초기 손상을 입은 비연성 철근콘크리트 골조의 FRP재킷으로 보수된 기둥의 수치해석모델 (Numerical Column Model for Damaged Non-ductile Reinforced Concrete Frame Repaired Using FRP Jacketing System)

  • 신지욱;전종수;김준희
    • 한국지진공학회논문집
    • /
    • 제22권5호
    • /
    • pp.291-298
    • /
    • 2018
  • Existing reinforced concrete building structures have seismic vulnerabilities under successive earthquakes (or mainshock-aftershock sequences) due to their inadequate column detailing, which leads to shear failure in the columns. To improve the shear capacity and ductility of the shear-critical columns, a fiber-reinforced polymer jacketing system has been widely used for seismic retrofit and repair. This study proposed a numerical modeling technique for damaged reinforced concrete columns repaired using the fiber-reinforced polymer jacketing system and validated the numerical responses with past experimental results. The column model well captured the experimental results in terms of lateral forces, stiffness, energy dissipation and failure modes. The proposed column modeling method enables to predict post-repair effects on structures initially damaged by mainshock.

Wave shape analysis of seismic records at borehole of TTRH02 and IWTH25 (KiK-net)

  • Kamagata, Shuichi
    • Earthquakes and Structures
    • /
    • 제18권3호
    • /
    • pp.297-312
    • /
    • 2020
  • The KiK-net by NIED is a vertical array measurement system. In the database of KiK-net, singular pulse waves were observed in the seismic record at the borehole of TTRH02 during the mainshock (the magnitude of Japan Meteorological Agency (MJ) 7.3, MW 6.8) and aftershock (Mj 4.2) of Tottori-ken Seibu earthquake in 2000. Singular pulse waves were also detected in the seismic records at the borehole of IWTH25 during the Iwate-Miyagi Nairiku earthquake in 2008 (MJ 7.2, MW 6.9). These pulse waves are investigated by using the wave shape analysis methods, e.g., the non-stationary Fourier spectra and the double integrated displacement profiles. Two types of vibration modes are discriminated as the occurrence mechanism of the singular pulse waves. One corresponds to the reversal points in the displacement profile with the amplitude from 10-4 m to 10-1 m, which is mainly related to the fault activity and the amplification pass including the mechanical amplification (collision) of the seismograph in the casing pipe. The other is the cyclic pulse waves in the interval of reversal points, which is estimated as the backlash of the seismograph itself with the amplitude from 10-5 m to 10-4 m.

Two-dimensional numerical investigation of the effects of multiple sequential earthquake excitations on ancient multi-drum columns

  • Papaloizou, Loizos;Polycarpou, Panayiotis;Komodromos, Petros;Hatzigeorgiou, George D.;Beskos, Dimitri E.
    • Earthquakes and Structures
    • /
    • 제10권3호
    • /
    • pp.495-521
    • /
    • 2016
  • Ancient monuments of Greek and Roman classical architecture usually consist of multi-drum columns that are constructed of stone blocks placed on top of each other. Several research studies deal with the seismic behaviour of such structures, since earthquakes are common causes of destruction of such monuments. This paper investigates the effect of multiple earthquakes on the seismic performance of multi-drum columns, through numerical simulations and parametric analyses. The Discrete Element Method and an appropriate contact model have been implemented in a specially developed software application that is able to efficiently perform the necessary simulations in two dimensions. Specifically, various strong ground excitations are used in series for the computation of the collective final deformation of multi-drum columns. In order to calculate this cumulative deformation for a series of ground motions, the individual deformation of the column for each excitation is computed and then used as initial conditions for the next earthquake excitation. Various multi-drum columns with different dimensions are also considered in the analyses in order to examine how the geometric characteristics of columns can affect their seismic sequence behaviour, in combination with the excitation frequency content.

Application of an extended Bouc-Wen model for hysteretic behavior of the RC structure with SCEBs

  • Dong, Huihui;Han, Qiang;Du, Xiuli
    • Structural Engineering and Mechanics
    • /
    • 제71권6호
    • /
    • pp.683-697
    • /
    • 2019
  • The reinforced concrete (RC) structures usually suffer large residual displacements under strong motions. The large residual displacements may substantially reduce the anti-seismic capacity of structures during the aftershock and increase the difficulty and cost of structural repair after an earthquake. To reduce the adverse residual displacement, several self-centering energy dissipation braces (SCEBs) have been proposed to be installed to the RC structures. To investigate the seismic responses of the RC structures with SCEBs under the earthquake excitation, an extended Bouc-Wen model with degradation and self-centering effects is developed in this study. The extended model realized by MATLAB/Simulink program is able to capture the hysteretic characteristics of the RC structures with SCEBs, such as the energy dissipation and the degradation, especially the self-centering effect. The predicted hysteretic behavior of the RC structures with SCEBs based on the extended model, which used the unscented Kalman filter (UKF) for parameter identification, is compared with the experimental results. Comparison results show that the predicted hysteretic curves can be in good agreement with the experimental results. The nonlinear dynamic analyses using the extended model are then carried out to explore the seismic performance of the RC structures with SCEBs. The analysis results demonstrate that the SCEB can effectively reduce the residual displacements of the RC structures, but slightly increase the acceleration.

과거 2000년간 서울 및 수도권에서 발생한 피해 지진의 특성 (Characteristics of Damaging Earthquakes Occurred in Seoul Metropolitan Area for the Last Two Thousand Years)

  • 경재복
    • 한국지구과학회지
    • /
    • 제33권7호
    • /
    • pp.637-644
    • /
    • 2012
  • 서울을 비롯한 수도권 일대는 우리나라 인구의 약 40%가 집중되어 갑작스럽게 닥치는 지진재해에 매우 취약한 곳이다. 역사문헌 분석에 의하면 과거 2000여 년간 서울 지역에서 발생한 피해 지진의 최대 크기는 MMI 진도 VIII-IX로 평가되며, 이들 지진으로 건물의 큰 흔들림, 담장과 성첩의 붕괴, 민가 붕괴, 다수의 사상자가 발생하였다. 서울 지역에서 MM 진도 VIII 이상의 피해지진은 1세기(A.D. 27년, 89년)에 2회 발생하였으며, 약 1430여년의 긴 휴지기 후 16-17세기(1518년, 1613년, 1692년)에 다시 3회 발생하였고, 그 후 현재 까지 휴지기 상태이다. 1518년 서울 지진(진도 VIII-IX)시에는 약 19일에 걸쳐 24회 이상의 여진이 발생하였으며, 서울 인접 지역과 황해도 지역에도 20여 일간에 걸쳐 많은 유발지진을 발생시켰다. 역사문헌에 근거한 서울 지역의 발생 가능한 최대 피해 지진은 진도 VIII-IX 이며 이러한 지진의 발생은 약 1400-1500여년의 긴 간격을 보인다.

Collapse Vulnerability and Fragility Analysis of Substandard RC Bridges Rehabilitated with Different Repair Jackets Under Post-mainshock Cascading Events

  • Fakharifar, Mostafa;Chen, Genda;Dalvand, Ahmad;Shamsabadi, Anoosh
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권3호
    • /
    • pp.345-367
    • /
    • 2015
  • Past earthquakes have signaled the increased collapse vulnerability of mainshock-damaged bridge piers and urgent need of repair interventions prior to subsequent cascading hazard events, such as aftershocks, triggered by the mainshock (MS). The overarching goal of this study is to quantify the collapse vulnerability of mainshock-damaged substandard RC bridge piers rehabilitated with different repair jackets (FRP, conventional thick steel and hybrid jacket) under aftershock (AS) attacks of various intensities. The efficacy of repair jackets on post-MS resilience of repaired bridges is quantified for a prototype two-span single-column bridge bent with lap-splice deficiency at column-footing interface. Extensive number of incremental dynamic time history analyses on numerical finite element bridge models with deteriorating properties under back-to-back MS-AS sequences were utilized to evaluate the efficacy of different repair jackets on the post-repair behavior of RC bridges subjected to AS attacks. Results indicate the dramatic impact of repair jacket application on post-MS resilience of damaged bridge piers-up to 45.5 % increase of structural collapse capacity-subjected to aftershocks of multiple intensities. Besides, the efficacy of repair jackets is found to be proportionate to the intensity of AS attacks. Moreover, the steel jacket exhibited to be the most vulnerable repair intervention compared to CFRP, irrespective of the seismic sequence (severe MS-severe or moderate AS) or earthquake type (near-fault or far-fault).

Local Seismic Activity around the Lützow-Holm Bay, East Antarctica

  • Kaminuma, Katsutada;Kanao, Masaki
    • Ocean and Polar Research
    • /
    • 제26권3호
    • /
    • pp.523-529
    • /
    • 2004
  • The seismic monitoring at Syowa Station$(69^{\circ}S,\;39^{\circ}E: SYO)$, located on the continental margin of the Eastern Dronning Maud Land, East Antarctica, began in 1959. Phase readings of the earthquakes have been reported since 1967 and have been annually published as part of the Data Report Series of the National Institute of Polar Research since 1968. An observation of a tripartite seismic network was carried out at SYO for a period of three years from 1987 to 1990. Epicenters of local earthquakes were determined for the first time by using the array network for the three-year period. Many different types of earthquakes, such as the mainshock-aftershock type, twin earthquake, earthquake swarms, etc., were detected during the period. After this, local events around SYO have been detected empirically from their waveforms recorded on seismograms. The seismic activity for the period of 1987-1990 was higher than that of the following decade. Earthquake epicenters, occurring during that period, were highly localized along the coast and in the central part of the $L\"{u}tzow-Holm$ Bay (LHB). Nine local earthquakes, recorded during the period of 1990-1996, showed many different types of events. The seismicity for the period of 1990-1996 was very low and the magnitudes ranged from 0.1 to 1.4. The locations of some events were determined by using the single station method for SYO, i.e., using the particle motions of the initial phase and S-P time. Two local events were detected in 1998 and one event in 2001. It would be estimated that the stress concentration was related to the glacial rebound around the LHB. Afterwards, we will be able to eventually examine the relationship between the seismicity around Antarctica and deglacial phenomena such as crustal uplift, and sea level change within the earth environmental system.

Computational earthquake performance of plan-irregular shear wall structures subjected to different earthquake shock situations

  • Cao, Yan;Wakil, Karzan;Alyousef, Rayed;Yousif, Salim T.;Jermsittiparsert, Kittisak;Ho, Lanh Si;Alabduljabbar, Hisham;Alaskar, Abdulaziz;Alrshoudi, Fahed;Mohamed, Abdeliazim Mustafa
    • Earthquakes and Structures
    • /
    • 제18권5호
    • /
    • pp.567-580
    • /
    • 2020
  • In this paper, irregularly designed planar reinforced concrete wall structures are investigated computationally. For this purpose, structures consisting of four regular and irregular models of short-order (two-class) and intermediate (five-class) types have been investigated. The probabilistic evaluation of seismic damage of these structures has been performed by using the incremental inelastic dynamic analysis to produce the seismic fragility curve at different levels of damage. The fragility curves are based on two classes of maximum damage indices and the Jeong-Nansha three-dimensional damage index. It was found that there is a significant increase in damage probability in irregular structures compared to regular ones. The rate of increase was higher in moderate and extensive damage levels. Also, the amount of damage calculated using the two damage indices shows that the Jeong-Nensha three-dimensional damage index in these types of structures provides superior results.

Seismic performance assessments of precast energy dissipation shear wall structures under earthquake sequence excitations

  • Zhang, Hao;Li, Chao;Wang, Zhi-Fang;Zhang, Cai-Yan
    • Earthquakes and Structures
    • /
    • 제18권2호
    • /
    • pp.147-162
    • /
    • 2020
  • This paper presents a novel precast energy dissipation shear wall (PEDSW) structure system that using mild steel dampers as dry connectors at the vertical joints to connect adjacent wall panels. Analytical studies are systematically conducted to investigate the seismic performance of the proposed PEDSW under sequence-type ground motions. During earthquake events, earthquake sequences have the potential to cause severe damage to structures and threaten life safety. To date, the damage probability of engineering structures under earthquake sequence has not been included in structural design codes. In this study, numerical simulations on single-story PEDSW are carried out to validate the feasibility and reliability of using mild steel dampers to connect the precast shear walls. The seismic responses of the PEDSW and cast-in-place shear wall (CIPSW) are comparatively studied based on nonlinear time-history analyses, and the effectiveness of the proposed high-rise PEDSW is demonstrated. Next, the foreshock-mainshock-aftershock type earthquake sequences are constructed, and the seismic response and fragility curves of the PEDSW under single mainshock and earthquake sequences are analyzed and compared. Finally, the fragility analysis of PEDSW structure under earthquake sequences is performed. The influences of scaling factor of the aftershocks (foreshocks) to the mainshocks on the fragility of the PEDSW structure under different damage states are investigated. The numerical results reveal that neglecting the effect of earthquake sequence can lead to underestimated seismic responses and fragilities, which may result in unsafe design schemes of PEDSW structures.

역단층성 변위에 의한 Coulomb stress transfer (Coulomb stress transfer due to reverse faulting displacement field)

  • 고민석;장찬동;이준복;심택모
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2008년도 공동학술대회
    • /
    • pp.149-154
    • /
    • 2008
  • 소규모 역단층성 변위에 의한 단층주변부의 Coulomb stress의 변화를 모델 분석하였다. 본 연구에서 사용된 단층의 기하학적 형태와 응력자료는 경주시에 위치한 제4기 단층인 읍천단층의 조건을 적용하였다. Coulomb stress 모델링에서 단층면을 따라 역단층성 소규모 변위(10cm)를 가정할 경우 단층의 가장자리 주변(주향방향 양끝과 경사방향)에서 Coulomb stress의 변화가 상대적으로 높게(>2 bar) 나타났고 단층의 상하부에서 감소하는 경향을 보였다. 단층의 수직적인 단면에서는 단층의 직하부와 단층 주향의 수직방향에 "T" 자 형태의 낮은 음의 값을 보였다. 본 연구 결과는 주 단층의 역단층성 변위에 의해 나타나는 여진의 전파경로 양상을 보여준다.