• 제목/요약/키워드: Adhesion and Removal

검색결과 133건 처리시간 0.03초

Reciprocating Wear Test of AISI 52100 Bearing Steel in h-BN-based Aqueous Lubricants

  • Gowtham Balasubramaniam;Dae-Hyun Cho
    • Tribology and Lubricants
    • /
    • 제39권6호
    • /
    • pp.228-234
    • /
    • 2023
  • In this study, reciprocating wear tests are performed on AISI 52100 bearing steel to investigate its tribological behavior in a hexagonal boron nitride (h-BN) water solution. The h-BN-based aqueous lubricant is prepared using an atoxic procedure called ultrasonic sonication in pure water. Ball-on-flat reciprocating sliding experiments are conducted, where the ball is slewed on a fixed flat at 50-㎛ displacement. The lubricating behavior of h-BN is compared with that of deionized (DI) water. Results show that the friction coefficient is higher in h-BN testing than that in DI tests, but the results are equalized as the friction coefficient reaches a stable level. Scanning electron microscopic images reveal significant material loss in the center and mild abrasion on the edge of the wear scar in h-BN tests. However, these effects are minor in DI water situations. The results of energy-dispersive X-ray spectroscopy show that considerable oxidation occurs in the central zone of the wear scar in h-BN cases with strong adhesion and material removal. These findings reveal the importance of determining ideal circumstances that can tolerate material friction and wear.

Cu-Cu 열압착 웨이퍼 접합부의 계면접합강도에 미치는 $N_2+H_2$ 분위기 열처리의 영향 (Effect of $N_2+H_2$ Forming Gas Annealing on the Interfacial Bonding Strength of Cu-Cu thermo-compression Bonded Interfaces)

  • 장은정;김재원;;;현승민;이학주;박영배
    • 마이크로전자및패키징학회지
    • /
    • 제16권3호
    • /
    • pp.31-37
    • /
    • 2009
  • 3차원 소자 집적을 위한 저온접합 공정 개발을 위해 Cu-Cu 열 압착 접합을 $300^{\circ}C$에서 30분간 실시하고 $N_2+H_2$, $N_2$분위기에서 전 후속 열처리 효과에 따른 정량적인 계면접착에너지를 4점굽힘시험법을 통해 평가하였다. 전 열처리는 100, $200^{\circ}C$$N_2+H_2$ 가스 분위기에서 각각 15분간 처리하였고, 계면접착에너지는 2.58, 2.41, 2.79 $J/m^2$로 전 열처리 전 후에 따른 변화가 없었다. 하지만 250, $300^{\circ}C$$N_2$ 분위기에서 1시간씩 후속 열처리 결과 2.79, 8.87, 12.17 $J/m^2$으로 Cu 접합부의 계면접착에너지가 3배 이상 향상된 결과를 얻을 수 있었다.

  • PDF

Non-Dura Based Intaspinal Clear Cell Meningioma

  • Ko, Jun-Kyeung;Choi, Byung-Kwan;Cho, Won-Ho;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권1호
    • /
    • pp.71-74
    • /
    • 2011
  • A 34-year-old female patient was presented with leg and hip pain for 6 months as well as voiding difficulty for 1 year. Magnetic resonance imaging revealed a well-demarcated mass lesion at L2-3. The mass was hypo-intense on T1- and T2-weighted images with homogeneous gadolinium enhancement. Surgery was performed with the presumptive diagnosis of intradural extramedullary meningioma. Complete tumor removal was possible due to lack of dural adhesion of the tumor. Histologic diagnosis was clear cell meningioma, a rare and newly included World Health Organization classification of meningioma usually affecting younger patients. During postoperative 2 years, the patient has shown no evidence of recurrence. We report a rare case of cauda equina clear cell meningioma without any dural attachment.

Blood clot stabilization after different mechanical and chemical root treatments: a morphological evaluation using scanning electron microscopy

  • Stefanini, Martina;Ceraolo, Edoardo;Mazzitelli, Claudia;Maravic, Tatjana;Sangiorgi, Matteo;Zucchelli, Giovanni;Breschi, Lorenzo;Mazzoni, Annalisa
    • Journal of Periodontal and Implant Science
    • /
    • 제52권1호
    • /
    • pp.54-64
    • /
    • 2022
  • Purpose: This in vitro study was conducted to evaluate the effects of different debridement techniques and conditioning procedures on root surface morphology and blood clot stabilization. Methods: Two debridement techniques (curette [CU] vs. high-speed ultrasound [US]) and 2 conditioning procedures (ethylenediaminetetraacetic acid [EDTA] and phosphoric acid [PA]) were used for the study. Seven experimental groups were tested on root surfaces: 1) no treatment (C); 2) CU; 3) US; 4) CU+EDTA; 5) US+EDTA; 6) CU+PA; and 7) US+PA. Three specimens per group were observed under scanning electron microscopy (SEM) for surface characterization. Additional root slices received a blood drop, and clot formation was graded according to the blood element adhesion index by a single operator. Data were statistically analyzed, using a threshold of P<0.05 for statistical significance. Results: The C group displayed the most irregular surface among the tested groups with the complete absence of blood traces. The highest frequency of blood component adhesion was shown in the CU+EDTA group (P<0.05), while no differences were detected between the CU, US+EDTA, and CU+PA groups (P<0.05), which performed better than the US and US+PA groups (P<0.05). Conclusions: In this SEM analysis, EDTA and conventional manual scaling were the most efficient procedures for enhancing smear layer removal, collagen fiber exposure, and clot stabilization on the root surface. This technique is imperative in periodontal healing and regenerative procedures.

활성탄소섬유의 비표면적에 따른 유해가스 흡착 및 전기화학적 감응 특성 (Effect of Specific Surface Area of Activated Carbon Fiber on Harmful Gas Adsorption and Electrochemical Responses)

  • 강진균;정용식;배병철;류지현
    • 접착 및 계면
    • /
    • 제21권2호
    • /
    • pp.51-57
    • /
    • 2020
  • 최근 산업활동을 통해 배출되는 유해 오염물질 제거에 대한 관심이 증가하고 있다. 본 연구에서는 수증기 활성화 법을 이용하여 활성탄소섬유를 제조하고, 이의 유해가스 흡착 및 전기화학적 감응 특성을 분석하였다. 활성탄소섬유의 균일한 기공 구조, 활성 반응 면적 및 반응 위치를 조절하기 위하여, 활성화 온도(750-850 ℃) 및 활성화 시간(30-240 min)을 조절하였고, 다양한 활성화 조건을 통해 제조된 활성탄소섬유의 SO2와 NO 가스 흡착 및 가스 센서를 통한 감응 특성을 분석하였다. 특히, 850 ℃에서 45 min동안 수증기 활성화 반응을 통해 제조된 활성탄소섬유가 가장 높은 비표면적(1,041.9 ㎡/g)과 기공 특성(0.42 ㎤/g)을 보였으며, 우수한 SO2 (1.061 mg/g) 및 NO (1.210 mg/g) 가스 흡착 특성을 보였다.

치주조직재생유도술용 비흡수성 차폐막 (e-PTFE membrane)에의 세균부착 및 침투 (Bacterial Adhesion And Penetration To e-PTFE Membrane Used For The Guided Tissue Regeneration)

  • 정현주;이성미;이호재;김옥수
    • Journal of Periodontal and Implant Science
    • /
    • 제26권1호
    • /
    • pp.103-116
    • /
    • 1996
  • This study was performed to observe the bacterial adhesion and penetration to e-PTFE membrane following guided tissue regeneration(GTR) procedure and to evaluate the association of the membrane exposure and bacterial contamination with the clinical outcome. For the study, ten infrabony defects in 9 patient were treated by mucoperiosteal flap operation including placement of the e-PTFE membrane. The treated teeth were monitored weekly for the membrane exposure, gingival recession and gingival inflammation. The membranes were retrieved after 4 to 6 weeks, examined by SEM for bacterial contamination and adherent connective tisue elements, and observed under LM for the bacterial penetration into membrane. Three months postsurgery, the defect sites were clinically reexamined for the changes in attachment level and probing depth. Comparison of the ultrastuctural findings and clinical outcome revealed that extent of membrane exposure and bacterial contamination of the membrane was inversely associated with clinical attachment gain. From this finding, the extent of membrane exposure and the bacterial contamination on the apical portion of the e-PTFE membrane at the time of removal seemed to be a critical determinant on the clinical outcome of GTR and the membrane exposure needs to be controlled for optimal results.

  • PDF

핫멜트 Web spray법을 이용한 고기능성 복합 화학필터의 제조 및 흡착특성 (Preparation of High Performance Hybrid Chemical Filter using Hot Melt Adhesive by Web Spray and Their Adsorption Properties)

  • 최용재;신경섭;황택성
    • 접착 및 계면
    • /
    • 제10권3호
    • /
    • pp.141-147
    • /
    • 2009
  • 본 연구는 web spray 분사방식으로 핫멜트 접착제를 이용하여 high performance hybrid chemical filter (HPHCF)를 제조하였다. HPHCF은 이온교환 수지와 PP 부직포를 사용하였고, HPHCF의 제조 시 최적 조건은 핫멜트의 온도는 $170^{\circ}C$에서 분사압력은 50 psi일 때 최적의 제조 조건을 나타내었다. 제조된 HPHCF의 특성 및 암모니아 흡착성능을 측정하였다. HPHCF 이온교환용량은 수지 부착량이 증가함에 따라 증가하였으며 단일 수지와 이온교환섬유의 이온교환용량보다 크게 나타났다. 또한 암모니아의 제거율은 HPHCF의 충진 밀도가 증가할수록 증가하였으며 흡착 파과시간은 13 min으로 단일 섬유나 수지에 비해 길게 나타났고 최대 암모니아 흡착량은 98%이었다. 또한 암모니아 흡착 파과시간은 유량 및 농도가 증가함에 따라 빠르게 진행되었다.

  • PDF

A simplified etching technique to improve the adhesion of fiber post

  • Majeti, Chandrakanth;Veeramachaneni, Chandrasekhar;Morisetty, Pradeep Kumar;Rao, Saggurti Anitha;Tummala, Muralidhar
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.295-301
    • /
    • 2014
  • PURPOSE. Numerous methods were used to etch the fiber posts to improve its bonding to root canal dentin. Our aim was to evaluate the efficacy of 37% phosphoric acid in etching fiber posts in comparison with 24% hydrogen peroxide. MATERIALS AND METHODS. Ninety human maxillary central incisors were taken and post space preparation was done. Ninety fiber posts were taken and divided into three groups (n=30) based on the surface treatment they received ($H_3PO_4$, $H_2O_2$, distilled water) and each group was further divided (n=10) based on the time period of application (15 seconds, 30 seconds, 60 seconds). All the posts were luted into canals using Rely X UniCem-2. Each tooth was then sectioned into six slices and subjected to push out test. Data obtained was subjected to statistical analysis at P<.05. The surface topography was evaluated using scanning electron microscopy. RESULTS. Highest bond strength values were noted in 15 seconds etched phosphoric acid group and 60 seconds etched hydrogen peroxide group with no significant difference between two groups. Surface topography revealed complete epoxy layer removal with no damage to its structural integrity in those groups. CONCLUSION. $H_3PO_4$ etching for a period of 15 seconds is an effective alternative in improving the adhesion of fiber post to root dentin.

폴리스티렌 구형입자를 주형으로 이용한 할로우 메조포러스 질화탄소 구형입자의 합성 (Synthesis of Hollow Mesoporous Carbon Nitride Spheres Using Polystyrene Spheres as Template)

  • 박성수;하창식
    • 접착 및 계면
    • /
    • 제15권2호
    • /
    • pp.63-68
    • /
    • 2014
  • 주형으로 구형의 폴리스티렌을 사용하고 질소와 탄소원으로 시안아미드를 사용하여 열처리 과정을 거친 후 구형의 할로우 메조포러스 질화탄소 물질을 합성하였다. 이때 할로우 메조포러스 질화탄소 물질을 합성하는 과정에서 실리카와 같은 무기물 주형을 사용하지 않기 때문에 이차적인 실리카 제거 공정이 필요 없고 용매를 전혀 사용하지 않는다. 구형의 폴리스티렌 입자는 약 170 nm 크기였고 그리고 할로우 메조포러스 질화탄소 구형입자의 할로우 직경은 약 82 nm, 벽 두께는 약 13 nm이었다. 또한 할로우 메조포러스 질화탄소 물질의 표면적, 나노세공 크기, 세공부피는 각각 $188m^2g^{-1}$, 3.8 nm, $0.35cm^3g^{-1}$이었다. 한편, 할로우 벽은 흑연구조와 유사한 박막층의 쌓임 구조를 가졌으며 이러한 할로우 메조포러스 질화탄소 물질은 연료전지, 촉매, 광촉매, 전자방출 소자 등과 같은 분야에 매우 높은 응용 가능성을 가질 것으로 기대된다.

전기화학 계면반응에 기초한 DSA 전극을 사용한 고성능 폐수처리 시스템 (The wastewater treatment system with high performance based on electrochemical interface reaction using dimensionally stable anode with simple manufacturing)

  • 나영수;이만성;김경호
    • 접착 및 계면
    • /
    • 제19권3호
    • /
    • pp.101-105
    • /
    • 2018
  • 도시의 산업화와 인구의 빠른 증가로 인해, 지구상에서 여전히 7억 8천만명이 물자원 사용에 어려움을 격고 있으며, 이에 따라 깨끗하고 저렴한 물자원 확보 방안에 대한 관심이 집중되고 있다. 그러나, 현존하는 폐수처리 시스템은 낮은 공정효율, 높은 운영비용, 그리고 넓은 부지 요구 등의 다양한 이슈에 직면하여 있는 실정이다. 따라서, 저렴하고 효율적인 폐수 처리 시스템의 개발이 시급히 요구된다. 이러한 노력의 일환으로 rutile type $RuO_2$를 기반으로 한 DSA전극을 이용한 전기 화학적 방법에 기초한 폐수 처리 시스템을 제안하였고, 이를 성공적으로 시연하였다. 우리의 폐수 처리 시스템은 생활폐수의 경우, 생화학적 산소 요구량 (BOD), 화학적 산소 요구량 (COD) 및 총 유기탄소 (TOC) 제거 효율이 52.0 %, 77.8 % 및 65.6 % 로 우수한 특성을 보였다. 또한 축산 폐수의 경우, BOD, COD, 총 질소 (TN), 총 인 (TP)의 제거 효율이 각각 92.9 %, 75.6 %, 35.1 %, 100 %로 획기적인 감축 효과를 거두었습니다. 이 장치의 탁월한 제거 효율과 작은 크기를 고려할 때, rutile $RuO_2$로 코팅된 DSA를 사용한 전기화학적 폐수 처리는 생활 및 축산 폐수의 처리를 위한 유망한 방안이 될 수 있음을 제안하고자 합니다.