• 제목/요약/키워드: Aerosol particle

검색결과 665건 처리시간 0.023초

실시간 입자분포 측정을 위한 Radial Exhaust Multi-port System의 개발 및 성능평가 (Development and Performance Evaluation of Radial Exhaust Multi-port System for Real-time Particle Size Distribution Measurement)

  • 이홍규;이양우;전기수;안강호
    • 한국입자에어로졸학회지
    • /
    • 제9권3호
    • /
    • pp.133-137
    • /
    • 2013
  • Measuring particle size distribution is one of the primary concerns in aerosol studies. For a nano-particle size distribution measurement, many scientists use a combination of a differential mobility analyzer (DMA) and a condensation particle counter (CPC) system, which is a called scanning mobility particle sizer (SMPS). Although it has a very high particle size resolution, some issues still remain. These problems include residence time between a DMA and a CPC, discontinuity of a CPC, and disturbance due to long scanning time during the precise measurement of particles. In particular, long scanning time is not adequate for measuring particle size distribution since the particle concentration is changing during the measurement. In this study, we developed radial exhaust multi-port system (REM-system) with no scanning time and high resolution to measure real-time particle size distribution. As a result of the REM-system performed using mono-disperse particle, it is expected that this system will be suitable for measuring continuously changing aerosol. If the counting efficiency of multi-condensation particle counter (M-CPC) and data inversion matrix are completed, REM-system will be a very adequate system for unsteady aerosol, which changes for SMPS scanning time.

Aerosol Wall Loss in Teflon Film Chambers Filled with Ambient Air

  • Lee Seung-Bok;Bae Gwi-Nam;Moon Kil-Choo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제20권E1호
    • /
    • pp.35-41
    • /
    • 2004
  • Aerosol wall loss is an important factor affecting smog chamber experiments, especially with chambers made of Teflon film. In this work, the aerosol wall loss was investigated in 2.5 and $5.8-m^3$ cubic-shaped Teflon film chambers filled with ambient air. The natural change in the particle size distribution was measured using a scanning mobility particle sizer in a dark environment. The rate of aerosol wall loss was obtained from the deposition theory suggested by Crump and Seinfeld (1981). The measured rates of aero-sol wall loss were In a good agreement with the theoretical and experimental values given by McMurry and Rader (1985), implying that the electrostatic effect enhances particle deposition on the chamber wall. The significance of aerosol wall loss correction was demonstrated with the photochemical reaction experiments using the ambient air.

Tethered-Balloon Package System 개발 및 대기 에어로졸의 연직 분포 측정 (Development of Tethered-Balloon Package System for Vertical Distribution Measurement of Atmospheric Aerosols)

  • 은희람;이홍규;이양우;안강호
    • 한국입자에어로졸학회지
    • /
    • 제9권4호
    • /
    • pp.253-260
    • /
    • 2013
  • For a vertical atmospheric aerosol distribution measurement, a very compact and light particle sampling package is developed. This package includes a compact optical particle counter (Hy-OPC), a light and small condensation particle counter (Hy-CPC), sensors (GPS, wind velocity, temperature, humidity), and a communication and system control board. This package is attached to He balloon and the altitude is controlled by a winch. Using this system the vertical particle size distribution was measured. The test results showed that the ground base atmospheric particle measurement result may be a lot different from that high above the ground.

도심 내 버스정류장 부근의 에어로졸 입자 크기 및 형상 관찰 (A Study on the Shapes of Aerosol Particles at a Bus Stop in the Eastern Part of Seoul)

  • 정상빈;허기준;신창훈;조원경;이병욱
    • 한국입자에어로졸학회지
    • /
    • 제12권4호
    • /
    • pp.109-114
    • /
    • 2016
  • People in metropolitan cities can be exposed to particulate air pollutants at public transportation systems such as bus stops. In this study, we sampled aerosol particles with an impactor at a bus stop. We analyzed the shapes of these particles with an optical microscope. It was estimated that fibers, silicons, byproducts of combustion, and pollens existed in the air environments at the bus stop with analysis of shapes of sampled particles.

에어로졸 시험장비를 이용한 방호 의복 소재의 여과 효율에 대한 연구 (The Experimental Study of SPM(Selectively Permeable Membrane Materials) by using Aerosol Test Instrument)

  • 권태근;서현관;김진원;강재성;강기태;안강호;최진수;조재호;권용택;박현배
    • 한국입자에어로졸학회지
    • /
    • 제10권3호
    • /
    • pp.109-117
    • /
    • 2014
  • In Korea, permeable protection clothes for chemical agent is being developed and distributed. But permeable protection clothes are vulnerable for biological agent of particle type. Therefore selective permeable membranes are being developed to protect chemical agent and biological agent simultaneously. In this study, aerosol collection efficiency test was performed to validate the protection performance of permeable clothes and selective permeable membranes. Aerosol collection efficiency test was performed by using the aerosol test equipment that could test aerosol particle diameter from $0.005{\mu}m$ to $3.0{\mu}m$. This study shows the test method and performance test results for collection efficiency by using the aerosol test equipment.

광학적 입자계수기를 이용한 2004년 황사기간 인천지역 에어로졸 특성 (Characteristics of Incheon Aerosol during Asian Dust Period in 2004 using Optical Particle Counter (OPC))

  • 정창훈;조용성;이종태
    • 한국환경과학회지
    • /
    • 제14권6호
    • /
    • pp.565-575
    • /
    • 2005
  • The characteristics for the aerosol number distribution was studied during spring, 2004 in Incheon. Optical Particle Counter (OPC, HIAC/ROYCO 5230) was used in order to measure the number concentration of aerosol in the range of $0.3\~25{\mu}m.$. The obtained results were compared with $PM_{2.5}\;and\;PM_{10}$ data during Asian dust events. The results show that the size resolved aerosol number concentration from OPC measurement has a similar tendency with $PM_{10}\;and\;PM_{2.5}$ mass concentration. During Asian dust periods, the number concentrations in large particle $(CH5\~CH8)$ increase more than small particles which diameter is less than $2.23{\mu}m(CH5)$ and the same results were shown when $PM_{10}$ was compared with $PM_{2.5}$ data compared with non-dust days, Consequently, this study shows that size resolved aerosol number concentration from OPC measurement can be used as a useful tool in comparison of mass concentration data.

패러데이 케이지와 에어로졸 하전기의 설계 및 성능평가 (Design and Performance Evaluation of a Faraday Cage and an Aerosol Charger)

  • 지준호;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.315-323
    • /
    • 2004
  • An electrical cascade impactor is a multi-stage impaction device to separate airborne particles into aerodynamic size classes using particle charging and electrical detection techniques. A Faraday cage and an aerosol charger, which are basic components of the electrical cascade impactor, were designed and evaluated in this study. The low-level current response of the Faraday cage was investigated with changing particle size and air flow rate by using sodium chloride (NaCl) particles. The response of the prototype Faraday cage was very similar to that of a commercial aerosol electrometer (TSI model 3068) within ${\pm}$5% for singly-charged particles. The response linearity of the prototype Faraday cage could be extended up to flow rate of 30 L/min. For the performance evaluation of the aerosol charger the monodisperse liquid dioctyl sebacate (DOS) particles, with diameters of 0.1∼0.8$\mu\textrm{m}$, were generated using spraying from an atomizer followed by evaporation-condensation process. Typical performance parameters of the aerosol charger such as P$.$n, wall loss, and elementary charges per particle were evaluated. The performance of the prototype aerosol charger was found to be close to that of the aerosol charger used in an electrical low pressure impactor (ELPI, Dekati).

Generation of Model Diesel Particles by Spark Discharge and Hydrocarbon Condensation

  • Kim, Hak-Joon;Kim, Jin-Ho;Choi, Young-Joo;Oh, Hyen-Chul;Chu, Jung-Bum;Kim, Sang-Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제20권11호
    • /
    • pp.1972-1979
    • /
    • 2006
  • This study was conducted in order to generate model particles which were similar to particles in diesel emission. Spark discharge was used for carbon agglomerates and hydrocarbon condensation for particles that consist of carbon agglomerates and hydrocarbon. The size of the carbon agglomerates, whose mean size were 30 and 70 nm, ranged between 15 and 200 nm, and the total number concentration of the particles ranged from 3 to $5{\times}10^7#/cm^3$ as the controllable variables in spark discharge generator changed. The result of the hydrocarbon condensation experiment showed that the final sizes of the particles enlarged by condensation did not depend on the initial sizes, but the maximum condensational growth of carbon agglomerates by dodecane ($C_{12}H_{26}$) condensation was 112 times the initial size of 40 nm, while the size of the agglomerates by benzene ($C_6H_6$) was 3.25 times its initial size.

Recent Development of Analytical Solutions to Brownian Aerosol Coagulation in Different Particle Size Regimes

  • Park, Seong-Hun;Kim, Hyun-Tae;Lee, Kyoo-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제15권E호
    • /
    • pp.65-71
    • /
    • 1999
  • The log-normal size distribution theories developed recently for aerosol coagulation are reviewed. The analytical solutiosn to Brownian coagulation developed recently for various particle size regimes are reviewed. In order to describe the evolution of the size distribution of a coagulating aerosol over the entire size range, the analytical solutions developed individually for the free-molecule regime, the transition regime, the nearcontinuum regime, and the continuum regime have been combined. The work described here represents the first analytical solution to the aerosol coagulation problem covering the entire particle size range.

  • PDF

Investigation of Aerosol Number Concentration at Gosan Site in Jeju, Korea

  • Kang, Chang-Hee;Hu, Chul-Goo
    • 한국환경과학회지
    • /
    • 제21권1호
    • /
    • pp.23-30
    • /
    • 2012
  • The aerosol number concentration have measured with an aerodynamic particle sizer spectrometer(APS) at Gosan site in Jeju, Korea, from March 2010 to March 2011. And then the atmospheric aerosol number concentration, the temporal variation and the size distribution of aerosol number concentration have been investigated. The aerosol number concentration varies significantly from 748 particles/$cm^3$ to zero particles/$cm^3$. The average number concentration in small size ranges are very higher than those in large size ranges. The number concentrations in the size range 0.25~0.28 ${\mu}m$, 0.40~0.45 ${\mu}m$ and 2.0~2.5 ${\mu}m$ are about 84 particles/$cm^3$, 2 particles/$cm^3$ and 0.4 particles/$cm^3$, respectively. The number concentrations in range of larger than 7.5 ${\mu}m$ are below 0.001 particles/$cm^3$. The seasonal variations in the number concentration for smaller particle(<1.0 ${\mu}m$) are not much, but the variations for larger particle are very evident. And strong amplitudes of diurnal variations of entire averaged aerosol number concentration are not observed. Size-fractioned aerosol number concentrations are dramatically decreased with increased particle size. The size-fractioned aerosol number concentrations in size range 0.8~4.0 ${\mu}m$ during nighttime are evidently higher than during daytime, but similar levels are appeared in other size range. The seasonal differences in the size-fractioned number concentrations for smaller size range(<0.7 ${\mu}m$) are not observed, however, the remarkable seasonal differences are observed for larger size than 0.7 ${\mu}m$.