• Title/Summary/Keyword: Adhesive tape

Search Result 107, Processing Time 0.026 seconds

Effects of Hand Acupuncture Therapy on Sleep Quality in Sleep Disrupted Adults - Verification by Polysomnography and Cerebral Blood Flow Test - (수지요법이 수면장애를 가진 성인의 수면의 질에 미치는 효과 - 수면다원검사 및 뇌혈류 검사를 통한 검증 -)

  • Hwang, Eun-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.37 no.7
    • /
    • pp.1108-1118
    • /
    • 2007
  • Purpose: The purpose of this study was to identify the effects of hand acupuncture therapy on sleep quality by means of a sleep questionnaire, polysomnography and a cerebral blood flow test in $30{\sim}59$ year old adults. Methods: The study was a sham controlled design. Twenty-two adults were assigned to the pellet stimulating group (11) or sham group (11). The pellet stimulating group received hand acupuncture therapy using New Seoam Press Pellets number 1 for 4 weeks. On the other hand, the sham group used the same Adhesive tape in terms of shape, size and quality as New Seoam Press Pellets number 1 for 4 weeks. A Transcranial Doppler Ultrasonography and Carotid Duplex Ultrasonography examination were used for evaluating cerebral blood flow. Data was analyzed using the SPSS 12.0 version program with $X^2-test$, Fisher's exact test and Mann Whitney U-test. Results: In the pellet stimulating group, subjective sleep quality significantly improved more than that of the sham group. Among the sleep indices of the polysomnography, total sleep time and sleep latency of the sham group significantly improved. The cerebral blood flow test didn't show any differences. Conclusion: These results suggest that hand acupuncture therapy is effective for subjective sleep improvement only, not polysomnographical sleep indices and cerebral blood flow.

Fabrication and Characteristic Analysis of a Flexible Tactile Sensor Using PVDF (PVDF를 이용한 유연 촉각센서의 제작 및 특성해석)

  • 윤명종;권대규;유기호;이성철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.390-390
    • /
    • 2000
  • This research is the development of a skin-type tactile sensor for service robot using PVDF film for the detection of the contact state. The Prototype of the tactile sensor which has 8$\times$8 taxels was fabricated using PVDF film In the fabrication procedure of the sensor, the electrode patterns and common electrode of the thin conductive tape were attached to the both side of the 28 micro meter thickness PVDF film using conductive adhesive. The sensor was covered with polyester film for insulation and attached to the rubber base for making stable structure. The signals of a contact pressure to the tactile sensor were sensed and processed in the DSP system in which the signals were digitized and filtered. Finally, the signals were integrated for taking the force profile. The processed signals of the output of the sensor were visualized in PC, the shape and force distribution of the contact object were obtained. The reasonable performance for the detection of contact state was verified through the experiment.

  • PDF

An Analysis of Students' Reports on an Assigned Problem for 'Fractal Diffraction' in the first Korean Youth Physics Tournament (제1회 한국물리탐구토론대회에 출제된 "Fractal Diffraction" 문제 풀이에 대한 분석)

  • Yuk, Keun-Cheol;Lee, Hee-Bok;Kim, Myung-Hwan
    • Journal of Gifted/Talented Education
    • /
    • v.12 no.4
    • /
    • pp.120-130
    • /
    • 2002
  • We have analyzed students' reports on a problem for 'adhesive tape' and 'fractal diffraction' among ten assigned problems in the first Korean youth physics tournament (KYPT). There were three high school team' s reports and one middle school team' s report on this problem. However, many students failed to solve the 'fractal diffraction' problem correctly due to having no idea of fractal. This problem was found to be most difficult one for the participated students among ten assigned problems given in the first KYPT.

Fixation of Epidural Catheters using blood Set -Report of 120 cases- (지속성 경막외카테터의 거치 방법 -수혈선을 이용하여-)

  • Chang, Bo-Yul;Kim, Soon-Jae;Kim, Hyun-Soo;Kim, Kwang-Min;Choi, Byung-Jo
    • The Korean Journal of Pain
    • /
    • v.1 no.2
    • /
    • pp.199-202
    • /
    • 1988
  • Secure fixation is essential for continous epidural catheterization on a long-term-basis. Adhesive tape or surgical knots were commonly used for those patients, but the surgical knot method has a tendency to cause strangulation of catheter. Another invasive technique, subcutaneous tissue tunnelling is more safe than other methods but requires sophisticated technique and time. We employed a simple device using a blood transfusion set for patients who have epidural catheters placed safely un their backs. In 120 patients treated for postoperative and chronic pain by means of this technique, the results were as follows: 1) Five of 120 patients (4.2%) developed backache and pruritus, but there were no instances of respiratory depression, local infection and headache. 2) Nine of 120 patients (7.5%) failed booster-injections, but two cases were due to be non-technical errors. 3) The duration of fixation was 1~3 days in most cases (85%), the longest being for 21 days.

  • PDF

Fabrication of thin Film Transistor on Plastic Substrate for Application to Flexible Display (Flexible 디스플레이로의 응용을 위한 플라스틱 기판 위의 박막트랜지스터의 제조)

  • 배성찬;오순택;최시영
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.7
    • /
    • pp.481-485
    • /
    • 2003
  • Amorphous silicon (a-Si:H) based TFT process has been studied at the maximum temperature of 15$0^{\circ}C$ with 25${\mu}{\textrm}{m}$ thick flexible and adhesive tape type polyimide foil substrate, which has benefit on handling a rugged, flexible plastic substrate trough sticking simply it to glass. This paper summarize the process procedure of the TFT on the plastic substrate and shows its electrical characteristics in comparison with glass substrate using primarily the ON/OFF current ratio and the field effect mobility as the quality criterion. The a-SiN:H coating layer played an important role in decreasing surface roughness of plastic substrate, so leakage current of TFT was decreased and mobility was increased. The results show that high quality a-Si:H TFTs can be fabricated on the plastic substrates through coating a rough plastic surface with a-SiN:H.

Development of method to remove weld scallop and ceramic backing material of wedge type and its application

  • Kang, Sung-Koo;Yang, Jong-Soo;Kim, Ho-Kyung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.7 no.2
    • /
    • pp.315-323
    • /
    • 2015
  • The weld scallop has been used for joining T-bars. There are a lot of weld scallops in shipbuilding. It is difficult to perform scallop welding due to the inconvenient welding position. This results in many problems such as porosity, slag inclusion, etc. In this study, a new method is devised to remove weld scallops by incorporating a Ceramic Backing Material (CBM). The weld scallop is removed by an elongation of the v groove. In order to insert a CBM into the groove without a weld scallop, a wedge-shaped CBM is developed. The top side of the developed CBM is similar to the shape of a general back bead. The bottom surface has a saw-toothed shape for cutting at a suitable length. This can be attached to the root side of a face plate using adhesive tape, just like a general CBM. Welding experiments in normal and abnormal conditions are carried out and the possibility of burn-through is examined. This CBM's applicability to shipbuilding is verified.

The Development of Design Structure for Environmental Friendly Non-Staple Boxes and Cases Made by the Carton and Corrugated Paperboard (카톤지와 골판지를 이용한 친환경 논스테이플 박스와 케이스 디자인 구조개발)

  • Cho, Yong-Min;Um, Gi-Jeung;Kim, Jin-Moo
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.39 no.1 s.119
    • /
    • pp.69-77
    • /
    • 2007
  • Carton and corrugated paperboard have excellent convertibility characteristics that could be easily slitted, folded, and inserted to become a certain shape of box or case. This excellent processing characteristics of carton and corrugated paperboard as well as their recyclability will continue to make them possess high portion in packaging markets. However, staple, tape, or adhesive have been used to seal a paperboard packaging box or case. Staples among them have been frequently used in many cases because of their convenience. Staples could enter the inside the box and give wounds to the goods in the box or case. Furthermore additional handling and waste treatment costs in the making and recycling processes would be necessary when staple is used to seal box or case. This study has been carried out to develop non-staple paperboard packaging box & case designs that can be used to make non-staple boxes & cases. It is believed that the non-staple folding paperboard boxes & cases could be more environmental-friendly, beautiful, and economic than staple boxes & cases.

Development of Debris-free Process using Erasable Ink for Polymer Ablation (폴리머의 어블레이션 시 소거성 잉크를 이용한 잔유물 제거공정 개발)

  • Shin, D.S.;Lee, J.H.;Suh, J.;Kim, T.H.
    • Laser Solutions
    • /
    • v.8 no.2
    • /
    • pp.21-32
    • /
    • 2005
  • The excimer laser ablation of a polymer occurs by the excitation of chemical bonds to energy levels that are above the dissociation energy. In this process, however, fragmented debris is finally ejected explosively by the scission of bonds and accumulates on the material surface. In the present work, a process for eliminating surface debris contamination generated by the laser ablation of a polymer is developed. The proposed approach for removing surface debris utilizes an erasable ink pasted on a polymide. The ink pasted polyimide is ablated by KrF excimer laser. The surface debris ejected from the polyimide is then combined with the ink layer on the polymer. Finally, both the surface debris and the ink layer are removed using adhesive tape or alcohol solvent. The results suggest that the erasable ink method is a simple, low cost, and extremely effective debris eliminating process.

  • PDF

Characteristics Influencing the Occurrence of Respiratory Medical Device-related Pressure Ulcers in the Pediatric Intensive Care Unit (소아중환자실 환아의 호흡기계 의료장치 관련 욕창 발생 관련 특성)

  • Kim, Hae-kyung;Kim, Younghae;Son, Hyun-Mi
    • Child Health Nursing Research
    • /
    • v.25 no.2
    • /
    • pp.133-142
    • /
    • 2019
  • Purpose: This prospective study was conducted to determine the incidence and related characteristics of respiratory medical device-related pressure ulcers (MDRPU) in children admitted to a pediatric intensive care unit (PICU). Methods: The participants were 184 children who were admitted to the PICU of P University Hospital from April 2016 to January 2017. Data were collected on the occurrence of respiratory MDRPU and characteristics regarding the application of respiratory medical devices. Results: Respiratory MDRPU occurred in 11.9% of participants (58.3%: stage I ulcers, 37.5%: mucosal ulcers). The devices associated with respiratory MDRPU were endotracheal tubes (54.2%), high-flow nasal cannulas (37.5%), and oximetry probes (8.3%). Respiratory MDRPU associated with an endotracheal tube were significant differences according to the site and strength of fixation, the use of a bite block and adhesive tape, skin dryness, and edema. In high-flow nasal cannulas, significant differences were found according to the site of fixation, immobility after fixation, and skin dryness. Conclusion: The occurrence of respiratory MDRPU is significantly affected by the method and strength of fixation, as well as skin dryness and edema. Therefore, appropriate consideration of these factors in nursing care can help prevent respiratory MDRPU.

Nanostructured energy harvesting devices and their applications for IoT sensor networks (나노구조체 에너지 하베스팅 소자와 IoT 센서 네트워크의 융합 연구)

  • Yoon, Chongsei;Jeon, Buil;Yoon, Giwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.5
    • /
    • pp.719-730
    • /
    • 2021
  • We have demonstrated a sandwich-type ZnO-based piezoelectric energy harvesting nanogenerator, namely ZCZ-NG device, composed of symmetrically stacked layers of ZnO/carbon tape/ZnO structure. Especially, we have adopted a conductive double-sided adhesive carbon tape in an effort to fabricate a high-quality ZCZ-NG device, leading to its superior output performance in terms of the peak-to-peak output voltage. Effects of the device size, ZnO layer thickness, and bending strain rate on the device performance have been investigated by measuring the output voltage. Moreover, to evaluate the effectiveness of the fabricated ZCZ-NG devices, we have experimentally implemented a sensor network testbed which can utilize the output voltages of ZCZ-NG devices. This sensor network testbed consists of several components such as Arduino-based transmitter and receiver nodes, wirelessly transmitting the sensed information of each node. We hope that this research combining the ZnO-based energy harvesting devices and IoT sensor networks will contribute to the development of more advanced energy harvester-driven IoT sensor networks in the future.