• Title/Summary/Keyword: Active-Bypass

Search Result 29, Processing Time 0.028 seconds

A Highly Efficient Dual-Mode 3G/4G Linear CMOS Stacked-FET Power Amplifier Using Active-Bypass

  • Kim, Unha;Kim, Yong-Gwan;Woo, Jung-Lin;Park, Sunghwan;Kwon, Youngwoo
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.393-398
    • /
    • 2014
  • A highly efficient dual-mode linear CMOS stacked-FET power amplifier (PA) is implemented for 3G UMTS and 4G LTE handset applications. High efficiency is achieved at a backed-off output power ($P_{out}$) below 12 dBm by employing an active-bypass amplifier, which consumes very low quiescent current and has high load-impedance. The output paths between high- and low-power modes of the PA are effectively isolated by using a bypass switch, thus no RF performance degradation occurs at high-power mode operation. The fabricated 900 MHz CMOS PA using a silicon-on-insulator (SOI) CMOS process operates with an idle current of 5.5 mA and shows power-added efficiency (PAE) of 20.5%/43.5% at $P_{out}$ = 12.4 / 28.2 dBm while maintaining an adjacent channel leakage ratio (ACLR) better than -39 dBc, using the 3GPP uplink W-CDMA signal. The PA also exhibits PAE of 35.1% and $ACLR_{E-UTRA}$ of -33 dBc at $P_{out}$ = 26.5 dBm, using the 20 MHz bandwidth 16-QAM LTE signal.

Comparison Study on Power Output Characteristics of Power Management Methods for a Hybrid-electric UAV with Solar Cell/Fuel Cell/Battery

  • Lee, Bohwa;Kwon, Sejin
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.4
    • /
    • pp.631-640
    • /
    • 2016
  • A dual-mode power management for a hybrid-electric UAV with a cruise power of 200W is proposed and empirically verified. The subject vehicle is a low-speed long-endurance UAV powered by a solar cell, a fuel cell, and a battery pack, which operate in the same voltage bounds. These power sources of different operational characteristics can be managed in two different methods: passive management and active management. This study proposes a new power management system named PMS2, which employs a bypass circuit to control the individual power sources. The PMS2 normally operates in active mode, and the bypass circuit converts the system into passive mode when necessary. The output characteristics of the hybrid system with the PMS2 are investigated under simulated failures in the power sources and the conversion of the power management methods. The investigation also provides quantitative comparisons of efficiencies of the system under the two distinct power management modes. In the case of the solar cell, the efficiency difference between the active and the passive management is shown to be 0.34% when the SOC of the battery is between 25-65%. However, if the SOC is out of this given range, i.e. when the SOC is at 90%, using active management displays an improved efficiency of 6.9%. In the case of the fuel cell, the efficiency of 55% is shown for both active and passive managements, indicating negligible differences.

Low-Power Cool Bypass Switch for Hot Spot Prevention in Photovoltaic Panels

  • Pennisi, Salvatore;Pulvirenti, Francesco;Scala, Amedeo La
    • ETRI Journal
    • /
    • v.33 no.6
    • /
    • pp.880-886
    • /
    • 2011
  • With the introduction of high-current 8-inch solar cells, conventional Schottky bypass diodes, usually adopted in photovoltaic (PV) panels to prevent the hot spot phenomenon, are becoming ineffective as they cause relatively high voltage drops with associated undue power consumption. In this paper, we present the architecture of an active circuit that reduces the aforementioned power dissipation by profitably replacing the bypass diode through a power MOS switch with its embedded driving circuitry. Experimental prototypes were fabricated and tested, showing that the proposed solution allows a reduction of the power dissipation by more than 70% compared to conventional Schottky diodes. The whole circuit does not require a dedicated DC power and is fully compatible with standard CMOS technologies. This enables its integration, even directly on the panel, thereby opening new scenarios for next generation PV systems.

Prediction of Bypass Flow Rate through Gas Diffusion Layer in PEMFC with Serpentine Flow Channels (사행 유로를 갖는 고분자 전해질 연료전지의 기체확산층 내부에서의 우회 유동 예측)

  • Jeon, Se-Gye;Kim, Kuoung-Youn
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.4
    • /
    • pp.293-299
    • /
    • 2012
  • The serpentine flow channel is widely used in polymer electrolyte membrane fuel cells (PEMFCs) to prevent flooding phenomena because it effectively removes liquid water in the flow channel. The pressure drop between inlet and outlet increases as compared with straight channels due to minor losses associated with the corners of the turning configurations. This results in a strong pressure gradient between adjacent channels in specific regions, where some amount of reactant gas can be delivered to catalyst layers by convection through a gas diffusion layer (GDL). The enhancement of the convective flow in the GDL, so-called bypass flow, affects fuel cell performance since the bypass flow influences the reactant transport and thus its concentration over the active area. In the present paper, for the bipolar plate design, a simple analytic model has been proposed to predict the bypass flow in the serpentine type flow channels and validated with three-dimensional numerical simulation results.

Single-Phase Transformerless Inverter using Passive Bypass Filter (수동 바이패스 필터를 이용한 단상 무변압기형 인버터)

  • Yang, Min-Kwon;Heo, Jun;Lee, Myung-Chul;Kim, Yu-Jin;Choi, Woo-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.2
    • /
    • pp.129-138
    • /
    • 2018
  • Previous single-phase transformerless inverters used active bypass switching circuits that need auxiliary power switches to minimize ground leakage current. However, switching and gate driving losses are increased due to the use of additional power switches. To cope with this drawback, this work proposes a transformerless inverter using a passive bypass filter without any auxiliary power switch. The operation and control of the proposed inverter are described. The ground leakage current characteristics are analyzed for the proposed inverter with the passive bypass filter. The experimental results of the proposed inverter for a 1.0kW prototype system are presented.

Simultaneous Off-pump Coronary Artery Bypass Surgery and Total Gastrectomy (동시에 시행한 체외순환 없이 시행하는 관상동맥우회수술과 위전절제술)

  • Park, Jeong-Ok;Ryu, Jae-Wook;Seo, Pil-Won
    • Journal of Chest Surgery
    • /
    • v.40 no.1 s.270
    • /
    • pp.56-59
    • /
    • 2007
  • A 65 year-old male had chest pain which was diagnosed as unstable angina needing urgent coronary artery bypass surgery. Physical examination demonstrated signs of severe anemia and hemoglobin level was 5.7 g/dL. Gastrofiberscopy showed a 4 cm sized fungating mass at the lesser curvature with active bleeding. The mass was adenocarcinoma by pathologic examination. Simultaneous coronary artery bypass surgery and total gastrectomy were planned due to bleeding of the mass. Off-pump coronary bypass grafting was done first, followed by total gastrectomy. The postoperative course was smooth. He was discharged from the hospital after 12 days and was on surveillance for 9 months. We report a rare case of simultaneous surgery for angina and gastric cancer.

Experimental Fetal Cardiopulmonary Bypass in the Fetal Lamb Model (태아양 모델을 이용한 실험적 태아 심폐우회술)

  • 이정렬;임홍국;김원곤;김종성;최정연;김용진
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.495-503
    • /
    • 1999
  • Background: We tested the technical feasibility of fetal cardiac bypass and collected baseline data on the fetal hemodynamics and placental functions related to the cardiopulmonary bypass in the fetal lamb model. Material and Method: Eleven fetuses at 120 to 150 days of gestation were subjected to bypass via trans-sternal approach with a 12 G pulmonary arterial cannula and 14 to 18 F venous cannula for 30 minutes. All ewes received general anesthesia with ketamine. In all the fetuses, no anesthetic agents were used except muscle relaxant. Eight served as a group in which placenta was excluded from the extracorporeal circulation by clamping the umbilical cord during the bypass(the oxygenator group) and in the remaining three, the placenta worked as the only source of oxygen supply(the placenta group). Observations were made every 10 minute during a 30-minute bypass and 30-minute post bypass period. No prostaglandin inhibitors were used both in ewes and in fetuses. Result: Weights of the fetuses ranged from 1.9 to 5.2 kg. In the oxygenator group, means of arterial pressure, PaO2, atrial pressure, heart rate, and bypass flow rate ranged 69.8 to 82.6 mmHg, 201.7 to 220.9 mmHg, 4.1 to 4.3 mmHg, 169 to 182/min, and 140.3 to 164.0 ml/kg/min, respectively during bypass, but rapid deterioration of the fetal cardiac functions and the placental gas exchange was observed after the cessation of bypass. In the placenta group, means of arterial pressure decreased from 44.7 to 14.4 mmHg and means of PaCO2 increased from 61.9 to 129.6 mmHg during bypass. Flow rate was suboptimal(74.3 to 97.0 ml/kg/min) during bypass. All hearts fibrillated immediately after the discontinuation of bypass. Conclusion: In this study, the technical feasibility of fetal cardiopulmonary bypass was confirmed in the fetal lamb model. However, further studies with modifications of the bypass including an addition of prostaglandin inhibitor, an application of the total spinal anesthesia on the fetus, a creation of more concise bypass circuit, and a use of active pump are mandatory to improve the outcome.

  • PDF

Regeneration of Burner Type Diesel Particulate Trap System Through Active Exhaust Gas Feeding (배기 가스 유량 제어를 이용한 버너방식 디젤 입자상물질 제거 장치의 재생)

  • 김재업;박동선;이만복;김응서
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.1
    • /
    • pp.1-13
    • /
    • 1997
  • The key point that guarantees the durability of the ceramic monolith filter is to lower peak temperature and temperature gradient inside filter during regeneration. The control of the exhaust gas flow rate into the filter, by the bypass technique of the exhaust gas, enables the gas temperature in filter to be constant for regeneration. A couple of methods, which are the ON/OFF and PID control of the bypass valve, were used for feedback control of the gas temperature. These techniques showed that the ceramic filter was regenerated perfectly under the peak temperature and peak temperature gradient limitations for durability.

  • PDF

Design and Implementation of Double Down-Converter for Satellite TV (위성 TV용 이중 하향 변환기의 설계 및 제작)

  • Lee, Seung-Dae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.840-845
    • /
    • 2013
  • In this paper, the broadband frequency double down-converter based on LC filter technologies has been designed and implemented, and its performances are introduced. The Designed frequency double down-converter is consisted with a low-noise amplifier, mixer, IF amplifier, LC filter, DC-block capacitor and RF-bypass capacitor. Especially, instead of active devices of a typical converter, the suggested converter designed using passive devices to provide both low-power consumption and low-cost model. As results of the measurement, the implemented frequency double down-converter realizes the broadband performance with the bandwidth of 100MHz (13~113MHz) at the center frequency of 63MHz, and its gain is approximately 40dB.

Hydration and mechanical properties of Blended Cement added Bypass dust (By-pass Dust를 첨가한 혼합 시멘트의 수화 및 기계적 특성)

  • 성진욱;나종윤;김창은;이승헌;이봉한;김수룡;류한웅
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.33-39
    • /
    • 1999
  • This study was conducted to confirm the effect of bypass dust on the hydration and mechanical properties of the cement pastes and mortar obtained from ordinary Portland cement (OPC), OPC-slag and OPC-fly ash system. The rate of heat evolution is accelerated with the content of By-pass Dust(BD). total heat evolution increased because alkali-chlorides activated the hydration of blended cement. Compressive strength and bound water content show maximum value at 5wt% By-pass Dust(BD) on each curing time in ordinary Portland cement and slag blended cement. Ca(OH)2 content of Ordinary Portland Cement increased as the content of BD and curing time. In blended cement, the formation of Ca(OH)2 is active at early hydration stage. By pozzolanic reaction, the content of Ca(OH)2 is decreased as curing time goes by. According to the BD content stable chlorides complex of Friedel's salt (C3A·CaCl2·10H2O) is created. Due to the hydration activation effect of chlorides and alkali we observed Type II C-S-H, which developed into densest microstructure.

  • PDF