• Title/Summary/Keyword: Adhesive-bonding

Search Result 768, Processing Time 0.031 seconds

STUDY ON DENTINAL TUBULES SEALING EFFECTS OF DENTIN BONDING AGENTS (DENTIN BONDING AGENTS들의 상아세관 밀봉 효과에 관한 연구)

  • Kown, O-Teak;Park, Dong-Soo
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.483-496
    • /
    • 1993
  • Dentin hypersensitivity medicaments such as Gluma, Scotchbond 2, All-Bond 2, which are resin adhesives, were used to compare the sealing effects of dentinal tubule under mechanical stress. Topical application of above medicaments on the dentin surfaces of extracted teeth followed by artificial tooth brushing for 6 weeks was performed for the comparison. The following conclusions on the degree of dentinal tubule exposure versus time by were reached by using polyvinyl siloxane impression material for taking the impression, epoxy resin for the duplication and SEM for observing the surface. 1. SEM was used to compare the accuracy of the duplicated surface, but no differences were found when teeth samples and the duplicated surfaces were observed. 2. After comparing the degree of dentinal tubules exposure with varnish applied contrast group, resin adhesive materials showed much less exposure as time went by. 3. The results indicated that AU-Bond 2 adhesive, under mechanical stress, showed lesser exposure of dentinal tubules comparing with Gluma and Scotchbond 2 adhesives After the results were put together, it was demonstrated that resin replica method is an useful way to evaluate the treatment effects of the dentinal tubule hypersensitivity medicaments. Also, it was noticed that under mechanical stress, All-Bond 2, classified as fourth generation, illustrated the best dentinal tubules sealing effects.

  • PDF

Preparation and Properties of Waterborne Poly(urethane-urea) Ionomers -Effect of the Type of Neutralizing Agent-

  • Yang, Jung-Eun;Lee, Young-Hee;Koo, Young-Seok;Jung, Young-Jin;Kim, Han-Do
    • Fibers and Polymers
    • /
    • v.3 no.3
    • /
    • pp.97-102
    • /
    • 2002
  • A series of waterbome poly(urethane-urea) anionomers were prepared from isophorone diisocyanate (IPDI), polycaprolactone diol (PCL), dimethylol propionic acid (DMPA), ethylene diamine (EDA), and triethylamine (TEA), NaOH, or Cu($(COOCH_3)_2$) as neutralizing agent. This study was performed to decide the effect of neutralizing agent type on the particle size viscosity, hydrogen bonding index, adhesive strength, antistaticity, antibacterial and mechanical properties. The particle size of the dispersions decreased in the following order: TEA based samples (T-sample), NaOH based samples (N-sample), and Cu($(COOCH_3)_2$) based sample (C-sample). The viscosity of the dispersions increased in the order of C-sample, N-sample, and T-sample. Metal salt based film samples Of and C-sample) had much higher antistaticity than TEA based sample. By infrared spectroscopy, it was found that the hydrogen bonding index (or fraction) of samples decreased in the order of T-sam-pie, N-sample, and C-sample. The adhesive strength and tensile modulus/strength decreased in the order of T-sample, N-sam-pie, and C-sample. The C-sample had strong antibacterial halo, however, T- and N-samples did not

Do universal adhesives promote bonding to dentin? A systematic review and meta-analysis

  • Elkaffas, Ali. A.;Hamama, Hamdi H.H.;Mahmoud, Salah H.
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.3
    • /
    • pp.29.1-29.13
    • /
    • 2018
  • Objectives: The aims of this study were to conduct a systematic review of the microtensile bond strength (${\mu}TBS$) of multi-mode adhesives to dentin and to perform a meta-analysis to assess the significance of differences in the ${\mu}TBS$ of one of the most commonly used universal adhesives (Scotchbond Universal, 3M ESPE) depending on whether the etch-and-rinse or self-etch mode was used. Materials and Methods: An electronic search was performed of MEDLINE/PubMed, ScienceDirect, and EBSCOhost. Laboratory studies that evaluated the ${\mu}TBS$ of multi-mode adhesives to dentin using either the etch-and-rinse or self-etch mode were selected. A meta-analysis was conducted of the reviewed studies to quantify the differences in the ${\mu}TBS$ of Scotchbond Universal adhesive. Results: Only 10 studies fulfilled the inclusion criteria for the systematic review. Extensive variation was found in the restorative materials, testing methodologies, and failure mode in the reviewed articles. Furthermore, variation was also observed in the dimensions of the microtensile testing beams. The meta-analysis showed no statistically significant difference between the etch-and-rinse and self-etch modes for Scotchbond Universal adhesive (p > 0.05). Conclusions: Multi-mode 'universal' adhesives can achieve substantial bonding to dentin, regardless of the used modes (either etch-and-rinse or self-etch).

A COMPARISON OF FRACTURE STRENGTHS OF PORCELAIN-FUSED-TO-TITANIUM CROWN AMONG TITANIUM SURFACE COATING TREATMENTS (타이타늄 표면 코팅 처리에 따른 타이타늄도재관의 파절강도 비교)

  • Kim, Ji-Hye;Park, Sang-Won;Vang, Mong-Sook;Yang, Hong-So;Park, Ha-Ok;Lim, Hyun-Pil;Oh, Gye-Jeong;Kim, Hyun-Seung;Lee, Kwang-Min;Lee, Kyung-Ku
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.203-215
    • /
    • 2007
  • Statement of problem: Titanium and its alloy, with their excellent bio-compatibility and above average resistance to corrosion, have been widely used in the field of dentistry. However, the excessive oxidization of titanium which occurs during the process of firing on porcelain makes the bonding of titanium and porcelain more difficult than that of the conventional metal-porcelain bonding. To solve this problem related to titanium-porcelain bonding, several methods which modify the surfaces, coat the surfaces of titanium with various pure metals and ceramics, to enable the porcelain adhesive by limiting the diffusion of oxygen and forming the adhesive oxides surfaces, have been investigated. Purpose: The purpose of this study was to know whether the titanium-porcelain bonding strength could be enhanced by treating the titanium surface with gold and TiN followed by fabrication of clinically applicable porcelain-fused-to-titanium crown Material and method: The porcelain-fused-to-titanium crown was fabricated after sandblasting the surface of the casting titanium coping with $Al_2O_3$ and treating the surface with gold and TiN coating followed by condensation and firing of ultra-low fusing porcelain. To compare with porcelain-fused-to-titanium crowns, porcelain-fused-to-gold crowns were fabricated and used as control groups. The bonding strengths of porcelain-fused-to-gold crowns and porcelain-fused-totitanium crowns were set for comparison when the porcelain was fractured on purpose to get the experimental value of fracture strength. Then, the surface were examined by SEM and each fracturing pattern were compared with each other Result:Those results are as follows. 1. The highest value of fracture strength of porcelain-fused-to-titanium crowns was in the order of group with gold coating, group with TiN coating, group with $Al_2O_3$ sandblasting. No statistically significant difference was found among the three (P>.05). 2. The porcelain-fused-to-gold crowns showed the highest value in bonding strength. The bonding strength of crowns porcelain-fused-to-titanium crowns of rest groups showed bonding strength reaching only 85%-94% of that of PFG, though simple comparision seemed unacceptable due to the difference in materials used. 3. The fracturing patterns between metal and porcelain showed mixed type of failure behavior including cohesive failure and adhesive failure as a similar patterns by examination with the naked eye and SEM. But porcelain-fused-to-gold crowns showed high incidence of adhesive failure and porcelain-fused-to-titanium crowns showed high incidence of cohesive failure. Conclusion: Above results proved that when fabricating porcelain-fused-to-titanium crowns, treating casting titanium surface with gold or TiN was able to enhance the bonding strength between titanium and porcelain. Mean value of masticatory force was found to showed clinically acceptable values in porcelain bonding strength in all three groups. However, more experimental studies and evaluations should be done in order to get better porcelain bonding strength and various surface coating methods that can be applied on titanium surface with ease.

A Study of Solar Cell Module using Conductive Film Bonding (Conductive Film를 적용한 태양전지 모듈에 관한 연구)

  • Park, Jung-Cheul;Yang, Yeon-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.250-254
    • /
    • 2016
  • In this paper, solar-cell modules were fabricated by low-temperature bonding method of construction using CF. CF adhesive strength of cells at 180 degree using 3bus bar structure was measured average 2.4N. As the bonding temperature got higher, Voc and Iscwas increased. And at $185^{\circ}C$, Rseries was measured 0.013[${\Omega}$] which is the highest point. At $185^{\circ}C$, 2N and 6sec in bonding time, $P_{max}$ was measured 3.954[W], fillfactor was measured 67.36[%] and efficiency was measured13.178[%] the highest point.

CLINICAL CONSIDERATION OF INDIRECT BONDING TECHNIQUE (INDIRECT BONDING TECHNIQUE에 대한 고찰)

  • Lee, Kyung Hwan;Kim, Sang Cheol
    • The korean journal of orthodontics
    • /
    • v.19 no.2
    • /
    • pp.155-163
    • /
    • 1989
  • Indirect bonding is done by placing the brackets on a model in the laboratory and using a template or tray to transfer the laboratory positioning to the teeth. The advantages of this technique are 1. decreased chair time 2. less patient discomfort 3. accuracy of a attachment placement 4. good adaptation of attachment to tooth contour 5. occlusal relationship of brackets and opposing teeth can be checked The disadvantages of the technique are 1. complex laboratory procedure 2. sometimes difficult on very short clinical crowns 3. teeth with crowns, large buccal restoration will not bond 4. may not be fitted close, if poor adaptation 5. likely to be disturbed setting Several indirect bonding techniques have proved reliable in clinical practice. However, they differ in the way the brackets are attached temporarily to the model, the type of transfer tray or other mechanism used, the adhesive or sealant employed, whether segmented or full bonding used, and the way the transfer is removed so as not to exert excessive force on a still maturing bond.

  • PDF

Effect of Surface Treatment on Adhesive Bonding Strengh of Composite Material for Cryogenic Application (극저온용 복합재료의 접착부 강도에 미치는 표면처리 효과에 대한 연구)

  • Ahn, Myoung-Ho;So, Yong-Shin;Park, Dong-Hwan
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.28-28
    • /
    • 2010
  • The secondary barrier of cargo containment for membrane LNG tank is composed of composite materials such as rigid triplex (rigid secondary barrier, RSB) and flexible triplex (flexible secondary barrier, FSB). RSB and FSB are adhered to each other using an epoxy adherent and the quality of the secondary barrier depends on the bonding strength between them. The bonding strength between RSB and FSB is greatly influenced by the surface condition of RSB prior to joining. In this study, the effect of surface condition prior to joining on the joint strength and the fracture mode occurred between RSB and FSB have been examined in order to establish a proper surface treatment method for improving the bonding strength at the temperature of $-170^{\circ}C$.

  • PDF

An Experimental study on the bonding shear performance evaluation of UHPC accordance with adhesion surface treatment (콜드조인트 계면 처리방법에 따른 초고성능 콘크리트의 전단접착성능에 관한 실험적 연구)

  • Kim, Min-Seong;Lee, Seung-Yup;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.86-87
    • /
    • 2015
  • An active study on UHPC, which has been recently used in high-rise building and bridges, is in progress. However, research on bonding shear strength of UHPC is required to be studied due to the lack of information. In this study, experimental research progress for bonding shear strength (shear strength of adhesive surface) evaluation of UHPC (Ultra High Performance Concrete) is proceeded. First, specimens that surface treatment methods of concrete bonded section and retardation time of placement are considered are produced. Second, Direct Shear test is applied on concrete bonded section of UHPC. As a result of this study, the highest bonding shear strength specimen in which compared to the non-retardation time specimen is compaction turbulence treatment. From later study, it is judged that strength of UHPC in accordance with direction of steel fiber when steel fiber of UHPC is mixed.

  • PDF

Development of Ultra-Clean Aligning/Mounting Process of FED Spacers using Electrostatic Bonding (정전 열 접합을 이용한 FED 스페이서의 초청정 정렬/탑재 공정 개발)

  • Ju, Byeong-Kwon;Kang, Moon-Sik;Lee, Yun-Hi
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.11
    • /
    • pp.635-639
    • /
    • 2000
  • In this paper, a new idea about ultra-clean aligning and mounting method of FED spacers was introduced. The glass-to -glass electrostatic bonding process was employed in order to bond the micro-structures of spacers to black matrix area formed on an FED anode substrate. It is possible to get adhesive-free bonding interface and well-aligned spacer array on an FED anode substrate with a ${\pm}5{\mu}m$ accuracy. Finally, I inch-sized FED panel was demonstrated to make sure of its applicability to FED panel fabrication.

  • PDF

INFLUENCE OF LIGHT IRRADIATION OVER SELF-PRIMING ADHESIVE ON DENTIN BONDING (상아질접착제에 대한 광조사가 접착에 미치는 영향)

  • 류현욱;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.409-417
    • /
    • 2001
  • The purpose of this study was to investigate the influence of light irradiation over self-priming adhesive on dentin bonding. After acid etching the exposed dentin, a self-priming adhesive (Prime&Bond$^{\circledR}$NT dental adhesive system Dentsply DeTrey, GmbH, Konstanz, Germany) was applied and light irradiation was done for 20 sec with regular intensity (600 mW/$\textrm{cm}^2$) in group I and for 3 sec with ultra-high intensity (1930 mW/$\textrm{cm}^2$) in group III. No light irradiation was done over self-priming adhesive in groups II and IV. Composite resin was added on the self-priming adhesive and irradiated for 40 sec with regular intensity (600 mW/$\textrm{cm}^2$) in groups I and II and for 3 sec with ultra-high intensity (1930 mW/$\textrm{cm}^2$) in groups III and IV. To see the effect of light curing time on dentin bonding, another 3 group specimens were prepared. Without light-irradiation over self-priming adhesive, added composite resin was irradiated for 3, 6, or 12 sec with ultra-high intensity light. After bonded specimens were stored in 37$^{\circ}C$ distilled water for 24 hours, shear bond strength were measured using a universal testing machine (4202, Instron, Instron Co., U.S.A.) and fractured surfaces were examined under a stereomicroscope (SZ-PT Olympus, Japan). Statistical analysis were done with one-way, two-way ANOVA and chi-square test. The results were as follows : 1. The shear bond strengths from the groups irradiated over self-priming adhesive were significantly higher than those from the groups without irradiation (p<0.05). 2. There was no significant shear bond strength difference between regular intensity light irradiation groups and ultra-high intensity ones (p>0.05). 3. There was no significant shear bond strength difference among various irradiation time groups with ultra-high intensity ones (p>0.05). 4. In stereomicroscopic examination of fractured surfaces, adhesive-cohesive mixed failure mode was mostly seen in all groups, and there was no significant difference in failure mode among groups (p>0.05).

  • PDF