• 제목/요약/키워드: Active Isolation System

검색결과 165건 처리시간 0.021초

전자석 액츄에이터에 의한 수동방진 테이블의 제어 (Vibration control of the vibration isolation system using the electromagnetic actuator)

  • 최현;이정윤
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.227-232
    • /
    • 2003
  • As the most precision equipment requiring very strict vibration environment are vulnerable to the surrounding vibration condition, they adapt the passive or active vibration isolation system. When it comes to the passive isolation system, the resonance of the isolation system causes excessive resonance response, and finally results in the degrade the equipment performance. This paper deals with the active control method to control this resonance induced response, and includes the experiment on the active control for controlling the resonance response on the table against the excitation of the same frequency with the natural frequency of the isolation system. The electromagnetic actuator was designed and the control effect was verified by the experiment. The experiment showed that the electromagnetic actuator is effective for controlling the low frequency isolation resonance response of the precision equipment.

  • PDF

공기스프링을 이용한 방진테이블의 능동 제어 (Active Control of Vibration Isolation Table Using Air-spring)

  • 안채헌;임광혁;진경복;임경화
    • 한국소음진동공학회논문집
    • /
    • 제17권7호
    • /
    • pp.565-571
    • /
    • 2007
  • In the process of accurate manufacture and measurement, it is necessarily required to isolate external or internal vibration due to external disturbance and internal actuators. The higher vibration isolation system gets damping around resonance, the better it is generally. This paper analyzes the performance of an existing passive air-spring for vibration isolation table by using experiment and simulation. Optimal design for a passive air spring can be obtained by tuning the size of the orifice. Also design for an active isolation system is carried out by applying PID controller and considering non-linearity of pneumatic characteristics with help of look-up table. We have developed the active vibration isolation table with the better isolation performance.

공기스프링을 이용한 방진 테이블의 능동 제어 (Active Control of Vibration Isolation Table Using Air-spring)

  • 안채헌;임광혁;권혁진;정진훈;배윤화;진경복;임경화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.831-836
    • /
    • 2006
  • In the process of accurate manufacture and measurement, it is necessarily required to isolate external or internal vibration due to external disturbance and internal actuators. The higher vibration isolation system gets damping around resonance, the better it is generally. This paper analyzes the performance of an existing passive air-spring for vibration isolation table by using experiment and simulation. Optimal design for a passive air spring can be obtained by tuning the size of the orifice. Also design for an active isolation system is carried out by applying PID controller and considering non-linearity of pneumatic characteristics with help of look-up table. We have developed the active vibration isolation table with the better isolation performance.

  • PDF

압전세라믹 감지기와 작동기를 이용한 방진 시스템 개발 (Development of the Vibration Isolation System using Piezoceramic Sensors and Actuators)

  • Seok Heo;Moon K. Kwak
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.309.2-309
    • /
    • 2002
  • This paper is concerned with the development of the vibration isolation system using piezoelectric actuators and sensors. The active vibration absorber system consists of 4 pairs of PZT actuators bonded on aluminum plates making s- shaped device. Hence, the active system is directly connected to the passive system. The rubber attached to the end of the beam is connected to the upper base as a structural member. It allows bending thus maximizing the vertical movement generated by the piezoceramic actuators. (omitted)

  • PDF

Lyapunov-based Semi-active Control of Adaptive Base Isolation System employing Magnetorheological Elastomer base isolators

  • Chen, Xi;Li, Jianchun;Li, Yancheng;Gu, Xiaoyu
    • Earthquakes and Structures
    • /
    • 제11권6호
    • /
    • pp.1077-1099
    • /
    • 2016
  • One of the main shortcomings in the current passive base isolation system is lack of adaptability. The recent research and development of a novel adaptive seismic isolator based on magnetorheological elastomer (MRE) material has created an opportunity to add adaptability to base isolation systems for civil structures. The new MRE based base isolator is able to significantly alter its shear modulus or lateral stiffness with the applied magnetic field or electric current, which makes it a competitive candidate to develop an adaptive base isolation system. This paper aims at exploring suitable control algorithms for such adaptive base isolation system by developing a close-loop semi-active control system for a building structure equipped with MRE base isolators. The MRE base isolator is simulated by a numerical model derived from experimental characterization based on the Bouc-Wen Model, which is able to describe the force-displacement response of the device accurately. The parameters of Bouc-Wen Model such as the stiffness and the damping coefficients are described as functions of the applied current. The state-space model is built by analyzing the dynamic property of the structure embedded with MRE base isolators. A Lyapunov-based controller is designed to adaptively vary the current applied to MRE base isolator to suppress the quake-induced vibrations. The proposed control method is applied to a widely used benchmark base-isolated structure by numerical simulation. The performance of the adaptive base isolation system was evaluated through comparison with optimal passive base isolation system and a passive base isolation system with optimized base shear. It is concluded that the adaptive base isolation system with proposed Lyapunov-based semi-active control surpasses the performance of other two passive systems in protecting the civil structures under seismic events.

압전세라믹을 이용한 능동진동제어장치의 개발 (Development of the Active Vibration Absorber Using Piezoelectric Actuators)

  • 곽명훈;허석;곽문규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.476-481
    • /
    • 2001
  • This research is concerned with development of the active vibration absorber using piezoelectric actuators. This active isolation system consists of a-pairs of PZT actuators bonded on a S-shaped aluminum plate and the passive damping material. The active system is connected to the passive system in series. In this paper, one of the popular control techniques which have been successfully applied to the smart structure is the Positive Position Feedback(PPF) control. The digital PPF control lows downloaded to the DSP chip and a main program, which runs SISO PPF algorithm. The structure and dynamic characteristics of the proposed active vibration isolation system and described in detail. To demonstate the effectiveness of the active vibration control, the PPF controller is first employed. Experimental results show that the active vibration isolation is possible by means of the proposed system.

  • PDF

이동 질량을 포함하는 능동형 공압제진대에 대한 시간지연제어기법의 적용 검토 (Examination on Active Pneumatic Vibration Isolation Table with Moving Masses on It by Time Delay Control)

  • 신윤호;문석준;정정훈;김병현
    • 한국소음진동공학회논문집
    • /
    • 제21권9호
    • /
    • pp.858-867
    • /
    • 2011
  • As applying an active control technique to a pneumatic vibration isolation system, the settling time for the payload excitation could be remarkably reduced as well as the improvement of isolation performance for the ground vibration. Some previous researches were dealt with the settling time through the simulation or experiment but, the discussion on the simulation or experimental results including moving parts, such as a XY-stage, on the isolation table rarely exists. As considering the moving part, the dynamic model could be time varying system and in such a case the force imposed on pneumatic vibration isolation table could be described by inertial forces of moving parts according to Newton's 3rd law, the action and reaction law. In this paper, the simulation procedure of the 3-DOF active pneumatic vibration isolation system including moving parts by TDC(time delay control) technique is proposed and the effectiveness through simulation results are also shown.

직렬형 능-수동 제진 방법을 이용한 1축 제진 시스템 (Single Axis Vibration Isolation System Using Series Active-passive Approach)

  • ;이동연;권대갑
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.176-179
    • /
    • 2005
  • To control the vibration transmitted to the precision instruments from ground has always been of great interest among the researchers. This paper proposes a single axis vibration isolation system which can be used as a module far a table top six axis isolator for highly precise measurement and actuation system. The combined active-passive isolation principle is used for vertical vibration isolation by mounting the instrument on a passively damped isolation system made of Elastomer along with the active stage in series which consists of very stiff piezo actuator. The active stage works in combination with the passive stage for working as a very low frequency vibration attenuator. The active stage is isolated from the payload disturbance through the Passive stage and thus modularity in control is achieved. This made the control algorithm much easier as it does not need to be tuned to specific payload.

  • PDF

Development of Active Vibration Isolation Equipments Using Fuzzy Method

  • Rim, Kyung-Hwa;Yang, Xun;An, Chae-Hun;Jin, Kyoung-Bog
    • 반도체디스플레이기술학회지
    • /
    • 제6권4호
    • /
    • pp.17-22
    • /
    • 2007
  • Vibration isolation equipments are mostly required in precise measurement and manufacturing system. Among all the vibration isolation equipments, air-spring is the most widely used equipment because of low resonant frequency and high damping ratio. In this study, we used Takagi-Sugeno fuzzy method to design an active vibration isolation system using air-spring, and compared the fuzzy method with passive control method and PID control method. Due to the non-linearity characteristics of air-spring, fuzzy controller was verified to be the most effective both in simulation and experiment.

  • PDF

지진하중을 받는 사장교를 위한 LRB-기반 복합 기초격리 시스템 (LRB-based Hybrid Base Isolation Systems for Seismically Excited Cable-Stayed Bridges)

  • 정형조;박규식;이헌재;이인원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.527-534
    • /
    • 2003
  • This paper presents the LRB-based hybrid base isolation systems employing additional active/semiactive control devices for seismic protection of cable-stayed bridges by examining the ASCE first generation benchmark problem for a cable-stayed bridge. In this study, ideal hydraulic actuators (HAs) and ideal magnetorheological dampers (MRDs) are considered as additional active and semiactive control devices, respectively. Numerical simulation results show that all the hybrid base isolation systems are effective in reducing the structural responses of the benchmark cable-stayed bridge under the historical earthquakes considered. The simulation results also demonstrate that the hybrid base isolation system employing semiactive MRBs is robust to the stiffness uncertainty of the structure, while the hybrid system with active HAs is not. Therefore, the LRB-based hybrid base isolation system employing MRDs could be more appropriate in real applications for full-scale civil infrastructures.

  • PDF