• 제목/요약/키워드: Adjustable

검색결과 842건 처리시간 0.036초

조향 자기변형 트랜스듀서를 이용한 평판 결함진단 (Damage Detection in a Plate Using an Orientation-adjustable Magnetostrictive Transducer)

  • 조승현;이주승;선경호;김윤영
    • 한국소음진동공학회논문집
    • /
    • 제15권1호
    • /
    • pp.81-86
    • /
    • 2005
  • In this work, we propose a new ultrasonic damage inspection method in plate structures. The proposed method employs an OPMT(orientation-adjustable patch-type magnetostrictive transducer) in order to make the ultrasonic waves directed to a specific target point. For experiments, virtual grid points were set up at every 50 mm in an aluminum plate and two OPMTs were used for inspection. If there exists a crack in a plate, the reflected Lamb wave from the crack is measured in addition to the direct waves from the transmitting transducer to the receiving transducer.

The treatment of lower extremity defects with severe proliferative tissue using an adjustable horizontal mattress suture in a Tosa dog

  • Heo, Suyoung;Kim, Namsoo
    • 대한수의학회지
    • /
    • 제54권2호
    • /
    • pp.121-122
    • /
    • 2014
  • A 2-year-old male Tosa was admitted for treatment of a non-healing wound on the right forelimb. Skin tests were unremarkable; however, the lesion contained severe proliferative tissue. Surgical treatment was conducted due to the extensive skin defect and granulation tissue present. Following removal of the proliferative tissue, the wound was closed using the adjustable horizontal mattress suture method with multiple punctate relaxing incisions. The proliferative tissue healed completely after the surgical treatment. This technique can be considered an alternative treatment for the proliferative tissue when conditions require a skin graft or flap after surgical treatment.

발전소 대용량 FD Fan 전동기의 교류 가변속 장치 (VVVF) 적용에 관한 연구 (Research Study on the Application of AC Adjustable speed Drive for FD Fan Motor in power plant.)

  • 허성광;류홍우;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1203-1205
    • /
    • 1992
  • Due to poor energy resources, the importance of energy saving has been greatly emphasized. It can be one method of energy saving to reduce the power. The AC adjustable speed drive systems show excellent efficiency, which have been developed in recent years. The adjustable speed drive system improves the efficiency in lightly load condition and extend the life span of motor by limiting the over-current at starting. The main topic of study is the results of energy saving and emergency transfer.

  • PDF

궤간 가변 윤축의 압축스프링에 대한 강도해석 (Strength Analysis for Compressed Coil Spring in the Gage - Adjustable Wheelset System)

  • 김철수;안승호;정광우;장승호;장국진;김정규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1012-1017
    • /
    • 2007
  • To reduce the cost and the time of transport in Eurasian railroad networks such as TKR(Trans-Korea Railway), TCR(Trans-China Railway) and TSR(Trans-Siberia Railway) owing to the problem of different track gauges (narrow/standard/broad gauge), it is important to develop the gauge - adjustable wheelset system to adapt easily to these gauges. Moreover, this system accomplishes periodically a conversion operation from the gauge variable segment between different gauge. Gauge adjustable compression coil spring during conversion process accomplishes repetitively a central role for operation mechanism between flange and locking part. Therefore, to assure the safety of the gauge-adjustment wheelset system, it is necessary to stress analysis of the optimized spring in the system. In this study, it was performed to optimal design of the spring for stress analysis by using the genetic algorithm.

  • PDF

가변속 전력구동시스템 관련 특수 시험방법을 포함한 EMC 제품규격에 관한 연구 (A Study on EMC Product Standard Including Specific Test Methods Related to Adjustable Speed Electrical Power Drive Systems)

  • 홍순찬;서영민;김경원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.99-103
    • /
    • 2002
  • IEC 61800 is an international standard on adjustable speed electrical power drive systems, which consists of three parts. IEC 61800-1 and IEC 61800-2 apply to DC power drive systems and AC power drive systems, respectively, which include power conversion, control equipment, and also a motor or motors. IEC 61800-3 specifies EMC ( Electro Magnetic Compatibility ) requirements for adjustable speed AC or DC motor drives connected to main supplies up to AC 1,000 volts. This paper studies the standards related to EMC and the text summary of international standard IEC 61800-3 which is an EMC product standard including specific test methods.

  • PDF

스캐닝 시스템과 하악용 가변형 트레이의 재현성 (Scanning System and Reproduction of Adjustable Lower Dental Impression Tray)

  • 차영엽;엄상호
    • 제어로봇시스템학회논문지
    • /
    • 제17권3호
    • /
    • pp.254-257
    • /
    • 2011
  • This study was performed to development a dental three-dimensional laser scanning system and measure the accuracy of new adjustable lower dental impression trays. Multiple impressions of a resin master model were made with custom, stock and new adjustable trays and vinyl polysiloxane impression material. The lower master model and resulting cast were compared using an dental scanning system. Each 3D image was superimposed onto the lower master model image and analyzed with custom software. Multiple measurements of the lower master model and casts were analyzed to determine the accuracy of tray types.

배선용 차단기 순시 가조정 트립부 개발에 관한 연구 (Researchs for the Development of MCCB adjustable Instant Trip Unit)

  • 송중천;유만종;김길수;강종성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.354-356
    • /
    • 1999
  • Through the Standard of MCCB, the Adjustable Type Instant Trip Unit should NO trip at -20% of each current from $5{\times}In$ to $10{\times}In$ and trip +20% of those. In this paper, we obtain the attraction force between Fixing Magnet and Moving Armature. So we first made some samples. do experiments of weight, and simulated the modelling by 3D Maxwell S/W. With values of experiment and simulated values, we do design instant trip springs by using the ADAMS S/W of kinematic simulation. Finally we product the 250A Adjustable Instant Trip Unit, and it is very useful to our customers.

  • PDF

Induction Motor with Adjustable Windings for High Efficiency Drive in Light Load Operation

  • Zhang, Y.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.508-513
    • /
    • 2014
  • Heavy load start but light load operation is a common case in practical drive applications. When an induction motor is employed for such applications, its rated power is usually chosen according to the heavy load start. Then, during light load operation, its efficiency and power factor are low. To solve this problem, it is proposed to adjust the motor windings from the startup to the normal operation conditions. In this paper, arrangement of the adjustable windings is introduced, air gap field with different windings is investigated, and steady state operation performance under various loads is examined. It can be seen that by using proper winding arrangement both startup and operation performances are satisfactory.

Optical Signal Sampling Based on Compressive Sensing with Adjustable Compression Ratio

  • Zhou, Hongbo;Li, Runcheng;Chi, Hao
    • Current Optics and Photonics
    • /
    • 제6권3호
    • /
    • pp.288-296
    • /
    • 2022
  • We propose and experimentally demonstrate a novel photonic compressive sensing (CS) scheme for acquiring sparse radio frequency signals with adjustable compression ratio in this paper. The sparse signal to be measured and a pseudo-random binary sequence are modulated on consecutively connected chirped pulses. The modulated pulses are compressed into short pulses after propagating through a dispersive element. A programmable optical filter based on spatial light modulator is used to realize spectral segmentation and demultiplexing. After spectral segmentation, the compressed pulses are transformed into several sub-pulses and each of them corresponds to a measurement in CS. The major advantage of the proposed scheme lies in its adjustable compression ratio, which enables the system adaptive to the sparse signals with variable sparsity levels and bandwidths. Experimental demonstration and further simulation results are presented to verify the feasibility and potential of the approach.

유지형태에 따른 가변형 치과 인상용 트레이의 유지력에 관한 연구 (RETENTIVE FORCE OF ADJUSTABLE DENTAL IMPRESSION TRAYS WITH DIFFERENT RETENTION FORMS)

  • 송기범;김성록;박광수;김유리;동진근
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.15-29
    • /
    • 2005
  • Statement of problem. The adjustable dental impression trays were made for being adjusted their width automatically along the width of dental arch. Purpose. The purpose of this study was to investigate the best retentive form of adjustable dental impression tray, and so to make it a more satisfactory product. Material and methods. The eight pairs of adjustable trays were made of ABS(acrylonitrile butadiene styrene) with different distribution of holes and with or without the rim on the border area of them. The experiment was done with the horse-shoe shaped metal plate to pull out the set impression body from the tray, and the tray jig which was made for holding the tray on a lower part of Universal Testing Machine(UTM, Zwick Z020, Zwick Co., Germany). After the impression in the tray was allowed to set four minutes, a tensile force was applied at right angles to the tray which had been previously seated on the jig. The force was applied to measure a maximum retentive force by use of a UTM at a constant strain rate of 100mm per minute. A 2-factor analysis of variance (p<.05) was used to determine whether differences existed among distribution of retentive holes and between rim existing and not. Results. 1 The retentive force of the upper and lower resin tray with 2mm holes on the tray border was highest(25.83/24.98kg). (p<.05) 2. As the tray had more retentive holes, it was less retentive. 3. There was no significant difference in the retentive force of the varied hole intervals in the case of distributing all the area. (p>.05) 4. The rimless trays were more retentive generally, than the rimmed trays except 2 case: upper tray group-all area / 2 mm, intervals and lower tray group-margin only / 2 mm, intervals.(p<.05) 5. Most of the adjustable trays were showed higher retentive force than perforated metal tray except the lower group that perforated on the all area at intervals of 2 mm.