• Title/Summary/Keyword: Air Compressor Design

Search Result 319, Processing Time 0.026 seconds

Experimental Study on the Performance of Refrigeration Cycle for various RPM of Inverter Scroll Compressor (전동 스크롤압축기의 운전rpm에 따른 냉동사이클의 성능에 대한 실험적 연구)

  • Lee, K.S.;Lee, K.A.;Lee, H.Y.;Lee, Y.S.;Kim, Jeongbae
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.42-48
    • /
    • 2014
  • An experimental study was performed estimating COP(Coefficient of Performance) of air-conditioning cycle with inverter scroll compressor. All experiments were done for various compressor speeds from 1000~4000 rpm and used the inverter controller called CANDy to change the compressor rpm. The air-conditioning cycle components in the apparatus were used as same with components of YF hybrid car. To estimate the COP, this study measured the temperature and pressure at inlets and outlets of compressor, condenser, and evaporator. And also measured the compressor input power using Powermeter. Through the experiments, the maximum error to estimate COP was shown about ${\pm}6.09%$ at 3500rpm. This study revealed that the condenser temperature and pressure were increased and the evaporator temperature and pressure were decreased with the increased compressor speed. And also, the COP was decreased with increased compressor speed. Those results can be used the basic and fundamental data to design the air-conditioning cycle with inverter scroll compressor.

A study on the performance of a split system inverter air-conditioner at different operation conditions (분리형 인버터 에어컨의 운전조건에 따른 성능 연구)

  • Kim, Man-Hoe
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.1
    • /
    • pp.113-121
    • /
    • 1998
  • The performance evaluation of a residential split system inverter air-conditioner has been conducted analytically and experimentally at different system operating conditions. A simulation program for modelling an air-conditioning system which consists of a compressor, a condenser, a capillary tube, an evaporator and related attachments was developed on the basis of the Oak Ridge heat pump design model, MARK III. The accuracy of the simulation results for the compressor frequencies of 32, 68 and 79 Hz for the residential split system inverter air-conditioner has been estimated by comparing calculation results to the experimental data and parametric study has been performed to investigate the effect of design parameters and operation conditions on the system performance.

Study on Characteristics of Car Air-con Compressor Under Bench System Fuel Economy Simulation Condition (벤치 연비 모사 조건에서 차량용 에어컨 압축기의 특성에 관한 연구)

  • Yoo, Seong-Yeon;Kim, Young-Shin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.7
    • /
    • pp.705-710
    • /
    • 2012
  • In this study, an experiment on an air conditioning test bench was performed to verify the possibility of fuel economy simulation for the SC03 mode, North America fuel economy certification mode with a/c on condition, one of the vehicle fuel economy evaluation modes. The air conditioning test bench used in this study had each chamber simulating the actual vehicle air conditioning system and the controlling temperature, humidity, and air flow velocity to reproduce environmental conditions. Reliable results were obtained about the compressor RPM and inlet air velocity in front of the condenser corresponding to vehicle speed and air velocity in front of the vehicle, respectively, in the simulation of the SC03 mode, previously performed in CWT, in an air conditioning test bench. It was also discovered that there was a distinct difference in the fuel economy depending on the difference in the compressor displacement in the simulation test of the SC03 mode in the air conditioning test bench under various displacement conditions of the compressor.

Robust Design of Air Compressor-Driving Quadratic Linear Actuator in Fuel Cell BOP System using Taguchi Method

  • Kim, Jae-Hee;Kim, Jun-Hyung;Kim, Jin-Ho
    • Journal of Magnetics
    • /
    • v.17 no.4
    • /
    • pp.275-279
    • /
    • 2012
  • The linear actuator has the inherent drawback of air gap variation because its linear motion is usually guided by the springs, which destabilizes the dynamic performance. In order to design the linear actuator to be insensitive to air gap, this paper describes the robust design of the air compressor driving linear actuator using Taguchi method. The orthogonal arrays are constructed with selected control factors and noise factor for minimum experiment. The control factors are thickness of inner magnet, height of upper yoke, thickness of outer magnet and thickness of lower yoke while noise factor is airgap. The finite element analysis using commercial electromagnetic analysis program "MAXWELL" are performed instead of experiment. ANOVA are performed to investigate the effects of design factors. In result, the optimal robust linear actuator which is insensitive to air gap variation is designed.

Determination of the Operating Frequency and Pipe Design of Inverter Air-conditioner considering Dynamic Characteristics of Inverter Rotary Compressor (진동 특성 파악을 통한 인버터 에어컨의 운전 주파수 및 파이프 형상 결정)

  • 모진용;이진교;박득용;김진섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.203-206
    • /
    • 2001
  • The reduction of chopping noise generated from inverter compressor and the piping design reducing vibration are the most important items in the quality of air conditioner. The chopping noise is identified by the study of the relationship between carrier frequency and natural frequency of the compressor shell. The high carrier frequency is the key factor in reduction of carrier noise. To keep the natural frequencies of the system as far as away from the operating frequencies appears to be the most important factor in the design of piping system.

  • PDF

The Design and Performance Test of a Centrifugal Compressor for HFC-134a Refrigerant (HFC-134a용 원심압축기의 성능시험 및 설계방안)

  • Sin, Jung-Kwan;Kim, Kyung-Hoon;Kang, Shin-Hyoung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.3
    • /
    • pp.139-148
    • /
    • 2010
  • A centrifugal compressor for HFC-134a has been newly designed and developed. Flow analysis using commercial programs was used to evaluate performance and internal flow of the impeller, inlet guide vane and diffuser etc. The purpose of this study is to establish the design theory necessary to the development of HFC-134a centrifugal compressors and to supply basic data related to design by reviewing design values and experimental values through the performance test. The compressor for HFC-134a was also investigated experimentally to check compression performance. The calculated data coincide the test results of compressor. The data obtained in the present study are useful for design of HFC-134a centrifugal compressors.

Experimental Study on Effects of Compressor for Automotive Air Conditioning System on Fuel Economy (차량용 에어컨 압축기가 실차 연비에 미치는 영향에 관한 실험적 연구)

  • Yoo, Seong-Yeon;Kim, Young-Shin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.59-65
    • /
    • 2013
  • In this study, the effects of the compressor for the air conditioning system on the fuel economy were experimentally investigated in an actual automobile. This study aims to analyze the level of contribution of the driving torque of the compressor to the fuel economy. A torque sensor, which is directly set on the clutch of the compressor, is developed to obtain data about the compressor load, which influences the fuel efficiency, and then, the reliability of the torque sensor is verified by comparing the results with those of a torque meter in a bench test. An actual automobile equipped with the compressor and torque sensor is operated in a climate wind tunnel in which appropriate facilities are set up to evaluate the fuel efficiency. The compressor driving torque resulting from the difference in the compressor displacement is found to influence the fuel economy, and the fuel economy is found to be worsened by up to 2~3% with an around 11% increase in the compressor displacement under the same conditions.

A Study on the Stiffness of Wave Washer Spring (웨이브 와셔 스프링의 강성치에 관한 연구)

  • 이수종;왕지석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.3
    • /
    • pp.74-81
    • /
    • 1996
  • The wave washer springs are widely used in non-return valves of fluid, especially in air check valves to confirm the rapid shut-off of valve propers. The stiffness of wave washer springs used in suction and exhaust valves of reciprocating air compressor play an important role on efficiency of the compressor. If the stiffness of the spring is too high, the pressure differences necessary to open the valves become high and the volumetric efficiency of cylinder decreasse. If the stiffness of the spring too low, the valve can not be closed rapidly and the inverse flow of air can take place. So, the optimum stiffness of valve spring is very important and it will be very helpful that the stiffness of wave washer springs to be used in suction and exhaust valves can be calculated in design stage of air compressor. In this paper the formula for calculating the spring constant of wave washer spring is introduced using bending and torsion theory of frames. The experiments are also carried out to measure the spring constants of several samples. It is proven that the calculated spring constants of wave washer springs are coincided well with measured values and that the formula presented in this paper for calculating the spring constants of wave washer spring is very useful for design of valves used in reciprocating air compressor.

  • PDF

Research Trend in Screw Compressor Development (스크류 압축기의 연구개발 동향)

  • Lee, Dae-Young;Kim, Youngil;Nam, Leem Woo
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.12a
    • /
    • pp.151-158
    • /
    • 1998
  • The screw compressor is first invented by a Swedish engineer, Alf Lysholm in 1934. Since then, the development of the screw compressor idea for industrial applications has been continued by the Swedish research organization Svenska Rotor Maskiner, often identified by its initials SRM. The first industrial application of the machine was marketed as an air compressor in the 1950s. The screw compressor which is a positive displacement type compressor compresses gases by the rotation of a pair of mating rotors. The operation of this compressor is entirely rotary and dynamically in balance. Also there is no need for any valve mechanism and there exists less mechanical wear between the parts compared to the conventional reciprocating compressors. Due to these prominent features, the screw compressor has been rapidly spread into the air compressor market replacing the conventional reciprocating compressors and begun to be applied as a refrigerant compressor since the 1960s. In this work, the operation principle of the screw compressor is described in brief and the major design parameters affecting the compressor performance are classified. The international research trend in screw compressor development is introduced and the current situation in our country is described.

  • PDF

Design of Multiple-Air-Compressor Automatic Controller for Energy Savings (에너지 절약을 위한 다수 에어컴퓨레셔 자동제어장치 설계)

  • Yang, Sung-Kyu;Kim, Gab-Soon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.5
    • /
    • pp.53-59
    • /
    • 2020
  • This paper describes the design of a remote control device that can control the ON/OFF state of multiple air compressors using wireless communication. The main remote controller and air compressor remote controller were designed using a microprocessor (ATmega128), and the circuit diagram was configured to wirelessly communicate using A Zigbee module between the two remote controllers. The result of the measurement of wireless communication distance between the two remote controllers was more than 1.1 km.