• Title/Summary/Keyword: Active pad

Search Result 51, Processing Time 0.027 seconds

Fabrication and Reliability Test of Device Embedded Flexible Module (디바이스 내장형 플렉시블 전자 모듈 제조 및 신뢰성 평가)

  • Kim, Dae Gon;Hong, Sung Taik;Kim, Deok Heung;Hong, Won Sik;Lee, Chang-Woo
    • Journal of Welding and Joining
    • /
    • v.31 no.3
    • /
    • pp.84-88
    • /
    • 2013
  • These days embedded technology may be the most significant development in the electronics industry. The study focused on the development of active device embedding using flexible printed circuit in view of process and materials. The authors fabricated 30um thickness Si chip without any crack, chipping defects with a dicing before grinding process. In order to embed chips into flexible PCB, the chip pads on a chip are connected to bonding pad on flexible PCB using an ACF film. After packaging, all sample were tested by the O/S test and carried out the reliability test. All samples passed environmental reliability test. In the future, this technology will be applied to the wearable electronics and flexible display in the variety of electronics product.

Leision Detection in Chest X-ray Images based on Coreset of Patch Feature (패치 특징 코어세트 기반의 흉부 X-Ray 영상에서의 병변 유무 감지)

  • Kim, Hyun-bin;Chun, Jun-Chul
    • Journal of Internet Computing and Services
    • /
    • v.23 no.3
    • /
    • pp.35-45
    • /
    • 2022
  • Even in recent years, treatment of first-aid patients is still often delayed due to a shortage of medical resources in marginalized areas. Research on automating the analysis of medical data to solve the problems of inaccessibility for medical services and shortage of medical personnel is ongoing. Computer vision-based medical inspection automation requires a lot of cost in data collection and labeling for training purposes. These problems stand out in the works of classifying lesion that are rare, or pathological features and pathogenesis that are difficult to clearly define visually. Anomaly detection is attracting as a method that can significantly reduce the cost of data collection by adopting an unsupervised learning strategy. In this paper, we propose methods for detecting abnormal images on chest X-RAY images as follows based on existing anomaly detection techniques. (1) Normalize the brightness range of medical images resampled as optimal resolution. (2) Some feature vectors with high representative power are selected in set of patch features extracted as intermediate-level from lesion-free images. (3) Measure the difference from the feature vectors of lesion-free data selected based on the nearest neighbor search algorithm. The proposed system can simultaneously perform anomaly classification and localization for each image. In this paper, the anomaly detection performance of the proposed system for chest X-RAY images of PA projection is measured and presented by detailed conditions. We demonstrate effect of anomaly detection for medical images by showing 0.705 classification AUROC for random subset extracted from the PadChest dataset. The proposed system can be usefully used to improve the clinical diagnosis workflow of medical institutions, and can effectively support early diagnosis in medically poor area.

The Effects of Corner Transistors in STI-isolated SOI MOSFETs

  • Cho, Seong-Jae;Kim, Tae-Hun;Park, Il-Han;Jeong, Yong-Sang;Lee, Jong-Duk;Shin, Hyung-Cheol;Park, Byung-Gook
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.615-618
    • /
    • 2005
  • In this work, the effects of corner transistors in SOI MOSFETs were investigated. We fabricated SOI MOSFETs with various widths and a fixed length and characterized them. The SOI thickness was $4000{\AA}$ and the buried oxide(BOX) thickness was $4000{\AA}$. The isolation of active region was simply done by silicon etching and TEOS sidewall formation. Several undesirable characteristics have been reported for LOCOS isolation in fabrication on SOI wafers so far. Although we used an STI-like process instead of LOCOS, there were still a couple of abnormal phenomena such as kinks and double humps in drain current. Above all, we investigated the location of the parasitic transistors and found that they were at the corners of the SOI in width direction by high-resolution SEM inspection. It turned out that their characteristics are strongly dependent on the channel width. We made a contact pad through which we can control the body potential and figured out the dependency of operation on the body potential. The double humps became more prominent as the body bias went more negative until the full depletion of the channel where the threshold voltage shift did not occur any more. Through these works, we could get insights on the process that can reduce the effects of corner transistors in SOI MOSFETs, and several possible solutions are suggested at the end.

  • PDF

Cobalt Oxide-Tin Oxide Composite: Polymer-Assisted Deposition and Gas Sensing Properties (PAD법으로 제작된 산화코발트-산화주석 복합체의 가스 감응 특성)

  • An, Sea-Yong;Li, Wei;Jang, Dong-Mi;Jung, Hyuck;Kim, Do-Jin
    • Korean Journal of Materials Research
    • /
    • v.20 no.11
    • /
    • pp.611-616
    • /
    • 2010
  • A cobalt oxide - tin oxide nanocomposite based gas sensor on an $SiO_2$ substrate was fabricated. Granular thin film of tin oxide was formed by a rheotaxial growth and thermal oxidation method using dc magnetron sputtering of Sn. Nano particles of cobalt oxide were spin-coated on the tin oxide. The cobalt oxide nanoparticles were synthesized by polymer-assisted deposition method, which is a simple cost-effective versatile synthesis method for various metal oxides. The thickness of the film can be controlled over a wide range of thicknesses. The composite structures thus formed were characterized in terms of morphology and gas sensing properties for reduction gas of $H_2$. The composites showed a highest response of 240% at $250^{\circ}C$ upon exposure to 4% $H_2$. This response is higher than those observed in pure $SnO_2$ (90%) and $Co_3O_4$ (70%) thin films. The improved response with the composite structure may be related to the additional formation of electrically active defects at the interfaces. The composite sensor shows a very fast response and good reproducibility.

Effects of corn gluten hydrolyzates, branched chain amino acids, and leucine on body weight reduction in obese rats induced by a high fat diet

  • Bong, Ha-Yoon;Kim, Ji-Yeon;Jeong, Hye-In;Moon, Min-Sun;Kim, Joo-Hee;Kwon, O-Ran
    • Nutrition Research and Practice
    • /
    • v.4 no.2
    • /
    • pp.106-113
    • /
    • 2010
  • In this study, we compared corn gluten hydrolyzates, BCAAs, and leucine for their effects on body weight reduction in high fat-induced obese rats in order to determine the major active components in the corn gluten hydrolyzates. After obesity was induced for 13 weeks with high fat diet, the overweight-induced SD rats (n = 64) were stratified according to body weight, randomly blocked into eight treatments, and raised for 8 weeks. Four groups were changed to a normal diet and the other groups remained on the high fat diet. Each of the groups within both diets was fed either casein, corn gluten hydrolyzates, leucine, or branched chain amino acids, respectively. Daily food intake, body weight gain, and food efficiency ratio were significantly lower in the corn gluten hydrolyzate groups compared to the other groups, regardless of the high fat diet or normal fat diet. The rats fed the corn gluten hydrolyzates diet had the lowest perirenal fat pad weights whereas muscle weight was significantly increased in the corn gluten hydrolyzates groups. Plasma triglyceride, hepatic total lipid, and total cholesterol contents were significantly reduced in the corn gluten hydrolyzates groups. Other lipid profile measurements were not significantly changed. Plasma triglyceride and hepatic total lipid were also significantly reduced in the BCAA and leucine groups. Leptin levels were significantly lower and adiponectin was significantly higher in the corn gluten hydrolyzates groups. Fasting blood glucose, insulin, C-peptide, and HOMA-IR levels were also significantly reduced in the corn gluten hydrozylates groups, regardless of fat level.

Effect of Oil Supply Direction on Power Loss and Bearing Temperature of Elliptical Bearing (오일공급 방향에 따른 타원형 베어링 손실 및 온도 특성)

  • Bang, Kyungbo;Choi, Yonghoon;Cho, Yongju
    • Tribology and Lubricants
    • /
    • v.34 no.4
    • /
    • pp.138-145
    • /
    • 2018
  • Elliptical bearings are widely used for large steam turbines owing to their excellent load carrying capacity and good dynamic stability. Power loss in bearings is an extremely important parameter, especially for high turbine capacities. Optimization of operation conditions and design variables such as bearing clearance and bearing length can reduce the power loss in elliptical bearings. Although changes in the oil supply method have served to increase the efficiency of the tilting pad journal bearing, it has not explicitly improved elliptical bearings. In this study, we verify the static characteristics of an elliptical bearing by changing the direction of oil supply. We evaluate the bearing power loss and bearing metal temperature, and compare the bearing performance and reliability in different test cases. The direction of oil supply is $90^{\circ}$ (9 o'clock) and $270^{\circ}$ (3 o'clock) when the rotor rotates in a counterclockwise direction. We use an elliptical bearing with an inner diameter and active length of 220.30 and 110.00 mm, respectively. Bearing power loss and bearing metal temperatures are measured and evaluated by rotor rotational speed, oil flow rate, and bearing load. The results reveal a 20 reduction in the power loss when the direction of oil supply is 90. Furthermore, the oil film on the upper part of the bearing has a high temperature when the direction of oil supply is $90^{\circ}$. In contrast, when the direction of oil supply is $270^{\circ}$, the oil film on the upper part of the bearing is relatively cold.

Anticachexic Effects of Kwibi-tang on Non-small Cell Lung Carcinoma, NCI-H520 Xenograft Mice (귀비탕(歸脾湯)이 비소세포 폐암세포(NCI-H520) 이식 마우스에서 악액질 억제에 미치는 영향)

  • Son, Ji-young;Kim, Kyung-soon;Choi, Hae-Yun;Kim, Jong-Dae
    • Journal of Korean Traditional Oncology
    • /
    • v.20 no.2
    • /
    • pp.23-36
    • /
    • 2015
  • Purpose : The object of this study was to observe anti-cachexic effects of Kwibi-tang extracts (KBTe) on non-small cell lung carcinoma (squamous epithelial carcinoma), NCI-H520, xenograft Balb/c nu-nu nude mice. Methods : Three different dosages of KBTe, 50, 100 and 200 mg/kg were orally administered once a day for 42 days from 11 days after tumor cell inoculation. Six groups, each of 8 mice per group were used in the present study. Changes on the body weight, the epididymal fat weight and serum IL-6 levels were detected with the thicknesses of deposited cervical brown adipose tissue and their mean diameters to monitor the tumor-related anticachexic effects. Results : Deceases on the body weight and gains were also demonstrated in tumor-bearing control with increases of serum IL-6 levels, decreases of epididymal fat pad weight, atrophic changes of cervical brown adipose tissues. These are means that tumor-related cachexia are induced by tumor cell inoculations in the present study. However, these tumor-related cachexia were markedly inhibited by all three different dosages of KBTe treatment as compared with tumor-bearing control. 5-FU showed somewhat deteriorated the tumor-related cachexia in the present study. Conclusion : The results obtained in this study suggest that over 50 mg/kg of KBTe showed favorable anticachexic effects on the NCI-H520 cell xenograft. However, detail mechanism studies should be conducted in future with the screening of the biological active compounds in this herb.

Effect of Pretreatment on Dyeability and Functionalities of Summer Rayon fabrics Finished by Gallnut Extract (전처리가 오배자 추출물에 의한 여름용 인견직물의 염색 및 기능성 향상에 미치는 영향)

  • Hwang, Hyun Ju;Hong, Kyung Hwa
    • Fashion & Textile Research Journal
    • /
    • v.18 no.2
    • /
    • pp.244-251
    • /
    • 2016
  • Viscose rayon filament fabrics have been called 'artificial silk' and beloved as summer clothing materials for a long time in Korea. This is because the viscose rayon filament fabrics reveals glossy surface and cool touch feeling compared to other conventional fabrics composed of staple fibers. Therefore, we tried to prepare the higher value added viscose rayon filament fabrics for summer textile products. In this study, we applied gallnut extract to the viscose rayon filament fabric to develop summer fabrics with natural color and multi-functions such as antibacterial and antioxidant properties. This process also pursue eco-friendly and multi-functional fabric finishing from the natural material "gallnut". In addition, various pre-treatment with cationizer, chitosan, or chito-oligomer was applied to the finishing process to improve the finishing efficacy and durability. Consequently, it was found that the active component of gallnut extract was successfully incorporated to the viscose rayon filament fabric through a pad-dry-cure process. And, the treated viscose rayon filament fabrics showed excellent antibacterial and antioxidant properties. Therefore, it was expected that the rayon filament fabrics treated by gallnut extract could be used as effective summer fabrics preventing the growth of bacteria and skin ageing as well as providing cool touch feeling. However, the pre-treatments were not that meaningful on the functionalities but effective on coloring.

Thermotherapy and Dynamic Warm-up on the Kinetic Parameters during Drop-landing (드롭랜딩 시 국소부위 온열처치와 동적 준비운동이 하지의 운동역학적 변인에 미치는 영향)

  • Kim, Sungmin;Song, Jooho;Han, Sanghyuk;Moon, Jeheon
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.4
    • /
    • pp.297-307
    • /
    • 2021
  • Objective: The aim of this study was to analyze kinetic variables between thermotherapy and dynamic warm-up during drop-landing. Method: Twenty male healthy subjects (Age: 21.85 ± 1.90 years, Height: 1.81 ± 0.06 cm, Weight: 68.5 ± 7.06 kg) underwent three treatments applied on the thermotherapy of femoral muscles and a dynamic warm-up. The thermotherapy was performed for 15 minutes while sitting in a chair using an electric heating pad equipped with a temperature control device. Dynamic warm-up performed 14 exercise, a non-treatment was sitting in a chair for 15 minutes. Core temperature measurements of all subjects were performed before landing at a height of 50 cm. During drop-landing, core temperature, joint angle, moment, work of the sagittal plane was collected and analyzed. All analyses were performed with SPSS 21.0 and for repeated measured ANOVA and Post-hoc was Bonferroni. Results: Results indicated that Thermotherapy was increased temperature than other treatments (p = .000). During drop-landing, hip joint of dynamic warm-up was slower for angular velocity (p < .005), and left ankle joint was fastest than other treatments (p = .004). Maximum joint moment of dynamic warm-up was smaller for three joints (hip extension: p = .000; knee flexion/extension: p = .001/.000; ankle plantarflexion: p = .000). Negative work of dynamic warm-up was smaller than other treatments (p = .000). Conclusion: In conclusion, the thermotherapy in the local area doesn't affect the eccentric contraction of the thigh. The dynamic warm-up treatment minimized the joint moment and negative work of the lower joint during an eccentric contraction, it was confirmed that more active movement was performed than other treatment methods.

The Study on the Embedded Active Device for Ka-Band using the Component Embedding Process (부품 내장 공정을 이용한 5G용 내장형 능동소자에 관한 연구)

  • Jung, Jae-Woong;Park, Se-Hoon;Ryu, Jong-In
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.3
    • /
    • pp.1-7
    • /
    • 2021
  • In this paper, by embedding a bare-die chip-type drive amplifier into the PCB composed of ABF and FR-4, it implements an embedded active device that can be applied in 28 GHz band modules. The ABF has a dielectric constant of 3.2 and a dielectric loss of 0.016. The FR-4 where the drive amplifier is embedded has a dielectric constant of 3.5 and a dielectric loss of 0.02. The proposed embedded module is processed into two structures, and S-parameter properties are confirmed with measurements. The two process structures are an embedding structure of face-up and an embedding structure of face-down. The fabricated module is measured on a designed test board using Taconic's TLY-5A(dielectric constant : 2.17, dielectric loss : 0.0002). The PCB which embedded into the face-down expected better gain performance due to shorter interconnection-line from the RF pad of the Bear-die chip to the pattern of formed layer. But it is verified that the ground at the bottom of the bear-die chip is grounded Through via, resulting in an oscillation. On the other hand, the face-up structure has a stable gain characteristic of more than 10 dB from 25 GHz to 30 GHz, with a gain of 12.32 dB at the center frequency of 28 GHz. The output characteristics of module embedded into the face-up structure are measured using signal generator and spectrum analyzer. When the input power (Pin) of the signal generator was applied from -10 dBm to 20 dBm, the gain compression point (P1dB) of the embedded module was 20.38 dB. Ultimately, the bare-die chip used in this paper was verified through measurement that the oscillation is improved according to the grounding methods when embedding in a PCB. Thus, the module embedded into the face-up structure will be able to be properly used for communication modules in millimeter wave bands.