DOI QR코드

DOI QR Code

A study on the performance of a split system inverter air-conditioner at different operation conditions

분리형 인버터 에어컨의 운전조건에 따른 성능 연구

  • 김만회 (삼성전자 기술총괄 생활시스템연구소)
  • Published : 1998.01.01

Abstract

The performance evaluation of a residential split system inverter air-conditioner has been conducted analytically and experimentally at different system operating conditions. A simulation program for modelling an air-conditioning system which consists of a compressor, a condenser, a capillary tube, an evaporator and related attachments was developed on the basis of the Oak Ridge heat pump design model, MARK III. The accuracy of the simulation results for the compressor frequencies of 32, 68 and 79 Hz for the residential split system inverter air-conditioner has been estimated by comparing calculation results to the experimental data and parametric study has been performed to investigate the effect of design parameters and operation conditions on the system performance.

Keywords