• Title/Summary/Keyword: Aging Measurement

Search Result 468, Processing Time 0.035 seconds

Application for Depression Level Measurement for Aging Population (노인의 우울척도 측정 앱 설계)

  • Choung, Hye-Myoung
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2018.07a
    • /
    • pp.367-368
    • /
    • 2018
  • 본 논문에서는 노인들의 정신건강 중 우울에 관한 정도를 측정해 볼 수 있는 앱의 개발을 위하여 한국형GDS를 활용하는 컨텐츠를 설계하여 노인성 우울을 예방하고 조기 진단하여 노인의 건강한 삶에 도움을 주고자 한다.

  • PDF

Wireless Bio-signal Monitoring System (무선 생체신호 모니터링 시스템)

  • Kim, Do-Kyoung;Lee, In-Kwang;Cha, Eun-Jong;Kim, Kyung-Ah
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2055-2056
    • /
    • 2011
  • As rapid aging and high economic level, people are interested in their wellness. And it needs to examine the condition of their health constantly. Proposed device can measure bio-signal by connecting several measurement modules such as spirometric module, blood glucose measurement module, uro-flow measurement module and temperature measurement module. These modules can be chosen as occasion demands. In addition, developed user program enables patients to monitor bio-signal at their own place via the personal computer.

  • PDF

Development of Measurement Assurance Test Procedures between Calibrations (계기 검교정간의 보증시험 절차의 개발)

  • Yum, Bong-Jin;Cho, Jae-Gyeun;Lee, Dong-Wha
    • IE interfaces
    • /
    • v.6 no.1
    • /
    • pp.55-65
    • /
    • 1993
  • A nonstandard instrument used in the filed frequently becomes out-of-calibration due to environmental noise, misuse, aging, etc. A substantial amount of loss may result if such nonstandard instrument is used to check product quality and performance. Traditional periodic calibration at the calibration center is not capable of detecting out-of-calibration status while the instrument is in use, and therefore, statistical methods need to be developed to check the status of a nonstandard instrument in the field between calibrations. Developed in this paper is a unified measurement assurance model in which statistical calibration at the calibration center and measurement assurance test in the filed are combined. We developed statistical procedures to detect changes in precision and in the coefficients of the calibration equation. Futher, computational experiments are conducted to evaluate how the power of test varies with respect to the parameters involved. Based upon the computational results we suggest procedures for designing effective measurement assurance tests.

  • PDF

The measurement of partial discharge for preventive diagnosis in power machinery (전력용 기기의 예방진단을 위한 부분방전측정)

  • 김태성;구할본;임장섭;정우성
    • Electrical & Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.42-48
    • /
    • 1994
  • The preventive diagnosis technique for power system is being highlighted as a research area for deterioration of insulation in machinery because of high-voltage power system. We make efforts to develop not only diagnosis of aging state but also detection of defects in the initial stage from preventive diagnosis technique. Especially, partial discharge is actively studied as a non-destructive diagnosis technique and very useful because partial discharge measurement reduces damage than conventional diagnosis technique. The loaded stress during this test is smaller than that of other diagnosis techniques. But the continuous research for various complicated analysis method is required because partial discharge has very small signals and its signals have complex forms. In this paper, the measurement of partial discharge was investigated and studied on many specimens with void. We made samples having artificial voids and measured partial discharge. In order to use as a practical diagnosis technique, we studied ways of measurement, measured illustrations and types of partial discharge which could be used in order to diagnose defects of power machinery.

  • PDF

Measurement of Resistance of Multi-Grounded System by Ground Current Measurement (접지전류 측정에 의한 다중 접지계통의 접지저항 측정)

  • 최종기;안용호;정길조;한병성;김경철
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.4
    • /
    • pp.234-237
    • /
    • 2004
  • Measuring ground resistance has been a popular method of evaluation of the grounding electrode performance. If some portions of grounding electrodes are lost by corrosion, aging or other reasons, consequent deteriotation of the grounding performance would be resulted. It is one of the reasons why it is required to evaluate the performance of grounding systems regularly. However, in case of the electric facilities with multi-grounded system such as power substations with multi-grounded overhead ground wires and/or distribution line neutrals, it is practically difficult to disconnect neutrals or skywires from the substation grounding mesh for the ground resistance measurement. In this paper, a method for the grounding performance measurement of multi-grounded systems, which is based on the measuring ground current distributions, has been proposed. A field test results has shown the validity of the proposed test method.

Measurement of Resistance of Multi-Grounded System by Ground Current Measurement (접지전류 측정에 의한 다중 접지계통의 접지저항 측정)

  • 최종기;안용호;정길조;한병성;김경철
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.234-234
    • /
    • 2004
  • Measuring ground resistance has been a popular method of evaluation of the grounding electrode performance. If some portions of grounding electrodes are lost by corrosion, aging or other reasons, consequent deteriotation of the grounding performance would be resulted. It is one of the reasons why it is required to evaluate the performance of grounding systems regularly. However, in case of the electric facilities with multi-grounded system such as power substations with multi-grounded overhead ground wires and/or distribution line neutrals, it is practically difficult to disconnect neutrals or skywires from the substation grounding mesh for the ground resistance measurement. In this paper, a method for the grounding performance measurement of multi-grounded systems, which is based on the measuring ground current distributions, has been proposed. A field test results has shown the validity of the proposed test method.

Electrical Life Time Constant Estimation of Ceramic Element for Sensor (센서용 세라믹 소체의 전기적 수명지수 산출)

  • Jeong, Joo-Young;Kang, Dong-Sik;Sun, Jong-Ho;Heo, Jong-Cheol;Choo, Young-Bae;Park, Chung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1995-1999
    • /
    • 2009
  • A partial discharge(PD) measurement is a very effective method to assess the insulation condition of high-voltage machines. It is necessary that the life time of the on-line PD measurement sensor is assessed. Therefore, the electrical life time assessment method of ceramic element was reviewed in order to estimate the life time of the on-line PD measurement sensor. The samples were prepared according to the reviewed method and were tested at 8kV, 9kV and 10kV. Based on the obtained results, the life time constant is shown above 59. Also, it is assumed that the estimated life time constant can be used to anticipate the life time and to assess the conformity of the on-line PD measurement sensor.

Mechanical Properties and Smoothness of Semiconductive Materials(Shield) in Power Cable (전력케이블내 반도전 재료(층)의 기계적 특성 및 평활도에 관한 연구)

  • Yang Jong-Seok;Lee Yong-Sung;Park Dae-Hee;Lee Kyoung-Yong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.4
    • /
    • pp.154-160
    • /
    • 2005
  • We have investigated thermal properties showed by changing the content of carbon black which is the component parts of semiconductive shield in underground power transmission cable. Specimens were made of sheet with the nine of those for measurement. Density of specimens was measured by density meter, and then stress-strain of specimens was measured by TENSOMETER 2000. A speed of measurement was 200[mm/min], ranges of stress and strain were 400(Kgf/$cm^2$) and 600[$\%$]. In addition, tests of stress-strain were progressed by aging specimens at air oven. Finally surface profile was shown in order to looking for protrusion of specimens by using smoothness tester. Density was highly measured according to increasing the content of carbon black from this experimental result, and stress was decreased, while strain was increased according to increasing the content of carbon black. And stress-strain were decreased some after aging because of oxidation reaction of chemical defect. Lastly surface of specimens smoothed generally.

Mechanical Properties and Smoothness of Semiconductive Shield for Power Transmission by Carbon Black Content (카본블랙의 함량에 따른 송전용 반도전 재료의 기계적 특성 및 Smoothness)

  • Lee, Kyoung-Yong;Yang, Jong-Seok;Lee, Kwan-Woo;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.301-307
    • /
    • 2004
  • To improve mean-life and reliability of power cable in this paper, we have investigated stress-strain and smoothness showing by changing the content of carbon black that is semiconductive additives for underground power transmission. Specimens were made of sheet form with the three of existing resins and the nine of specimens for measurement. Stress-strain of specimens was measured by TENSOMETER 2000. A speed of measurement was 200[mm/min], ranges of stress and strain were $400(Kgf/cm^2)$ and 600[%]. In addition tests of stress-strain were progressed by aging specimens at air oven. Finally we wished to look for protrusion of specimens by using smoothness tester. According to increasing the content of carbon black from this experimental result, yield stress was increased, while strain was decreased. And stress-strain were decreased some after aging because of oxidation reaction of chemical defect. Lastly surface of specimens smoothed generally.

  • PDF

Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent (계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가)

  • Cho, Han-Goo;Han, Dong-Hee;Lee, Un-Yong;Lim, Kee-Joe;Choi, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1121-1124
    • /
    • 2004
  • Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. The diagnosis methods in off-line most are the method for virgin and last aged sample. However, the diagnosis method in on-line is method that can be evaluate sample state as progressing continuously aging test in beginning, The diagnosis method in on-line is arranged as following: leakage current measurement, electric field, surface state investigation, thermal image, emitting light measurement and then so. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination.

  • PDF