• 제목/요약/키워드: Air Conditioning Unit

검색결과 378건 처리시간 0.021초

3관식 시스템 히트펌프의 충전량 변화에 따른 성능 특성에 관한 연구 (The performance of a heat pump with 3-piping system at various charging conditions)

  • 송인식;최종민;주영주;정현준;강훈;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.288-293
    • /
    • 2008
  • The cooling load in winter is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a multi-heat pump with 3-piping system was investigated as a function of refrigerant charge and its performance was analyzed in cooling mode, heating mode, and heat recovery mode. COP in the heating or cooling mode showed little dependence on refrigerant charge at overcharge conditions, while those were strongly dependent on refrigerant charge at undercharge conditions and outdoor inlet temperature. In the heat recovery mode, the performance of the system was very sensitive to charge amount at all conditions. Optimum charge amount in the heat recovery mode was 14% lower than that in the cooling mode at the standard condition because the refrigerant only passed the indoor units. It is required to store the excessive refrigerant charge in a storage tank to optimize the system performance at operating modes.

  • PDF

중앙난방방식을 지역난방.소형열병합난방방식으로 전환시의 경제성 비교 분석 (Analysis for the Economic efficiency of District Heating and Gas Engine Co-generation System comparing with Central Heating System)

  • 김규생;이상혁;홍경표;원영재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.459-465
    • /
    • 2007
  • This study was conducted to calculate the LCC of a apartment complex with a type of heating system, district heating and cogeneration system. For the purpose of analyzing LCC according to size of apartment complex, 500, 1,500 and 4,000 houses of model apartment selected. This research performs design of heating system and the life cycle cost analysis including an initial cost, energy cost, maintenance and operation cost, replacement cost and renovation cost during the project period(15years). According to the calculated results, 1) Initial cost of cogeneration system with 500, 1500 and 4000 houses is higher than district heating system each of 20%, 13%, 12%. 2) In case of cogeneration system, the payback period by electric generation is 5.21, 4.92 and 4.47 years and saving cost was calculated 29 billion won, 94 billion won and 262 billion won after payback period. 3) Cogeneration system LCC was 1.12, 1.07 and 1.06 times larger than district system with the size of apartment complex. According to the case of this study district heating system is more efficient than cogeneration system in terms of the reduction of LCC. 4) Gas Engine Co-generation System is more efficient than other systems because it can collect progressive part from electric charge progressive stage system. However, the efficiency is decreasing because of raising of fuel bills(LNG) and lowering of power rate for house use. Especially the engine is foreign-made so the cost of maintenance and repair is high and the technical expert is short. 5) District heating is also affected by fuel bills so we should improve energy efficiency through recovering of waste heat(incineration heat, etc.). Also, we should supply district cooling on the pattern of heat using of let the temperature high in winter and low in summer.

  • PDF

해양플랜트 HVAC 시스템용 플레이트·쉘 타입 증발기에 관한 연구 (A Study on Plate & Shell type Evaporator in HVAC System for Offshore Plant)

  • 박재홍
    • 한국가스학회지
    • /
    • 제24권1호
    • /
    • pp.33-40
    • /
    • 2020
  • 해양플랜트용 HVAC(Heating Ventilation and Air-Conditioning) 시스템의 컨덴싱 유닛(condensing unit)의 경우, DX(Direct Expansion) 코일보다는 온도 안정성이 뛰어난 칠러 시스템(chiller system)을 주로 사용하고 있다. 칠러시스템의 구성품 중 대형 냉매압축기와 전자식 팽창밸브 등은 대부분 수입되고 있다. 이에 칠러 시스템의 크기는 국내에서 제작되는 열교환기(증발기, 응축기)에 의해 좌우된다. 현재 갈수록 심화되고 있는 사용공간의 제한으로 인해 선주사 및 조선소에서는 장비 크기를 컴팩트하게 해줄 것을 메이커에 지속적으로 요구하고 있다. 이에 본 논문에서는 해양플랜트에서 만액식(flooded) 칠러 시스템의 증발기로 주로 사용되고 있는 쉘-튜브형 열교환기를 컴팩트한 플레이트-쉘 열교환기로 대체하기 위한 주요개발과정을 소개하고, 이와 함께 개발된 플레이트-쉘 열교환기를 실제 증발기로 적용한 만액식 칠러 시스템을 제작하여 그 성능을 실험적으로 평가하였으며 그 결과를 제공하고자 한다.

화학축냉용 무기염들의 수화반응 및 열 및 물질전달 향상방안 (Study of Hydration Reaction Characteristics of Inorganic Salts for Chemical Cold Storage and Method of Enhancement of Heat and Mass Transfer)

  • 김상욱;한종훈;황용준;이건홍
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 춘계 학술발표회 논문집
    • /
    • pp.185-191
    • /
    • 1999
  • An air-conditioning system based on the chemical heat storage principle was considered. $H_2O$ was chosen as the reaction gas and the working fluid as well. Na$_2$S, CaCl$_2$, MnCl$_2$, BaCl$_2$, MgCl$_2$, Fe$_2$(SO$_4$)$_3$ and MnSO$_4$ were tested as the solid reactants by using Cahn pressure balance. Na$_2$S was superior to other salts in respect of high capability of absorption of water gas, 5 moles of $H_2O$ per unit mole of Na$_2$S, and adequate temperature of adsorption, $65^{\circ}C$ at 7torr, and of desorption, 13$0^{\circ}C$ at 76torr. Clausius-Clapeyron diagram of Na$_2$S was obtained via adsorption experiments at several vapor pressures of water gas. To enhance heat and mass transfer characteristics, usually below 1W/m K, of the reactor bed of general adsorption systems, expanded graphite block was adapted as the support of Na$_2$S salt. Expanded graphite blocks had thermal conductivity values of 20~80W/mK with respect to 100~400kg/㎥ of block bulk density. Permeability values of expanded graphite blocks were 10$^{-13}$ ~ 10$^{-14}$ $m^2$ with respect to 100~300kg/㎥ of block bulk density showing highly decreasing values of permeability, below 10$^{-l4}$$m^2$, in the range of above 150kg/㎥ of block bulk density.y.

  • PDF

컨테이너 패키지형 그린수소 수전해 생산 시스템의 수소 누출 특성에 관한 환기 성능 연구 (Ventilation Performance Study on Hydrogen Leakage Characteristics of Container Packaged Water Electrolysis Production System)

  • 권수인;진병석;이치우;엄성용;최경민
    • 한국수소및신에너지학회논문집
    • /
    • 제35권3호
    • /
    • pp.324-335
    • /
    • 2024
  • The container package type sealed water electrolysis production system installs mechanical balance of plant and electrical balance of plant as an integrated unit to enable independent operation within the package module. The auxiliary equipment required to operate the water electrolysis system must be integrated to reduce the installation area and shorten the installation time. At this time, as leak risk factors are placed in a dense space, when a hydrogen gas leak accident occurs, it can have a mutual influence on other adjacent facilities, so it contains various risk factors. In this study, when a gas leak occurs in a container packaged water electrolysis system, possible sources of leakage in the system according to the KS C IEC 60079-10-1:2015 and KGS GC101 standards were identified, and the leak rate and leak characteristics were calculated. did. The hazardous area and its range were calculated according to ventilation and dilution characteristics. In order to optimize ventilation characteristics, design of experiment was used to analyze the influence to evaluate the adequacy of ventilation, and overseas ventilation standards were analyzed and compared. In addition, the optimal ventilation structure and characteristics of the container packaged water electrolysis system were presented according to the results of the experimental design method.

슬러리 양돈분뇨의 최적 고액분리 방안 연구 (A Practical Study on the Solid-Liquid Separation of the Swine Wastewater from Slurry Feedlot)

  • 박성균;최재길;정윤진
    • 유기물자원화
    • /
    • 제8권2호
    • /
    • pp.60-70
    • /
    • 2000
  • 현재 국내에서 처리에 어려움을 겪고 있으며 사회적으로 문제가 되고 있는 양돈 분뇨의 처리중 생물학적 처리를 위한 전처리 공정의 일환으로 비육돈 슬러리 돈사에서 발생하는 분뇨를 대상으로 고액분리에 관한 연구를 수행하였다. 최적의 고액 분리를 위하여 적정 응집제 선정 및 첨가량을 도출하였으며, 현장 규모의 고액 분리 장치를 통하여 규모별 최적 고액 분리 공정을 도출하였다. 이 결과 탈수성 개량을 위한 적정 응집제로는 Polyarcylamide 계열의 양이온 고분자 응집제인 E-851이 적합하였으며, 단위 고형물당 0.24~0.6%가 요구되었다. 본 연구에서 검토된 공정으로는 Mesh Screen, Drum Screen, Cyclone Drum Filter, Screw Press, 고속 Screw Decanter, 저속 Screw Decanter 및 DAF 공정을 조합하여 검토하였다. 그 결과 최적 공정으로는 중 소규모의 1차 고액 분리 공정으로는 Screw Press(응집제 첨가)와 대규모 및 공공처리장 규모에서는 저속 Screw Decanter(응집제 첨가)가 적정 공정으로 도출되었으며 2차 처리 공정으로는 가압부상조가 가장 안정적인 것으로 나타났다. 한편 고액 분리 유무에 따라 수분조절제 및 유기물 부하량 감소는 각각 94.8, 84.7%로 나타났으며 슬러리 양돈분뇨의 정화방안으로는 고액분리가 반드시 필요한 것으로 나타났다.

  • PDF

순환 유동층 보일러와 초초임계 증기 사이클을 이용한 500 MWe급 순산소 화력발전소의 건식 재순환 흐름의 열 교환 및 경제성 분석 (Heat Integration and Economic Analysis of Dry Flue Gas Recirculation in a 500 MWe Oxy-coal Circulating Fluidized-bed (CFB) Power Plant with Ultra-supercritical Steam Cycle)

  • 김세미;임영일
    • Korean Chemical Engineering Research
    • /
    • 제59권1호
    • /
    • pp.60-67
    • /
    • 2021
  • 본 연구에서는 CO2 포집을 포함하는 500 MWe 급 전기를 생산하는 순산소 석탄화력발전소에 대한 공정흐름도를 제시하였고, 기술경제성 평가를 수행하였다. 이 석탄화력발전소는 순환 유동층 보일러(CFB), 초초 임계 증기 사이클 증기 터빈, 보일러에서 배출되는 배기가스내 수분과 오염물질을 제거하는 배기가스 정제 장치(FGC), 산소 분리 초저온 공정(ASU), 이산화탄소를 분리하는 극저온 공정(CPU)을 포함한다. 건식 배기가스 재순환(FGR)은 CFB연소기내 온도 제어와 고농도 CO2 배출을 위하여 사용되었다. 이 순산소 석탄화력발전소의 열효율을 증가시키기 위하여 FGR 흐름에 대한 열교환, ASU에서 배출되는 질소 흐름에 대한 열교환, 그리고 CPU 내 기체 압축기의 열 회수를 고려하였다. FGR열교환기의 온도차(ΔT)의 감소는 배기가스의 더 많은 폐열 회수를 의미하며, 전기 및 엑서지 효율을 증가시켰다. FGR열교환기의 ΔT가 10 ℃ 에서 FGR과 FGC 주변의 연간 비용이 최소가 되었다. 이때, 전기 효율은 39%, 총투자비는 1371 M$, 총생산비용은 90 M$, 그리고 투자수익률은 7%/y, 그리고 투자회수기간은 12년으로 예측되었다. 본 연구를 통하여 순산소 석탄화력발전소의 열효율 향상을 위한 열교환망이 제시되었고, FGR 열교환기의 최적 운전 조건이 도출되었다.

기온과 특수일 효과를 고려하여 시계열 모형을 활용한 일별 최대 전력 수요 예측 연구 (Forecasting daily peak load by time series model with temperature and special days effect)

  • 이진영;김삼용
    • 응용통계연구
    • /
    • 제32권1호
    • /
    • pp.161-171
    • /
    • 2019
  • 일별 최대전력 수요 예측은 국가의 전력 수급운영에 중요한 과제로서 과거부터 다양한 방법들이 끊임없이 연구되어 왔다. 일별 최대전력 수요를 정확히 예측함으로써 발전설비에 대한 일일 운용계획을 작성하고 효율적인 설비 운용을 통해 불필요한 에너지 자원의 소비를 감소하는데 기여할 수 있으며 여름 겨울철 냉난방수요로 인해 발생하는 전력소비 과다로 인한 전력예비율 감소 문제 등에 선제적으로 대비할 수 있는 장점을 가진다. 이러한 일별 최대전력수요 예측을 위하여 본 논문에서는 Seasonal ARIMA, TBATS, Seasonal Reg-ARIMA, NNETAR 모형에 평일, 주말, 특수일에 대한 효과와 온도에 대한 영향을 함께 고려하여 다음날의 일별 최대전력을 예측하는 모형을 연구하였다. 본 논문을 통한 모형들의 예측 성능 평가 결과 요일, 온도를 고려할 수 있는 Seasonal Reg-ARIMA 모형과 NNETAR 모형이 이를 고려할 수 없는 다른 시계열 모형보다 우수한 예측 성능을 나타내었고 그 중 인공신경망을 활용한 NNETAR 모형의 예측 성능이 가장 우수하였다.