophilic and exophilic. So, we focused our vector control efforts within livestock enclosures using ultraviolet black light traps as a mechanical control measure. We found that black light traps captured significantly more mosquitoes at 2 and 2.5 m above the ground (P<0.05). We also evaluated the effectiveness of trap spacing within the livestock enclosure. In general, traps spaced between 4 and 7m apart captured mosquitoes more efficiently than those spaced closer together (P>0.05). Based on these findings, we concluded that each black light trap in the livestock enclosures killed 7,586 female mosquitoes per trap per night during the peak mosquito season (July-August). In May-August 2003, additional concurrent field trials were conducted in Ganghwa county. We got 74.9% reduction (P<0.05) of An. sinensis in human dwellings and 61.5% reduction (P>0.05) in the livestock enclosures. The black light trap operation in the livestock enclosures proved to be an effective control method and should be incorporated into existing control strategies in developed countries.

Hydrogen Peroxide Concentrations in Air in Seoul (서울시 대기 중 $H_2O_2$의 농도)

  • 강충민;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.61-68
    • /
    • 2000
  • Gas-phase hydrogen peroxide(H2O2) concentrations were measured to investigate it's distribution in the ambient air in downtown Seoul(Kwanghwamum and Mullae-dong). These measurements were made during four season, from April 30, 1998 to January 29, 1999, using Cold Trap and HPLC. Measurements were also made of other photochemical oxidants and trace gases(O3, NO2, CO and SO2) and meteorological parameters(relative humidity, temperature, solar radiation and wind speed). The mean of all observations was 0.10 ppbv and the range measured was below the level of detection(>0.01 ppbv) to 0.47ppbv. The higher seasonal mean concentrations showed during the summer(0.21 ppbv) and concentrations of H2O2 showed a diurnal variation with maximum concentrations in the afternoon(12:30∼14:00). The results from the corrrelation analysis showed that the concentration of gaseous H2O2 is strongly dependent on the other air pollutants(NO2, CO and O3) and meteorological parameters(relative humidity, temperature and solar radiation.)

  • PDF