• Title/Summary/Keyword: Active vector

Search Result 434, Processing Time 0.026 seconds

Development of a New Active Phase Shifter

  • Kim, S.J.;N.H. Myung
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.1063-1066
    • /
    • 2000
  • ln this paper, a new active phase shifter is proposed using a vector sum method, and it is shown that the proposed phase shifter is more efficient than the others in size, power, number of circuits, and gain. Also a unique digital phase control method of the circuit is suggested. The proposed scheme was designed and implemented using a Wilkinson power combiner/divider, a branch line 3dB quadrature hybrid coupler and variable gain amplifiers (VGAs) using dual gate FETs (DGFETs). Furthermore, it is also shown that the proposed scheme is more efficient and works properly with the digital phase control method.

  • PDF

A New Control of Three-Phase PWM Rectifier with Single Current Sensor (단일 전류 센서를 사용한 3상 PWM 정류기의 새로운 제어)

  • Lee, U-Cheol;Hyeon, Dong-Seok;Lee, Taek-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.8
    • /
    • pp.440-447
    • /
    • 1999
  • This paper proposes a control method for three-phase PWM rectifier with only single current sensor in DC link side. A PWM modulation strategy for reconstructing three phase currents from the DC link current is given. The states of the retifier switch are modified so that all phase currents can be reconstructed in a switching period although one or two of active vectors is applied only for a short time. Therefore, a new current control using an adjustment scheme of the modulation signal for three-phase PWM rectifier will be discussed, and verified the experimental results.

  • PDF

Active front end inverter with quasi - resonance

  • Siebel H.;Pacas J. M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.146-150
    • /
    • 2001
  • A new three-phase soft-switching active front-end inverter is presented. The topology consists of a quasi-resonant PWM boost converter with an additional resonant branch, which provides low loss at high frequency operation. This leads to a high conversion efficiency and a remarkable reduction in the size of the input inductor. To synchronise the PWM pattern with the resonance cycle, a modified space vector modulation with asymmetrical PWM pattern is used. A high power factor can be achieved for both power flow directions. Due to a new control strategy the converter features a low content of harmonics in the line currents even for distorted line voltages.

  • PDF

Stability Analysis of the Magnetic Structures Producing an M6.5 Flare in active region 12371

  • Kang, Jihye;Inoue, Satoshi;Kusano, Kanya;Park, Sung-Hong;Moon, Yong-Jae
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.41.1-41.1
    • /
    • 2019
  • The stability analysis of coronal magnetic structures is important for studying the initiation of solar flares and eruptions. In order to understand the flare onset process, we first reconstructed the 3D coronal magnetic structures of active region 12371 with an M6.5 flare using a nonlinear force-free field (NLFFF) model based on vector magnetic fields. The NLFFFs successfully produce the observed sigmoidal structure which is composed of two branches of sheared arcade loops. The stability analysis were examined for three representative MHD instabilities: the kink, the torus, and the double arc instabilities. Our stability analysis shows that the two branches of sheared arcade loops are quite stable against the kink and torus instabilities, but unstable against the double arc instability before the flare occurrence. Finally, we discuss a probable onset process of the M6.5 flare.

  • PDF

Parameter Extraction of HEMT Small-Signal Equivalent Circuits Using Multi-Bias Extraction Technique (다중 바이어스 추출 기법을 이용한 HEMT 소신호 파라미터 추출)

  • 강보술;전만영;정윤하
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.353-356
    • /
    • 2000
  • Multi-bias parameter extraction technique for HEMT small signa] equivalent circuits is presented in this paper. The technique in this paper uses S-parameters measured at various bias points in the active region to construct one optimization problem, of which the vector of unknowns contains only a set of bias-independent elements. Tests are peformed on measured S-parameters of a pHEMT at 30 bias points. Results indicate that the calculated S-parameters is similar to the measured data.

  • PDF

Implementation of Grid Connection of DFIG for Wind Power Generation System

  • Abo-Khalil, Ahmed G.;Lee, Dong-Choon
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.143-145
    • /
    • 2006
  • This paper presents an overall control algorithm for a grid-connected wind-power generation system using a DFIG(doubly-fed induction generator) fed by back-to-back PWM converters. The control of DFIG is based on a stator-flux oriented vector control. The system enables not only fast and smooth synchronization but also high performance regulation of active and reactive power. Experimental results shows The feasibility of the control algorithm.

  • PDF

Voltage Source HVDC System Controller Design (전압형 HVDC 시스템 제어기설계)

  • 곽주식
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.645-650
    • /
    • 2000
  • this paper deals with HVDC Light(High Voltage Direct Current) system using space vector PWM(SVPWM) method. Because the system of this paper has d-q control scheme for HVDC Light system. HVDC Light system represented in this paper is capable of controlling active and reactive power independently. For this system. V-I curve and control methods are proposed. Also this paper describes the design of a digital system for applications in power converters such as those that would be used in the next generation of HVDC system. Finally HVDC system is implemented using DSP TMS320C31

  • PDF

UPFC Controller Design and Simulation Model (UPFC의 제어기 설계와 시뮬레이션 모델)

  • 한병문;박덕희;박지용
    • Proceedings of the KIPE Conference
    • /
    • 1998.11a
    • /
    • pp.49-54
    • /
    • 1998
  • This paper describes a simulation model to analyze the dynamic performance of Unified Power Flow Controller, which adjust flexibly the active and reactive power flow through the ac transmission line. The basic operation was analyzed in detail using equivalent circuits and the design of control system was developed using vector control method. A simulation model with EMTP code was conceived to evaluate the performance of the Unified power Flow Controller. The simulation results show that the developed simulation model is very effective to analyze the dynamic performance of the Unified Power Flow Controller.

  • PDF

Single Current Sensor Technique considering a Snubber Current and a Modified SVPWM Inverter for AC Motor Drives (스누버 전류를 고려한 개선된 SVPWM 인버터를 이용한 상전류센서없는 전동기 구동)

  • 주형길;신휘범;안희욱;윤명중
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.399-402
    • /
    • 1999
  • The single sensor technique reconstructing phase currents from the dc-link current without phase current sensors in proposed. When the duration of active vector is too short for the snubber current to reduce, the dc-link current including the snubber current gives large detection error. The solution is presented by analyzing the snubber current and modifying the switching sequences. This scheme is simple, requires only one sampling a period and has good results for detecting the phase currents.

  • PDF

Instantaneous Reactive Power Compensation Theory Increasing The Control Freedom One Degree Higher (제어 자유도를 한 차원 증가시킨 순시무효전력 보상이론)

  • Kim, Hyo-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2481-2483
    • /
    • 1999
  • This paper proposed the p-q-r coordinate system where the instantaneous active power p, and the two instantaneous reactive powers $q_{q}$, $q_{r}$ were defined. The three power components are linearly independent, so the compensation for the two instantaneous reactive powers leads to control the two components of the current space vector. With the theory, the neutral current of a three-phase four-wire system can be eliminated by only compensating the instantaneous reactive power using no energy storage element.

  • PDF