References
- Zarb GA. Bolender CL, Hickey JC, Carlsson GE. Boucher's Prosthetic Treatment for Edentulous Patients. 10th ed. St Louis:CV Mosby Co., 150-151. 1990
- Myers GE, Stockman DG. Factors that affect the accuracy and dimensional stability of the mercaptan rubber-base impression materials. J Prosthet Dent 1960;10:525-535 https://doi.org/10.1016/0022-3913(60)90016-0
- Stackhouse Jr JA. The accuracy of stone dies made from rubber impression materials. J Prosthet Dent 1970;24:377-386 https://doi.org/10.1016/0022-3913(70)90078-8
- Shigeto N. Murata H. Hamada T. Evaluation of the methods for dislodging the impression tray affecting the dimensional accuracy of the abutments in a complete dental arch cast. J Prosthet Dent 1989;61:54-58 https://doi.org/10.1016/0022-3913(89)90109-1
- Mendez AJ. The influence of impression trays on the accuracy of stone casts poured from irreversible hydrocolloid impressions. J Prosthet Dent 1985;54:383-388 https://doi.org/10.1016/0022-3913(85)90557-8
- Song DS. Jin TH, Dong JK. A study on the fitness of stock tray in Korean adults. J Korea Acad Proshtodont 1989;27:131-140
- Song DS, Kang SK. Cho HW, Dong JK. Development of dentulous stock trays for Koreans. J Korea Acad Proshtodont 1996;34:755-778
- Shin SJ, Park JY, Oh SC, Dong JK. A study on the fitness of dentulous stock tray designed for Korean. Journal of Wonkwang Dental Research Institute 1997;7:193-209
- Dong JK. Oh SC, Kim MJ. Development of adjustable dental impression trays. 10th Meeting of the International College of Prosthodontists. Halifax, Canada. 2003 ;abstract No.51
- Jordan LG. Alginate Impression Materials. J Am Dent Assoc 1945;32:985-986 https://doi.org/10.14219/jada.archive.1945.0128
- Atkinson HF, Gill HI, and Shepherd RW. Some notes on alginate impression material. Austrailian Dent J 1958;3:184-185 https://doi.org/10.1111/j.1834-7819.1958.tb01835.x
- Wilson HJ, Smith DC. The bonding of alginate impression materials to impression trays. Brit Dent J 1963;115:291-294
- Phillips RW. Skinner's science of dental materials. 8th ed. Philadelphia: WB Saunders Co., 149-156, 1982
- Fusayama T, Nakazato M. The design of stock trays and the retention of irreversible hydrocolloid impressions. J Prosthet Dent 1969;21:136-142 https://doi.org/10.1016/0022-3913(69)90086-9
- Kaloyannides TM. Christidou L. Elasticity of impression materials:IV Permanent deformation as a function of time. J Dent Res 1975;54:168-173 https://doi.org/10.1177/00220345750540011401
- Morrow RM, Brown Jr CE, Powell JM, Rudd KD. Compatibility of alginate impression materials and dental stones. J Prosthet Dent 1971;25:556-566 https://doi.org/10.1016/0022-3913(71)90214-9
- Lee SH. A study on the accuracy of rubber impression materials. J Korean Dent Assoc 1983;21:237-243
- Kim KN. Alginate impression materials. The Korea Research Society for Dental Materials 1986;13:27-32
- Ansari IH. Making a custom tray for elastomeric impression materials without a primary cast. J Prosthet Dent 1994;72:569-571 https://doi.org/10.1016/0022-3913(94)90132-5
- Milward PJ. Murphy WM. Custom. impression trays with a new hypoallergenic material. J Prosthet Dent 1994;72:572-573 https://doi.org/10.1016/0022-3913(94)90133-3
- Rehberg HJ. The impression tray - an important factor in impression precision. Int Dent J 1977;27:146-153
- Breeding LC. Dixon DL. Moseley JP. Custom impression trays: part I- Mechanical properties. J Prosthet Dent 1994;71:31-34 https://doi.org/10.1016/0022-3913(94)90252-6
- Mitchell JV. Damele JJ. Influence of tray design upon elastic impression materials. J Prosthet Dent 1970;23:51-57 https://doi.org/10.1016/0022-3913(70)90163-0
- Asgar K. Elastic impression materials. Dent Clin North Am 1971;15:81-98
- Linke BA, Nicholls JI. Faucher RR. Distortion analysis of stone casts made from impression materials. J Prosthet Dent 1985;54:794-802 https://doi.org/10.1016/0022-3913(85)90473-1
- Phillips RW, Schnell RJ. Dimensional stability of rubber base impressions and certain other factors affecting accuracy. J Am Dent Assoc 1958;57:39-48 https://doi.org/10.14219/jada.archive.1958.0248
- Reisbick MH, Matyas J. The accuracy of highly filled elastomeric impression materials. J Prosthet Dent 1975;33:67-72 https://doi.org/10.1016/S0022-3913(75)80148-X
- Ryu SI, Chang IT. Kim KN. The influence of impression trays on the accuracy of the stone casts poured from completearch impressions. J Korea Acad Proshtodont 1992;30:1-13
- Smith SJS. McCord JF. Macfarlane TV. Factors that affect the adhesion of two irreversible hydrocolloid materials to two custom tray materials. J Prosthet Dent 2002;88:423-430 https://doi.org/10.1067/mpr.2002.128746
- Ellam AH, Smith DC. The relative effectiveness of adhesives for polysulphide impression materials. Brit Dent J 1966;120:135-138
- Chai JY. Jameson LM. Moser JB. Hesby RA. Adhesive properties of several impression material systems: part I. J Prosthet Dent 1991;66:201-209 https://doi.org/10.1016/S0022-3913(05)80048-4
- Nishigawa G. Sato T. Suenaga K, Minagi S. Efficacy of tray adhesives for the adhesion of elastomer rubber impression materials to impression modeling plastics for border molding. J Prosthet Dent 1998;79:140-144 https://doi.org/10.1016/S0022-3913(98)70207-0
- Choi MH. Shin DK, Kim MJ. Oh SC. Dong JK. Retentive force of dental impression tray according to retention form. Korea Academy of Stomatognathic Function and Occlusion 2004;20:43-50