• Title/Summary/Keyword: Ag/AgCl electrode

Search Result 214, Processing Time 0.04 seconds

Pilot Test of Electrocardiogram Measurement Method for Conductive Textiles Electrode Position in Bed Condition (침대 형태에서 기능성 직물 전도성 전극 위치에 대한 심전도 측정 방법의 Pilot Test)

  • Jun won, Choi;Lina A., Asante;Chang Hyun, Song;Halim, Chung;Han Sung, Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.80-84
    • /
    • 2023
  • Electrodes are one of the types of biosensors capable of measuring bio signals, such as electrocardiogram (ECG) and electromyogram (EMG) signals. These electrodes are used in various fields and offer the advantage of being able to measure ECG signals without the need for skin attachment, compared to Ag/AgCl electrodes. The purpose of this study was to evaluate the efficacy of conductive textile electrodes in collecting ECG signals in a bed-like environment. Three adult participants were involved, and a total of 30 minutes of ECG signals were collected for each participant. The collected ECG signals were analyzed to determine the heart rate, normLF and a comparison was made between the conductive textile electrodes and Ag/AgCl electrodes. As a result, the change in heart rate and normLF could be observed, and in particular, the difference between the two electrodes decreased. This study confirmed that conductive textile electrodes can effectively collect ECG signals in a bed-like environment. It is hoped that this research will lead to the development of a system that can detect various sleep-related diseases through the use of these electrodes.

Simultaneous measurement of oxygen permeability by using of multi-functional oxygen electrode (다기능 산소전극에 의한 산소투과특성 동시측정)

  • 이동희;정진휘;유형풍;김태진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.532-535
    • /
    • 2000
  • We have fabricated a sensor system for on-line monitoring the oxygen permeability and diffusivity of six different polymer films using the miniaturized 6 cathode(Ag)-single anode(Ag/AgCl) type hexagonal oxygen electrode. This system consists of multiple input front-end electronics, signal conditioning circuit using the embedded microcontroller 80C196KC, PC interface circuit and PC with the OS for microcontroller and the operating program for this system. The digital low-[ass filter was programmed and the simulated filter characteristics were enough to eliminate the noise from sensor signal. According to the experimental results, the linearity coefficients of the output voltage to oxygen partial pressure for each sensor electrode of six cathode type oxygen sensor are 0.998, 0.997, 0.998, 0.997, 0.997, 0.997 respectively, and the response times are all within 4 minutes.

  • PDF

Electrochemical Reduction of Perchlorate Using Mercury Film Electrode (수은 막전극을 이용한 수용액 중 과염소산이온의 전기화학적 환원)

  • Myung, Noseung;Kim, Eun Young;Jee, Hyung-Woo;Keum, Narae;Rhee, Insook;Paeng, Ki-Jung
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.3
    • /
    • pp.95-100
    • /
    • 2016
  • A method for electrochemical degradation of the perchlorate anion ($ClO_4{^-}$) using mercury film electrode has been studied. Electrochemical method has relatively simple pre-treatment. However, electrochemical method should avoid interference from hydrogen evolution at the applied potential to degradation of perchlorate ion, and thus applied electrode should have large hydrogen overvoltage which suppressed the hydrogen evolution at the working reduction potential to prevent hydrogen evolution. In this study, we used mercury film electrode as a working electrode which has a large overvoltage. Ag / AgCl (sat. NaCl) was used as a reference electrode, and platinum was used as a counter electrode. Mercury film electrode was made by cyclic voltammetry (CV) method. The deposition time was decided as 10 minute, and the stability of the mercury electrode in perchlorate solution was confirmed by CV. The reduction potential of perchlorate was checked by using CV method, and decomposition of perchlorate was performed by using chronoamperometric (CA) method. Also, ion chromatography (IC) was used to confirm the degradation rates of perchlorate.

Biomimetic Copper Complex Containing Polymer Modified Electrode for Electrocatalytic Reduction of Oxygen

  • Saravanakumar, D.;Nagarale, Rajaram Krishna;Jirimali, Harish Chandra;Lee, Jong Myung;Song, Jieun;Lee, Junghyun;Shin, Woonsup
    • Journal of Electrochemical Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.298-305
    • /
    • 2016
  • The development of non-precious metal based electrocatalysts is highly desired for the oxygen reduction reaction (ORR) as alternates to noble metal based ORR electrocatalysts. Herein, we report mononulcear copper(II) complex $[CuLbpy]ClO_4$ (L=4-[(2-hydroxyphenylimino)methyl]benzoic acid) containing poly(allylamine.HCl) polymer (PAlACuLbpy) as an electrocatalyst for oxygen reduction reaction (ORR). PAlACuLbpy was mixed with poly(acrylic acid) and tetraethylortho silicate to prepare a composite and then deposited on the screen printed electrode surface. The modified electrode (PAlACuLbpy/PCE) is highly stable and showed a quasi-reversible redox behavior with $E_{1/2}=-0.2V$ vs. Ag/AgCl(3 M KCl) in 0.1 M phosphate buffer at pH 7 under argon atmosphere. PAlACuLbpy/PCE exhibited a remarkable ORR activity with an onset potential of -0.1 V vs Ag/AgCl in 0.1 M PB (pH 7) in the presence of oxygen. The kinetics for ORR was studied by rotating disk voltammetry in neutral aqueous medium and the results indicated that the number of electrons involving in the ORR is four and the conversion products are water and hydrogen peroxide.

Preparation of a Liquid Membrance Type Ion-Selective Electrode and Its Application to the Potentiometric Titration (액체막형 구리이온 선택성 전극의 제작과 전위차적정에의 응용)

  • Heung Lark Lee;Seung Tae Yang
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.137-143
    • /
    • 1985
  • Construction of a liquid membrane type of cupric ion selective electrode and its application to the potentiometric titration have been studied. A liquid ion-exchange membrance was prepared by extracting Cu(II) in aqueous solution into 1-(2-pyridylazo)-2-naphthol/nitrobenzene. A Ag/AgCl internal reference electrode was dipped into the aqueous reference solution of $1.00 {\times} 10^{-3}M\;Cu(NO_3)_2$ buffered with HAc-NaAc buffer solution, which was in contact with the nitrobenzene extract. The electrode showed the nernstian response to Cu(II) in the concentration range from $1.00{\times} 10^{-6}$ to $1.00{\times} 10^{-3}$M. The most suitable ion-exchanger concentration in the liquid membrane was $1.00{\times} 10^{-4}$M. The selectivity coefficients of the electrode for the various metal cations were investigated. The electrode was applied to the potentiometric titration of Cu(II) with EDTA.

  • PDF

Photoelectrochemical Converision with $SrTiO_3$ Ceramic Electrodes ($SrTiO_3$ 세라믹 전극에 의한 광전기 화학변환)

  • 윤기현;김태희
    • Journal of the Korean Ceramic Society
    • /
    • v.22 no.3
    • /
    • pp.19-24
    • /
    • 1985
  • The phtoelectrochemical porperties of $Nb_2O_5$, $Sb_2O_3$ and $V_2O_5$ doped and pure $SrTiO_3$ ceramic electodes were investigated. Shapes of I-V and I-λ characteristics of the pure $SrTiO_3$ ceramic electrode are similar to those of SrTiO3 single crystal electorde ; the anodic current strats at -0.9V (vs. Ag/AgCI) in 1 N-NaOH aqueous solution and the photoresponse appears at a wavelength of about 390nm and the quantum efficiency is about 3.5% at wavelength of 390nm under 0.5V vs. Ag/AgCl. Photocurrents of $Nb_2O_5$, $Sb_2O_3$ and $V_2O_5$ doped electrodes and $V_2O_5$ doped ceramic electrode appears at wavelength of 390nm and 500nm respectively.

  • PDF

Electrochemical Deposition Characteristics of Ca2+ on Cu Wire Electrode in CaCl2 Molten Salt (CaCl2 용융염에서 Ca2+의 Cu 전극에 대한 전기화학적 증착 특성평가)

  • Hwang, Dong Wook;Lee, Jong Hyeon;Jeong, Sang Mun
    • Korean Chemical Engineering Research
    • /
    • v.60 no.2
    • /
    • pp.175-183
    • /
    • 2022
  • With the expansion of the automobile market, the demand for Nd as an essential rare earth material for automobile motors is rapidly increasing. Research on the calcio-thermic reduction process between Nd2O3 and calcium-based alloys has been extensively studied in order to manufacture Nd. In this study, Ca-Cu, as a reducing for Nd2O3, was prepared by electrolysis in CaCl2 molten salt. Cu wire and graphite were employed as a working electrode and a counter electrode for electrolysis reaction, respectively. The reference electrode was manufactured by putting Ag wire in a mixture of AgCl and CaCl2 at a ratio of 1:99 mol%. The cyclic voltammetry results showed that the deposition of Ca2+ on the surface of working electrode was observed from a potential of -1.8 V, and the reduction potential of Ca2+ decreased as the reaction temperature increased. The diffusion coefficient of Ca2+ calculated by the chronoamperometry experiment was found to be 5.4(±6.8)×10-6 cm2/s. In addition, Ca-Cu liquid alloy was prepared by applying a constant potential to Cu electrodes. The element ratio of Ca-Cu alloy formed by applying a potential of -2.0 V was found to Ca:Cu=1:4.

Electrochemical Properties of Fatty Acid Containing Azobenzene for Phospholipid (인지질에 따른 아조벤젠기를 함유한 지방산의 전기화학적 특성)

  • Park, Keun-Ho;Son, Tae-Chul;Lee, Kyoung-Goo;Kim, Nam-Suk;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.43-46
    • /
    • 2002
  • We have investgated the photoisomerization using light irradiation 8A5H-phospholipid( L-$\alpha$-dimyristoylphosphatidylcholine[DMPC], L-$\alpha$-dilauroylphosphatidylcholine[DLPC]mixture LB film accumulated by monolayer on an ITO. We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system, An Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode measured in $NaClO_{4}$ solution at a variable concentration and variable number layers LB film. The scan rate was 100mV/s.

  • PDF

Electrochemical properties of Langmuir-blodgett Films of Fatty acid containing Azobezene (아조벤젠기를 가진 지방산 Langmuir-blodgett막의 전기화학적 특성)

  • 박근호;김범준;손태철;이경구;주찬홍;박태곤
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.459-462
    • /
    • 2001
  • We have investgated the photoisomerization using light irradiation 8A5H LB film accumulated by monolayer and three layers on an ITO. We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system, An Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode measured in 0.1mol/L NaClO$_4$ solution. The scan rate was 100mv/s.

  • PDF