• 제목/요약/키워드: Adiabatic Performance

검색결과 172건 처리시간 0.026초

초전도 마그네트용 영구전류스위치의 제작 및 성능 평가 (Fabrication and performance test of persistent current switch for superconducting magnet)

  • 고락길;배준한;심기덕;이언용;권영길;류강식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.189-192
    • /
    • 2001
  • In order to design thermally trigger controlled persistent current switch (PCS) for superconducting magnet system, it is very important to know information of applied adiabatic method and condition to get designed resistance and characteristics In this paper, we used cotton-gummed tape as thermal insulator and derived experimentally averaged thermal conductivity of it around 10K on the assumption that adiabatic structure of PCS is shape of pipe. The result value is about 0.29 W/mK and it is verified reasonable value by computer simulation and experiment of test PCS. Test PCS was designed and manufactured different dimensions. The experimental results of test PCS were in good agreement with the calculated results.

  • PDF

케이싱 그루브가 장착된 천음속 축류압축기의 작동 안정성 향상을 위한 수치최적화 (Numerical Optimization of a Transonic Axial Compressor with Casing Grooves for Improvement of Operating Stability)

  • 김진혁;최광진;김광용
    • 한국유체기계학회 논문집
    • /
    • 제14권5호
    • /
    • pp.31-38
    • /
    • 2011
  • Optimization using a hybrid multi-objective evolutionary algorithm coupled with response surface approximation has been performed to improve the performance of a transonic axial compressor with circumferential casing grooves. In order to optimize the operating stability and peak adiabatic efficiency of the compressor with circumferential casing grooves, tip clearance, angle distribution at blade tip and the depth of the circumferential casing grooves are selected as design variables. Three-dimensional Reynolds-averaged Navier-Stokes equations with the shear stress transport turbulence model are discretized by finite volume approximations. The trade-off between two objectives with the interaction of blade and casing treatment is determined and discussed with respect to the representative clusters in the Pareto-optimal solutions compared to the axial compressor without the casing treatment.

비단열 모세관의 형상 변경에 따른 소형 냉동 사이클 성능 해석 (Simulation of the small Refrigeration Cycle as shape change of the Non-Adiabatic Capillary Tube)

  • 남기원;이대용;박상구;정지환;김윤수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.550-555
    • /
    • 2009
  • The present simulation focuses on the effect of the shape of capillary tube-suction line heat exchangers(SLHX), The results in the three cases of the SLHX types show that both of the location and length of heat exchange section influence the coefficient of performance(COP) and cooling capacity. Simulation shows the COP may be improved by 4.6% and the cooling capacity may be improved by 13.6% in the Lateral type.

  • PDF

가중평균대리모델을 사용한 천음속 압축기 블레이드 최적화 (Blade Optimization of a Transonic Compressor Using a Multiple Surrogate Model)

  • 압두스 사마드;최재호;김광용
    • 대한기계학회논문집B
    • /
    • 제32권4호
    • /
    • pp.317-326
    • /
    • 2008
  • The main purpose of the present study is to perform shape optimizations of transonic compressor blade in order to enhance its performance. In this study, the Latin hypercube sampling of design of experiments and the weighted average surrogate model with the help of a gradient based optimization algorithm are used within design space by the lower and upper limits of each design variable and for finding optimum designs, respectively. 3-D Reynolds-averaged Navier-Stokes solver is used to evaluate the objective functions of adiabatic efficiency and pressure ratio. Six variables from lean and airfoil thickness profile are selected as design variables. The results show that the adiabatic efficiency is enhanced by 1.43% by efficiency optimization while the pressure ratio is increased very small, and pressure ratio is increased by 0.24% by pressure ratio optimization.

저발열 결합재 및 CGS를 잔골재로 치환한 매스콘크리트의 수화열 해석 (Hydration Heat Analysis of Mass Concrete Replacement of Low Heat Binder and CGS with Fine Aggregate)

  • 한준희;임군수;최일경;윤치환;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.235-236
    • /
    • 2021
  • This study evaluated temperature distribution through adiabatic temperature rising test and hydration heat Analysis as a performance verification to utilize CGS as a hydration heat reduction material for mass concrete when replacing it with fine aggregate. According to the analysis, the temperature difference between the center and the surface was the highest at about 30℃, followed by the CGS 50% at 26℃ and the low heat combiner FA 30% at 23℃.

  • PDF

국내 발전소 지붕방수설계 시스템 및 단열 성능에 관한 연구 (A Study on the domestic power plant roof waterproofing system & insulation efficiency)

  • 정광호
    • 한국디지털건축인테리어학회논문집
    • /
    • 제11권1호
    • /
    • pp.33-42
    • /
    • 2011
  • As the development of construction technology and new materials, building requirements has been varied gadually. Comfortable environment and serviceability of production activity and energy conservation are being dealt with very seriously. Recently localization of engineering technology of Power Plant, however, construction materials and domestic technology are being developed forcingly. According to above topics this thes is going to study roof waterproofing, thermal insulation and evaluate adiabatic performance and evaluation of properties of waterproofing materials and energy conservation. The results of studying and evaluating of roof waterproofing, thermal insulation and adiabatic performance of Power Plant are as follows. 1. Sheet waterproofing method is better than that of asphalt waterproofing method in that adaptability of wearhertight, thermal resistant, contraction and expansion. 2. It is required to replace polyurethane or ethylene used as thermal insulation with rock wool which is noncombustible materials. 3. It is recommended to usd outer insulation method than inner insulation method due to superioty of outer insulation method. Efficiency of insulation materials used in power plant is generally good except perlite mortar used in the power plant(YGN 1-2, GRI 1-2).

금속 장갑재료의 개발기술 및 발전전망 (Technological Review on the Development of Metallic Armor Materials)

  • 김홍규;홍성석;심인옥
    • Composites Research
    • /
    • 제24권2호
    • /
    • pp.46-50
    • /
    • 2011
  • 이 논문은 전투차량의 주 장갑재료로 사용되는 금속장갑재료의 개발현황 및 방탄성능에 영향을 미치는 조직학적 요인들을 중심으로 방탄성 향상을 위한 요소기술을 살펴보고, 향후 금속장갑재의 발전전망에 대하여 서술하였다. 금속장갑재는 요구되는 방호특성에 따라 사용되는 합금계가 다르지만 강도와 인성을 최적화하여 위협 탄에 대한 관통저항성 및 취성파단에 대한 저항성을 극대화하는 것이 필요하며, 이를 위해서는 금속재료의 방탄조건에서 특정적으로 나타나는 단열전단현상을 이해하고 적절히 제어하는 기술이 요구된다.

고유동포틀랜드시멘트를 이용한 고성능콘크리트의 기초적 특성에 관한연구 (A Fundamcntal Study on the Propertice of High Performance Concrete using High Flowable Portland Cement)

  • 홍성윤;김병권;박춘근;조동원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.45-49
    • /
    • 1995
  • The fundamental properties of High Performance Concrete(HPC) were studied using high flowable portland cement which was developed at the Sangyong Cement Ind. Co.,Ltd. The results obtained are as follows. (1)The slump of HPC using high flowable portland cement maintains for 120min. (2)Ultra high strength greater than 800kg/$\textrm{cm}^2$ can be designed without using silica fume and other additives. (3)The value of drying shrinkage and adiabatic temperature rise of HPC are less than those of concrete made with OPC.

  • PDF

매시브한 해양구조물 적용을 위한 고로슬래그 혼입 콘크리트의 방청성능 평가에 관한 연구 (A Study on the Estimation of Corrosion Protection Performance of Concrete Containing Ground Granulated Blast-Furnace Slag for Massive Coastal Structures)

  • 유재강;김동석;박상준;원철;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술.기술논문발표회
    • /
    • pp.87-91
    • /
    • 2002
  • This paper investigates the corrosion inhibition and the reduction of hydration heat properties of Ground Granulated Blast-Furnace Slag (GGBFS) added concrete. Since the massive civil structure is vulnerable to the thermal crack by hydration. adiabatic temperature rising tests were performed for water-binder ratios from 43.2% to 47.3%, while replacing 15% to 50% of cement with GGBFS of equal weight. Then, the corrosion protection performance was evaluated using cylindrical specimens embedded with steel reinforcement according to the combination of 3 W/B ratios and 2 levels of chloride ion quantity. The corrosion area of the embedded steel ban was determined using the high pressure steam curing method specified in KS F 2561. The test results showed that the replacement of GGBFS was effective in reducing the hydration heat. The corrosion area of the embedded steel ban decreased as the replacement of GGBFS increased. However, the corrosion area of the steel bar was proportional to the autoclave cycle and the chloride ion quantity. Among the tested specimens, compressive strength, reduction of hydration heat, and corrosion inhibition performance were excellent when 50% of cement was replaced with GGBFS of equal weight.

  • PDF

$CO_2$ 2단 트윈 로타리 압축기 성능해석 (Performance Analysis of a $CO_2$ Two-Stage Twin Rotary Compressor)

  • 김우영;안종민;김현진;조성욱
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.19-27
    • /
    • 2007
  • Analytical investigation on the performance of a two stage twin rotary compressor for $CO_2$ heat pump water heater system has been carried out. A computer simulation program was made based on analytical models for gas compression in control volumes, leakages among neighboring volumes, and dynamics of moving elements of the compressor. Calculated cooling capacity, compressor input, and COP were well compared to those of experiments over the compressor speeds tested. For the operating condition of suction pressure of 3 MPa, and discharge pressure of 9 MPa, and compressor inlet temperature of $35^{\circ}C$, the compressor efficiency was calculated to be 80.2%: volumetric, adiabatic, and mechanical efficiencies were 88.3%, 93.2%, and 92.7%, respectively. For the present compressor model, volumetric and adiabatic efficiencies of the second stage cylinder were lower by about $6{\sim}7%$ than those of the first stage mainly due to the smaller discharge port at the second stage. Parametric study on the discharge port size showed that the compressor performance could be improved by 3.5% just by increasing the discharge port diameter by 20%.