• Title/Summary/Keyword: Active Protection

Search Result 597, Processing Time 0.028 seconds

Automatic Intrusion Response System based on a Self-Extension Monitoring (자기확장 모니터링 기반의 침입자동대응 시스템)

  • Jang, Hee-Jin;Kim, Sang-Wook
    • Journal of KIISE:Information Networking
    • /
    • v.28 no.4
    • /
    • pp.489-497
    • /
    • 2001
  • In the coming age of information warfare, information security patterns take on a more offensive than defensive stance. It is necessary to develop an active form of offensive approach to security protection in order to guard vital information infrastructures and thwart hackers. Information security products need to support an automatic response facility without human intervention in order to minimize damage to the attacked system and cope with the intrusion immediately. This paper presents an automatic intrusion response model which is developed on a Self-Extension Monitoring. It also proposes an ARTEMIS(Advanced Realtime Emergency Management and Intruder Identification System), which is designed and implemented based on the suggested model. The Self-Extension Monitoring using self-protection and replication minimizes spatial limitations on collection of monitoring information and intruder tracing. It enhances the accuracy of intrusion detection and tracing.

  • PDF

A Study on Islandig Characteristics using Phase Angle Adjustment of Distributed Generation (배전계통연계 분산전원의 위상변화에 따른 고립운전 파라미터 특성)

  • Bang, Ji-Yoon;Kim, Hak-Man;Lee, Bock-Ku;Sim, Jae-Sun;Shin, Myong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.525-526
    • /
    • 2006
  • Recently, much research has been done and many improvements have been developed for islanding protection of distributed generation(DG). Anti-islanding protection for DG must be act very quickly to prevent equipment damage at the time of disconnection and for the safety of maintenance and repair personnel. DG-based detection methods have included both passive and active types, and now research has shifted towards new anti-islanding detection methods that make up for the defects of the previous types. Because differences occur between the utility grid and the DG when connecting and disconnecting depending on the phase difference, voltage, current, relative capacity of electric power, and system operation characteristics, voltage phase angle is an important consideration. In this paper, we simulated islanded operation characteristics comparing phase difference of DG and the connected utility grid, and analyzed various parameters (real power, reactive power, RMS voltage, RMS current, power factor angle, and frequency) by varying the DG's voltage phase angle. Using this information, we propose a suitable DG voltage phase angle for enhanced passive islanding detection techniques.

  • PDF

Mothers′ Rearing Behavior and Peer Orientation of Early Adolescents (어머니의 양육행동과 초기청소년의 또래지향)

  • 신효식;이선정;박순화
    • Korean Journal of Human Ecology
    • /
    • v.4 no.1
    • /
    • pp.26-35
    • /
    • 2001
  • The Purpose of this study was to examine the difference among peer orientation according to socio-demographic variables and mothers' rearing behavior of early adolescents and to analyze the effect of these variables influencing peer orientation. The subjects were 399 students-sixth grade and second grade in middle school students, living in Gwangju. The major findings were as follows : 1. Peer orientation of early adolescents showed partial differences according to the socio-demographic variables and mothers' rearing behavior. Peer advice seeking showed significant difference according to child's grade, reasoning guidance, affection and active-education of mother. And extreme peer orientation was difference in the child's grade, sex. family type, reasoning guidance and over-protection of mother. 2. The order in the effective power of variables on peer orientation of early adolescents was as following. Peer advice seeking was influenced by the child's grade and affection that were explained about 21%. And extreme peer orientation was influenced by reasoning guidance. over-Protection. the child's sex, and family type that were explained about 17%. In conclusion, Mothers' rearing behavior was influenced on peer orientations. Above all children's peer orientations are need for the improvement mothers' behavior reasoning guidance. affection.

  • PDF

THE CLASSIFICATION SYSTEM OF RIVER HEALTH FOR THE ENVIRONMENTAL WATER QUALITY MANAGEMENT

  • Carolyn G. Palmer;Jang, Suk-Hwan
    • Water Engineering Research
    • /
    • v.3 no.4
    • /
    • pp.259-267
    • /
    • 2002
  • South Africa has developed a policy and law that calls and provides for the equitable and sustainable use of water resources. Sustainable resource use is dependent on effective resource protection. Rivers are the most important freshwater resources in the country, and there is a focus on developing and applying methods to quantify what rivers need in terms of flow and water quality. These quantified and descriptive objectives are then related to specified levels of ecological health in a classification system. This paper provides an overview of an integrated and systematic methodology, where, fer each river, and each river reach, the natural condition and the present ecological condition are described, and a level/class of ecosystem health is selected. The class will define long term management goals. This procedure requires each ecosystem component to be quantified, starting with the abiotic template. A modified flow regime is modelled for each ecosystem health class, and the resultant fluvial geomorphology and hydraulic habitats are described. Then the water chemistry is described, and the water quality changes that are likely to occur as a consequence of altered flows are predicted. Finally, the responses to the stress imposed on the biota (fish, invertebrates and vegetation) by modified flow and water quality are predicted. All of the predicted responses are translated into descriptive and/or quantitative management objectives. The paper concludes with the recognition of active method development, and the enormous challenge of applying the methods, implementing the law, and achieving river protection and sustainable resource-use.

  • PDF

Studies on the Physico-chemical Properties of Mixed Radioactive Waste Glass

  • Kim, C.W.;Choi, J.R.;Ji, P.K.;Park, J.K.;Shin, S.W.;Ha, J.H.;Song, M.J.;Hwang, T.W.;Park, S.J.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.1
    • /
    • pp.33-39
    • /
    • 2004
  • In order to vitrify the W1 waste (ion-exchange resin(IER), zeolite, and dry active waste(DAW)) generated from Korean Nuclear Power Plants, a glass formulation development based on waste compositions and production rates was performed. A aluminoborosilicate glass, AG8W1, was formulated to vitrify the W1 waste in an induction cold crucible melter(CCM). The processability, product performance, and economics of the candidate glass were calculated using a computer code and were measured experimentally in the laboratory and CCM. The glass viscosity and electrical conductivity as the process parameters were in the desired ranges. Start-up and maintaining glass melt of the candidate glass were favorable in the CCM. The product quality of the glass such as chemical durability, phase stability, etc. was satisfactory. The vitrification process using the candidate glass was also evaluated to be operated as economically as possible.

Protective effect of ginsenoside Rh3 against anticancer drug-induced apoptosis in LLC-PK1 kidney cells

  • Lee, Hye Lim;Kang, Ki Sung
    • Journal of Ginseng Research
    • /
    • v.41 no.2
    • /
    • pp.227-231
    • /
    • 2017
  • Background: Ginsenosides are active components of Panax ginseng that exert various health benefits including kidney protection effect. The medicinal activity of ginsenosides can be enhanced by modulating their stereospecificity by heat processing. Ginsenosides Rk2 and Rh3 represent positional isomers of the double bond at C-20(21) or C-20(22). Methods: The present study investigated the kidney-protective effects of ginsenosides Rk2 and Rh3 against cisplatin, a platinum based anticancer drug, induced apoptotic damage in renal proximal LLC-PK1 cells. Results: As a result, ginsenoside Rh3 shows a stronger protective effect than that shown by Rk2. Cisplatin-induced elevated protein levels of phosphorylated c-Jun N-terminal kinase (JNK), extracellular signal-regulated kinase (ERK), p38, and cleaved caspase-3 decreased after cotreatment with ginsenoside Rh3. The increase in the percentage of apoptotic LLC-PK1 cells induced by cisplatin treatment also significantly reduced after cotreatment with ginsenoside Rh3. Conclusion: These results demonstrate that inhibition of the JNK and ERK mitogen-activated protein kinase signaling cascade plays a critical role in mediating the renoprotective effect of ginsenoside Rh3.

Study of the Effect of (U0.8Pu0.2)O2 Uranium-Plutonium Mixed Fuel Fission Products on a Living Organism

  • Baimukhanova, Ayagoz;Kim, Dmitriy;Zhumagulova, Roza;Tazhigulova, Bibinur;Zharaspayeva, Gulzhanar;Azhiyeva, Galiya
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.965-974
    • /
    • 2016
  • The article describes the results of experiments conducted on pigs to determine the effect of plutonium, which is the most radiotoxic and highly active element in the range of mixed fuel $(U_{0.8}Pu_{0.2})O_2$ fission products, on living organisms. The results will allow empirical prediction of the emergency plutonium radiation dose for various organs and tissues of humans in case of an accident in a reactor running on mixed fuel $(U_{0.8}Pu_{0.2})O_2$.

A Phenomenological Review on the Decision on the Cause of Ignition of Electric Iron (전기다리미의 발화원인 판정에 관한 현상학적 고찰)

  • Mun, Yong-Soo;Kong, Ha-Sung;Lee, Jong-Hwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.1
    • /
    • pp.43-49
    • /
    • 2009
  • This study set three kinds of situation and observed the various states such as carbonization by experimenting damages by fire of electric iron. The results of this study are as follows: The fire did not occurred when the unpowered iron over mattress and cotton shirts was com busted completely by external flame because the temperature of surface of soleplate and mattress did not reach the minimum ignition energy and when the powered electric iron over mattress and cotton shirts was left for an hour with its temperature dial set to high because the temperature of combustibles did not reach the minimum ignition energy. The fire occurred when the electric iron in which the outer box, bi-metal switch, and temperature fuse were removed over mattress and cotton shirts was powered by through heater terminal, and then the electric iron, mattress, and cotton shirts were combusted by the fallen combustibles because the temperature of combustibles reached to the minimum ignition energy with the help of active transfer of heat.

A LONG-TERM FIELD TEST OF A LARGE VOLUME IONIZATION CHAMBER BASED AREA RADIATION MONITORING SYSTEM DEVELOPED AT KAERI

  • Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Kim, Jung-Bok;Kim, Young-Kyun;Jin, Hyung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.2
    • /
    • pp.77-81
    • /
    • 2009
  • An Area Radiation Monitoring System (ARMS) ionization chamber, which had an 11.8 L active volume, was fabricated and performance-tested at KAERI. Low leakage currents, linearities at low and high dose rates were achieved from performance tests. The correlation coefficients between the ionization currents and the dose rates are 1 at high dose rate and 0.99 at low dose rate. In this study, an integration-type ARMS ionization chamber was tested over a year for an evaluation of its long-term stability at a radioisotope (RI) repository of the Young-gwang nuclear power plant. The standard deviation of dose rate of 1 day data and over a 100-days mean value were 6.2 $\mu$R/h and 2.9 $\mu$R/h, respectively. The fabricated ARMS ionization chamber showed stable performance from the results of the long-term tests. Design and performance characteristics of the fabricated ionization chamber for the ARMS from performance-tests are also addressed.

An ionization Chamber for a Steel Sheet Thickness Measurement

  • Kim, Han-Soo;Park, Se-Hwa;Kim, Yong-Kyun;Ha, Jang-Ho;Cho, Seung-Yeon
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.3
    • /
    • pp.149-153
    • /
    • 2006
  • An ionization chamber is still widely used in many fields by virtue of its' simple operational characteristics and the possibility of its' various shapes. A parallel type of an ionization chamber for a steel sheet thickness measurement was designed and fabricated. High pure xenon gas, which was pressurized up to 6 atm, was chosen as a filling gas to increase the current response and sensitivity for a radiation. A high pressure gas system was also constructed. The active volume and the incident window size of the fabricated ionization chamber were $30\;cm^3\;and\;12\;cm^2$, respectively. Preliminary tests with a 25 mCi $^{241}Am$ gamma-ray source and evaluation tests in a standard X-ray field were performed. The optimal operation voltage was set from the results of the collection efficiency calculation by using an experimental two-voltage method. Linearity for a variation of the steel sheet thickness, which is the most important factor for an application during a steel sheet thickness measurement, was 0.989 in this study.