• 제목/요약/키워드: Air Condensation

검색결과 440건 처리시간 0.023초

탄화수소계 냉매의 응축 압력강하에 관한 연구 (Study on Condensing Pressure Drop of Hydrocarbon Refrigerants)

  • 김재돌;최준혁;정석권;윤정인;이호생
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.218-224
    • /
    • 2006
  • Experimental results for pressure gradient of HCs refrigerants R-290. R-600a. R-1270 and HCFC refrigerant R-22 during condensing inside horizontal double pipe heat exchangers are presented. The test sections which have the tube inner diameter of 10.98mm. and the tube inner diameter of 8mm are used for this investigation. Hydrocarbon refrigerants have higher pressure drop than R-22 in both test sections with the diameters of 12.70mm and 9.52mm. Pressure drop increased with the increase of the mass flux. These results form the investigation can be used in the design of heat transfer exchanger using hydrocarbons as the refrigerant for the air-conditioning systems

무궁화 객차 HVAC 열유동 특성 해석 (Numerical Analysis on HVAC Characteristics of Mugunghwa Passenger Car)

  • 남성원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.514-520
    • /
    • 2000
  • Numerical simulation is conducted to clarify the heat transfer and fluid flow characteristics of HVAC(Heating, Ventilating and Air-Conditioning) for Mugunghwa passenger car. The HVAC system is installed under the floor of carbody. This new HVAC system has a lot of merits in respect of the center of gravity of carbody, flow induced noise and reduction of condensation water etc. The standard k-epsilon turbulent model and SIMPLEC algorithm based on finite volume method are used to solve the physical HVAC model. To assure convergence, QUICK scheme for momentum equation and the first order upwind scheme for turbulent equations are used. From the results of simulation, the temperature and velocity magnitude are also distributed uniformly in the interior of car.

  • PDF

고무 발포 배관 보온 단열재의 성능 기준 및 평가 (Performance Standards and Evaluation of Elastomeric Flexible Cellular Insulation)

  • 전현석;최현중;최경석;강재식;이승언;정광섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.614-617
    • /
    • 2009
  • Elastomeric Flexible Cellular Insulation is widely used in construction fields to prevent condensation and frozen pipes, reduce energy, and improve insulation. However, when Elastomeric Flexible Cellular Insulation has been installed in buildings in Korea, there was no standardization, which resulted in heat loss Therefore, insulation design standards need to be developed and from these standards, pipe insulation should be improved to increase its efficiency. This study estimates temperature and surface-emissivity according to the thickness of insulation to evaluate thermal performance.

  • PDF

자연순환형 소형 진공증발농축장치 시뮬레이션 (Simulation of a natural circulation evaporative concentrator)

  • 박지훈;김내현;최용민;오왕규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1283-1287
    • /
    • 2009
  • In this study, an analysis was performed on an evaporative steam generator (concentrator), where natural circulation convective boiling occurs on tube-side by condensing hot steam on shell-side. Existing correlations on two-phase pressure drop, boiling or condensation heat transfer were used for the analysis. The effect of number of tubes, tube length, etc. on thermal performance was investigated. Simulation results reveal that steam generation rate increases almost proportionally to the tube length, or number of tubes. It is also shown that water circulation rate decreases as tube length increases.

  • PDF

외기온도와 부하변화에 따른 산업용 냉각기의 인버터제어 특성 (The Characteristic of Inverter Control by Variation of Refrigeration Load and Outdoor Temperature on Industrial Cooler)

  • 백승문
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.150-155
    • /
    • 2014
  • This paper presents The performance analysis of inverter control type-industrial cooler with respect to refrigeration load and outdoor temperature. Aside from materials about simulations and foundation data regarding inverter control compressors, currently, data about commercial coolers with inverter control still lack information for performance comparison. Thus, in this paper, the experiments are done to see characteristics of condensation capacity, evaporation capacity, compressor power and COP with respect to outdoor temperature and load by using a commercial inverter control cooler model. As a result, COP difference of the inverter control cooler with respect to load is 30% at the outdoor temperature of $35^{\circ}C$, 29% at the outdoor temperature of $30^{\circ}C$, 34% at $25^{\circ}C$, respectively.

발수가공 데이터의 분산분석 (ANOVA for Water Repellent Finish data)

  • 윤중범
    • 품질경영학회지
    • /
    • 제16권1호
    • /
    • pp.43-48
    • /
    • 1988
  • Most of silicone used for water repellent finish is MHP (methyl hydrodiene polysiloxane), which is formed by hydrolysis and condensation polymerization of MHD (methyl hydrodiene dichlorosilane: Me H Si $Cl_2$). The cross-linking theory explains the water repellent mechanism of MHP. The silicone finish on fiber could improve in handle, softness, abrasion resistance, soil repellency, tear strength and crease resistance, as well as water repellency. According to using method silicone-water repellent finishing agents, could be devided into air dry type and curing type. MHP is the typical curing type of water repellent finishing agent, and this type requires the curing temperature above $150^{\circ}C$ at least. High curing temperature is the very drawback of this curing type. For this reason, there has been global interest in the lowering of its temperature. The objective of this study is to investigate merits of alkali treatment for silicone finishing by ANOVA and LSD (least significant difference).

  • PDF

전기 영동을 이용한 공기 중 미생물 분리 (Dielectrophoretic separator for Airborne Microbes)

  • 문희성;남윤우;박재찬;정효일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1683-1684
    • /
    • 2008
  • For direct detection of microbes in air, samples have to be collected but environmental particles such as dust are also trapped in such samples. Therefore the isolation of target bacteria from non-biological materials of similar size is of great importance in the identification of such organisms. Dielectrophoresis is an emerging technique that can rapidly separate cells in microfluidics. In this paper we proposed a new method for the separation of airborne microbes using condensation and dielectrophoresis. This system could be used as a continuous flow through separation system for various particles and utilized as a pretreatment technique for microbe detection.

  • PDF

급수계통 탈기기 필요성 검토 (Study on the Need of Deaerator Installation in Nuclear Power Plant)

  • 최영부;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.189-192
    • /
    • 1998
  • This paper presents the basis for the need of feed-water deaerator installation in nuclear power plant and has been conducting reviews to understand the mechanism of dissolved oxygen(DO) formation as well as removal. DO is produced by feedwater make-up, air inleakage in vacuum system and condensation in condenser, etc. and removed by mechanical method and chemical method. DO has an influence on S/G in the form of denting, pitting, fretting, etc. DO control by deaerator has an great effect on the integrity of S/G in nuclear power plant.

  • PDF

공동주택에서 바닥복사냉방의 시스템 구성과 제어 방안에 관한 연구 (A Study on the System Integration and Control Method of Radiant floor Cooling in Apartment Buildings)

  • 조영흠;석호태;김광우;여명석
    • 한국주거학회논문집
    • /
    • 제15권2호
    • /
    • pp.107-115
    • /
    • 2004
  • The objective of this study is to show the system Integrations and control method for operation of the Radiant Floor Cooling. The systems for radiant floor cooling system consist of only using the radiant floor cooling and the radiant floor cooling integrated with a dehumidification system. And the study is suggested control method with composed radiant floor cooling system through simulations. Radiant floor cooling systems compose of four main parts: an existing radiant heating panel, manifold, cooling source and controller, and sensors. If dehumidifying or supplementary cooling is needed, additional equipments such as PAC and AHU are needed. Simulation results show that control method only using radiant floor cooling system can prevent condensation and set room air temperature with the exception of hot and humid periods and control method using the radiant floor cooling integrated with a dehumidification system is comfort thermal environments and can reduce the cooling load quickly, moreover, show comfort control method to meet various cooling operation situations.